It was very helpful as a starter in this field. VERY HELPFUL. thank you. I will watch and understand all the videos. BIG THANK YOU
@Systemcontroltech6 жыл бұрын
+Tony Alapatt thanks for watching
@emmyweed58272 жыл бұрын
Love the video It was really useful because I am now just starting off on the control side thank you
@Systemcontroltech2 жыл бұрын
Thanks for watching
@Brian-lt8ic6 жыл бұрын
Your videos are great. Thanks for posting and keep it up! That actually cleared up a few questions I had. Very appreciated
@Systemcontroltech6 жыл бұрын
Thanks for watching
@gvoudzon8320 Жыл бұрын
How do you get to work with Johnson Controls FEC controllers? In my neck of the woods in Cleveland, only Johnson Controls employees from the local Johnson Controls office get to work with them. I get to work with the PCG and PCX controllers, which look just like the FEC controllers.
@Systemcontroltech Жыл бұрын
We buy them directly from our local branch.
@billyreece49526 жыл бұрын
Very Helpful, much appreciated
@Systemcontroltech6 жыл бұрын
+Billy Reece thanks for watching and please subscribe for more
@pavelgroshev53267 жыл бұрын
I have been searching for various videos that can help me figure out how to work with CCT. Right now I'm stuck on an issue where I need to change AHU multi-zone physical zone temperature inputs(ZN-T) to network temperature inputs. How would I go about doing this? Appreciate the help!
@Systemcontroltech7 жыл бұрын
+Pavel Groshev what you want to do is first make a list of the connections where the current zone temp is used. You will then have to create a new network input by right clicking on the network portion of the input side. Once you create it, you'll have to reconnect it to the previous logic blocks. I have a couple videos on cct that will help. Check out my channel for more information.
@jodycompton45773 жыл бұрын
How can I get this software your using, or any software that can bring in points Thanks again Jody
@Systemcontroltech3 жыл бұрын
Contact jci
@sharanjohn43157 жыл бұрын
Hi , I'm using PCT 10.2 version to create a Program for the AHU operated with VFD . I have loaded the same Program into the controller , during the commissioning mode , I right clicked command on the SF-C ( supply fan command ) to ON and VFD signal (SF-O ) to 100 % . The AHU started to operate in full speed . As its started I received the SF-S (Supply Fan status ) ON . once I received the fan Status , I demanded the Zone Setpoint ZN-SP , But cooling valve doesnot actuate . What could be the reason.. In simulation mode , it works and I tried to show the involvement and found ZN-SP and ZN-T are linked with CLG-O Please help thank you
@Systemcontroltech7 жыл бұрын
+Sharan John view the logic when you are commissioned in and see if it has switched to control. It may be t-control or something similar. If it hasn't, look to see what switches the mode of the logic blocks. I have a few other videos on cct that may help.
@rollingbigpower6.737 жыл бұрын
I'am having trouble downloading a file. I keep getting failed operation , in the failed status it says application failed additional info device state startup in progress. I've powered controller on and off multiple times. Any suggestions? I'm using pct version 10.2
@Systemcontroltech7 жыл бұрын
+Spyder-Man 79 I had the very same thing happen to me the other day. It was a bad fec and there wasn't anything I could do. I was plugged directly into the controller but couldn't get it to work.
@shivarajprasad84627 жыл бұрын
I m using 2.2 version .how to open in working control to CCT
@pavelgroshev53266 жыл бұрын
I have been searching for various videos that help me a lot. I am wondering if it possible to upgrade NAE 5.2 firmware version to 8.1 firmware version and how would I go about doing this? Appreciate the help!
@Systemcontroltech6 жыл бұрын
+Pavel Groshev depending on the NAE, don't do it. 8.1 has a serious issue with the nae55. If it is a smaller nae you can upgrade it from sct. That's a new thing with the newer version. Just do a code download from sct
@pavelgroshev53266 жыл бұрын
We have couple upgraded NAE55, they seems to be working fine and I need to upgrade few more because of we need to add wireless trunk. I was tolled we need to use NAE update tool. Do you have any idea how to do it?
@Systemcontroltech6 жыл бұрын
+Pavel Groshev some of the tools are restricted by jci. That's one tool I haven't been able to get my hands on. You don't need that tool to add a wireless trunk. You will add the coordinator like any other device and all your wireless devices go to the coordinator.
@alialavi72426 жыл бұрын
Can you make a video on how to setup BBMD for third party devices
@Systemcontroltech2 жыл бұрын
Maybe
@GtrMan8635 жыл бұрын
Do you have a gas meter pulse monitoring program video ?
@Systemcontroltech5 жыл бұрын
Ive got a video showing how to add a meter which is basically the same thing. A pulse count regardless of the source is the same. You just need to know the multiplier