Waiting for this to release in Australia. The variable output modes are a nice feature. The cost for installation here will be interesting. I want to change my 8Kw Fronius inverter to a Powerwall3 if it makes sense money wise . The waiting list here will be huge I imagine.
@Heatable4 ай бұрын
Hopefully not too long to wait! We can see a huge market for replacement string inverters, largely due to power flexibility, storage capacity and one warranty.
@torbenjacob5459Ай бұрын
The PW also supports a secondary solar panel system connected as AC input, so you can also just extend your existing system with a PW3 and a new solar array or 3 😊
@edc15694 ай бұрын
power = kw, energy = kwh, you don't store power, you store energy. This stuff is already really complicated for the average consumer, helps to use the right language.
@Heatable4 ай бұрын
Thanks for pointing this out, we'll pass your comment on to the team.
@polla22563 ай бұрын
To the average consumer that's just semantics. "Box makes things go" can be power or energy as far as the average meat bag is concerned.
@stephencrowther524Ай бұрын
en.wikipedia.org/wiki/Power_(physics)
@AllenHart9994 ай бұрын
Good video as always.
@Heatable4 ай бұрын
Thanks Allen :)
@PVOK2324 ай бұрын
Very good video, please keep the content coming. I’d like to see more solar panel installs that have shade problems.
@Heatable3 ай бұрын
Thanks for the suggestion! We'll see if we have any coming up that encounter any shading issues :)
@Animosity67924 ай бұрын
Have placed my order for PW3 and solar with Heatable - looking forward to it!
@Heatable4 ай бұрын
Great news, we're expecting 150 units to land mid-August. The team will keep you updated as and when they land.
@twtubeify2 ай бұрын
How did it go?
@Animosity67922 ай бұрын
@@twtubeify install booked for early next month, so it hasn't yet!
@PiratesBlackVTi2 ай бұрын
Got my Heatable installation date for my pw3 and solar roll on 7th October 😊
@Heatable2 ай бұрын
Roll on October 🙌
@PeaceChanel3 ай бұрын
Thank You for All that you are doing for our Planet Earth.... Peace.. Shalom.. Salam.. Namaste 🙏🏻 😊 ✌ ☮ ❤
@Fisherman2k2 ай бұрын
Are IQ8 inverters still required if this has a hybrid inverter? The start up voltage for the Powerall is less than the Enphase inverters?
@carlfielding20824 ай бұрын
Another good video as always! Can you please do a bill comparison video on Efficient boilers vs Hybrid Boiler. I know they always use the cheapest option but just confused as surely gas is always the cheapest option. Needs explaining pleaae. Really looking at getting one but can see no comparable videos
@NathanJones-cq1dz4 ай бұрын
Great video as always. I am currently considering a qoute for a further 18 panels on top of 8 already ordered for the garage. One of your points made in the video is the benefits of start up voltage providing the benifits of micro invertors. My qoute includes a tesla powerwall 3 as well as 18 enphase microinvertors. Why would I need both apart from the ability to monitor each panel individually with the microinverters?
@Heatable4 ай бұрын
Hi, yes Telsa have stated they'll be near the performance of Enphase (without the optimisation or warranty). We haven't had the opportunity to run any comparison tests yet. We'll share any information as we get it. Did Heatable install your first system?
@NathanJones-cq1dz4 ай бұрын
@@Heatable Heatable will be installing the first system once my DNO clearance comes through.
@Heatable4 ай бұрын
@@NathanJones-cq1dz Great news!
@PiratesBlackVTi4 ай бұрын
Just a quick question so for me I would want the full 11kw discharge rate as I have a 10.5kw shower , but your saying that the grid decides that for me ? Or you talking about the amount of solar I can send back to the grid ?
@paulnextlevelbusiness22574 ай бұрын
He is talking grid. The battery can output max capability to house for your shower. I have 2 x 5kw PW2 so 10kw max supplied to house. You can’t however export 10kw to grid unless you get permission for that value.
@PiratesBlackVTi4 ай бұрын
@@paulnextlevelbusiness2257thank you for your reply 👍🙏
@andy98414 ай бұрын
@paulnextlevelbusiness2257 Do you mean the frid wont let you dump 10kw in one hour, but you could for example drain the battery over three hours at 3.3kw?
