⚠️ *Found this video super useful?* Buy Paul a coffee to say thanks: ☕ PayPal: www.paypal.me/TheEngineerinMindset
@DubaiVlogggg7 жыл бұрын
The Engineering Mindset which country are you from?
@cata72514 жыл бұрын
Coffee is served from my side! Keep going. Thnks!
@timmyfoltz20223 жыл бұрын
@@cata7251 p
@timmyfoltz20223 жыл бұрын
pp
@eulaliorodriguez5325 Жыл бұрын
Thank you for sharing this HVAC VIDEO.
@harvindersingharora38454 жыл бұрын
You are my teacher of the day! Thank you.
@STEINYY4 жыл бұрын
Hey Paul, how are ya? I was wondering if you could make another video about troubleshooting? Common faults with AC units, chillers, heat pumps? I would like a video like this, it was helpful for me. / Lineus
Isues lot off dis charge sushion gas low fult trobels alrom dis plsy and tdmpseting very imprsnted pump watr pslow lording cooling effeating condeder celin pm must condesfsn snd aif folw swich wofkinv lot ful dolvrig mattrs
@chooonz13966 ай бұрын
We have Flow sensor Issue. Chiller 2 shuts down and shows "waiting for evaporator water flow". We already tried swapping the flow sensor and tried it on Chiller 1, both flow sensors from Chiller 1 and 2 functioned well in Chiller 1. Is it a communications issue? What should we do to troubleshoot? Should we just contact the supplier?
@mohdal-ameed68313 жыл бұрын
Thank you.
@manikantabalusa4415 жыл бұрын
Pls upload a video of preventive maintenance activities for water cooled and air cooled chillers
@delrey-p Жыл бұрын
It would probably be a 3 minute video mate. Very simple to do. The title PPM says it all.
@Afzalkhan-tk9mv7 жыл бұрын
sir make a vedio on how calculate usgpm of water ...and selection of pipes in chilled water cycle and condenser water cycle
@muhammadazhariqbal53044 жыл бұрын
can i connect evaporator inlet from cooling tower instead of water tank will it effect ? thanks in advance
@akashgayakwad39292 жыл бұрын
ln my lab chiller is showing 50degree centigrade temperature of collent since actual measured temperature of collent is 20 degree. please suggest me a proper solution of this issue??
@ejazahmed11312 жыл бұрын
Hi I have chiller 30ax carrier I have problem compressor started but condenser fan not getting started Pls advise me
@amiramjad2022-v1e4 жыл бұрын
Hi thanks for your amazing videos you can talk and expalne how to setting CLIVIT CHILLER PLZ
@christopherwheaton282 Жыл бұрын
Hi can I still drive when the chiller tripped out only have chiller thanks
@zoransvracic32196 жыл бұрын
is there any step by step guide on how to preform leak check of chillers?
@brandonmccary272 жыл бұрын
What does ‘ latched - fault mean on screw air cooled chiller
@porfiriofranco50703 жыл бұрын
Hi, why the main cause for frezzing in the evaporator??
@shashishashidar96492 жыл бұрын
Trane CDHG water cooled chiller Refrigerant- R123 Problem- chiller not going load more than 80% and not achieve set temp,we changed leaving water sensor,saturation temp sensor,refrigerant charged,manually igv open,water flow is normal but still problem not solved,please suggest me
@sonudandiwal777 Жыл бұрын
When chiller running igv not properly open but hot bypass line open around 70% open so chiller not working properly
@engeng30125 жыл бұрын
Hello guys...i want your help in this i am still newbie with hvac system and in the place where i work there is swas chiller. From time to time cause high pressure alarm..what do you advice me to inspect which part..i inspected condenser filter and fan motor.. plz i need your help with that..thx
@EngineeringMindset5 жыл бұрын
Condenser water temperature is most likely the cause. Check the chiller error code and temperatures
@engeng30125 жыл бұрын
@@EngineeringMindset I would like to thank you for the quick reply .The chillers are using at the power plant are air chiller not water chiller. Today we had low pressure alram so churged with refrigerant and make sure that the valve expansion and pipes are intact. 3 chillers low pressure alram and one chiller is high pressure.the set point on 77 f. What do u expect????? Thanks Again
@miguelloza44546 жыл бұрын
Hi I’m having trouble with a bitzer compressor i replaced oil pressure switch and now compressor won’t come out of pump down or go into refrigeration mode any suggestion on wat to check
@gabrielvillanuevaiii39266 жыл бұрын
Miguel Loza check for a possible defective low pressure switch or one that is improperly adjusted
@ndzondelelojekeqa57786 жыл бұрын
Guys watter chiller is not running HI Temp Tripped light is on help me what I need to do
@gabrielvillanuevaiii39266 жыл бұрын
Ndzondelelo Jekeqa If it is a high refrigerant temperature/pressure alarm on a water-cooled chiller, check the condenser pump strainer. If it is on an air-cooled chiller, check the condenser fans if they are operating correctly
@EngineeringMindset2 жыл бұрын
Seen our new pressure switch video? Link: kzbin.info/www/bejne/j3ibYqpmfauLhMU
@Your_searching_ends_here6 жыл бұрын
Explain about chiller anticycle
@alinusrath54312 жыл бұрын
Patra Chiller commpresor proof faulty how to mack pls tell me vedio
@nasimahmadkhan29545 жыл бұрын
Please you help 20 ton LG package unit 5 ton compressor section line hitting what problu?
