Can Capacitor reduce our electricity bill ? Power saver device Real or fake

  Рет қаралды 1,379,799

The Electrical Guy

The Electrical Guy

Жыл бұрын

Can Capacitor reduce our electricity bill ? | Capacitor Connection in our Home
In this video, I have explained about what will happen if we connect a capacitor with the main power supply ? Can electricity bill reduce by connecting power factor capacitor with power supply ?
Thank You
Arun Gupta
Electricaltechnician02@gmail.com
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Hindi Channel @Electrical Technician
/ electricaltechnician
2nd Channel @electrical Wiring School
/ electricalwiringschool
Short Video @electrical technician Shorts
/ @electricaltechnician02
TELEGRAM :
telegram.dog/ElectricalTechnic...
FACEBOOK : @electricaltechnical
/ electricaltechnical
INSTAGRAM : @electricaltechnician02
/ electricaltechnician02
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
My gadgets for KZbin 📺
Camera 📸 For video Recording
amzn.to/3z3W9XM
Mic 🎤 For Sound Recording
amzn.to/3kpUyaK
Tripod Stand
amzn.to/3BajZmn
Overhead Stand For Recording
amzn.to/3z1rzhm
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Electrical Device For your Home which you Should Have
Wi-Fi Control Smart Plug top
amzn.to/3dAZrJA
amzn.to/3hcO6Sr
Multimeter for electrician
best - amzn.to/3w7Vbry
Low Price - amzn.to/3wfF1MC
Water Level Controller
Single Tank - amzn.to/3xdcrwY
Double Tank - amzn.to/2UnvJAX
Motor Starter
2 HP Motor Starter - amzn.to/366AlhL
2 HP Motor Starter - amzn.to/3xhVtxw
Toolkit For Electrician
amzn.to/3AmK1T5
══════⊹⊱≼≽⊰⊹═════════⊹⊱≼≽⊰⊹══════
Related Video which you Must watch
Frequency Meter Connection
• How To Wire Frequency ...
One Bulb ON OFF from 3 Places
• How to Turn ON & OFF O...
Type of MCB
• B C D K Z Type of MCB ...
Protection Device for Home
• Difference between MCB...
#home #electricitybill #electrical #capacitor ‪@ElectricalTechnician‬
‪@ElectricalWiringSchool‬

Пікірлер: 655
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Please watch the video carefully and completely before saying that this video is fake, or I am doing misleading. I made a dedicated video for you on how you can select the capacitor size to correct the power factor 👇👇 kzbin.info/www/bejne/Z5SxlpyXbqlofM0
@agnelodsa788
@agnelodsa788 Жыл бұрын
Fake news, are you an electrical engineer?
@teluguelectrotechbysivakum2283
@teluguelectrotechbysivakum2283 Жыл бұрын
False video don't believe. Power bill won't effect by using capacitor. Please share only truth.
@baneesh29
@baneesh29 Жыл бұрын
Then what is power factor?
@pramodtpn826
@pramodtpn826 Жыл бұрын
Capacitor value??
@robertikpeamah3042
@robertikpeamah3042 Жыл бұрын
What is the value of the right capacitor?
@fixingstuff8117
@fixingstuff8117 Жыл бұрын
Remember that each device should be power factor corrected with its own capacitor. Because things are switched on and off in a home. Your refrigirator, tv, bulbs, etc. either switch on and off by themselves or you switch them on and off. Connecting just one big cap into your supply, the cap will draw current when you switch off most of your inductive loads and then waste electricity for you, and save for the municipality.
@eddcua5481
@eddcua5481 Жыл бұрын
Quite true.
@teluguelectrotechbysivakum2283
@teluguelectrotechbysivakum2283 Жыл бұрын
False video
@janolivier5879
@janolivier5879 Жыл бұрын
@@teluguelectrotechbysivakum2283 Maybe not 100% accurate video, but it is very true. Google power factor correction to see for yourself. Most electric equipment with motor has capacitor inside to improve power factor(PF). Drills, blenders, etc. Lawnmower has cap next to motor, called starting cap, but I think it also does PF correction. On big motors you get starting and running caps, the running cap is for PF correction.
@priyabratroy6573
@priyabratroy6573 10 ай бұрын
Well explained! This should help break the MYTH most video watchers believe to be true. 🙏
@madanmohanmishra5421
@madanmohanmishra5421 10 ай бұрын
Capacity of capacitor ?
@TexasCanuck
@TexasCanuck 10 ай бұрын
I am skeptical about this. I am an Electrical Engineer and understand what a capacitor will do in the US. Most modern large load/motor devices already have a Start Capacitor that takes up the initial load surge. Unlike motor loads (HVAC, Well Pump, etc.), most electronic devices have such a slight surge that this won't be worth it. IMO, upgrading old non-LED lighting, fixing insulation, updating windows, and putting timers (WIFI/automated) on some items will save you a lot more money.
@timothydevries383
@timothydevries383 8 ай бұрын
You didn't watch the whole video...
@voytek3999
@voytek3999 7 ай бұрын
ONLY TRUE IF YOUR AC (Motors!) Is Unbalanced!!! (Power factor...)😮😮😢😅😊❤
@doyourbest7655
@doyourbest7655 2 ай бұрын
Adding capacitors to individual motors helps balance the other loads in a plant that has various inductive loads. This better power in the manufacturing plant with single phase and three phase motors/uses. Does not help your electrical bill. That’s why you don’t see it used voluntarily. If you are a big enough inductive load user the power company might give you a discount for installing capicators so they don’t have to on their side of the meter.
