Continuity of protective conductors including main and supplementary | Electrical Tutorial

  Рет қаралды 6,157

Universal Skills

Universal Skills

Күн бұрын

Пікірлер: 16
@peterwhittle3196
@peterwhittle3196 Жыл бұрын
Just done the Pv course with Gavin. Got to say the guy is a legend and literally the best tutor I’ve ever had. Thoroughly recommend these guys 🍻👍🏻
@UniversalSkillsGroup
@UniversalSkillsGroup Жыл бұрын
Great to hear! Thankyou for the feedback!
@Dog-whisperer7494
@Dog-whisperer7494 Жыл бұрын
Clearly explained, good video mate. Just two points to mention 1) GS38 doesn’t relate to the test instrument it only requires that the test leads are of an adequate length and the there is no more than 4mm maximum ideally 2mm of exposed tips. (2) when you null the test leads you are not removing the resistance of the leads as such , the MFT takes a reading of the leads resistance and a deducts it from the test , . The test lead and any conductor will always have a resistance . But a good demonstration and video 👍
@adampowell5481
@adampowell5481 2 жыл бұрын
Thanks for that! Very good demonstration
@UniversalSkillsGroup
@UniversalSkillsGroup 2 жыл бұрын
Thankyou! Glad it was useful!
@yousufkhan2906
@yousufkhan2906 3 жыл бұрын
Good video once again. Easy to follow and your explanation spot on thanks
@UniversalSkillsGroup
@UniversalSkillsGroup 3 жыл бұрын
Thank you Yousuf, we appreciate the feedback!
@ebrahimdaiyan5446
@ebrahimdaiyan5446 3 жыл бұрын
Thank you this has helped a lot 🙏
@UniversalSkillsGroup
@UniversalSkillsGroup 3 жыл бұрын
Glad it helped!
@Tryingtimes007
@Tryingtimes007 2 жыл бұрын
I’ve been here before, the struggle to remove the CPC was “funny “
@ebrahimdaiyan5446
@ebrahimdaiyan5446 3 жыл бұрын
Can you make a video playlist of all the dead tests please
@UniversalSkillsGroup
@UniversalSkillsGroup 3 жыл бұрын
Hi Ebrahim, we recently uploaded a new video on our channel talking through the testing procedures! That explains some of the dead tests.
@Jay369
@Jay369 2 жыл бұрын
What's the maximum acceptable reading for this test?
@UniversalSkillsGroup
@UniversalSkillsGroup 2 жыл бұрын
The reading should not exceed 0.05 ohms. The reading would vary depending on the length of the bonding conductor.
@Jay369
@Jay369 2 жыл бұрын
Thanks for the videos and reply.
@Jo3yW
@Jo3yW Жыл бұрын
"Extrenerous" 😂
TESTING BONDING & EARTH CABLES - WANDER LEADS & CALCULATIONS
14:58
LEARN ELECTRICS
Рет қаралды 12 М.
Flipping Robot vs Heavier And Heavier Objects
00:34
Mark Rober
Рет қаралды 59 МЛН
Fake watermelon by Secret Vlog
00:16
Secret Vlog
Рет қаралды 18 МЛН
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 3 МЛН
Ring continuity | Step One, two and three. (49)
14:06
J Beck Electrical
Рет қаралды 11 М.
Continuity of CPC on a radial circuit - R1+R2 & R2
13:42
Residual Electrical
Рет қаралды 18 М.
Safe Isolation Procedure | Electrical Tutorial
8:04
Universal Skills
Рет қаралды 1,8 М.
Continuity of protective bonding conductors & equipotential bonding explained
27:03
Continuity Testing for Electrical Installations
16:58
John Ward (jwflame)
Рет қаралды 319 М.
Flipping Robot vs Heavier And Heavier Objects
00:34
Mark Rober
Рет қаралды 59 МЛН