Great to see you covering commercial/industrial electrical work. Potential entrants to the industry need to see the exciting side, it's not just second fixing sockets and testing and dealing with dodgy DIY homeowners. Sorry to say that socks and shorts are out on industrial sites which would probably harm your image!
@thedroneguy202410 ай бұрын
Glad to see regular videos, missed the content. :)
@nigelsmith795510 ай бұрын
Just want to know if the panel height is going to bug you all night! And you finally; after getting no sleep, knowing you haven’t wired or cored the wall, crack and drop the panel 2”! 😆 Pair socks from the US if I’m wrong! 😑
@Cjrelectrical10 ай бұрын
You were wrong we left it and I slept great 👍
@DC-oc6qd10 ай бұрын
Chris loving the content as usual.. would you and James to a tool loadout master vs apprentice 😅 you seem to have alot of new gear. cheers lads keep up the good work 👏
@ukbullylife796810 ай бұрын
Speed bits in an impactor blunts the holesaw ? Eaton do the slotted packs for 3 phase boards which saves you needing to cut pax
@cfprecious15 ай бұрын
Are there more videos to see the completed job ?
@AGU-9510 ай бұрын
Whats the advantages of using paxolin over grommet strip? Obviously it creates a gap between DB and trunking, so that trunking lid can be fitted but is there any other reason why you would use paxolin compared to grommet strip? Thanks.
@SparkcatcherFox10 ай бұрын
It can be difficult to get grommet strip over the cut edges of both the trunking and the DB. If you use Paxolin and cut it slightly smaller than the slot in the trunking and DB you can be assured the cables will rub only on the Paxolin and not the metal edges.
@SPARKY400T10 ай бұрын
Should be a nice job when finished Out of interest do the NHS require a particular board manufacturer in their estate or can you fit any thing?
@johnbrown-so3vz10 ай бұрын
Whoever has been called out for' no heating' because the client turned the dial fully clock wise when it should have been fully anti clock wise. His wife knew
@ConchurMccool10 ай бұрын
We all know the wholesaw is impacted rated but when you say to the apprentice go gentle I would always use a combi on a low speed but my apprentice hasn’t a clue what gentle means 😂
@chrisrussell842310 ай бұрын
You could always put another light at the other end aswell as it's quite dark there but great content though guys
@Cjrelectrical10 ай бұрын
Not my job 😁
@mxslick5010 ай бұрын
Not boring at all, James showed his sexy legs, lol. Seriously though, That was a good install in a very odd space. The paxlin(?) is something we don't seem to have here in the US, and our distribution boards (Panels over here) aren't as clean and well insulated as yours. There is a new line of boards by Leviton that are "Smart Boards", different from our normal, but they are a lot more money (abut 3-4 times more) than the standard (SqD, GE, Eaton) brands here. Look forward to the continuation of this job...and I feel for you having to do that coring. I've done a lot of it, and at one job in a vault under energized 480/277 4,000amp switchgear. With two inches of water on the bottom.
@tonywatson141210 ай бұрын
Yip...the swarf 🤔
@brianhewitt861810 ай бұрын
you should that board now while you got the chance
@Richardincancale10 ай бұрын
Yep lower the board!
@SNSNAKE10 ай бұрын
Just get them to move the pipe, I'm sure they won't mind "not my job".
@MartinE6310 ай бұрын
Sooner or later someone will curse you for fitting the board in that position!
@Mike_510 ай бұрын
3 Phase is fun until you have a Customer who doesn't want their supply disrupting for install work
@Andy-i5g8 ай бұрын
Gonna have to lower the DB, shouldn't have been left like that
@hbarnes248910 ай бұрын
Oof. That board looks a night mare to connect earth and neutral opposition sides of the board. Better you than me if I was given it to fit I'd return it to the wholesalers.
@Cjrelectrical10 ай бұрын
Your right one of the reasons I’m glanding into the trunking for ease of routing
@tangoengineering10 ай бұрын
Not the best job I've seen you do Paxolin wrong size and door not opening both schoolboy errors