@flagmichael
@flagmichael 2 ай бұрын
@@doyourbest7655 (Retired from a Fortune 100 electric company.) The electricity provider does not care much about power factor in individual residences. Large subdivisions can warrant a capacitor ("cap") bank. Extremely High Voltage substations often have capacitor banks the size of a large shed on insulator stilts.
@bmainginyabuto4517
@bmainginyabuto4517 2 ай бұрын
How does updating Windows help reduce power consumption
@milind9098
@milind9098 Жыл бұрын
Very nice illustration... Which gives clear idias about voltage, current and power factor..kwh or unit. This video is creating intrest to know more and more electricity. Mohan.(India)
@robgad2271
@robgad2271 Жыл бұрын
Many homes who already use large motors for devices or air conditioning already have some of these in use in the house active circuit. Imagining an AC Capacitor as an energy saver defies the logic and centuries of use of these devices, if anything they are can be a drag on the system and waste electricity needlessly. But what do I know, I'm only an electrical engineer and educator.
@brettmoore3194
@brettmoore3194 Жыл бұрын
If you dont know about phase angle, plus optimizing voltage and current during the same phase angle then you dont know what your talking about
@priestmugivhela5789
@priestmugivhela5789 11 ай бұрын
Go back to that university and ask for your school fees, phase angle is at play... though we are not saving much , but we r saving...
@brettmoore3194
@brettmoore3194 11 ай бұрын
You say your a electrical teacher, have you heard about motionless electromagnetic generation... There is almost 33 different concepts based on the same fundamental idea of extracting energy from a magnet
@rxsyete
@rxsyete 10 ай бұрын
Does NOT save money for the consumer like us ONLY for the power supplier. So yes, will NOT lower our power bills. The engr. and teacher is correct.
@madgaming6810
@madgaming6810 10 ай бұрын
Ok so why The susbstations are usingg capacitor banks? Maximum homes are using capacitors ok.
@rev.jonathanwint6038
@rev.jonathanwint6038 7 ай бұрын
Depends on the area. I use a UPS and it scans the spikes. Got it bc of the ruined Electronics. My power was spiking 200 and was down to 90.. not a steady 120. So I am paying for the 200 but using only 120 . A Capacitor acting as a Reservoir. So I get a steady 120. PROTECTING MY DEVICES .The UPS also is a back up to let my pc shut down in a full blackout. BUT it saves electricity from those 200 spikes thar hit ever 10 seconds and last about 3 seconds. So I am not waistng the surges but saving then for the dims. That hit every 30 seconds and last about 2 seconds and ether surg or dim can ruin equipment. But I noticed my entire electricity bill went down since using the unit and found out it was cleaning the power to a lesser degree for the entire house not just my labtop unlike a regular surg protector that only stops surges not cleans them with Capacitor. It's primarily designed as a backup for laptop. But it's also cleaning my house house of dirty power. So what I am saying is Normally I would be paying for the 180 sudge but only using 120. This Reduces the Problem. My power grids a EXSTREAM example with is why I Got the UPS. But it saves about 15 bollars a month on my eletric bill.
@aduedc
@aduedc 8 ай бұрын
Remember the meter only measures the current (counts current-sec), and assumes value of the PF to be 1 and voltage to be nominal line voltage. So, if you reduce the current your bill will go down. In side a meter there is induction motor in series with your home load, more current it passes through, faster it rotates, and faster it counts.
@MervynPartin
@MervynPartin Жыл бұрын
The main reason for a low power factor incurring penalties is because the distribution network has to carry a higher current and thus there are higher heating losses in those cables/ transformers etc. Also, the cables have to be rated for the extra current.
@eddietee6305
@eddietee6305 Жыл бұрын
That reasoning is wrong.
@sanjyuu2298
@sanjyuu2298 Жыл бұрын
@@eddietee6305 I would be happy to hear your reasoning.
@eddietee6305
@eddietee6305 Жыл бұрын
@@sanjyuu2298 sorry, I meant to say KVA instead of KVARs. Sorry. Commercials buildings are billed for KVAh and not KWH. Domestic homes are only billed KHW.
@sanjyuu2298
@sanjyuu2298 Жыл бұрын
@@eddietee6305 Thanks for clarification :)
@eddietee6305
@eddietee6305 Жыл бұрын
@@sanjyuu2298 ure welcome.
@nimaljayathilaka4718
@nimaljayathilaka4718 Жыл бұрын
Good explanation.very clear. Thanks from Srilanka
@hughleyton693
@hughleyton693 11 ай бұрын
By 7 minutes into this video he correctly says there is NO savings using a capacitor for Home electricity, so those devices are a scam. . . . Factories are a different thing though.
@TheGateKeeper001
@TheGateKeeper001 Жыл бұрын
Thank you for clearing that up for me.
@pauljanssen7594
@pauljanssen7594 Жыл бұрын
It's called phase-shifting it works on AC motors to help motor run more efficiently.
@lakpriyadil
@lakpriyadil Жыл бұрын
Thanks brother, you explained it very well and simple
@nilangaliyanage3833
@nilangaliyanage3833 21 күн бұрын
Its a very valuable explanation for those who are blindly ticktoky. your explanation is perfect.great.
@user-eg5hg3bm9p
@user-eg5hg3bm9p 9 ай бұрын
Thank you for the elaborate and useful explanation.
@Lacaille8760
@Lacaille8760 Жыл бұрын
Maybe this will work when grid consists of mainly of air hanging conduits. (rural areas) But if cables are pulled as ground cables(urban areas), the opposite is often the case.
