No video

Testing refrigerator compressor LG, Samsung, Whirlpool...

  Рет қаралды 209,299

YourSelf

YourSelf

Күн бұрын

Пікірлер: 477
@mwilliams3447
@mwilliams3447 2 жыл бұрын
FIXED!! Refrigerator clicking on/off nonstop,and finally quit all together. This testing assured me my compressor was good. Start relay was rattling, replaced. Refrigerator still did not come back on, just heard clicking on/off at the circuit board on back, but that didn’t start happening right away.Finally I unplugged, worried it would burn up the board. Next morning, I plugged it back in, still nonstop clicking ever second at the board. By now, I don’t care if it burns up the board! (09 kitchenAid). As the morning went on , I could hear the compressor want to start, but, in a nano second the circuit board would click again, and shut it down from starting. This slowly build up where the compressor came on for a few seconds more and board would click it off again. Finally after hours of that building up of the compressor time, and less circuit board time, it just started running full speed, and very quietly. It’s be running 2 hrs now, I’m going to leave the refrigerator closed for 24 hrs and see if it’s going to continue running before pushing back into space. (note: before my fix, I had 2 different service people come out, one said my refrigerator relays was on the the board and my refrigerator didn’t have a relay to replace, so, board was replaced, did not fix; the other said he didn’t know the cause, cause at the time the clicking was intermittent and he’d have to hear it, even though I had audio.) By the way , I’m a 67 single women that relies heavily on Utube videos, thank you for taking the time to share your knowledge. Hope what I share, can help someone.
@Your-Self
@Your-Self 2 жыл бұрын
Glad it was helpful!
@pumpkinpeanut1
@pumpkinpeanut1 Жыл бұрын
This is one of the best videos on how to check your compressors that I have found on KZbin. Thank you for such a great demonstration!
@Your-Self
@Your-Self Жыл бұрын
Glad it was helpful!
@davidbeaumont4455
@davidbeaumont4455 Жыл бұрын
Hi. Your videos and your narrative is by far the clearest as far as diagnosing these LG fridge issues. Thank you for them. So my compressor is "running". It sounds healthy. Not hollow and not clicking like a thermal issue. Condenser fan is running and both fridge and freezer fans function in run mode and during test mode. My pcb doesn't have an LED. So no flashes. I get a code "22" in the 2nd phase of diagnostic which can mean start relay or PCB, but compressor is running. I'm willing to spend the $300+ to change board and relay, but not another grand to replace compressor. What's your beat guess? I'd be happy to compensate you for your time. Thank you so much. Dave Beaumont
@Your-Self
@Your-Self Жыл бұрын
Code 22 is just a notification that you are on the 2nd phase (33 the 3rd phase). You didn't mention the model number or if it's a Linear compressor. If it is Linear, I'm afraid you have to replace it. Or there is a small chance the refrigerant gas has leaked out. If it's not Linear, there is a higher chance of a gas leak. Either way an expensive repair. But if it's under 5 years old, LG may replace the Linear compressor free.
@djemorekcuf8304
@djemorekcuf8304 4 ай бұрын
Nice one i know the result of equal resistance~thanks dude!♥😮🎉
@danielshareck6486
@danielshareck6486 3 жыл бұрын
Really nice job on this video. After looking at videos for two days this was the best and most straight forward to test my LG linear compressor. Thank you!
@Your-Self
@Your-Self 3 жыл бұрын
Glad it was helpful, and thanks for watching!
@jogindergill2373
@jogindergill2373 2 жыл бұрын
Here is Gill I really appreciate your video explains clearly to check compressor good job. I am requesting your help to know how to check inverter on BLDC type compressor with inverter board
@curatinghumanism
@curatinghumanism Ай бұрын
Exactly what I needed. Thank you!
@Your-Self
@Your-Self Ай бұрын
Glad it helped!
@darrenmichaels
@darrenmichaels 4 жыл бұрын
Thanks so much for this! It saved me from forcing a tech to come to my home during a pandemic.
@Your-Self
@Your-Self 4 жыл бұрын
Glad it helped, and thanks for watching!
@astromaxx7771
@astromaxx7771 2 жыл бұрын
Thank you! It looks like my old school compressor works! Now I need to change the relay and overload and hope it works again. Thx again!
@jastak
@jastak Жыл бұрын
What a great, informative video! Here is my quandary: I have a kegerator with an old school compressor. Found the unit warm one morning. After diagnosing I replaced the relay and start capacitor. The unit ran for a day or so and then did the same thing. I can hear the overload clicking. There is a visible arcing at the connection to the overload when this happens. Again, new components. I manually ran the compressor by taking a power cord and connecting power to the C and M and then jumping the S to get it going. This works fine. Measured resistance on the terminals and got 6.2, 14.7 and 20.9. Not sure what to check next? Does the compressor have a “dead spot” that causes it to have difficulty starting after it stops a few times? Is it just overheating and eventually failing ? Trying to decide if I trash this thing. It is a pretty pricey unit. Hope someone can help. Thanks!
@jijoe4257
@jijoe4257 4 жыл бұрын
Wow...I just subscribed. This video was so well done for a newbie like me !! Very well explained and shown !! My start relay, overload switch and compressors were the same ones you were checking. I have only used a multimeter once before, but you made it so easy to learn to use it. My meter started higher then would go down some...hopefully that is normal?? My readings were about 5.1 on left and 4.1 on right. The two top pins were 8.8 , but I guess should be 9.2 ?? It is an LG bottom freezer refrigerator and the freezer will only get cold. The fan in the back is running and the compressor is hot. Any more suggestions would be greatly appreciated. Thanks so much !! Joe
@Your-Self
@Your-Self 4 жыл бұрын
Assuming that the freezer is getting cold (around 0°F), would indicate that the compressor is good! Part of that cold air should travel to the fridge section through a hall or a damper door on some models, with the help of a freezer-fan. So it's best to take your freezer apart and see if the fan burned out, or got stuck in the ice due to a bad defrost system, or the damper door is not working. Thanks for watching and commenting!
@jijoe4257
@jijoe4257 4 жыл бұрын
@@Your-Self Thanks so much for getting back to me so soon. I will check those things tomorrow.
@themodelrailwayrepaircentr297
@themodelrailwayrepaircentr297 2 жыл бұрын
At last ! An easy to follow video…. Thanks very much
@Your-Self
@Your-Self 2 жыл бұрын
Thanks for watching!
@heisnothere1786
@heisnothere1786 2 жыл бұрын
Thank you for such clear post. I have the LG linear compressor.so many of posts refer to compressor relay inside the left cover. mine has the overcurrent device only, yet I can hear a relay but the compressor doesn't start. does the relay exist elsewhere TY.
@Your-Self
@Your-Self 2 жыл бұрын
LG linear compressors don't have a start relay, only an overload device. The main electronic board controls the compressor. Try to run the Test and see if the compressor starts as on this video... kzbin.info/www/bejne/bWHcZ2SJpsSBi5I
@greatdane3343
@greatdane3343 10 ай бұрын
Great explanation! Thanks for sharing 👍
@Your-Self
@Your-Self 10 ай бұрын
Glad it was helpful!
@greatdane3343
@greatdane3343 10 ай бұрын
@@Your-Self my results were a bit different though. 17.8, 15.8, 32.8 on an Embraco ECR60HLP. Not sure if it is ok?
@Your-Self
@Your-Self 10 ай бұрын
Some compressors have double-digit readings. It's normal.
@greatdane3343
@greatdane3343 10 ай бұрын
Thanks for the response@@Your-Self
@aregularguydoesstuff4157
@aregularguydoesstuff4157 2 жыл бұрын
Excellent explanation! I ordered a relay and think it will fix the problem.
@Your-Self
@Your-Self 2 жыл бұрын
Good luck!
@aregularguydoesstuff4157
@aregularguydoesstuff4157 2 жыл бұрын
@@Your-Self Parts arrived and all I had to do was change the overload protector. Thanks again!
@Your-Self
@Your-Self 2 жыл бұрын
Good to hear it!
@boashna
@boashna 3 жыл бұрын
anybody can answer this my system uses overload and ptc system. I am not sure if I use the correct ptc but I hear and see the overload activited and working. is that mean the ptc is correct and motor stuck .. what happens if ptc fits but wrong ..
@Conservchick
@Conservchick 2 жыл бұрын
Great job on this video. Helped me a lot. Thanks.
@Your-Self
@Your-Self 2 жыл бұрын
Glad it helped!
@technicianusa
@technicianusa 10 ай бұрын
On last one, linear should be not 0.0, but Infinity sign. But anyway, thank you for the video.
@spencerthomason6558
@spencerthomason6558 2 жыл бұрын
Great video. Thank you. I assume that if I get no reading at all with a linear compressor, it's dead?
@dereckdean578
@dereckdean578 3 жыл бұрын
Very informative and helpful ,thanks much.
@Your-Self
@Your-Self 3 жыл бұрын
Glad it was helpful!
@dougpeters1625
@dougpeters1625 2 жыл бұрын
Outstanding Tutorial!
@Your-Self
@Your-Self 2 жыл бұрын
Glad it was helpful!
@user-il1rk6ur3r
@user-il1rk6ur3r 3 ай бұрын
Hello If the compressor work 5 seconds and stop , I was change the relay and overload , but the problem is still
@Your-Self
@Your-Self 3 ай бұрын
Typically, the problem would be with the start relay. But since you already changed it, the issue could be with the compressor itself.
