Tesla Powerwall 3 with 8.5kW solar panels

  Рет қаралды 18,481

SolarEngineering

SolarEngineering

Күн бұрын

Installing 21 solar panel on comp shingles roof. With Tesla Powerwall 3.
8.5kW DC + 11.5kW AC output with 13.5kWh of capacity.
#teslapowerwall #teslaenergy

Пікірлер: 46
@carlosschmidt6035
@carlosschmidt6035 3 ай бұрын
Look awesome and clean installation. Good job !!
@Scherich
@Scherich 6 күн бұрын
Clean job. I know the dolly is expensive, but man does it help. I have no problems mounting Powerwall by myself now. Hopefully you get one someday.
@SolarEngineering
@SolarEngineering 3 күн бұрын
thanks! I just got dolly, was waiting 2 month for it.
@rchezuir3780
@rchezuir3780 17 күн бұрын
You do a clean job brother . Have learned a few tricks from you the conduit spacer is awaome
@ciaotesla
@ciaotesla 3 ай бұрын
nice work!
@Electronzap
@Electronzap 3 ай бұрын
Nice project.
@TeslaElonSpaceXFan
@TeslaElonSpaceXFan 3 ай бұрын
Tesla Energy 😍😍
@anispinner
@anispinner 3 ай бұрын
Real magician :)
@tvguide4khv
@tvguide4khv 3 ай бұрын
Child used at work ) Good accent)) Indicates your origin, but obviously not so readable -- but it is always worth watching more old movies like Gone with the Wind )
@tvguide4khv
@tvguide4khv 3 ай бұрын
Perhaps some mesh is best used as a perimeter cover? PV cooling is a must + bird nesting protection.
@SolarEngineering
@SolarEngineering 3 ай бұрын
usually not installed in our area
@EVMANVSGAS
@EVMANVSGAS 2 ай бұрын
I am installing the universal wall connector in hopes of getting a cybertruck to run my house on. Do i need to run a communication wire to the universal wall connector for power share to work? I do not see where the com wire would connect in the universal wall connector but another video I watched the guy said they ran a com wire so it's confusing. Thanks, love your install videos.
@pederb82
@pederb82 3 ай бұрын
Curious - have you ever had any issue with cable insulation melting when you paint conduit pipe black on an roof like that? I would imagine they will get quite warm. Clean install as always, good job! :D
@SolarEngineering
@SolarEngineering 3 ай бұрын
oh man, not yet 🤞 thanks!
@pederb82
@pederb82 3 ай бұрын
@@SolarEngineering the cables are usually rated for quite high temps. But I’m just thinking. Black metal is auch to touch. But not sure what the surface temp get to there.
@tvguide4khv
@tvguide4khv 3 ай бұрын
@@SolarEngineering Throw paint only from street view side. May be not black but grayish as shingles.
@rchezuir3780
@rchezuir3780 17 күн бұрын
I was curious , what kind of wire are you running for the emergency stop button ?
@SolarEngineering
@SolarEngineering 16 күн бұрын
18/2 Unshielded VNTC Tray Cable
@rchezuir3780
@rchezuir3780 16 күн бұрын
@@SolarEngineeringRoger brother , I am in the states it was saying to use the power wall 3 communication cable
@AutoTuned
@AutoTuned 3 ай бұрын
How much would you charge to install 20 400w panels with enphase system?
@SolarEngineering
@SolarEngineering 3 ай бұрын
Location/roof type/height of the building/batteries?
@AutoTuned
@AutoTuned 3 ай бұрын
@@SolarEngineering Southern California, two story, flat tile roof and no batteries. I think it is about 30 ft from the ground. Also, I’ll supply all the materials.
@ibrownbear6531
@ibrownbear6531 3 ай бұрын
🎉🎉🎉🎉🎉
@chevaliercognac8757
@chevaliercognac8757 3 ай бұрын
Хорошее видео, спасибо за информацию. Скажите пожалуйста сколько стоит такая установка? Это вы в Америке? Я в Англии.
@SolarEngineering
@SolarEngineering 3 ай бұрын
да, в Калифорнии.Здесь дорогой labor, такая установка стоит тридцать тысяч +. В конце года владельцу с налогов вернется 30%.
@d.pollard5962
@d.pollard5962 3 ай бұрын
Did you do this in one day, how long did it take?
@SolarEngineering
@SolarEngineering 3 ай бұрын