@rk_bhartiya
@rk_bhartiya 2 ай бұрын
Nothing to do with type of input feeder
@LalithsMusicChamber
@LalithsMusicChamber 9 ай бұрын
Nicely explained. Thank you so much!♥
@user-bn5gs4vs8t
@user-bn5gs4vs8t Жыл бұрын
شكراً لك أخي الكريم على هذا المجهود الرائع جدا جدا
@justsaying4786
@justsaying4786 8 ай бұрын
Seems to me two important qualifications apply here. Firstly the power factor (PF) correction varies depending on the reactive load and that changes as motors, LED lighting and other loads are switched on and off. So the idea that the PF can be corrected by application of a single capacitor is only valid for a given load situation. Putting that aside the other unstated assumption here is that your being billed for the real power component which might be true for domestic households. Large Industrlal users are likely to be charged on total power usage (i.e. apparent power) as a way of discouraging use of high power inducticve loads (i.e. 3 phase motors etc) that do not incorporate some form of PF correction on the equipment.
@davebutler3905
@davebutler3905 4 ай бұрын
You get the picture... PF causes wasted power, so domestic meters charge you for the power you waste. That's why industrial consumers face penalties.
@justsaying4786
@justsaying4786 3 ай бұрын
Should have mentioned there is also a third unstated qualification - all reactive voltages and currents are sinusoidal. This may not always be the case. Some loads (linear power supplies in electrical and electronic equipment, for example ) give rise to current draw with high harmonic content which also contributes to poor PF. A ' capacitor' solution, in this case will only correct the phase relationship between the AC voltage and current and not the harmonic distortion. This is all very case dependent, but serves to highlight again the practical difficulty and limitations of using a single capacitor to correct the PF.
@flagmichael
@flagmichael 2 ай бұрын
@@davebutler3905 Not at all. Consumer level power factor is aggregated and dealt with at the distribution level. The provider that owns the distribution level lines installs remotely operated cap banks to correct voltage levels, usually from day to night. Domestic meters measure Watt hours, not amp hours or VARS. That may be true outside North America or outside Europe or Australia, but I would be surprised.
@timothytamale2600
@timothytamale2600 Жыл бұрын
Thank you. it's so embarrassing that I didn't understand this for all the years I spent in university as an Electrical Engineer until now regardless of how may long pdfs I read, they all made no sense. Thank you Sir.
@radnakse_mada
@radnakse_mada 2 ай бұрын
Don't call yourself electrical engineer
@hphinn
@hphinn Жыл бұрын
Most of the equipment in the house are motor-driven and already have capacitors installed. The biggest culprit is your AC unit. Over the years, the SEER value have improved from less than 4 to greater than 16 and it is mainly due to the improvement to capacitive circuitry.
@allancleofe7842
@allancleofe7842 Жыл бұрын
2:02 ibnibibibiiibibbbbbibbbbbj
@allancleofe7842
@allancleofe7842 Жыл бұрын
ff
@thomaswilson9254
@thomaswilson9254 Жыл бұрын
No that is not correct at all
@hphinn
@hphinn Жыл бұрын
@@thomaswilson9254 So follow the video and place the capacitor by the meter?
@PracticeMakePerfectMuslim93
@PracticeMakePerfectMuslim93 Жыл бұрын
great lesson 😊
@slnrs6816
@slnrs6816 10 ай бұрын
Excellent explanation. In market more devices they are selling in the name of reducing electricity bill which has only capacitor inside. You clearly explained that connecting a capacitor across the power supply will not reduce the bill but at the same time will increase the life and efficiency of our house hold appliances which can reduce the maintenance cost of our home appliances in the long run which infact save our money. Thanks once again. KZbin videos are boons nowadays can easily understand any kind of equipment even without basic knowledge also. Little interest only needs to learn about things.
@vmanstudios
@vmanstudios 4 ай бұрын
Are you trying to say our money will be safe if we add the capacitor across to line.
@flagmichael
@flagmichael 2 ай бұрын
There is no reason to connect a capacitor across the line. We pay for kilowatts, not kilovars (kilo volt-amps reactive). It will not have any effect on the life of appliances; the one factor that will improve the life of your motor operated appliances (air conditioners in particular) is adequate line voltage. Low voltage heats the motor up more than we might think. (Retired after 34 years with a Fortune 100 electric utility.)
@planecrazyish
@planecrazyish Жыл бұрын
Good video. Well explained 👏👏👏👏👏👏👍
@kimkeoelectrical
@kimkeoelectrical Жыл бұрын
Very Good idea thank you for your video
@hosraiyan
@hosraiyan Жыл бұрын
Good video sir,always your explaination understable and clear,Thanks.
@md.ziaurrahman8603
@md.ziaurrahman8603 9 ай бұрын
Capacitors marketed as power-saving devices for reducing electricity bills are often considered fake or misleading. These devices claim to improve power factor and reduce energy consumption, but their effectiveness is questionable. Power factor correction is typically the responsibility of utility companies, and residential consumers rarely benefit from such devices. It's essential to be cautious when considering these products, as they might not provide the energy savings they promise and could be a waste of money. It's best to focus on proven energy-saving practices like using energy-efficient appliances and reducing unnecessary energy consumption.
@CoverageAwarenessStudio
@CoverageAwarenessStudio 5 ай бұрын
I know a few people who used a Power saving device and it lowered their bill by $400, they had two for a 2000 sq ft home. I said add more and then let us know. so they do work you just have enough of them plugged, you cannot just plug in one and expect oh cool it works because one will not work.
@flagmichael
@flagmichael 2 ай бұрын
@@CoverageAwarenessStudio Unless you are outside any modern area, I find that impossible to believe. Throughout North America, Europe and Australia power is metered by the watt-hour, not the volt-amps reactive.