@davidvohoang7089
@davidvohoang7089 3 жыл бұрын
Hi Thank you for the video. My Kenmore frig is giving up last week. Fan running, clean condenser, etc. I replaced the relay (prior to watched your video). The compressor does not kicked at all, and if keep on plugged, it got fairly warm. Zero cool air produced. Bottom door frig, model 795.71302.011, compressor sticker showed LG MQ53LAUM. Testing followed your video: 1) No jumping # if touch both on copper tube 2) No jumping # if touching copper tube and the base that attached the pin 3) between pins are 7.8, 5.4 & 11 Is this old school compressor? The hardware look just like your in the vid. The compressor has no mention of “linear” Is the compressor death ? Thanks again for the great info and reply
@Your-Self
@Your-Self 3 жыл бұрын
The resistance between 3 pins seems normal. But I'm not sure if the compressor is shorted to ground or not because your test was inconclusive. You should get some numbers jumping when you scratch the copper pipe with both leads. But you should NOT get any jumps from that copper pipe to any of the 3 pins. If you already replaced the Start Relay, try replacing the white Overload as well. You can test your old start relay in between small holes, probably marked 5 and 6. If you get somewhere 5 to 25 ohms (at room temperature), your old Start relay is good.
@randalfuller8164
@randalfuller8164 7 ай бұрын
Great video. I have a linear compressor and tested each contact and no reading. The compressor is vibrating but the unit is not cooling. Does this mean I have a bad compressor. LG frig 7 years old. Thanks
@Your-Self
@Your-Self 7 ай бұрын
Since the compressor is vibrating, you should have at least one reading (possibly a bad multimeter). However, the LG linear compressors can fail the way you described. Running vibrating but not cooling (crack in the reed valve). A Less common issue with LG units is a refrigerant leak from the system. Which would have the same symptoms. Either way, it's an expensive repair (((
@marynasr3569
@marynasr3569 4 жыл бұрын
Thank you for the video. I have a LG LFXS29626S French Door with a Linear Compressor LGB075LBNA (~ 4 years old). Fridge runs but does not cool (Freezer nor Refrigerator). Compressor does not get warm, lines do not get hot or cold. Condenser and evaporator fans run (jumpered door out), blows warm air inside fridge. No fault codes or alarms. Made sure not in DEMO Mode. Replaced main PCB board and Run Capacitor. No change. Checked continuity on thermal overload, its good (not open). Installed pierce valve on low side, has refrigerant, not low. Checked the resistance between top and bottom left prong on compressor, measured 8.6 ohms. $240 in parts trying to troubleshoot and repair. In your opinion, is the compressor shot? Anything else you recommend? Thanks in advance for any advice.
@Your-Self
@Your-Self 4 жыл бұрын
I'm afraid you are correct about the compressor being shot. LG Linear compressors have a weak internal valve. So it's typical for the compressor to just idle and not compress the gas. Compressors under 5 years old are covered by LG full warranty, but after installing the piercing valve on the low side, I'm not sure if they will replace it for free. Good luck!
@starobinful
@starobinful 3 жыл бұрын
Could you please explain what does it mean compressor shot ? And also what does it mean compressor shorted ? Thanks
@flyin4food931
@flyin4food931 Жыл бұрын
I have a 1yr old 33 bottle wine fridge that quit cooling. all fans, lights and panel are working. I've checked and the pins are opposite from your diagram like a triangle. Top pin to the left pin 2.5. Top pin to right pin 0. Left pin to right pin 2.5. I've also checked the relay and show 0 resistance. Could the compressor and relay be both bad?
@magstiger
@magstiger 3 жыл бұрын
In your professional opinion, who makes the better compressor? I need to purchase a new refrigerator and I'm starting to think that I should stay away from LG.
@Your-Self
@Your-Self 3 жыл бұрын
According to LG, they improved their compressor last year, but we still don't know if it's any better than before. BLDC compressors are pretty reliable and efficient. But the circuit board (inverter) running them, may fail in about 5-10 years. It costs about $250-$350 to replace them yourself. Basic compressors are the most reliable but not as efficient and a bit loud.
@magstiger
@magstiger 3 жыл бұрын
@@Your-Self I appreciate your input. I'm going to look more into Whirlpool. Thank you for your response and for your content.
@bravucod
@bravucod 2 жыл бұрын
Love the video my compressor is shorted to the ground 😭
@Your-Self
@Your-Self 2 жыл бұрын
Sorry to hear that
@bravucod
@bravucod 2 жыл бұрын
@@Your-Self thanks for replying and for posting such a good tutorial
@jimvanderlinden7249
@jimvanderlinden7249 3 жыл бұрын
Can you take the wire off the thermostat and tie it to the compressor to see if the thermostat or the compressor is bad?
@larrymansfield9393
@larrymansfield9393 9 ай бұрын
I was just about to head to the big box store and buy a new fridge until I came across your video. I get a good ohms reading of 7.0 to 8.0 on the linear compressor. My problem is no cooling throughout the entire fridge. All fans work. Any advice is greatly appreciated.
@Your-Self
@Your-Self 9 ай бұрын
A compressor can fail either electrically or mechanically. Since you have a good reading, most likely, your compressor has failed mechanically. That is typical for an LG linear compressor. There is a small chance that the refrigerant has leaked out from the system. And to know for sure, you need a tech to install gauges to check the pressure. Either way, it's an expensive repair.
@larrymansfield9393
@larrymansfield9393 9 ай бұрын
@@Your-Self Just my luck, hey thanx for the response
@heisnothere1786
@heisnothere1786 2 жыл бұрын
Can't thank you enough- subscribed.
@Your-Self
@Your-Self 2 жыл бұрын
Glad to help
@user-ix9tj4fq1b
@user-ix9tj4fq1b 7 ай бұрын
Good afternoon, the video has been of great help but at the time of making the measurements I have 6.2 8.2 and 12.4, the last value should give 14.4 and gives something lower, could it be that the engine is damaged?, (tecumseh 335-ts-259 engine) I also did continuity tests and everything is fine. The fridge was working and began to hear a "click" until one day the fridge did not freeze more, today only turns on the bulb inside the fridge and sounds the "click" every so often, but my doubt is with the resistance values or I don´t know if the PTC may be the source of the problem.
@Your-Self
@Your-Self 7 ай бұрын
Your resistance measurement of 12.4 is close enough to be good. The easiest what you can do is replace the PTC start relay and see if it works.
@yankeehank1897
@yankeehank1897 7 ай бұрын
Thanks for the video! On the LG Linear compressor, at the 4:50 mark when you say there is nothing between the other 2 sides and you should not get a reading, your video shows 0 ohms. Should it read 0 ohms or is it actually an open circuit? Thanks!
@Your-Self
@Your-Self 6 ай бұрын
Good catch. There should be an open circuit between the other two sides.
@yankeehank1897
@yankeehank1897 6 ай бұрын
@@Your-Self Thanks for confirming!
@agr8884
@agr8884 4 жыл бұрын
Thanks for the video, I managed to to test my BLDC Frigidaire compressor properly. The compressor is not grounded and the readings between each pair of pins is 17.2, no more no less. This looks very high compared to your average reading for the compressor..so is my compressor shot? the model is fghb2844lf7. If the resistance is fince then I am guessing its the inverter relay board. But trying to make sure before I order one.
@Your-Self
@Your-Self 4 жыл бұрын
The resistance on your compressor sounds a little high, but not unheard-of. BLDC compressors are reliable in general, but inverters are not. The inverter board supposed to get 2 voltages in...120vAC to energize it, and a small variable 3-5vDC from the motherboard. If you can confirm those 2 voltages, but the compressor doesn't run, most likely a relay or something else on the inverter board got damaged. If you take the inverter board out, sometimes you can actually see the burnt marks on the front or the backside.
@canadian28
@canadian28 2 жыл бұрын
When i turn on my fridge LG .my breaker goes off I think my compressor ground short can you reply me back thank you
@Your-Self
@Your-Self 2 жыл бұрын
Possibly the compressor is shorted. But maybe the breaker is too weak. Get a long extension cord and plug your fridge into another room that has a different circuit breaker to verify.
@MrQuantumRay
@MrQuantumRay 5 ай бұрын
Can you please also show how to test wisemotion compressor.
@Your-Self
@Your-Self 5 ай бұрын
The wisemotion compressor is rare and weird. Unlike other compressors, it can stop running because there is a refrigerant leak in the system. It's difficult to figure out what the problem is for a DIYer. It's best to call Whirlpool authorized tech to troubleshoot it.
@jagerdave8861
@jagerdave8861 2 ай бұрын
Wow, thanks for the info. The comments have also been a help but I have yet to find the root cause. I have an old school Amana. Last night something suddenly started buzzing, not wake the dead loud but loud enough to hear it from another room. I unplugged the fridge and plugged it back in. The buzzing stopped but I heard a cyclical clicking every couple minutes. Fast forward to my investigation. The compressor is not running but gets hot. All fans run. The ptc relay does not rattle and there is continuity between the 5 & 6 female holes. The overload is separate and has continuity, although a bit of resistance. Is this an issue? I have not yet checked the capacitor as my DVOM does not have that capability. This is interesting. The cyclical click is actually 2 clicks. I hear the first click and the inside light dims a bit and the fan slows a bit. About 10 seconds later I get another click and the light and fan return to normal. This cycle is happening once a minute or just under. If I put a finger on the ptc and another finger on the overload, I feel the clicks more with the finger that is on the overload. I did the 3 pin resistance check per this video and although I didn't get 2 numbers that total the 3rd, at about 16, 12, and 8 ohms, I was as close as some others that have commented. Aside from the capacitor check, have I missed anything?
@Your-Self
@Your-Self 2 ай бұрын
How much of the resistance does your overload have? It should be close to 0... something between 0.0 - 0.4 is OK. If it's higher than that, check your multimeter leads against each other. Leads themselves may have some resistance in them.
@jagerdave8861
@jagerdave8861 2 ай бұрын
@@Your-Self I checked it again with a better meter and yes, it is almost nothing. I was also able to check the capacitor with the borrowed meter. It measured 11.8mf. That doesn't leave much unchecked.