oh no, I have a roof helper only. All electrical doing myself, It took me 2.5 days.
@jimmybrad156
@jimmybrad156 Ай бұрын
What does the spray paint do?
@SolarEngineering
@SolarEngineering Ай бұрын
just visual aesthetics
@andrewyang1446
@andrewyang1446 2 ай бұрын
Are the panels in series or parallel? Or both?
@SolarEngineering
@SolarEngineering 2 ай бұрын
2 strings: 12 and 9 panels in series
@theotherfaceof
@theotherfaceof 22 күн бұрын
you can use wood and a cheap car jack
@SolarEngineering
@SolarEngineering 22 күн бұрын
thanks
@BTx789
@BTx789 2 ай бұрын
inverter kwh?
@SolarEngineering
@SolarEngineering 2 ай бұрын
11.5kW / 13.5kWh
@BTx789
@BTx789 2 ай бұрын
@@SolarEngineering why did you install a big inverter? why not use an inverter with the same kwh as the panels or a smaller inverter?
@SolarEngineering
@SolarEngineering 2 ай бұрын
@@BTx789 Tesla Powerwall 3 has fixed power/capacity, you cannot buy a lower wattage inverter, it's built in.
@pmbpmb5416
@pmbpmb5416 3 ай бұрын
So annoying still can’t buy the powerwall 3 in UK
@SolarEngineering
@SolarEngineering 3 ай бұрын
I was lucky to get this one. Waiting for a month for another project.
@unclegeorge7845
@unclegeorge7845 3 ай бұрын
6 gauge wire is not big enough for 60 amp breaker. Out of code!
@SolarEngineering
@SolarEngineering 3 ай бұрын
wrong
@unclegeorge7845
@unclegeorge7845 3 ай бұрын
@@SolarEngineering A 6 AWG copper wire typically has an ampacity of 55-65 amps. However, the wire's ampacity may be reduced if the cable is bundled with other cables or is placed in high ambient temperatures. According to the National Electrical Code (NEC), a 50 amp circuit breaker should use 6 American Wire Gauge (AWG) copper wire or 4 AWG aluminum wire. For cables running 100 feet or less, this is the recommendation. 6-gauge wire can safely carry 50 amps for up to 100 feet
@SolarEngineering
@SolarEngineering 3 ай бұрын
According to the NEC 310.16 Ampacities of Insulated Conductors with Not More Than Three Current-Carrying Conductors in Raceway: 6AWG: 55A (60C/140F) / 75A (90C/194F) Tesla Powerwall 3 can do continuous 11.5kW, which is 48A. We have to derate 60A breaker by 20% because it's continuous load, so we are getting 48A. Hopefully it's answer question.
@unclegeorge7845
@unclegeorge7845 3 ай бұрын
​@@SolarEngineering 55 Amps is not 60. But your inspector bought it so WTF? I don't think this would fly in Washington state. Onward and upward. PS: 60C/140F is burning flesh. That's why we set hot water to 125F out the tap.
@user-oc3xx8rn7z
@user-oc3xx8rn7z 3 ай бұрын
Can I see your electrical diagram?
Inside Tesla Powerwall 3
16:20
SolHome
Рет қаралды 47 М.
Ouch.. 🤕
00:30
Celine & Michiel
Рет қаралды 27 МЛН
Опасность фирменной зарядки Apple
00:57
SuperCrastan
Рет қаралды 12 МЛН
Slow motion boy #shorts by Tsuriki Show
00:14
Tsuriki Show
Рет қаралды 10 МЛН
WHY I REMOVE SOLAR
14:10
Solar Goat
Рет қаралды 96 М.
Have we been doing Solar wrong all along?
13:30
Undecided with Matt Ferrell
Рет қаралды 1,8 МЛН
Installing 2 Tesla Powerwall 3 with 9.7kW solar. Full home backup.
8:01
How Many Solar Panels Are Needed To Charge A Tesla
8:07
Everyday Solar
Рет қаралды 102 М.
Is Solar worth it? My Experience 2 Years Later
11:57
Smart Home Solver
Рет қаралды 79 М.
Tesla's Powerwall 3 & Solar | What I Wish I Knew
14:34
Ryan Shaw
Рет қаралды 161 М.
Tesla Solar Roof Review: Was it Worth It?
30:27
Marques Brownlee
Рет қаралды 12 МЛН
Запрещенный Гаджет для Авто с aliexpress 2
0:50
Тимур Сидельников
Рет қаралды 1,1 МЛН
Look, this is the 97th generation of the phone?
0:13
Edcers
Рет қаралды 8 МЛН
Better Than Smart Phones☠️🤯 | #trollface
0:11
Not Sanu Moments
Рет қаралды 19 МЛН
Bluetooth connected successfully 💯💯
0:16
Blue ice Comedy
Рет қаралды 1,9 МЛН
Todos os modelos de smartphone
0:20
Spider Slack
Рет қаралды 65 МЛН