@peternorman2563
@peternorman2563 Жыл бұрын
Sounds good and explains the calculations correctly but most homes in the UK are fitted with meters that only read Kwh and therefore have no reactive component to add into the calculation. The big but is when the electricity company's switch you to smart metering as is happening here in the UK. Its another easy way to charge you for what is known as (wattless current) !
@alanjmasters
@alanjmasters Жыл бұрын
That's interesting. So if I have a poor pf at home best to stay on the old meter.
@eddietee6305
@eddietee6305 Жыл бұрын
You are absolutely right. I'm wondering if the commenters were watching the video. Your home is billed wattage not VA or KVA.
@kennethhepke3264
@kennethhepke3264 Жыл бұрын
It is distressing to watch TV adverts for these devices. What a swindle. I was an electrical engineer in a large factory. Our main load consisted of polyphase motors and other inductive devices. Around the factory were automatic power factor correction units utilising capacitors. This corrected the power factor......How many houses have exclusively inductive loads? Not many!
@jensschroder8214
@jensschroder8214 Жыл бұрын
in Germany the old Ferraris meters only count the active power. The domestic digital meters as well. Expensive measuring systems with capacitive compensation are only available for factories. But connecting a pseudo capacitor to the grid helps the sales of Asian retailers and lighten your wallet.
@linoross7493
@linoross7493 Жыл бұрын
Maybe this will work if the consumer load is inductive paralled to a capacitor to form a tank circuit at the line frequency. Oscillation or fly wheel effect could take place .
@didioentoro7575
@didioentoro7575 Жыл бұрын
Mr. Electrical Guy - if I may suggest, you need to add an information about the advantage of using capacitor is increasing the load - if uses full inductive load at home for example-.
@vmanstudios
@vmanstudios 4 ай бұрын
How do i use inductive load to reduce bill
@safiudeen
@safiudeen 10 ай бұрын
You are using the same power with improved power factor to calculate current, and then again, you are calculating the power using the calculated current. In this, you will get the same power. Energy meter calculates the power consumption of active power. Theorically, the capacitance load will deal with reactive power. Therefore, there will not be any noticeable change in meeter reading. But improving the power factor will help to reduce the current in the line. This is good for the supplier as the voltage drop will be reduced in the supplying line.
@vmanstudios
@vmanstudios 4 ай бұрын
Does it mean that applying capacitor across the line is good and advisable? And it can reduse bill.
@davebutler3905
@davebutler3905 4 ай бұрын
Now you are getting to the point!
@hmtechsvc
@hmtechsvc Ай бұрын
@@vmanstudios imho - no, it's a flawed method of deployment in that use case scenario. a parallel capacitor should only be deployed to inductive loads only. that's only a few things (dryer, washer, dishwasher, range hood, ceiling fans, garbage disposal, vacuum cleaner, fridge and central ac). you can't leave the caps on when the load is not on - if you do then you're just wasting electricity. and forget about everything else for caps - lights, toaster, keurig, microwave - those are all resistive loads. it's literally STUPID to think or calculate what cap is needed for an entire house. the point he's not making is that EXISTING capacitors are typically installed with the startup (inrush) current needed to get the inductive loads going and that each power factor's device can (probably) be improved with the addition of ANOTHER capacitor that brings the power factor of the device closer to 1.0 - but again the bigger the load the bigger the savings and the smaller the load the smaller the savings - and you have to make sure the cap is on ONLY WHEN THE INDUCTIVE LOAD IS ON - here's a better video showing it kzbin.info/www/bejne/ioHUiYGCoK-HgK8 - he buys an $18 cap - after years he will start to realize an roi - and this is what most people bitch about "roi" lol - but if everybody was off grid in the middle of montana - those guys would be in the dark anyway lol - anyway - hope this helps you out man - too many ppl don't explain it well enough - again imho
@supersai1919
@supersai1919 2 ай бұрын
Excelentttttt Bro. Thank you very much for your explanation....
@stevenmoomey2115
@stevenmoomey2115 Жыл бұрын
I got to test one of these Capacitor Banks. What the person that loaned me the device didn’t know, was what instruments I had. Assumed just a DM and Amp Clamp. Installed new Double Pole 15 Amp Breaker in Panel wired in Device. With the Breaker off Ran Major Appliances except Clothes Washer, for twenty minutes and took Watt readings. Also Dryer was run on a high heat, non-Auto dry setting. Freezer, Refrigerator and AC Ran at a slightly lower wattage, with the unit connected. Also a large belt driven floor fan Ran at a lower wattage. When I set the Clothes washer so it was heating it’s water it ran at a higher wattage. Next was the Water Heater, our biggest energy hog. It ran at a higher wattage with the Capacitor Bank Connected. Stove/Oven, Dryer Light Bulbs were all higher. Any Inductive load ran higher wattages. This would have resulted in higher electricity bills in my opinion. BTW Fluorescent Lights quieted down, and my immersible aquarium pumps lost there hum, and ran at a lower wattage. My old O Scope showed a smoother Hz Wave.
@joshuacherian6718
@joshuacherian6718 Жыл бұрын
Good presentation.
@HerbertDaure
@HerbertDaure Ай бұрын
It really interested to me to know, thanks
@maas1728
@maas1728 7 ай бұрын
Thanku bro good & use full video
@davethemmp
@davethemmp 2 ай бұрын
Most countries like Canada and USA don’t charge for poor power factor in residential only in Industrial this is where it really matters
@AsianTechnic
@AsianTechnic Жыл бұрын
Excellent explain i ❤it
@anthonywangai
@anthonywangai Жыл бұрын
How do i know if myload is leading or lagging and with what power factor so that i can be able to calculate the microfarad that i need
@johnbutler3141
@johnbutler3141 8 ай бұрын
Will it reduce the bill if I put it before the meter ? What size capacitor would you need for an 80 amp supply ?. Great explanation.