@Your-Self
@Your-Self 2 ай бұрын
Yeah, it points to a seized compressor. Even if it checks out well with a multimeter, it can lock up mechanically. You could still try replacing the start relay just to rule it out completely. But looks like the compressor is bad.
@jagerdave8861
@jagerdave8861 2 ай бұрын
@@Your-Self have you ever used one of the compressor jump start kits that sell for about $15?
@Your-Self
@Your-Self 2 ай бұрын
I personally haven't. But a Hard-start kit can give you an extra boost to possibly unlock the compressor. You could try an RCO810 for a smaller/mini refrigerator. Or an RCO410 for larger/regular units. With a Hard-start kit, the compressor may start and run, but it can still overheat and cause problems. Just keep an eye on it.
@seeker9969
@seeker9969 2 жыл бұрын
Great job on the video :) if the linear compressor had a ohm reading on 9 and seems to be running (as there is no clicking and no cooling) would that be a no coolant issue even though its throwing a 22 code on a LG fridge, Thanks for your help
@Your-Self
@Your-Self 2 жыл бұрын
Are you sure it's throwing the 22 code? If you are running the Test from the small button on the PCB, it's just showing the second stage of the Test Mode. And the third Test will be 33. Typically, LG linear compressors run (vibrate) but don't cool when bad. If it's under 5 years old, LG may replace it absolutely free. The lower possibility is that the gas has leaked out from the system.
@sf6425
@sf6425 Жыл бұрын
I have exact same issue. Second Diagnostic test via PCB throws 22 error code. No error code on third test. Compressor vibrates all the time but no cooling. Temperature sensor and all fans checks out fine. One pair of Compressor pin shows 10 ohm resistance. Relay doesn’t rattle and compressor starts vibrating immediately without clicking. Out of ideas. Do you think I have bad compressor? It’s about 7 years old. Any idea on labor cost to replace as it has parts warranty on compressor. Appreciate your help.
@alleyoop5185
@alleyoop5185 2 жыл бұрын
Hi my problem is we had a brief power out age. When power resumed ,I smelled a burnt plastic smell. The fan worked but the compressor relay was fried. I have a 3 way so I hooked it up and I heard a brief start noise then nothing. I did the 3prong test on compressor and it checked good. Now I rehooked the power wires to the 3way but there’s no juice there at all when I turn fridge on. I checked the wall plugin and get 120 volts. Any ideas?
@davidmurphy9397
@davidmurphy9397 3 жыл бұрын
Thanks so much for this video, it was very helpful. I have a Kenmore Elite running a LGFLB075LANA Compressor. I'm getting no cool air from the freezer or fresh food compartments. The readings are 10 Ohms / 0 / 0, which I believe is expected. The compressor feels like it is running, it gets warm and there is a slight vibration. When I do the diagnostic test I can feel air coming from both compartments. I've replaced the start relay and get the same results. I also have a 3 n 1 start that I haven't used, but I suspect that won't solve anything. Given all that is the compressor most likely just shot? Unfortunately this fridge is about 5 years and 1 month old. Thanks again for the great video!
@Your-Self
@Your-Self 3 жыл бұрын
Since the compressor is actually running, the 3 in 1 is not needed. The warm air blowing in both compartments indicates some-kinda Sealed System issues. Could be a leak, restriction, or mechanically damaged compressor inside... which is most common for this compressor. In any case, an expensive repair :(
@davidmurphy9397
@davidmurphy9397 3 жыл бұрын
@@Your-Self thank you so much for the fast response. In your experience do you have any guesstimates on how expensive is expensive? (Ballpark). I think I’ve read the compressor itself is covered for 10 years, but not the labor? My experience with Sears on this has been extremely poor so far, and to even have a tech come look at it would cost $170. I don’t want to just throw money away for them to tell me the repair is an obnoxious cost. Thanks again, your videos have far and away been the best I’ve found on this topic.
@Your-Self
@Your-Self 3 жыл бұрын
While LG covers the compressor and labor for the first 5 years and parts only for 10, Sears has its own rules. The lowest you can expect to pay is about $350 for labor if Sears provides the compressor. Not sure if they will cover other items like Filter/Drier, Condenser, Evaporator if there is a leak. So the price can go up to $1000 very quickly.
@davidmurphy9397
@davidmurphy9397 3 жыл бұрын
I checked with Sears and their parts warranty is 10 year for the compressor and 5 year for the sealed system. The fridge is 5 years and 1 month old. Ugh. You seemed to think the symptoms I provided were a sealed system issue. Would the cost of repairing the sealed system + labor approach $1000 if the compressor was still good? Unfortunately it will cost $169 for Sears to even just assess and quote a price. Again, I really appreciate you taking the time to answer.
@Your-Self
@Your-Self 3 жыл бұрын
Unfortunately, there is no way to figure out if it's a bad compressor, a leak, or a restriction without a technician piercing the sealed system to install gauges. If the compressor is bad, it's actually the "best" and the most likely case scenario, and it's covered. If there is a leak on the LOW side, it's the worst-case scenario that may require the Evaporator, Filter, and possibly the Compressor replacement, which may not be covered in this case. And that's how you approach the $1000 bill. Tough decision.
@paulrockey830
@paulrockey830 3 жыл бұрын
Fantastic, thank you so much!
@Your-Self
@Your-Self 3 жыл бұрын
Glad you enjoyed it!
@kominares
@kominares Жыл бұрын
How about dual inveter,what readinds should be there?
@billyhorton8020
@billyhorton8020 4 жыл бұрын
I just seen your video, you seem very knowledgeable and helpful, thank you. I am working on a Kenmore Cold Spot Embraco em2z 80 HLT compressor The readings are 8.4 5.7 11.4 When I plug it in the compressor turns on but shuts off in a few seconds. I unplug and plug back in it does the same thing.
@Your-Self
@Your-Self 4 жыл бұрын
The resistance numbers are little off but could be due to inaccurate multimeter. If the compressor starts for a few seconds and stops, this could be due to a bad starting device. It may look similar to my starting device in the video, but it's a different type. You may have a TSD (Time Starting Device), which typically fails the way you describe. Try replacing it, and if that doesn't help, the compressor may be bad. Good luck!
@davidvohoang7089
@davidvohoang7089 3 жыл бұрын
Did you finally find your answer? I have similar problem. Thanks
@christofer99999
@christofer99999 2 жыл бұрын
Thank you very much for your video. I have lg with linear compressor and the freezer is not getting cold enough. The technician in my place is really bad. He already change the main board but still the same. I have it for almost 3 years. The measurements i found are 5.4-15,4-19,5. What do you think? Please reply!!
@Your-Self
@Your-Self 2 жыл бұрын
Some LGs have regular compressors installed. So your measurements should be OK. Did you buy your fridge new or used? Maybe somebody worked on it before and made a mess. The refrigerator could be leaking gas slowly on the LOW side. It may take a month or a year to leak out completely with reduced performance. The only way to prove it is for a tech to attach gauges to check the pressure inside. Make sure to clean the condenser coils near the compressor. I'm assuming all fans work well, right?
@christofer99999
@christofer99999 2 жыл бұрын
@@Your-Self the fans are working fine and i clean the condenser. It was new and on the door it says linear compressor with 10 years warranty. The tech just opened the cover inside the freezer and he said i can see the leak. My wife was at home then and he wanted to take it for a week to check. But he is very bad tech. I will have to pay him and he will do nothing. What do you suggest me to do? He replaced the main board at September and for 1-2 months it was okay but after that my warranty expired.
@Your-Self
@Your-Self 2 жыл бұрын
Hmm, if it says Linear on the door, the compressor should be Linear as well. Does it actually say Linear on the compressor itself? (it could be a small text, hard to see) Recently, LG extended the free Linear compressor replacement warranty to 5 years. And 10 years parts only. However, I'm a bit confused by your compressor situation, so not sure what to suggest.
@garyseitz758
@garyseitz758 Жыл бұрын
I don’t think mine is a a BLCD, no box behind it. But I have 7.5 ohms on all terminals. Do you think it’s toast? Thanks
@Your-Self
@Your-Self Жыл бұрын
If all terminals are equal at 7.5, that's probably a BLDC compressor. The inverter could be hidden somewhere with or without the box.
@garyseitz758
@garyseitz758 Жыл бұрын
@@Your-Self Thanks, but I don't see a box behind the compressor probably 20 years old. how would I find out what kind of compressor it is? it says LG MC57LAUM
@Your-Self
@Your-Self Жыл бұрын
I looked up the image of the label of this compressor, and it looks like a regular compressor. It's strange that all terminals are exactly the same so it's probably toast. On the bright side, it worked for 20 years... unlike newer refrigerators.
@garyseitz758
@garyseitz758 Жыл бұрын
@@Your-Self thanks
@whatfreedom7
@whatfreedom7 2 жыл бұрын
Any idea if current LG models have updated compressors that are more reliable than the linear problematic compressors?
@Your-Self
@Your-Self 2 жыл бұрын
New updated LG compressors have been around for a few years only. Unfortunately, that's not enough time to determine if they are any better than the previous version.
@mojtabaghambari4837
@mojtabaghambari4837 Жыл бұрын
Thank k you
@ironmule4254
@ironmule4254 9 ай бұрын
My relay clicked and over nite the compressor was warm not hot but the coils were not warm or cold?
@Your-Self
@Your-Self 9 ай бұрын
Try replacing the relay and see if it works.
@nigelchambers2617
@nigelchambers2617 4 жыл бұрын
What should be the voltage going to the linear compressor from the circuit board?