@anishkhananish7994 Жыл бұрын
The aircon chiller error -93 comming what problems brother
@ahmedazhri91265 жыл бұрын
Thanks for your lecture I have some questions My chiller trip on low pressure in evoprter
@Apkaa5 жыл бұрын
Elaborate bhai
@azinuddinasri33943 жыл бұрын
You need to get the diffential pressure between in and out as per chiller requirement, need to get peformamce data from supplier and check the differential pressure, then u need to adjust your butterfly valve accordingly to get the right pressure
@franklinknight14605 жыл бұрын
How can I troubleshoot if one cooling tower, one condenser water pump and one chiller water pump are not working. help me please?
@EngineeringMindset5 жыл бұрын
Check the chiller or bms screen for error codes. This time for year its probably low temperature and the chiller has tripped to protect itself
@charlitomarcosjr10575 жыл бұрын
How to fix low discharge superheat in york chiller?
@Enayatmauna6 жыл бұрын
what types of problems create in chiller plant
@md.perwez21793 жыл бұрын
Please review this video and read the screen
@danellim25535 жыл бұрын
my client's chiller circuit board burn cause by lizard... another one is fan and compressor not running. the control shows E 26 was error.. ps: im new to it
@marcusjones86834 жыл бұрын
How do you bleed a chiller unit
@vishalsalve22616 жыл бұрын
sir please tell me about antifridge activatedalarm
@vinznes77925 жыл бұрын
How to do if got alarm c1cmp1 off motor temp high
@ashaoluadeleke99065 жыл бұрын
Please how can I clears the fault using the keypad for York chiller
@jthigpen29675 жыл бұрын
log in service menu then clear the fault. if you don't have the code stay out of it and call your local service agency
@Bhajankerasik4 жыл бұрын
Low amps drawn by compressor??
@shaikhrahman18483 жыл бұрын
Please discharge temperature high alarm
@hamidjamal97402 жыл бұрын
Troubleshooting pdf link please
@mdafaquealam60704 жыл бұрын
Motor temperature highin aircooled screw, what is problem
@christopherwheaton282 Жыл бұрын
Temp on dash ok can't turn chiller on hot under bonnet. Is it OK to drive without chiller
@masterchef66947 жыл бұрын
Thanks for sharing knowledge. Could you do a video on ahri standard for rating chiller performance data.
@anamsiddique137 жыл бұрын
I have problem rtaa 430 chiller latche fault any body help to solve this
@ahmedazhri91265 жыл бұрын
What is the solution
@SoldadoJESUSCRISTO2 жыл бұрын
Different color on merchandise please!?
@asadmehmood80656 жыл бұрын
Sir Kindly Send me Softcopy of Chill fault and trouble shooting
@IftikharAhmed-qi2sw5 жыл бұрын
How to check heat exchanger seance chiller complete b m s control chiller fully shit Dow
@jollyscaria192211 ай бұрын
Prmary pum secndry pump wate flowing valve oponed full checking prssur dros up line allchecking very imprsnted
@EJD3394 жыл бұрын
Any building automation techs watching this video?
@Suneelkumar-zu7om3 жыл бұрын
Good Night
@Learntogether20516 жыл бұрын
How to start a mcquay chiller
@EngineeringMindset6 жыл бұрын
Find the description of operation manual for the building and the manual from the manufacturer.
@Your_searching_ends_here7 жыл бұрын
If surge happens in chiller... Chiller won't shutdown ah