@JonalistTwitMe
@JonalistTwitMe Жыл бұрын
Making a change to the output of thye meter will not affect the billing rate of the input to the meter, its a waste of time to consider the public could benefit by adding a capacitor to their output side of the power meter even if part of the home or business were to be rented, the same power billo still results. Surges in power is not a good thing esp for Internet electronic equipment which would be crowded with a noisy line decreasing quality of service.
@shivamurthym6205
@shivamurthym6205 Жыл бұрын
all home , electric motors (fan ,washing machines, water pump)and electronic equipment already installed with capacitors . no need extra capacitors
@tulsiramnaidu2894
@tulsiramnaidu2894 Жыл бұрын
It's all bull
@hajinoorahmedjahejo3185
@hajinoorahmedjahejo3185 Жыл бұрын
Which value of capacitor installed.
@joaquinrabelas8338
@joaquinrabelas8338 Жыл бұрын
MORNING FRIEND WHAT VALUE OF CAPACITOR IF MAY CURRENT 220 VOLT LOAD 3K TO 5K ,THANK YOU ..
@tomasbas640
@tomasbas640 Жыл бұрын
What is the value of capacitor
@Equiluxe1
@Equiluxe1 Жыл бұрын
Here in the UK homes are only charged for real power and not apparent power so power factor correction will not make any difference to the meter bill. In fact putting a capacitor across the incoming supply will increase your bill as the capacitor will pass current for which you will be charged. I suspect that with the advent of smart meters it is only a matter of time before we get charged for apparent power, which will mean that all those switch mode power plugs will start costing a fortune as will the capacitive dropper LED lamps.
@egria
@egria Жыл бұрын
I suppose you are right about billing for reactive power (kvar) for home consumers. Marketing campaign will be 'Did you know that you rob poor power utility company? Now you must pay!'
@ronrollins381
@ronrollins381 Жыл бұрын
The change in the current by the addition of a capacitor will not change your bill. As you indicated, as a residence you are billed on watts (real power). The presence of the capacitor does not affect the value of the real power.
@vmanstudios
@vmanstudios 4 ай бұрын
What is the beat thing to do, cause i want to reduce my bill.
@Equiluxe1
@Equiluxe1 4 ай бұрын
@@vmanstudios Turn things off and unplug them when not in use is about all you can do. If you are somewhere in the world where you do get charge for reactive or apparent power each and every item will need a corrective capacitor and this has to be calculated for every one, you can't just go putting capacitors in the circuit and hope it works, and this only really works for things with a steady power draw any equipment where the power goes up and down like a washing machine will need an active power correction circuit built in.
@abieladanga3111
@abieladanga3111 2 ай бұрын
Interesting in your video
@VeritasPraevalebit
@VeritasPraevalebit Жыл бұрын
This is correct. The meter does not charge you for inductive or capacitive load. But these loads will cause losses in the power grid transmission lines. Fluorescent tube lighting fixtures contain a current limiting inductor and this usually is balanced by a capacitor of appropriate size. Still, the tube would work just fine even without the capacitor.
@flamingo5900
@flamingo5900 Жыл бұрын
No. Indian meters charge depending on KVA.
@VeritasPraevalebit
@VeritasPraevalebit Жыл бұрын
@@flamingo5900 This may apply to commercial but probably not to private users. Even if it does, a single capacitor would not be of much use. Instead each inductive load would need its own phase compensation capacitor, just as is done on fluorescent tube lights.
@flamingo5900
@flamingo5900 Жыл бұрын
@@VeritasPraevalebit What you say is right. Compensating capacitor should be on only when the device is on. There is no pf correction capacitor in fluorescent lamps.
@flamingo5900
@flamingo5900 Жыл бұрын
@@VeritasPraevalebit In India different rules are there for different states.
@deang5622
@deang5622 8 ай бұрын
The old mechanical kWh meters with a spinning disc only measured real power and could not measure apparent power. However with the introduction of smart meters in some countries, they do have the capability to measure apparent power, and even in a residential setting. In the UK they haven't activated that capability yet. Apparent power is rarely measured in residential properties, and most often only done in commercial/industrial properties. One typical approach is to set a threshold for the power factor and make a charge to the industrial/commercial customer when the power factor goes below the threshold. This generally tends to act as an incentive to the industrial customer to adopt power factor correction techniques and devices. Too many customers with too low a power factor imposes demands on the infrastructure which the power company (or distribution network operator) incurs costs to provide. So to prevent them having to upgrade the network at huge cost, they discourage low power factors.
@lucientjinasjoe1578
@lucientjinasjoe1578 Жыл бұрын
Only inductors can manage for fase correction and with capacitors
@waynethomas3638
@waynethomas3638 Жыл бұрын
In Kalgoorlie/Boulder(western australia) the local power supply had capacitors in all meter boxes to compensate fo power factor. BUT WHEN CONNECTED TO STATE SUPPLY THESE CAPACITORS WERE REMOVED
@jensschroder8214
@jensschroder8214 Жыл бұрын
because households today have fewer neon tubes with inductance, but more LEDs with capacitive power supplies, phone chargers and other capacitive consumers
@HamzahVerster
@HamzahVerster 2 ай бұрын
Very informative. Another words, ohms law apply. . .
