No video

Supercharge Your AHU Troubleshooting Skills with This Exercise

  Рет қаралды 4,577

HVACTIME

HVACTIME

Күн бұрын

In this livestream, I will walk you through troubleshooting an chilled water AHU service call. The customer complaint was for a symptom of the actual problem, so I will show you how to take the needed readings to get the right solution.
You'll learn how to:
Identify the customer's complaint and assess the situation
Perform the necessary tests and measurements
Diagnose the problem and determine the best course of action
Make the necessary repairs or adjustments
This livestream is perfect for HVAC technicians of all levels of experience. Whether you're new to the trade or you're looking for a refresher, you'll learn valuable troubleshooting skills that you can use in your everyday work.
Get 8% off at TruTech Tools with promo HVACTIME
www.trutechtoo...
Get tech support, training, and the Tech Blog at hvactimetx.com
techsupport@hvactimetx.com
hvactime@hvactimetx.com
Support my COFFEE problem through,
venmo.com/code...

Пікірлер: 30
@HelixtheCAT01
@HelixtheCAT01 3 ай бұрын
Like how you go from the basics of "common AC". This uses a different medium
@cristianjavier1485
@cristianjavier1485 11 ай бұрын
Hello. Thanks for taking the time to talk about it. I hope I run into same scenario sooner. Have a god lunch.
@eimantaslapienis4662
@eimantaslapienis4662 11 ай бұрын
Great exercise! Thank you. Hopefully you can make more like this.
@isaacsanchez3966
@isaacsanchez3966 11 ай бұрын
Keep doing what your doing these videos are educational
@GalacticAdventures69
@GalacticAdventures69 11 ай бұрын
These are fun honestly
@carllungwitz5171
@carllungwitz5171 8 ай бұрын
Air bound coil
@bureaucratbayonet
@bureaucratbayonet 10 ай бұрын
Pausing at about half way to say great video thanks so much. As soon as entering and leav8ng water revealed im thinking we wanna see a 10 degree split not 20. Been thinking refrigerant issues this whole time but its a little hard to picture what having a too high or too low superheat/ subcooling's effect would be on delta t. Other than that possible water flow issue is the only other thing i can think of after having come this far and eliminated other possibilities
@bureaucratbayonet
@bureaucratbayonet 10 ай бұрын
After finishing this...what a great learning opportunity! I was also thinking restriction after the coil but have not had enough experience to run into a situation of insufficient make up water. Thanks again!
@anom2789
@anom2789 9 ай бұрын
thank you!
@strutt01
@strutt01 11 ай бұрын
BA dude. Thanks for your work.
@bryangillis2515
@bryangillis2515 11 ай бұрын
Keep up the content like this
@rthompson968
@rthompson968 11 ай бұрын
Another good one 👍
@joeycrack4294
@joeycrack4294 11 ай бұрын
As far as the low static pressure,. I would check the office area for doors and windows open.
@colejc
@colejc 11 ай бұрын
thanks brotha appreciate the video
@dennisbarkley1551
@dennisbarkley1551 11 ай бұрын
Thanks😊
@MarcDiMillo
@MarcDiMillo 11 ай бұрын
Am I missing something? Why is vertical water column relevant in a closed loop system? Is the pump not a recirculating pump? Also, with the inlet gauge reading 1psi I would be weary of the reading unless it’s a compound gauge. The gauge might read 0 but the suction is in a vacuum.
@HVACTIME
@HVACTIME 11 ай бұрын
It is a recirculating pump but the column is still relevant whether its a closed loop or not. There has to be enough water volume to properly function.
@HEFTYLEFTY303
@HEFTYLEFTY303 11 ай бұрын
If your not getting adequate cooling to the space the vavs will end up driving wide open causing the low static problem
@joeycrack4294
@joeycrack4294 11 ай бұрын
Shouldn't the inlet to the chill water coil be on the bottom of the coil in order to keep the coil flooded, which will help to give you a lower or proper outlet temp,
@HVACTIME
@HVACTIME 11 ай бұрын
Ya i caught that after I started the training. I make mention of it through the class.
@Swiminfool139
@Swiminfool139 11 ай бұрын
Amps on the motor fla / rla?
@jameshendry9906
@jameshendry9906 11 ай бұрын
All the VAV ARE OPEN CAUSING LOW STATIC
@SOSguap
@SOSguap 11 ай бұрын
Fan spinning wrong way
@Swiminfool139
@Swiminfool139 11 ай бұрын
Not enough gpm
@Swiminfool139
@Swiminfool139 11 ай бұрын
Ductwork oversized
@Swiminfool139
@Swiminfool139 11 ай бұрын
Lined duct insulation fell off, blocking duct before sensor
@SOSguap
@SOSguap 11 ай бұрын
Dirty blower section
@jameshendry9906
@jameshendry9906 11 ай бұрын
Bcy
@Attest411
@Attest411 11 ай бұрын
This is great ✊🏻✊🏻… building stuff like this is at a premium…
@Swiminfool139
@Swiminfool139 11 ай бұрын
Fans going wrong direction
HVAC Tech Troubleshooting
52:38
HVACTIME
Рет қаралды 3,4 М.
DX vs Flooded: Chiller Evaporator Types
10:12
HVACTIME
Рет қаралды 1,6 М.
CHOCKY MILK.. 🤣 #shorts
00:20
Savage Vlogs
Рет қаралды 29 МЛН
Magic trick 🪄😁
00:13
Andrey Grechka
Рет қаралды 43 МЛН
SCHOOLBOY. Последняя часть🤓
00:15
⚡️КАН АНДРЕЙ⚡️
Рет қаралды 13 МЛН
Little brothers couldn't stay calm when they noticed a bin lorry #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 18 МЛН
AHU Supply Air Temperature and Pressure Resets
16:13
Slipstream
Рет қаралды 9 М.
Recovery for Water Cooled Chiller
11:58
HVACTIME
Рет қаралды 1,8 М.
TRANE RTAC Chiller compressor oil filter replacement
3:02
HVAC Tips&Tricks
Рет қаралды 9 М.
What is Surge in Centrifugal Compressor
9:43
HVACTIME
Рет қаралды 2,1 М.
Troubleshooting a chiller issue today
20:39
Curious HVAC Guy
Рет қаралды 23 М.
What is VGD in Centrifugal Compressor
8:58
HVACTIME
Рет қаралды 1,6 М.
Dental Lab Chilled Water AHU Not Cooling
11:47
Subcool HVAC
Рет қаралды 3,4 М.
Munters Dehumidifier working Principle
4:12
Md.Nihad Sikder
Рет қаралды 10 М.
Economizer Troubleshooting
8:53
David Harty
Рет қаралды 57 М.
Symptoms of Low Evaporator Airflow
12:59
HVAC School
Рет қаралды 50 М.
CHOCKY MILK.. 🤣 #shorts
00:20
Savage Vlogs
Рет қаралды 29 МЛН