Testing Continuity of a CPC method 1

  Рет қаралды 39,550

E Learning Resources

E Learning Resources

9 жыл бұрын

Testing Continuity of a CPC method 1
Check out our courses here:
www.wlc.ac.uk/subject/default....

Пікірлер: 17
@sergioswedenborg8746
@sergioswedenborg8746 6 жыл бұрын
As someone here already said, the Title says "Continuity test" but the video talks about "Isolation test", it's just a detail and a matter of changing the Title. I would like to say that for me, which English is not my mother language, I could understand perfectly what the teacher says in the video. He talks slowly and clearly which for strangers like me is very important!
@darrenhill9931
@darrenhill9931 7 жыл бұрын
OK there is a few comments on here that suggest you havent done a thorough test but ive finally found a guy that explains this stuff with clarity, and takes in to consideration the newby's out there,I will be subscribing and hope that all of you vids are equally as explanatory. thanks
@chucky1077
@chucky1077 5 жыл бұрын
Strappers need testing too!!
@akeeebhaanif
@akeeebhaanif 8 жыл бұрын
absolutely brilliant video, just that on the testers I use I would look for >1000 ohms
@mahmoudarafa4098
@mahmoudarafa4098 9 ай бұрын
Do you know what’s the meaning of error 4 code
@fro0tyl0opy87
@fro0tyl0opy87 6 жыл бұрын
Sorry to be off-topic but to play the video at the original speed, simply increase from 'normal' to '1.25' which can be found in settings :)
@TheNorhalim
@TheNorhalim 7 жыл бұрын
you very good
@passargod
@passargod 8 жыл бұрын
switches were all open or off position, so test was incomplete, it did not cover up to the rose, also didn't like that screw-driver, looked unprotected
@fro0tyl0opy87
@fro0tyl0opy87 6 жыл бұрын
It's a great video though by the way
@ef7480
@ef7480 2 жыл бұрын
Light switches should be on to test the cable drops...👍
@GeeBag
@GeeBag 9 жыл бұрын
Wrong name of video
@asef698
@asef698 6 жыл бұрын
Greater than 1 mega ohm is technically a pass
@azajakal9614
@azajakal9614 8 жыл бұрын
greater than 1000 Mega ohms
@Dog-whisperer7494
@Dog-whisperer7494 3 жыл бұрын
Wrong wrong wrong, Insulation resistance test should be all loads removed and all switches in the on position, you test between line and neutral line and earth neutral and earth , if there are any sensitive equipment in circuit that can’t be removed from circuit then test line and neutral combined and earth or test at 250v .
@phamr8647
@phamr8647 8 жыл бұрын
Test RCCB
@aurangjebgool8458
@aurangjebgool8458 7 жыл бұрын
Pha Mr aurangjeb
@user-yw6qb9tt7t
@user-yw6qb9tt7t 3 жыл бұрын
I have never seen so many critical comments . 80 per cent !? Its how learners like me learn though. Rubbish videos and more comments. Definitely a market for it. Oh i have not made a negative comment of my own. I did not like the way he suspended the tester. Not dangerous but odd
Testing Continuity of a CPC method 2
18:59
E Learning Resources
Рет қаралды 22 М.
New model rc bird unboxing and testing
00:10
Ruhul Shorts
Рет қаралды 27 МЛН
World’s Largest Jello Pool
01:00
Mark Rober
Рет қаралды 77 МЛН
Testing Continuity of a Ring Final Circuit
10:13
E Learning Resources
Рет қаралды 77 М.
The Essential tests - Continuity of the CPC
8:22
JPElectric
Рет қаралды 5 М.
Earth Continuity Test
5:43
Master Electricians New Zealand
Рет қаралды 39 М.
Tests for Ring Final Circuits
23:02
John Ward
Рет қаралды 244 М.
Initial Verification - Testing someone else's crap work
32:55
SparkyNinja
Рет қаралды 272 М.
Testing Insulation Resistance of a Circuit
9:08
E Learning Resources
Рет қаралды 41 М.
Earth Fault Loop Impedance Test & Prospective Fault Current Test
16:50
City & Guilds Electrical
Рет қаралды 678 М.
Continuity test on a ring final circuit
10:16
TransEuroEngineering
Рет қаралды 47 М.