@vettalan
@vettalan Жыл бұрын
For home please mention the capacity of capacitor (MFD)
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Dear for you I made a dedicated video for you on how you can select the capacitor size to save electricity bill of your home, you can watch that video 👇👇 kzbin.info/www/bejne/Z5SxlpyXbqlofM0
@alexanderv.k1696
@alexanderv.k1696 11 ай бұрын
This capacitor device is useful if the house has several motors running 24 hrs 365 days like in a factory. If not, the power bill increases abnormally, at least by 20-30%
@vmanstudios
@vmanstudios 4 ай бұрын
Can a motor safe bill.
@ricolimbo3444
@ricolimbo3444 3 ай бұрын
Thanks for information I ask I thing what is the value of capacitor you used for 1000w consumption.
@chrislundberg1
@chrislundberg1 8 ай бұрын
Might help with power surge at power on and then settle to normal other, like motors will zap 1000 watts and settle to 500 watts. Doesn't seem to be enough help to make a bill difference.
@jfbaro2
@jfbaro2 11 ай бұрын
Is there any viable (< USD 1.000) device that can keep the voltage/tension coming from the GRID more stable (~10V)? Like, it tension goes over the excess is discarded and if goes under then a super capacitor complements the current to keep it stable (transparent to the home appliances).
@vikram-xd9ld
@vikram-xd9ld Жыл бұрын
Hi when we use motors, like fans, grinders and AC etc.. when we switch on sudden change in voltage drop is happens, to arrest that we need capacitors after switch individually. its also regulate power factor. this method controls sudden voltage drops and increase motor life. Most of the industries people use this method. but remember we have to connect before motor, parallelly to be connected. Otherwise it draws some power and bill will be increased
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
you are correct
@vini5971
@vini5971 Жыл бұрын
Smart one
@flamingo5900
@flamingo5900 Жыл бұрын
You are wrong. Capacitors can not be used to store electricity in AC circuits. It is for correcting power factor.
@sijithloy5894
@sijithloy5894 10 ай бұрын
The capacitor cannot be connected between the neutral line and the phase line, as you have shown in the diagram.
@denniskarley2824
@denniskarley2824 Жыл бұрын
Good one there!!!
@gvkrishna383
@gvkrishna383 3 ай бұрын
For industries, discoms billing on KVAH meter values. So if u don't maintain PF, ur bill will be little bit more when u compare with when u maintain PF as unity. Thats why in industries, we always try to maintain unity PF. If u maintain unity PF, the stress on cables will reduced
@SW-hw1mm
@SW-hw1mm 6 ай бұрын
Three phase service ... pf correction for a "Demand Meter" type commercial service to a business? Yes 👍 Single phase service to a residence? Waste of money!
@flyer617
@flyer617 8 ай бұрын
Whether or not this works depends on the type of meter and the power factor before and after you add the capacitor. I had a friend install a bank of 3 phase capacitors at his plant because he was being billed for poor power factor due to a large number of motors making it very inductive. Some quick calcs and his electrician installed the capacitor cabinet and it saved a lot of money each month as the new power factor was close enough to one to eliminate the additional charge. I doubt a capacitor will do much in most residential settings and it adds a component which if not installed properly and with the correct fuse could start a fire, so I wouldn't recommend it. Be careful.
@pierrelombaard820
@pierrelombaard820 5 күн бұрын
I only read some comments afterwards they explained their tests with equipment somtimes good sometimes bad worse A powfactor not equal to 1 will cost extra. Lagging ( motors) or leading ( capacitive load, say a capacitor bank ) A factor lagging more than than 0.6 say 0.55 wil let the meter reverse There is no way that you combined use is as bad as 0.9. so 0.6 is worst case scenario Geyser and stoves and heating equipment use the most electricity, at a powerfactor of 1 Only motor devises ( small. 250 watt excetra, example ) Fridges, pumps an fans that is driven by motors will affect the power factor negatively ( but they are small devices ) Called lagging power factor But not.at a rate as bad as 0.8 combined If you want to install capacitors on those motors you can, but as close to the motor as possible, when they run to take the powerfactor closer to 1.0 But you can not use a single capacitor bank If the motors are not running You pay for the leading factor fault wich is just as bad In factory's a system that use synchronous machines is used to correct the factory supply ( use ) powefactor to reduse the bill
@jdlech
@jdlech 2 ай бұрын
Three things to consider here. 1. this video assumes an "ideal" capacitor. Real world capacitors have leakage current, however small,, that will increase overall consumption. Even if by a tiny amount. 2. I used to add small capacitors to Edison bulbs whenever that socket had a history of blowing bulbs. Wherever the spike happens to come from, a capacitor will help prevent it from burning out the bulb. It may even work on modern LED lights, though they are naturally more resistant to voltage spikes. This saved me a lot of money in replacement light bulbs over the years. 3. capacitors fail over time and use. They can short out and cause a fire. Never bypass a fuse or circuit breaker with a capacitor. And never place one in a location where its failure might ignite nearby material.
@TravisCreighton
@TravisCreighton 11 ай бұрын
Does the improved working of the load by improved PF reduce heat and thus either finish having utlized less energy or save through secondary costs such as air conditioning due to less heat generated?
@PK-nv4on
@PK-nv4on Жыл бұрын
Your video is ok while the billing is done on active power called kwh. But, now the EB s are billing on reactive power which is called kvah which is more than kwh , when we use inductive loads, ie motors, fans, ACs etc... So in Telugu states, better install suitable capacitors to improve the power factor nearer to 1, so that the bills are reduced. As of now, there is no low power factor charges seperately.
@angelzahrah1038
@angelzahrah1038 Жыл бұрын
😅😅8fico😂
@eddietee6305
@eddietee6305 Жыл бұрын
Who getting billed for active power other industries?
@bindiberry6280
@bindiberry6280 Жыл бұрын
More than capacitor, Tesla inductance coil towers resonances can draw quite a lot of electrons from the Earth ground in the form of the displacement current.