@paulnextlevelbusiness22574 ай бұрын
@@andy9841 yes, depending on what export approval you have the unit gets configured to stay within that limit. Limits vary hugely between locations as grid quality varies, most people get 3-6kwh export limit range, our area seems good so we got 17!
@Heatable4 ай бұрын
Hi, thanks for your comment. Grid approval is generally broken down in to two parts. Demand (charge rate) and export (energy sent to the grid). We'll apply for the full 11.04KW for both and see what comes back, they may allow 11KW demand & 11KW export, or 11kw demand and say 5KW export. Sometimes they'll only approve a lower demand too. We're very experienced with all of the DNO's. Feel free to have a chat with one of the team for any advice :)
@tajdvl-advocate61133 күн бұрын
What about backup generator support?
@bobmamipoko4 ай бұрын
Thank you for informative video.
@Heatable4 ай бұрын
Thanks for your comment Bob - glad you enjoyed the video!
@andy98414 ай бұрын
How well does this integrate with the REA Fusion 2 panels you sell? Can they be added straight to the PW3 or would you still recommend the micro inverters? If you dont need the micro inverters, and I read the installation time is hours less, I'd imagine this would be a good cost saving?
@paulnextlevelbusiness22574 ай бұрын
@@andy9841 PW can have almost any panel added direct to it. REA are good panels (we have them plus other non-Rea on another array) for low light and winter conditions, peak summer power not so good but overall year round should win. Microinverters are expensive so PW3 would save money on those but your own shading/orientation etc would determine whether worth while. If no shading issues I would go straight into PW3 and save the £
@andy98414 ай бұрын
@paulnextlevelbusiness2257 Thanks for the reply Paul. I guess the only thing I'm missing out on would be the per panel generation stats. No big deal I guess
@Heatable4 ай бұрын
Hi, thanks for your comment. Paul has nailed the answer here - We can install a PW3 either AC coupled (with micro's) or DC coupled (DC straight into the PW). We have both versions of the REA panel. We got caught off guard with demand but we're expecting 4000 of each type in WC 29/07.
@StephenPBishop4 ай бұрын
@@Heatable Are you able to make a video showing the pros/cons of the REA Fusion 2 panels on a PowerWall 3 AC coupled (with micro's) vs DC coupled (DC straight into the PW3)? I understand from your other videos the benefits of an AC coupled system (with individual panel solar generation and panel monitoring via the Enphase app being one of them). Do you have any customers that have the the REA Fusion 2 panels and a PW3, that have the panels DC coupled (DC straight into the PW)? I assume you cant mix the two coupling types - ie you can only have one coupling type? Are all 3 strings you mention at 04:13 DC only.
@Heatable4 ай бұрын
@@StephenPBishop He Stephen, thanks for your comment. We have a video planned although we don't expect this to hit the channel for a month or so. We do have a video coming shortly with a DC/AC comp. We don't have any customer with REA - PW3 yet, first one is going in shortly. We got caught a little of guard with our panel stock but 4000 of each are due anytime now.
@tonyt74024 ай бұрын
Can you install this in a garage that is part of the house? Is there a fire risk or are LPF cells not a problem when regularly charged to full on hot days?
@Heatable4 ай бұрын
Hi, yes we can install on attached or detached garages. LFP is very safe, plus the PW3 has cooling chimneys to manage temps. 👍
@3815rockape4 ай бұрын
Great video, terrific production values. Question please. I have a solar array, from early 2011 with a very high FIT payment level. Can I fit a Powerwall and still receive the same level of FIT? Also could I have another solar array too, even if it needs to be separate from the original and still receive the FIT for the original set up. Sorry for so many questions, but I'd really like a Tesla Powerwall and if possible more solar. But I'd not want to sacrifice the very good FIT I'll receive for another 12 years.
@edc15694 ай бұрын
I believe the powerwall 3 can work just like the power wall 2 and soak up excess generation from your existing FIT inverter. You would need to keep your existing inverter so your FIT generation is metered. You could also add additional solar directly to the PV connections on the Powerwall 3. There will be some combined limitations but I suspect it could pick up 5kW from your existing inverter and approximately another 15kW (maybe a little less) from its internal PV connections, which is a lot of power for a 11kWh battery.