@Your-Self
@Your-Self 4 жыл бұрын
The circuit board supplies the compressor with a variable voltage based on needs. The typical operating voltage could be anywhere from 80Vac to 200+ Vac
@michaeldunne1348
@michaeldunne1348 3 жыл бұрын
This is great information. Our 10-year old LG 3-door stopped cooling overnight. The fan runs, but it doesn't look like the compressor is running. There is no start relay/overload plugged into the compressor, just a connector that goes to the grey (actually it's off-white) box mounted to the side of the fridge. Our compressor passed the short test - all three leads measured open when I put one lead on a compressor pin and the other on the copper pipe. However, when I measured lead to lead, I only had one measurement with a reading... but it wasn't on the "right side" winding, it was on the left and it measured 6.9 ohms. The top winding and the right winding both measured open. So, the question is, is the compressor bad? I ask because in your descriptions, my set up looks like a BLDC inverter because there is a grey (off-white) box to the left of the compressor. However, ours does measure similar to the LG Linear example, albeit on the opposite winding. I'm wondering because our unit is an LG, so perhaps the compressor readings are good and I need to test the start capacitor on the grey (off-white) box and/or maybe open the box and look for the start relay? If you're still monitoring this thread, I'd love some feedback before the service tech arrives tomorrow! Thanks :-)
@Your-Self
@Your-Self 3 жыл бұрын
You have one of the earliest LG linear compressor setups with a separate Main PCB and a Drive PCB (inverter box). According to your measurement, the compressor seems OK. You could run a Test Mode by pressing the button on the Main PCB, and see if the compressor and fans run like on this video: kzbin.info/www/bejne/bWHcZ2SJpsSBi5I Also, you may see a light on the inverter box flashing error codes
@michaeldunne1348
@michaeldunne1348 3 жыл бұрын
@@Your-Self well that's some (hopefully) good news! Compressors aren't cheap :-) We've had good service for 10 years out of this unit and I'd like to keep her going if I can. I ran the push button tests on the main PCB earlier and other than the fan motor coming on, the compressor seeming to not come on, and the front display showing 22, 33, 44 when I was cycling through the tests, it really didn't tell me much. I've got the inverter box apart and see the LED. I'll try to make it flash in the morning when I can reconnect the compressor power leads and plug the unit in. Does that same video link (above?) that shows the list of flashes that equal certain error codes explain how to kick off the tests? Thank you very much for your quick response!!
@Your-Self
@Your-Self 3 жыл бұрын
Yes, the same linked video with error codes. If the compressor is not running during the Test, the inverter box is probably bad, or the Main board.
@michaeldunne1348
@michaeldunne1348 3 жыл бұрын
So, with drive PCB visible and everything plugged in, I ran the tests using the button on the main PCB. The LED on the drive PCB did not illuminate or flash at any time during the test sequence. Generally, on first press, the fan speed increased and I saw 88 on the front panel. On the second press, the fan speed stayed high and the front panel showed 22. On the third press, the fan stopped and 33 was on the front display. Fourth press showed 44 on front display and heard some relay "clicks" on the main PCB. I ended up unplugging the mains and plugging it back in to reset and the fan came on normal speed. At no time is the compressor coming on. I've been unable to find the exact service manual online for our model and am suspicious about trying to troubleshoot further using a different (but close) model's voltage and test point guide. Any thoughts?
@Your-Self
@Your-Self 3 жыл бұрын
If you provide your refrigerator model number, I may be able to find the correct Tech Sheet to narrow down the problem to Main or Drive PCB.
@vvekrathod6685
@vvekrathod6685 4 жыл бұрын
Which is Best....? I'm Confused...🤔 Please Help Me...?!
@Your-Self
@Your-Self 4 жыл бұрын
Older, basic compressors are reliable, but noisy and consume more electricity. Newer BLDC (variable speed) compressors are reliable, but the INVERTER (gray box) is not, but you can replace it yourself if needed. LG linear compressors are quiet and efficient, but not reliable at the moment. They have an updated version of the linear compressor in 2019, but we don't know how long it will last.
@vvekrathod6685
@vvekrathod6685 4 жыл бұрын
@@Your-Self Thank You For Advice...😍💕
@Houstonpaki1
@Houstonpaki1 2 жыл бұрын
Great video. I have LG lfx25974sw from last 7 years. It stopped cooling. I checked both capacitors from panel, both good, fan and compressor working and from my left bottom to top was 7.5. However, coils are room temperatures and one of the compressor line does get slightly hot if let it running for an hour. My technician suggested that the compressor is bad. Any suggestions. I am very non-technical but gained a lot of knowledge from KZbin from people like you who actually share their knowledge to benefit other and I have benefitted Thanks. BN
@Your-Self
@Your-Self 2 жыл бұрын
It seems you've done everything you can on your part. The problem is with the compressor, the refrigerant leak or restriction. Any of these problems should be repaired by a tech and kinda expensive. So I guess it's time to decide if you want to fix it or buy a new one. If you have the receipt, LG may cover the cost of the new compressor, but you'll pay for labor.
@Houstonpaki1
@Houstonpaki1 2 жыл бұрын
@@Your-Self Thank yo for your reply. LG sent me correct compressor but wrong Board and after figuring that out got new board. Earlier tried the Wrong board which only sent power to compressor as other would not connect and it ran for few minutes and then died. Service man connected new compressor and put some Freon but the Compressor would not work and still does not work even after he put some hard start as he said that it by passes the Board but the compressor would not start. He does not pay any attention to my Please to check the capacitor, over load or relay. I have bought two Volta meters but don't know how to check the capacitor, relay and the overload. Other tech I cant get as he promises but no show. Any suggestions. If none that is OK. Thanks and Happy Holidays.
@spannerman3434
@spannerman3434 Жыл бұрын
Great video . I have a Westinghouse WSE7000SE , and the control module seems to have failed , fridge light was flickering , then turn off whilst the door was open , it was still staying cold , but then the fridge went dead , and the freezer light was the only thing working . I thought i would check the compressor before buying a new control buzz box , and the readings i am getting is 26.2+11.8 =38 , which makes sense , but they are all pretty high readings . Even though the value equation adds up , why would they be so high ?
@Your-Self
@Your-Self Жыл бұрын
The manufacturer of your compressor decided to go with the higher resistance wires. But the readings look normal. The flickering light points to a problem with the control board or the light itself. Also, a shorted (wet) DC fan motor, can overload the control board, so it can't supply power to the rest of the refrigerator... it gets pretty complicated with newer refrigerators. I guess replacing the control board would be a good first step without technician involvement.
@spannerman3434
@spannerman3434 Жыл бұрын
@@Your-Self The fridge is totally dead , only freezer light is working . The starter relay and overload are high readings also , but its a 240v fridge . I replaced the diode on the control board and will do the 35v capacitors , as they look swollen on the tops . THANKS for your reply .
@spannerman3434
@spannerman3434 Жыл бұрын
Hi Mate . I ended up replacing the zener diode and all four 35v capacitors and the fridge is perfect . It was your information that enabled me to do fix it , i am extremely grateful , thank you !!
@Your-Self
@Your-Self Жыл бұрын
Good to hear it!
@omlorz1680
@omlorz1680 3 жыл бұрын
Such a big help for us DIY folks! I have an LG linear, what does it mean if it reads at 9.2? Thanks in advance.
@Your-Self
@Your-Self 3 жыл бұрын
9.2 sounds normal, and if the compressor is not Shorted to Ground, it should be OK electrically. But it could still be damaged mechanically inside, depending on what your problem is.
@omlorz1680
@omlorz1680 3 жыл бұрын
​@@Your-Self It is cooling just slightly, not completely. I also followed your other video using the 'test and reset button' to confirm the evaporator fan/air flow works. The sound check, using your other video 'not cooling but running' points me to bad compressor. Now patiently following your tip to 'get your money back for not cooling LG fridge'. You are educating folks globally, heartfelt thanks from a DIYer from the beautiful island of Guam!
@Your-Self
@Your-Self 3 жыл бұрын
Since it's slightly cooling, the evaporator coils could be covered in frost/ice due to a Defrost Problem. I'd unplug the fridge for the full 24 hours, so the ice can melt. And then check if the cooling improved. But most likely, the problem is with the compressor itself. I'm sure Guam is a beautiful island, but not sure about LG warranty coverage on the island. Let us know if they can fix or replace it.
@omlorz1680
@omlorz1680 3 жыл бұрын
@@Your-Self I had performed the defrost process as well. Fortunately, LG extends warranty coverage here as it was purchased at the local Home Depot. Compressor is being shipped by LG USA as we speak.
@junaidquraishi9825
@junaidquraishi9825 3 жыл бұрын
@@omlorz1680 linear compressor is not durable according to various reviews on the internet. Is that the case with you.
@didodelima
@didodelima 4 жыл бұрын
U made it Simple thx a lot
@Your-Self
@Your-Self 4 жыл бұрын
Thanks for watching!
@kevindaniels9390
@kevindaniels9390 3 жыл бұрын
My Kenmore 795.72493.611 is not cooling fridge nor freezer. In test mode fans blow air in freezer not fridge. Also code 22 22 shows on display window. Is the compressor shot?
@OMNITEK
@OMNITEK 2 жыл бұрын
hi @yourself , first thanks for your great videos and thanks for your time, it's truly appreciated...i have a LG LFXS28566M around 4 years old, recently stopped cooling, everything seems to be working visually and audibly, lights come on..fans come on..compressor runs, i changed the relay with new one just to make sure...didn't do much...i pierced the vaccum side of the copper pipe with a "bullet piercing" thinking it might be low on freon, i followed all instructions on doing it and nothing , the pressure when i open the valve on all vids i watched reads negative or at least runs towards low as a vaccum, on mine it only goes as high as i release freon and stays there, i tried so many times to release and refill freon in hopes of it working but no luck so far, on the test from motherboard it gives me error "22"...and nothing else...no led flashes and no blown fuses....tested the compressor as you showed in this video everything checks except for the ground to pin which reads between 10-11...not 7.5 or 8...i am really lost at this point...any suggestion you might have would help...i really apologize for the lengthy comment, and thank you in advance for any suggestion you may have.
