Are those angle fittings on the recovery machine supposed to swivel?
@bkluntz Жыл бұрын
Do I open the low and high side on my gauges?
@wmgmusicgroup Жыл бұрын
Yes
@nizarokab-p8v6 күн бұрын
@@wmgmusicgroupstart with the liquid for 4-6 minute then open the vapor. Turning the indoor fan ON will also speed up the recovery
@shieldcracker6 ай бұрын
Why the need to invert the cylinder?
@boywhohadatiger6 ай бұрын
Forces liquid refrigerant through the suction tube which is wider and will allow the liquid to mix in with liquid better and keep your tank cooler and speed up recovery. This is the way I perform mine and I rarely have to use ice too keep my tank cool
@chrishewlet54716 ай бұрын
Did you not watch the video?
@shieldcracker5 ай бұрын
@@chrishewlet5471I evidently did otherwise I couldn't be asking the question. Read my comment again and tell me where in the video is the answer to my queation.
@outlawgonzalez64715 ай бұрын
@@shieldcracker 1:49
@shieldcracker5 ай бұрын
@@outlawgonzalez6471 Why the need to invert the cylinder you can accomplish the same with the cylinder upright