@Heatable4 ай бұрын
Hi, thanks for your comment. The team are really working hard to improve the content. To answer your FIT question - You can only replace the inverter of a FIT system with the same KW rating (PW3 should have a rating suitable). You can add storage, either DC or AC coupled without affecting FIT criteria, you can also charge from the grid on cheap rates. You cannot - increase the size of the inverter that array is coupled too or export battery energy and be paid under SEG. Re the other array, we can fit a microinverter system, then AC couple those to the PW3, this will give the full power benefit and wont affect SEG. Please contact the team if you would like to know more.
@PiratesBlackVTi3 ай бұрын
When you were talking about the pw3 discharge rate and “quote” you can choose your own setting? Is that changeable in the app for the consumer or done on installation day by the installers only.?
@Heatable3 ай бұрын
It's done on commissioning, it can be altered at a later date remotely by a Tesla approved engineer.
@MrSwift053 ай бұрын
I believe they are working on an update so Powerwall 2 and 3 will work together
@colinfieldgate47194 ай бұрын
I note there is a Gateway 2 and a Gateway 3. I understand that the latter is simpler / cheaper and can only do whole house backup. But is a Gateway needed at all if you don’t want / need home backup (which is an off grid capability that has an EPS function to deal with power cuts)?
@Heatable4 ай бұрын
The Powerwall 3 requires a gateway to work, as it doesn't just provide home backup but also monitors and manages the system production.
@colinfieldgate47194 ай бұрын
@@Heatable Thanks. I am clarifying a quote I have had for a PowerWall 3 system, which stated that EPS wasn't included. Surely, if a gateway is required (which is what I thought) it must be able to provide EPS, mustn't it?
@markabbott5746Ай бұрын
What about the warranty? Is the built in inverter covered for the same length of time as the battery? Inverters normaly have a much shorter warranty.
@HeatableАй бұрын
Hey Mark, the inverter is also covered under the 10 year warranty!
@freibuis4 ай бұрын
if the gateway is there.. then why does it have regulations around how much battery varible output you can have? Isnt that the whole idea of the gateway to isolate you from the grid in the first place?
@shabbbsy4 ай бұрын
Huh, actually good question, curious about this myself.
@markbooth4 ай бұрын
The Gateway is the external interface to the grid. It does not affect the discharge rate to your house, only the level the energy provider will accept back into the grid in your area.
@gaza232225 күн бұрын
Does the Gateway automatically switch to battery if there is a power cut?
@Heatable25 күн бұрын
Yes. You can customise your minimum battery charge too for this event. For example, if you were to always use your battery, in the event of a power cut you might not have enough storage to tie you over, so you would programme your battery to never drop below 20%.
@otooleniall4 ай бұрын
Great video. Such a shame we can't get them in Ireland.
@Heatable4 ай бұрын
Ahh, that's crazy. Are you able to get the PW2?
@otooleniall4 ай бұрын
No Powerwall at all. Have an order with Tesla for 5 years and haven't heard a peep from them
@WhiteEvo64 ай бұрын
Does the Powerwall 3 work with 3 phase, it’s a real limitation with Powerwall 2 that only 1 phase is utilised. I’m in Australia and I want the Powerwall however installers are pushing me to BYD as my house is 3 phase. The BYD is terrible for software, doesn’t automatically switch over in power outages, it’s only benefit is it supports each phase
@Heatable3 ай бұрын
Yes, Tesla Powerwall 3 can support three-phase supplies up to 162 kWh. It has better three-phase support than its predecessor and most other residential battery storage systems, but it doesn't have as much storage capacity as single phase systems.
@grahamdaniel603521 күн бұрын
Questions i thought you couldn't stack powerwall 3? Only powerwall 2 can be stacked?
@Heatable18 күн бұрын
Yes you can have up to 5 expansion packs.