@Your-Self
@Your-Self 2 жыл бұрын
Unfortunately, these Linear compressors are very finicky. You must charge them with the exact amount of refrigerant gas as per the label. Also, it's very possible the compressor got weak and can't pump. So you may need a new one. Since you already have a bullet valve installed, check the Static pressure first (refrigerator unplugged). The static pressure should be around 50-60 PSI in a fully charged system. Then start the compressor, and the pressure should drop to around 0 PSI. If the pressure drops only by a little, let's say, down to 20-40 PSI, the compressor is bad. But if the pressure goes into a vacuum, there may be a restriction in the filter/drier or the capillary (thinnest) tube.
@OMNITEK
@OMNITEK 2 жыл бұрын
@@Your-Self thanks a lot, i tried the static pressure and it still says around 65-70 even after i turn on the compressor...as if it's not vacuuming at all...
@Your-Self
@Your-Self 2 жыл бұрын
Yep, sounds like an inefficient compressor. You need a new compressor and probably a software update to the main PCB board with a special LG jig.
@OMNITEK
@OMNITEK 2 жыл бұрын
@@Your-Self thanks brother, sounds like a new fridge to me and never LG because so far i seen only horror stories from them, they really don't respect customers at all
@mwilasiuluta7689
@mwilasiuluta7689 2 жыл бұрын
My chest freezer is tripping the breaker just when I switch it on. What could be the problem?
@Your-Self
@Your-Self 2 жыл бұрын
The breaker could be weak or overloaded with other appliances. If it's a GFCI outlet, try a regular outlet. The compressor could be shorted to ground. Did you check that?
@thumpertammy1
@thumpertammy1 2 жыл бұрын
great job, I have LG LFX28978ST /04, three of four days ago my freezer quit freezing but air was blowing from ever where where it suppose to blow and pretty cold too but evert thing in the freezer thawing out but refrigerator section was working fine until last night now both refrigerator and freezer not cooling has temperature about 51 all the fans working fine, compressor coming starting and shutting off as it suppose to do and one line in compressor is cold and one line is hot as its suppose to be, can you please help me and guide me how to fix it, i called this he knows some about refrigerators he said my compressor is gone better to buy a new refrigerator
@ray-d-ology1154
@ray-d-ology1154 Ай бұрын
What if my ohms just jump around when on the compressor pegs and won’t give a real reading
@Your-Self
@Your-Self Ай бұрын
Try to keep your leads as steady as possible. Check your multimeter wires. They could be damaged or not inserted all the way.
@juddsmith1
@juddsmith1 2 жыл бұрын
Hi thanks for the great videos! New subscriber here. I have an old-school compressor that won’t start. I changed out the start relay but still not working. My readings are across the three pins 5.4 3.2 8.2 my low readings don’t exactly match the total high rating. About .4 difference. is this enough to indicate a problem with the compressor? Thanks!
@Your-Self
@Your-Self 2 жыл бұрын
Your compressor readings seem to be OK. Did you check if the compressor is shorted to ground? If the fan (next to the compressor) is not running either, the thermostat (temperature sensor) could be bad.
@juddsmith1
@juddsmith1 2 жыл бұрын
@@Your-Self hello! Yes I checked continuity between Pinz and ground seems to be OK. Both fans are spinning OK. I thought I eliminated the thermostat because I checked for continuity across its connectors at room temp is that right? Thanks for your quick reply!
@Your-Self
@Your-Self 2 жыл бұрын
It's difficult to say because there are many different mechanical and computer-operated systems. So depends on your model number, problems may vary.
@joseelmarjuanico5181
@joseelmarjuanico5181 2 жыл бұрын
Sr watching your vedio. Regarding 3 types of compressor. Why that lg com. Deffirennt widing? Kindly explain . ? Your subcriver from the philippines thank you
@Your-Self
@Your-Self 2 жыл бұрын
The LINEAR technology is different than the others. So it requires only 2 terminals, HOT and Neutral. It can also be powered directly from the wall electrical outlet.
@heatncool
@heatncool 3 жыл бұрын
What if you have no continuity between 2 windings. No resistance. It was a new conpressor that came in.
@Your-Self
@Your-Self 3 жыл бұрын
If you are talking about an LG Linear compressor, it has just one winding. You should be able to measure a small resistance between 2 pins, but other sides should be open OL.
@Fromtheroad31
@Fromtheroad31 5 жыл бұрын
Thank you for the video. I have an LG Linear compressor that im testing. The ohms read 9.0. What would higher than 7.5 mean? Thanks in advance.
@Your-Self
@Your-Self 5 жыл бұрын
Every compressor is a little different, and the exact resistance range is written in the tech-sheets for your unit. But 9 ohms between two terminals is typically a good number within the specification.
@Fromtheroad31
@Fromtheroad31 5 жыл бұрын
@@Your-Self Thank you!
@Jagger02
@Jagger02 4 жыл бұрын
Thanks for asking this question. I was getting an 8.2 reading on an LG linear.
@sumtingwong8340
@sumtingwong8340 3 жыл бұрын
@@Jagger02 so if your compressor was still good what was the problem on your fridge? Currently trying to fix mine
@allanleversedge6187
@allanleversedge6187 2 жыл бұрын
Hi great tutorial,my second hand freezer doesn't chill to more than 4°C and the compressor is very hot running continuously and the orange warning light stays on. Its otherwise in very tidy condition as is less than a year old,it takes hours to even get slightly cold,any ideas please
@Your-Self
@Your-Self 2 жыл бұрын
Does it have a condenser fan near the compressor, and is it running to cool the compressor? Also, there could be a sealed system problem, for which you'll need a tech to look at.
@allanleversedge6187
@allanleversedge6187 2 жыл бұрын
@@Your-Self thankyou,no fan for cooling,very basic design will enquire with a tech,to check gas
@troymelville8706
@troymelville8706 3 ай бұрын
Great video! I have linear on LSFXC2476S, shows 9.5 between the bottom and back pins, nothing on other two, also not shorted out. Refrigerator and freezer get cold, but eventually warm up. Board shows 6 flashes. Any ideas? Thanks!
@Your-Self
@Your-Self 3 ай бұрын
The 6 flashes could mean a lot of things, but mostly a bad compressor. Even if it checks out good with a multimeter. If the compressor was just replaced, the problem could be with a restriction created during the installation. If it wasn't replaced yet, it's best to call LG directly. They may replace it for free (under a 5-year warranty) or give you a free compressor. You'll pay for the installation though.
@troymelville8706
@troymelville8706 3 ай бұрын
@@Your-Self what leads would I check to see if it is the board that's bad?
@Your-Self
@Your-Self 3 ай бұрын
If the compressor is running, the board is good. Usually, when the compressor is running but not cooling, means a bad compressor internally. Sometimes, however, there could be a refrigerant leak. In this case, a tech will need to attach gauges to check the internal pressures.
@troymelville8706
@troymelville8706 3 ай бұрын
@Your-Self thank you so much! I guess I will part it out. Not worth putting a compressor in it. I bought it for $100, I'm sure I can get out of parts
@AmitKumar-es6tw
@AmitKumar-es6tw 4 жыл бұрын
Thank you for the video. I followed the steps and found the reading as 8.6, OL, OL. I have LG model LFXS29766S /00. I checked voltage coming from main circuit board to thermistor assembly and found it fluctuating and it never reached up to 110v. does it mean main board is having issue? both freezer and fridge are not cooling. overload protector is having continuity. thermistor assembly output to compressor is also not reaching up to 110v. not sure if it is suppose to be 110v. what could be the issue here? Thank you
@Your-Self
@Your-Self 4 жыл бұрын
The compressor seems to be good electrically with 8.6 ohms. Does it actually run? The control board supplies the compressor with a variable 80-220 voltage. So if you are getting at least 80VAC the compressor should be running well. Do all the fans run? Did you see the video on how to run the Test Mode on LG? kzbin.info/www/bejne/bWHcZ2SJpsSBi5I
@angelfishhatchery9400
@angelfishhatchery9400 3 жыл бұрын
Great videos! I have an lg lfx28978st 10 years+ (just out of warranty) and a month ago it started to moan (it was running hot) so I cleaned out the back and it went back to normal. Last week it stopped holding temperature, 20 in the freezer ( Ice cream like whipped cream) and the fridge is about 40 (a bit warm) and runs almost continuously. I pulled it apart (freezer) all the fans run, coil in the freezer only frost in a couple places and I ran the tests/reset based on your other video it didn't really do anything and there are no LED flashes. No signs of R143a leak. I tried testing the ohms but I am not getting a decent reading. The buzzer only sounds on 1 connection, but if I turn to different scales I get something out of another and I'm not sure of the reading as the scales are messing me up. The 7.5 ohms is really 7.5K right? Based on what my Fridge is doing I assume it's dying, is that correct or is there something that would make it run all the time and not cool, like a clog which i would assume be coming from something in the compressor.
@Your-Self
@Your-Self 3 жыл бұрын
Your model has a Linear compressor, so the resistance should be a small 6-9 ohms (not "K ohms"). The fact that you got 10+ years out of this LG compressor, is a great deal! Your assumption is correct, the problem is with the Sealed System. Any component of the System repair will be expensive (~$600-$1000). So you need to decide if it's worth the repair.
@whatfreedom7
@whatfreedom7 2 жыл бұрын
@@Your-Self I looked at LG fridges yesterday and noticed where the door has water and ice still says linear but on the other side it says on a little badge “inverter linear”. Did they change the probable magic compressors or did it always say that? I did see where they have a software update to prevent their common line leaks due to corrosion from killing the compressor.