@vijayakaranr1279
@vijayakaranr1279 4 ай бұрын
Nice explain
@naturetruth5218
@naturetruth5218 2 ай бұрын
What this video said is true. It all depends on how the utility company charge: Real power consumption or supply power. In residential, its usually charge on real power consumption, that's why installing any PF improving capacitor device will not help save your bill but only for utility company. Which is why i never install any PF improving devices for my home, and discourage non commercial buildings like schools to install such devices as they also consume extra power. But an improved PF does help prolong the lifespan of your supply lines and some devices as less current is required to do the same jobs thus less deterioration rate. It also help old induction motors without PF corrector to run more efficiently. Its usually in commercial and industrial area that utility company imposes a penalty for poor PF to force them improve their PF efficiency, esp for those consuming large power using inductor motors. I was assigned a project to improve PF for a hotel during my university industrial attachment, learning from utility supplying professional engineer. It did cut the large utility bill significantly after improving the PF.
@flagmichael
@flagmichael 2 ай бұрын
In every civilized country I know of, electricity is sold by the kWh. It is the responsibility of the provider to deal with power factor. Most of that is done at the distribution level, with some at the transmission (the power lines we see a mile away) level. Generally, distribution and transmission level cap banks are remotely controlled based on the line voltage.
@rbspider
@rbspider 10 ай бұрын
I have been saving thousands a month with a capacitor and green led plugged in even though my monthly bill started out at less than fifty a month. Amazing.
@jagsank1k2
@jagsank1k2 Жыл бұрын
EXcellent explaination of PF and why electrivity bill does not reduce even when pf improves.
@user-wn6ov3rv9b
@user-wn6ov3rv9b 2 ай бұрын
I have always thought that by using a capacitor prevents the startup load, which can be ten time the actual load. This may not have much effect on your bill but if you are off grid and run batteries then it can help the longevity of the batteries as the capacitor can release power faster
@subratasen6205
@subratasen6205 Жыл бұрын
How do you stabilize supply voltage during hot summer ???
@kifayatullah5929
@kifayatullah5929 Жыл бұрын
Not possible only Amps can controle but the bill will same.
@debojyotiroy7150
@debojyotiroy7150 10 ай бұрын
Well, all said and done. But what should be the capacity (mf) of the capacitor ? For how much current (Amp) ?
@dadivenkatarao
@dadivenkatarao 10 ай бұрын
Have you done it real time for home appliance with various loads of appliance.?
@nahahvarietychannel3293
@nahahvarietychannel3293 Жыл бұрын
Capacitor bank only to improve power factor.
@mohdzaidi1631
@mohdzaidi1631 11 ай бұрын
Hummm... Hai from Malaysia... Discus about power factor... Every house used electric not same...first thing U must calculate how many capacitor(uf ) to used.if wrong used big size capasitor will be bill more than normally... My house using 15uf, monthly bill decrease 9%-12%
@deepnaik5467
@deepnaik5467 Жыл бұрын
Which Capacitor value to be used...
@flagmichael
@flagmichael 2 ай бұрын
None. This video is based on a misunderstanding of how our consumption is measured.
@govindmalhotra428
@govindmalhotra428 Жыл бұрын
Thanks, Mr Arun , I m agree with you on this issue, but I don't agree with that that a capacitor improves the life of an electrical device because a capacitor ( after with appropriate calculated size ) only reduces the current before the junction point of that equipment and capacitor, and not after the same, so therefore the current of the equipment will be the same as in previous condition, then how can it will save or increase the life of that equipment? Please tell me if I am wrong there,
@ronrollins381
@ronrollins381 Жыл бұрын
You are correct.
@govindmalhotra428
@govindmalhotra428 Жыл бұрын
@@ronrollins381 Thanks
@khalidsagmani6456
@khalidsagmani6456 3 ай бұрын
Unlike the battery, a capacitor is a circuit component that temporarily stores electrical energy through distributing charged particles on (generally two) plates to create a potential difference. A capacitor can take a shorter time than a battery to charge up and it can release all the energy very quickly.
@subash06
@subash06 2 ай бұрын
Theory is old age , demonstration with live devices makes sense
@kasiathithasolan8522
@kasiathithasolan8522 9 ай бұрын
Thanks bro
@UNKOWN_SOURCE
@UNKOWN_SOURCE Ай бұрын
Yes it can correct power factor issue.
@alanhurdle3949
@alanhurdle3949 Жыл бұрын
Thank you this really help me, I hoping some day it will be a project for the children magnetic generator D/C alternators knowing how much wattage 240 amps common house use to be 60 Amp at one point there a reason for that no had anything that took electricity lol haha to fun but true! Radio and party phone that's all oh ya an outhouse I wasn't far from those days! As the Grandfather of Electricity once said free electricity he meant he was going to make it and send it to you free from wires I took it one step farther teach the people to make there own free electricity cause we know how to make all we need is to safeguard but this gave me more I almost forgot transferring Thank you
@etmax1
@etmax1 Жыл бұрын
What happens with this is that you make your house a reactive load rather than largely resistive. The power companies can measure this when a lot of people do it and then they change your meter to a reactive meter and bill you through the nose. It's just like when people living near transmitters or high voltage lines use various methods to steal power (yep its theft) they end up paying the price anyway.
@tikka1967
@tikka1967 Жыл бұрын
Put cap ..and put PF ,watts meter ..switch off all everything in house .......look pf meter ..
@teslapark3406
@teslapark3406 19 күн бұрын
Good job, now explain how those LED light bulbs actually save money for the same amount of light.
