THE BREAKER IS TRIPPING - Failed TRANE Compressor Diagnosis

  Рет қаралды 1,776

Surf Bros HVAC

Surf Bros HVAC

Күн бұрын

Here I diagnose a compressor that has failed and is tripping the breaker. Pretty much as simple as that. Easy diagnosis.
00:00 Arriving to Call
01:12 Diagnosing the Compressor as the Issue
09:00 Taking a Look at the Indoor Unit
10:10 Thoughts Afterward
#hvac #hvaccontractor #heatpump #hvacservice #compressor #trane

Пікірлер: 27
@hectorcastillo2901
@hectorcastillo2901 2 ай бұрын
Yes. I’d like to see live content. Gives a real feel to what we can see on a service call.
@28512ful
@28512ful 2 ай бұрын
Live service calls sound fun
@chesstime356
@chesstime356 2 ай бұрын
Yes let see the live service technician working
@chesstime356
@chesstime356 2 ай бұрын
Nice video man just subscribed your channel now
@Multianonymous73
@Multianonymous73 2 ай бұрын
First thing you do is ohm from compressor terminals to process piping when you find breakers tripping
@TetrahedralMolecule
@TetrahedralMolecule 3 ай бұрын
taking the hvac trap to youtube. legendary.
@yrs94
@yrs94 3 ай бұрын
I love your videos, keep it up!
@huasohvac
@huasohvac 3 ай бұрын
Good video. I know you can get a copeland equivalent of those compressors. May be a little cheaper and more readily available.
@SurfBrosHVAC
@SurfBrosHVAC 3 ай бұрын
Yeah we’re gonna see what’s what on Monday
@chesstime356
@chesstime356 2 ай бұрын
I which your videos
@28512ful
@28512ful 2 ай бұрын
I believe the official terminology for compressors you can't work on are hermetic. But you probably already knew that.
@Richard-zz2cb
@Richard-zz2cb 3 ай бұрын
Whenever I come to a call and the breaker is tripped, I don’t turn the power on immediately, the first thing I test is if the compressor is shorted to ground. What could happen if you turn the breaker on to a shorted to ground compressor, the terminals could overheat and shoot out and it’s not fun hearing or watching that, sounds like you’re standing next to a firework. Also trane commercial units don’t come pre charged with refrigerant, only pre charged with nitrogen, I asked tech support once why there was no king valve or no factory pre charge and they told me techs in the field were pumping systems down fully causing the coils to explode which explains why there is no factory charge. The person who did the startup should have wrote it down inside the panel of the unit, which they didn’t and I hate when people do that
@AaronPowellvox
@AaronPowellvox 3 ай бұрын
Trane units don’t have king valves. They have service valves but not king valves. Also, not all Trane commercial units come with nitrogen. A lot of them come precharged like normal.
@SurfBrosHVAC
@SurfBrosHVAC 3 ай бұрын
I knew someone would pull through with this info. I’ve installed big Trane systems but only package units. Thanks for the help
@Richard-zz2cb
@Richard-zz2cb 3 ай бұрын
@@AaronPowellvox oh I meant service valve, what is weird is all of the commercial units only come with nitrogen in them when we get Trane, except for the commercial package units
@Richard-zz2cb
@Richard-zz2cb 3 ай бұрын
@@SurfBrosHVAC yessir, no problem!!
@AaronPowellvox
@AaronPowellvox 3 ай бұрын
@@Richard-zz2cbmaybe that’s a state by state thing. Other than back in the day when they were phasing out R22 all our units come pre charged.
@AaronPowellvox
@AaronPowellvox 3 ай бұрын
So, there isn’t a 10 year warranty on that compressor?
@SurfBrosHVAC
@SurfBrosHVAC 3 ай бұрын
I googled it and it says 1 year parts 5 year compressor on Trane commercial. I told the customer I would confirm that with the Trane warehouse on Monday
@AaronPowellvox
@AaronPowellvox 3 ай бұрын
Yeah. I hate the way commercial warranties are. It’s alway less.
@allanbrito13
@allanbrito13 2 ай бұрын
​@@AaronPowellvoxi always thought it was because the units always run more in commercial
@AaronPowellvox
@AaronPowellvox 2 ай бұрын
@@allanbrito13 that’s probably so. I put a little over 30 tons worth of Trane units in a bagel shop where the outdoor units were 5 stories up on the roof and Trane said that they would not warrant them at all because of the insane amount of lift. Also, people are just rough on commercial stuff because it usually isn’t theirs. They don’t maintain them as much either.
@ktmrider707
@ktmrider707 2 ай бұрын
Live service calls would be cool to watch!
@joshh5912
@joshh5912 3 ай бұрын
Xfmr is tapped wrong…not that, that’s the problem.
@SurfBrosHVAC
@SurfBrosHVAC 3 ай бұрын
Yes I saw that too
WHY IS THE COMPRESSOR STEAMING??
18:29
HVACR VIDEOS
Рет қаралды 67 М.
MOM TURNED THE NOODLES PINK😱
00:31
JULI_PROETO
Рет қаралды 24 МЛН
AC Keeps Tripping Breaker and The 10 Most Common Reasons Why
12:45
Word of Advice TV
Рет қаралды 514 М.
Rectorseal PRO-Fit Quick Connect
2:06
Tradezone - Online Electrical Wholesaler
Рет қаралды 1,3 М.
Why I Avoid Working With Other Contractors LIKE THE PLAGUE
8:34
Surf Bros HVAC
Рет қаралды 1,3 М.
Diagnosing a Locked Compressor 3D
10:02
HVAC School
Рет қаралды 36 М.
Recalled Furnace?? Replacing It With a Heat Pump
9:40
Surf Bros HVAC
Рет қаралды 476
Trane Rotolock Compressor
5:08
David Jones
Рет қаралды 27 М.
Why Is My AC So Loud? How to Quiet a Noisy AC
11:10
Fox Family Heating and Air Conditioning
Рет қаралды 231 М.
How Air and Water Cooled Chillers Work
13:14
MEP Academy
Рет қаралды 73 М.
How to Check HVAC AC Compressor
11:51
Word of Advice TV
Рет қаралды 408 М.