@muhdibrahim8817
@muhdibrahim8817 Жыл бұрын
Thank you sir. Mine is also an lg compressor and the test i carried was like thsi C+S=21 C+R = 17 S+R = 37 And i tested the relay and ptc in continuity mode, they are okey and the refrigerator compressor didnt start with all this test, pls any help
@Your-Self
@Your-Self Жыл бұрын
Did you check if the compressor is "shorted to ground" as in this video? If it's not shorted, it could be mechanically locked up... not sure. Is the compressor making any humming sounds like it's trying to start, and then clicking off? If there is no sound at all, the temperature sensor inside the freezer/fridge may be bad. So it's not asking the compressor to start.
@arkark1685
@arkark1685 Жыл бұрын
I have a Lg lmxs27626s recently stopped producing cold air, I feel the fan blowing in the freezer, and can feel it up top as well, the compressor sounds good, and the fan near the coils runs as well, I’ve done the test 1 and 2 from pcb, I also checked the fuse with a meter i do get 22 22 on the display but from one of your comments that doesn’t mean anything. I did notice some moisture near the bottom of fridge while access the compressor/coil not sure if that was leaked fluid or possible freezer items melting and leaked out. Any advice would be greatly appreciated as technicians are so expenses be to come out to diagnose
@Your-Self
@Your-Self Жыл бұрын
This model has LG linear compressor, which is the most common problem in the system. LG will typically replace the compressor for free if it's under 5 years old. However, this model also has 2 cooling evaporators. And the one in the fridge compartment, most of the time, has a refrigerant leak. Which may not be covered by LG. You have about a 50:50 chance of one of these issues. Unfortunately, it's impossible to figure out which one it is without a tech.
@bobjayp
@bobjayp 2 жыл бұрын
In the split phase type, are the absolute resistance values important or only the sum? I have read other places that the delta between Run and Start should be about .5 Ohms. If much more than that then there is likely a turn short. My compressor values are 4.6 6.7 and 11.3. So they add up but have a large difference.
@Your-Self
@Your-Self 2 жыл бұрын
As long as the Run and the Start values are different and add up together, the windings should be fine. If the condenser fan (next to the compressor) is running, but the compressor is not, the Start Relay could be bad. The compressor could also be mechanically locked inside... there is no test for that.
@ES4406
@ES4406 3 жыл бұрын
great video.... huge help.
@Your-Self
@Your-Self 3 жыл бұрын
Thanks for watching!
@diego_villena
@diego_villena 4 жыл бұрын
6.3, 6.3, 10.6 are my numbers. Freezer and fridge both cool but not cold, starter relay making a loud click as well. I'd initially thought it was the starter relay, as the overload reading was pretty high (3.4). But because the numbers are so off on the compressor, and the relay isn't really too rattly, I just don't know.
@Your-Self
@Your-Self 4 жыл бұрын
The numbers don't look good for a basic compressor, nor for BLDC. I'd verify the resistance once more. If the compressor starts and runs for a few minutes the start relay is good. If the compressor starts and runs for a few seconds, you may have a failed TSD starter instead of more popular PTC relay which may rattle when bad, and the compressor would not start at all.
@diego_villena
@diego_villena 4 жыл бұрын
@@Your-Self So, I think you're onto something. After the click, I feel like I do hear the compressor hum to life, but it doesn't seem like it sustains for long. This repeats every couple of minutes when the clicking comes back. Seems more and more like the compressor is bad. This may be entering into speculation territory, but we've had some bad electrical issues with our fuse box in the house recently. Lots of brown-outs and black-outs, sometimes several in a single day. While we recently got the box replaced, I noticed that the refrigerator issues started very soon after, perhaps even the same day as the box got changed out. Could the flickering power have possibly shot this compressor? It's pretty new, under two years old, and ran fine before the power issues. Have you ever heard of something like this? Thanks very much for the quick response. This channel is awesome-you have a new subscriber!
@Your-Self
@Your-Self 4 жыл бұрын
Flickering power is not good for any device, so it's possible that the compressor got damaged by it. If you are certain that the measured resistance is correct, the compressor is probably dead. Two windings on a basic compressor can not be the same. A Start winding should be larger than a Run winding, and a combination of those 2 values should be the largest number. Sorry for the bad news :(
@diego_villena
@diego_villena 4 жыл бұрын
@@Your-Self So, I've got some good news! After banging my head against this project all day, I decided to take a break and do some cleaning. Plugged the vacuum into the same outlet as the fridge, and when I turned it on it sounded like it was turbo charged. Then, it started giving off an electrical burning smell, so I promptly turned it off. Moved it to another outlet, vacuum ran fine. Got a hunch that using an extension cable to get the fridge hooked up to the good outlet might help out. Few hours later, and we've got ice cubes again! I reckon the compressor was pulling way too much off the outlet, and the overload had to keep kicking in to keep from things going all the way to pot. I also realized the compressor itself was getting very warm very fast, even after being left unplugged and cooled off for a few hours. So, I'm giving the electrician another call tomorrow. But for the time being, looks like we don't need a new fridge! Thanks for helping me trouble shoot, and educating me along the way.
@Your-Self
@Your-Self 4 жыл бұрын
Glad it worked-out better than expected!!!
@gaquesad
@gaquesad Жыл бұрын
Have an sumsung inverter compressor and it has all electrical readings fine also control boards seems to be working fine but it seems to be a mechanical compressor internal issue!!! How often is this?
@Your-Self
@Your-Self Жыл бұрын
BLDC compressors are very reliable, but of course, anything can happen. If your compressor is not shorted and has all 3 windings the same value, it's probably good. The inverter fails more often. If it gets 120 VAC on two larger wires, and a small DC voltage around ~2.5 V on two smaller wires, but the compressor is not running, the inverter is probably bad.
@jimdefilippis9630
@jimdefilippis9630 2 жыл бұрын
Nice video. I never heard of a linear compressor. Not knowing, if I was checking it and found 0.0 readings on 2 of the pins , I would think the winding's were shorted together. Is the compressor three phase or does it have a start and run winding. Thanks for the video
@Your-Self
@Your-Self 2 жыл бұрын
A cheap multimeter will show 0.0, but a more advanced meter will show OL. An LG linear compressor has just one run winding, unlike 3-phase or conventional start and run.
@jimdefilippis9630
@jimdefilippis9630 2 жыл бұрын
@@Your-Self nice to know/ never thought a compressor could run with just one winding.
@mateknezovic8170
@mateknezovic8170 2 жыл бұрын
I have blcd and ist same on three 14.2. Ist my kompresor fine?
@Your-Self
@Your-Self 2 жыл бұрын
Probably yes.
@williampenrose696
@williampenrose696 3 жыл бұрын
I have an old school compressor and it reads perfect at 9.3, 5.4 and 14.7. I have a new relay, and it vibrates but it doesn't cool the fridge, oy part I haven't replaced is the overload switch but I tested it and it test fine. I'm not sure what to do next from here.. Any suggestions?
@Your-Self
@Your-Self 3 жыл бұрын
If the compressor works (vibrates), the overload is good. Do the fans, by the compressor and inside the freezer, work? If they do, you may have a defrost problem (Evaporator is full of icy-frost), or a refrigerant leak (an expensive repair).
@peterodland3386
@peterodland3386 4 жыл бұрын
Great videos. LG LFC25760SB. Fridge will only cool to 45 degrees and freezer stays at around 30. Fans running in fridge and freezer. Compressor running. Compressor is hot to the touch. Multimeter is registering 4.4, 7.2 and 11.5 (top) on compressor. Ran through tests on PCB. All seems fine. Any advice?
@Your-Self
@Your-Self 4 жыл бұрын
You have a basic compressor, which is more reliable than LG linear! First, try to clean the condenser coil from dust and hair with a brush and vacuum. Also, move your fridge a couple of inches away from the wall for better air circulation and cooling of the compressor. If that doesn't help, the defrost system may be malfunctioning. Remove everything from the freezer, and unscrew the back-wall to look at the evaporator coil. If it's full of a thick layer of ice and snow, the problem is with the defrost. If there is just a little frost on the top or the bottom of the coil, the refrigerant gas is probably leaking out from the sealed system... that's the worst case of scenario :( If you have IR temperature gun, check the temperature of the condenser coil as on this video: kzbin.info/www/bejne/n6HagJion6t8isk
@peterodland3386
@peterodland3386 4 жыл бұрын
YourSelf thanks for the additional tips. I cleaned the condenser coil and the rest of the mechanical cabinet of dust, etc. and went through a full defrost of the fridge. I plugged it back in and the fridge cooled to 40, but the freezer didn’t get to a temp where ice packs would freeze. I then used the infrared thermometer gun to check the condenser coil temp. It showed around 19 degrees warmer than the air. Because this is a basic compressor, it should be closer to 30 degrees warmer, correct? Are we at replacement of the fridge?
@Your-Self
@Your-Self 4 жыл бұрын
I'd call a tech, and ask for a quote on suspected "low side leak." See how much, hypothetically, will cost you to replace an evaporator (with the leak), and refill the refrigerant. Maybe, it's worth it. Just keep in mind, that the technician may find some other problem, because it's easier to diagnose in person. Good luck!
@peterodland3386
@peterodland3386 4 жыл бұрын
YourSelf thank you!
@benphan6265
@benphan6265 3 ай бұрын
I have a LG fridge with Linear Compressor. Compressor tested and Ok I bought new starter relay so relay is OK Capacitor tested and OK All fans are working including Coiled fan. However, the compressor not start (not running) when I plugged in the power. Can you tell me what else can be wrong? Thanks
@Your-Self
@Your-Self 3 ай бұрын
LG linear compressors don't have a starter relay... you probably mean overload relay. The linear compressor is driven by the computer board (PCB). So, the board may be bad. Linear compressors can be started and run with a "cheater cord" straight from the wall outlet. But I won't recommend doing it for nonprofessionals.