@gerritbrink3430
@gerritbrink3430 Жыл бұрын
Hello Sir, I do have a capacitor 35 uF nom. spanning 1400 volt, is these need to install?
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Capacitor value will depend on power factor require for improving, i will make a video on it soon
@TahirIqballovsabi
@TahirIqballovsabi 3 ай бұрын
The simple way to save electricity to use the dc appliance and use the solor panal charge controller and battery , alteast the portion or 8 flat bulding should do the simple shared setup to save the electricity
@simonsalihu4682
@simonsalihu4682 Жыл бұрын
Qhat happen when the capacitor is connected to the imput line, i.e. b4 the meter
@watahyahknow
@watahyahknow 2 ай бұрын
i seen it done on mecanical electricity meters , they used a transformer (or a coil) though , makes the meter run in reverse wat i remember they placed one lead under the meter one above and one to ground
@unnikrishnanmullassery9651
@unnikrishnanmullassery9651 8 ай бұрын
Can you please explain the same as for three face connection
@benjaminandati6323
@benjaminandati6323 Жыл бұрын
Which type of capasitor how many urf good video sir
@didioentoro7575
@didioentoro7575 Жыл бұрын
AC type capacitor is needed and the value of capacitor is depend on the inductive load. Inductive loads are transformers and motors inside the equipment...e.g. Tube Lights, water pump or any kind of pump, freezer, refrigerator etc.
@TheElectricalGuy
@TheElectricalGuy Жыл бұрын
Dear for you I made a dedicated video for you on how you can select the capacitor size to save electricity bill of your home, you can watch that video 👇👇 kzbin.info/www/bejne/Z5SxlpyXbqlofM0
@rchn9953
@rchn9953 4 ай бұрын
It's not the p.f aspect. The harmonics and transients contribute to parasitic current consumption. Capacitors partly reduce harmonics and transients, so the loads produce less harmonic currents. Some digital meters are not calibrated for harmonics and may excessively render kWH. Besides cost-saving: 1) equipment will last longer. 2) better health due to reduced harmonic electric and magnetic fields. For these benefits, the capacitors are installed just before the fuse box.
@k-mtan1970
@k-mtan1970 Жыл бұрын
our home meter don't register the KVar... only the active power is registered, so why u need to use cap ??
@integer9655
@integer9655 11 ай бұрын
bro are you new on this? 😂
@frankhaydon658
@frankhaydon658 8 ай бұрын
would a capicitor in front of the load reduce power surge and reduce the " demand charge" by the utility compandy? they charge up to 3 times the base rate for demand usauge. thank you.
@lightice7029
@lightice7029 2 ай бұрын
Great
@sivadast.p.727
@sivadast.p.727 Жыл бұрын
Actually the Indian service Meters slowes when connected atter the meter But it also slows Induction based equipments!
@rajeshkumarsingha8129
@rajeshkumarsingha8129 8 ай бұрын
Gd mg sir, hindi mein video banayin. Thanks.... 🙏🙏🙏
@rockskipper5353
@rockskipper5353 6 ай бұрын
So does a pure sine wave invertor work like a capacitor , other than it doesn't hold a charge ?
@pauljanssen7594
@pauljanssen7594 Жыл бұрын
This is a very old concept get a book watch one of the old older videos of power bouncing it only works on induction devices.
@danzelwesingtone7413
@danzelwesingtone7413 Ай бұрын
Thanks, by the way what's the rating of the capcitor
@samuelramesh8621
@samuelramesh8621 Жыл бұрын
@The Electrical Guy The point is that the energy company charge on real power consumed which is watts/hour, were as they do not charge for apparent power which is VA/hour. Power factor = real power (W) / apparent power (VA), since the power is charging for watts/hour, we must make sure the power factor equals unity (1), otherwise the power company is losing and using high amps will heat the power lines more, and lot of energy is wasted as heat. Therefore the power company wants to reduce the energy loss by maintaining unity power factor (1).
@flamingo5900
@flamingo5900 Жыл бұрын
It depends. In our place electronic meters are used and we are charged depending on the kva. Soon they will be bringing different rates for peak hour consumption. That is already announced.
Ceiling fan Step by step proper connection with capacitor @TheElectricalGuy
8:36
Power Inverters Explained - How do they work working principle IGBT
13:39
The Engineering Mindset
Рет қаралды 3,6 МЛН
THEY made a RAINBOW M&M 🤩😳 LeoNata family #shorts
00:49
LeoNata Family
Рет қаралды 32 МЛН
Alat Seru Penolong untuk Mimpi Indah Bayi!
00:31
Let's GLOW! Indonesian
Рет қаралды 15 МЛН
🌊Насколько Глубокий Океан ? #shorts
00:42
THE POLICE TAKES ME! feat @PANDAGIRLOFFICIAL #shorts
00:31
PANDA BOI
Рет қаралды 24 МЛН
The Big Misconception About Electricity
14:48
Veritasium
Рет қаралды 22 МЛН
We Cut Our Electric Bill in Half in About 6 Weeks!
33:50
Under the Median
Рет қаралды 437 М.
Where Does Grounded Electricity Actually Go?
19:36
Practical Engineering
Рет қаралды 5 МЛН
Chinese Power Saver - Does it actually save power?
5:37
GreatScott!
Рет қаралды 1,5 МЛН
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 1,7 МЛН
How to make power saver device for home with scam proof
10:52
Let's See Inside
Рет қаралды 1 МЛН
I bought a scam energy saver and made it actually save energy!
2:50
Matthias random stuff
Рет қаралды 406 М.
THEY made a RAINBOW M&M 🤩😳 LeoNata family #shorts
00:49
LeoNata Family
Рет қаралды 32 МЛН