@dommendozaАй бұрын
why not separated backup port only 1 port grid and back combine? very bad for me
@IanB614 ай бұрын
On a new build VAT can be reclaimed. Your price will include VAT (and delivery) which is charged to the customer. So how could I the end client reclaim that VAT element?. Tesla are only supplying to accredited installers wheras other products like the Givenergy All in 1 can be purchased from a wholesaler with a trade discount and vat recovered back.
@PVOK2324 ай бұрын
There is no VAT on battery installs in the uk until Feb 2025
@IanB614 ай бұрын
@@PVOK232 Correct, but that is on supply and fit. On a new build you can claim back VAT. If tesla sold the PW3 to customers rather than authorised installers it would be £5,500 + VAT meaning I could reclaim the VAT element. The installer will be vat registered and therefore they claim the vat back themselves. Any renewable - say Vaillant Heat Pump is subject to VAT from the supplier which could be reclaimed
@thomasjacques52863 ай бұрын
Can I add them to my existing PV system that has Enphase IQ8A micro-inverters. My installer says they are not COMPATIBLE. Yet I keep seeing folks say they are.
@Heatable3 ай бұрын
Yes these Powerwall 3 batteries can be connected to existing solar arrays and paired with Enphase microinverters.
@kevinmatthews26204 ай бұрын
so is it possible for me with a g98 3.68kwh 10 yr old inverter on FITs able to swap out my inverter and slot this straight in, and increase my current solar pv from 4kwh (250w panels) to the max i can squeeze on my roofs all without any extra paperwork/notifications ???
@edc15694 ай бұрын
No as you need a MID registered meter on your FIT generation, so you need to keep your existing meter and inverter, you can use this with the Powerwall 3 though. If you went powerwall 3 you could add some additional solar to it with its PV connections, alongside keeping your legacy (FIT) system.
@Heatable4 ай бұрын
@@edc1569 Hi Ed, we have installed replacement inverters for FIT clients, retained the gen meter and installed a battery. Inverter sizes had to be as installed. Battery connections allowed. We require the client to seek prior approval before install.
@rmblue223 ай бұрын
Question: If you can only charge a powerwall at 5kW max then whats the point of being able to hook up up to 20kW of solar into one powerwall?
@Heatable3 ай бұрын
The solar can supply the house first, then any excess goes to the Powerwall (if it has capacity spare) the rest goes to the grid. The max charge limit is rarely going to be an issue for the average UK system.
@rmblue223 ай бұрын
@@Heatable Cool. Thanks for the explanation 👍🏼
@guringai3 ай бұрын
Can the PW3 backup a 3-phase power supply?
@Heatable3 ай бұрын
Yes, Tesla Powerwall 3 can support three-phase supplies up to 162 kWh. It has better three-phase support than its predecessor and most other residential battery storage systems, but it doesn't have as much storage capacity as single phase systems.
@lichbane013 ай бұрын
Can it do 3-Phase?
@Heatable3 ай бұрын
Yes, Tesla Powerwall 3 can support three-phase supplies up to 162 kWh. It has better three-phase support than its predecessor and most other residential battery storage systems, but it doesn't have as much storage capacity as single phase systems.
@getgadgetАй бұрын
i would love to say its great , but 20 days on after the install from heatable and its still not working. so far 0/10 from me .. I've just watched all of this , first there was no site survey done on my property to see what my current setup is and what option i many have ( i did tell heatable i had solar panels when i ordered the unit, my current solar setup has been completely ignored. So i am missing out the benefits of connecting direct to the power wall 3 ( when its working that is) , and avoiding my current older SOLIS inverter.. hmmm.............. i feel a bit short changed here by heatable. So my System is not working and should be installed more efficiently going by this video ..
@HeatableАй бұрын
Hello, please could you e-mail solar@heatable.co.uk so that we can review this?
@savagecub2 ай бұрын
There is no Z in the name Tesla ! Let’s work on that a bit.
@BrunoHeggli-zp3nl4 ай бұрын
Just buy a powerwalls from BYD!
@Heatable4 ай бұрын
Hi Bruno, we haven't seen or installed their products yet. Support is a big consideration though.
@adrianflower32302 ай бұрын
So, the Tesla Powerwall 3 can Turn Up to 11 🕚 ! 😮😮😅😅