@benphan6265
@benphan6265 3 ай бұрын
@@Your-Self thank you for your reply. I press the test button on the board and it gave me an error code 22. It means problem with compressor relay. I changed the compressor relay, but the compressor still not running.
@Your-Self
@Your-Self 3 ай бұрын
The number 22 is not an error code, at least in the USA market. It indicates Test-2. When you press the test button a third time, 33 should come up on most models. Other models just have two tests.
@benphan6265
@benphan6265 3 ай бұрын
@@Your-Self ah I see. thank you . I think I should call for professional services since everything is in order but the compressor not running.
@hassanyusuf7280
@hassanyusuf7280 Жыл бұрын
thank you
@Your-Self
@Your-Self Жыл бұрын
Thanks for watching!
@chaldeani6884
@chaldeani6884 4 жыл бұрын
Thank you for the video! My compressor is the BLDC I got a new inverter box installed today, plugged it in fridge and it worked! So I’m happy but then I went to check in 30 minutes later compressor was super super hot!!! Why is that??? Thanks for your help in advance!
@Your-Self
@Your-Self 4 жыл бұрын
The compressor is hot, but is it still cooling your fridge? Near the compressor should be a fan, is it running at the same time as the compressor?
@chaldeani6884
@chaldeani6884 4 жыл бұрын
Yes! The compressor is cooling and yes the Fan is working! but the compressor is super hot, it almost burned my hand!
@Your-Self
@Your-Self 4 жыл бұрын
The compressor could be hot because your fridge was really warm, and it takes a lot of power to cool it down initially. After that should be easier. The condenser coils next to the compressor could be covered in dust and hair, clean it as needed. The fan cooling the condenser and the compressor could be failing and working intermittently. The fridge could be jammed into the corner without any gaps for sufficient air-flow behind it. Make sure there are about 2" gaps on all sides of your fridge. Difficult to say exactly why, without being there to inspect it. Maybe it's normal operating temperature for your compressor, you just never noticed it before!?
@chaldeani6884
@chaldeani6884 4 жыл бұрын
I will put another Fan to help cooling it and thank you so much for all your help!
@vladimirbarbashov8389
@vladimirbarbashov8389 3 жыл бұрын
Hello I have LG with freezer at the bottom. Top fresh food section stopped cooling , air is blowing ( when I open the door and hold the switch I feel the air blowing but it is barely cold). The freezer is a bit colder but nowhere close to freezing temps. Compressor sound like working and it is intensively warm , however both tubes : in and out tubes- are at the same room temperature and the coil is not even warm. The coil is somewhat dusty but nothing major and the fan is blowing air through the coil. Does it mean compressor is Done?! Appreciate any help, thanks
@Your-Self
@Your-Self 3 жыл бұрын
The problem could be with the refrigerant leak. But if it's an LG Linear compressor, most likely it's damaged inside. If your refrigerator is under 5 years old, it's worth calling LG directly, and they may fix it for free.
@witherdragon22
@witherdragon22 4 жыл бұрын
Thanks for the video! I followed the video to test my LG linear compressor (FLB075LANA). The reading is 9.5, O.L and O.L (not measurable). Does it mean the compressor is bad? The compressor is running but not cooling at all. Thanks a lot!
@Your-Self
@Your-Self 4 жыл бұрын
The resistance reading of your compressor is good, but it probably failed mechanically. The internal suction valve is very weak on these compressors, so it's just idling and not compressing. If you have a purchase receipt and your fridge is under 5 years-old, LG will fix it absolutely free. After 5 years you'll have to pay labor fee about $400
@witherdragon22
@witherdragon22 4 жыл бұрын
@@Your-Self Thanks for the quick reply! I will contact LG.
@AmitKumar-es6tw
@AmitKumar-es6tw 4 жыл бұрын
@@witherdragon22 Hello, Were you able to have your compressor fixed by LG? Were you seeing error code 22? I have same compressor and not cooling at all. resistance readings are 8.3, OL and OL.
@witherdragon22
@witherdragon22 4 жыл бұрын
A Kumar I didn’t check for any error code. LG came and replaced the compressor covered by warranty, it is fixed now.
@hassanyusuf7280
@hassanyusuf7280 Жыл бұрын
thank you again
@robbrown6495
@robbrown6495 2 жыл бұрын
I checked out your video because I am trying to diagnose a display case chiller that we have that won't cool. It appears that the compressor is running but it is very quiet. Capacitor checks out OK, and the relay and cut-out both appear fine. Checking the pins on the compressor I'm getting what appear to be high but logical readings of 15 , 30 and 45 ohms. I'm basically trying to check as much as I can before calling someone to come and re-gas the system and check for leaks. Are the readings too high?
@Your-Self
@Your-Self 2 жыл бұрын
The readings are on a higher side, but just fine. If there are fans in your chiller, make sure they are running. Otherwise, it's time to call a technician to investigate.
@robbrown6495
@robbrown6495 2 жыл бұрын
@@Your-Self I have just one fan inside the chiller, next to the thermostat control, and that's working fine. It's a Fujidenzo chiller and every video online appears to be about finding leaks and re-gassing. So don't see any reason why mine should be any different. Thanks for your answer.
@josebolivar329
@josebolivar329 4 жыл бұрын
hi working on LG refrigerator (all motors work LG liner compresor good resident but is not cooling.. thanks
@josepacheco5244
@josepacheco5244 Жыл бұрын
Hi! My lg linear compressor passed all the tests. But, my reading on the only pins that read are averaging 19. What does that mean? Thanks!
@Your-Self
@Your-Self Жыл бұрын
You may have a loose wire on the multimeter if the reading is not stable and is jumping too much. What is the actual problem? The compressor is not running at all or running, but not cooling the refrigerator?
@josepacheco5244
@josepacheco5244 Жыл бұрын
@@Your-Self the compressor sounds to be running. Gets warm. But no cool air in freezer, no air flow In fridge
@Your-Self
@Your-Self Жыл бұрын
If you can feel the airflow in the freezer, but it's not cold, there are two possible problems. Either the refrigerant gas has leaked out. Or, most likely, the internal reed valve cracked... typical for a Linear compressor. If the fridge is under 5 years old, LG usually replaces the compressor absolutely free.
@carlosg6730
@carlosg6730 4 жыл бұрын
So would fridge I should buy? The lg with their inverter compressor or the whirlpool with their new xpert system? My family have to buy one but we are afraid about the lg almost we want one because they see that have a good cold system and the food keeps better for most time
@Your-Self
@Your-Self 4 жыл бұрын
Every refrigerator brand has its problems, so buy the one you like withing your budget.
@carlosg6730
@carlosg6730 4 жыл бұрын
thanks!
@lengpengloh3696
@lengpengloh3696 4 жыл бұрын
My GoldStar compressore wen measuring.. Have resistant with 18.2ohm, 44.8ohm and 58ohm. Is that consider compressor still funtion? When i switch on the, the compressor no running but get warm.
@Your-Self
@Your-Self 4 жыл бұрын
The resistance looks too high, but could be due to inaccurate multimeter. Does the compressor make a humming sound when it tries to start, and then do you hear a CLICK about every 20 seconds?
@cindys4288
@cindys4288 2 жыл бұрын
@YourSelf . I have an LG Refrigerator Model No: LFXC247226/02. It has stopped cooling. I was told by a technician PCB and compressor needed to change. I bought new PCB Model: EBR78940615 and LG Compressor - FLB075LANA. Hooked by both parts, added refrigerant and what not. The fridge powered on but still will not cool. It remains hot. What do you think maybe the problem here?
@Your-Self
@Your-Self 2 жыл бұрын
Your refrigerator model seems not to be valid. If you install the new "Universal" compressor FLS075LANA, you'll need to update the original PCB or buy a new PCB and update the software with a special LG jig as well. Since you installed the old version compressor FLB075LANA, you should be able to use the old PCB. The LG Linear compressors are very slow on cooling, so it may take a whole day to feel the difference. Also, they are very sensitive to the amount of refrigerant you put in. The amount has to be exactly as on the sticker.
@WildCogs
@WildCogs 3 жыл бұрын
Great video, pretty sure I have an old school, resistance I'm getting is 52.9 - 52.3 - 105 so works out, but considerably higher, is this still okay, I change the relay (but it looks like I was sent a faulty one)
@Your-Self
@Your-Self 3 жыл бұрын
If your multimeter works well, the resistance is kinda high, but not unheard of. It just means that this compressor uses about twice as much electricity to run. What exactly is the problem... the compressor doesn't start at all?
@christofer99999
@christofer99999 2 жыл бұрын
@@Your-Self the compressor is working but the refrigerator is not very cold. It reaches maximum - 5°C. In your video you say the measurements on linear compressor is different than those i found. The measurements i found are similar to old school compressor so i think this is the problem. I need to find solutions to inform the technician because at he's last visit 3 months ago he said it's leaking fluid but i don't trust him because the refrigerator is at the same condition. If it's leaking it should be empty until now correct?
@singsong2992
@singsong2992 2 жыл бұрын
I checked the resistance by putting one lead on the pins and the other one on the copper pipe but the numbers didn't jump around. But when I checked the resistance between the pins the numbers do jump around. Does that mean the compressor is bad?
@Your-Self
@Your-Self 2 жыл бұрын
The numbers could be jumping due to friction, or the multimeter could be bad. Try holding meter leads on the pins steady.
@singsong2992
@singsong2992 2 жыл бұрын
@@Your-Self You're right. It was due to friction. The numbers stabilized and the compressor seems to be good. Thanks
@caseyvess41
@caseyvess41 3 жыл бұрын
So, if I have a BLDC compressor and it is 0.0 on all pins, it is Dead and needs to be replaced?
@Your-Self
@Your-Self 3 жыл бұрын
Are you sure your multimeter is working correctly?
@caseyvess41
@caseyvess41 3 жыл бұрын
@@Your-Self black in common, red NOT on the Voltage side. I did just recheck the multimeter on a household electric receptacle and it registered 123.3 ( I have a 110 outlet) Are you saying it should register some kind of number?
@caseyvess41
@caseyvess41 3 жыл бұрын
I'm going to check one more time. It is possible I had the dial on 200k instead of 200
@georgeelmerdenbrough6906
@georgeelmerdenbrough6906 4 жыл бұрын
My numbers did not jump until I checked them against each other ....so its shot right ?
@georgeelmerdenbrough6906
@georgeelmerdenbrough6906 4 жыл бұрын
Also the first test where you put both leads on the copper tubing got nothing ...so I am not sure if my cheap meter is just not cooperating
@brianorlando6423
@brianorlando6423 4 жыл бұрын
I have an lg linear compressor and according to your test it's good. Relay is good. I want o check for feon leaks with soap and water. I already checked behind the access panel in the bottom rear and did find anything. Should I check the coils behinf the back wall also and if so dies the refrigerator have power while checking? I was going to power down ofcourse while accessing and was wondering if I should power it back on to testcwith sosp and water. Thank you in advance as I'm pulling my hair out after checking everything I can think of.
@Your-Self
@Your-Self 4 жыл бұрын
The Sealed System is always under pressure, so the refrigerator can be unplugged to check for Freon leak. If the compressor is running, but not cooling, most likely it's worn-out mechanically inside. How old is your fridge? It could be under LG 5, or 10-year warranty.
@brianorlando6423
@brianorlando6423 4 жыл бұрын
@@Your-Self I'm trying to start a little hobby/startup business of buying used faulty refrigerators and trying to fix them and sell for a profit. I bought it for $73 and rolled the dice it wasn't going to be the compressor. I felt like a took a class in refrigerator repair with everything I learned. I like tinkering with things but this has me beyond frustrated. So long story short its 7 years old I believe but I can't use the warranty. Thank you for the response, maybe take the rear wall of the inside and check those coils for a leak. One more question please. I've heard you can transport them on it's side for short periods of time if you allow the same period of time after you unload and stand it up before you plug it in. Any truth in that?
@Your-Self
@Your-Self 4 жыл бұрын
To figure out whether it's a leak or an inefficient compressor, you need to check the pressure inside the Sealed System... low pressure indicates a leak. If transporting the refrigerator laying down, the oil from the compressor will flow into the pipes where it's not supposed to be. Giving "enough" time the oil should drain back into the compressor.
@ambidex
@ambidex 2 жыл бұрын
Excellent video but I'm still a little unsure on my testing. I have an Old School compressor that seems to not be coming on. I've replaced the capacitor and start relay with no luck. The ohm readings are 5.4, 4.3, and 8.8. Based on your video the full length of windings should add up to about 9.7 but I'm a full ohm lower. None of the pins go to ground (using the copper wiring as ground). Does this indicate it's bad? I'm perplexed on what to try next. Thanks
@Your-Self
@Your-Self 2 жыл бұрын
Your ohm readings are close enough, so electrically, the compressor is probably good. If the fan next to the compressor is running, the temperature sensor is good as well. It's possible, that the compressor is mechanically locked inside. Sometimes, a 3 in 1 hard start device can unlock the compressor. But there is no guarantee how long it will work. It could last one day or years.
@ambidex
@ambidex 2 жыл бұрын
@@Your-Self I see. I don't have a 3 in 1 hard start device to test with. Is that difficult to do?
@Your-Self
@Your-Self 2 жыл бұрын
It's a mediocre difficulty, and you'll have to cut and splice the wires. Just search KZbin for "3 in 1 installation" to get an idea.
@ambidex
@ambidex 2 жыл бұрын
@@Your-Self thanks. I'm familiar enough with electrical work to try. For whatever it's worth I get zero sounds from the compressor when plugging in the fridge and waiting. Both capacitors and start relays I've used pass multimeter tests. If a hard start was needed would I hear any sound before hand? If the hard start works do I just leave it in place or go back to the old relay if it "un-sticks it"?
@jigabchannel5577
@jigabchannel5577 5 жыл бұрын
How about, may refrigerator the copresor running but not cooling?
@Your-Self
@Your-Self 5 жыл бұрын
Is your refrigerator made by LG... what is the model number?
@tori22turner
@tori22turner 4 жыл бұрын
My LG FRIDGE stopped freezing all the items in the freezer the fan seems to work ..also takes forever making Ice as well. Do you think this is an easy fix? Gonna have to throw away a bunch of food soon :( can't seem to find a freezer switch either
@Your-Self
@Your-Self 4 жыл бұрын
There is no easy answer to this question. Maybe need to clean condenser coils from dust, or it could be a beginning of a major Sealed System problem. Try to run a system Test first as on the linked video, and go from there... kzbin.info/www/bejne/bWHcZ2SJpsSBi5I
@sanjeevsethi7704
@sanjeevsethi7704 4 жыл бұрын
Hello Yourself I just watched your video. Very well explained. Thank you. I have a Samsung fridge (rfg297aawp from 2009). A few days ago, the power went out. When the power came back on, the neither the fridge nor the freezer cools anymore. The condenser fan and evaporator fans are running (twin cooling), but the compressor is not. BTW: it is a BLDC 3-phase compressor.To the touch, the compressor feels humming but no noise. Compressor doesn't get hot either and none of the lines are hot either. Using the multimeter, the ohm reading among all three terminals is 10.0 - as it is supposed to be per the spec sheet. There are no fault codes on the fridge. what do you think could be wrong? Is the compressor shot? Any suggestions will be greatly appreciated.
@Your-Self
@Your-Self 4 жыл бұрын
When the power came back may be the Inverter PCB got damaged. Did you check the inverter (the smaller board above the main PCB)? There should be an LED light on it... is it ON, Flashing, or OFF? There is also a fuse on the inverter, if the LED is dead, may be the fuse is busted.
@sanjeevsethi7704
@sanjeevsethi7704 4 жыл бұрын
@@Your-Self Thank you, Yourself for a very prompt and quick reply. I checked the inverter PCB and the light is solid. I am suspecting the main PCB based on the troubleshooting guide I came across online (applianceassistant.com/ServiceManuals/RFG297AA-Fast-track-R22.pdf). Step 2 in the guideline on page 6 says to check for dc voltage on a specific pin on the main board. I get a reading of 0 on the pin. The board is about $200. I am hesitant to invest the money if the problem is actually with the compressor - and this is just a symptom. Is there a way to check if the compressor is mechanically in a functional shape. Electrically, it looks good based on the ohm readings. I appreciate you taking the time to answer the queries. Great contribution.
@Your-Self
@Your-Self 4 жыл бұрын
Samsung instructions are not very clear... once they say to check CN75 between pins 3 and 4 for 2~2.8vdc during the Forced Test Mode... but the second time they say to check CN75 pin 4 and CN76 pin 1 for 2~2.8vdc. Also, you need to check CN75 pin 2 and CN76 pin 1 for 5vdc... If you are not getting any voltage there (but your multimeter works correctly) it means that the main PCB is not sending the signal to the inverter to run the compressor. Unfortunately, this type of compressor can only be tested electrically, and you already have done it. So the next step would be to replace the main PCB and hope that the compressor has not failed mechanically.
@sanjeevsethi7704
@sanjeevsethi7704 4 жыл бұрын
@@Your-Self Thank you again, Yourself. Very helpful, indeed. You are correct. The instructions are confusing. But, I do see 5vdc on CN75 pin 2. But no voltage on pin 4. I have gone ahead and ordered the main PCB. It will take a few days to get to me. Will post again what I discover after changing the board.
@cremist2317
@cremist2317 4 жыл бұрын
Hello. I have the same similar problems like the rest. I have an error code on my LG fridge. Flashing 3 times. I changed the board and I didn't work. Code says the compressor is not grounded. Its time to replace right?
@Your-Self
@Your-Self 4 жыл бұрын
Was the error code blinking 3 times before you replaced the board? If it wasn't, one of the wire connectors could be loose... just unplug and re-plug all of them. Did you check if your compressor is grounded (shorted to ground) as on this video? Is the compressor running, but not cooling, or not running at all? Are all the fans running? You can check them through the Test Mode like on this video: kzbin.info/www/bejne/bWHcZ2SJpsSBi5I
Inverter Refrigerator Dc Compressor UVW Testing In 3 Steps
6:03
Forever Tech English
Рет қаралды 437 М.
Meet the one boy from the Ronaldo edit in India
00:30
Younes Zarou
Рет қаралды 17 МЛН
Magic? 😨
00:14
Andrey Grechka
Рет қаралды 16 МЛН
Алексей Щербаков разнес ВДВшников
00:47
🩷🩵VS👿
00:38
ISSEI / いっせい
Рет қаралды 23 МЛН
LG refrigerator test and reset button
4:27
YourSelf
Рет қаралды 1,4 МЛН
#TECHTALK Check this before changing LG compressor
7:18
TMM Appliance Network
Рет қаралды 52 М.
How to check a compressor.
6:52
paulohvac
Рет қаралды 58 М.
How to test refrigerator compressor start relays
4:30
Parts Dr
Рет қаралды 463 М.
LG Fridge Not Cooling - Compressor Replacement
15:11
ShareTheRepair
Рет қаралды 78 М.
Cutting open a failed LG refrigerator compressor
13:41
Joe's Garage
Рет қаралды 243 М.
Identifying parts on a Refrigerator control board
12:01
TMM Appliance Network
Рет қаралды 25 М.
Meet the one boy from the Ronaldo edit in India
00:30
Younes Zarou
Рет қаралды 17 МЛН