No video

Installing A Mini Split in 60 Seconds

  Рет қаралды 1,030,283

The Handyman

The Handyman

Күн бұрын

Subscribe and watch the full video.

Пікірлер: 359
@michaellines4352
@michaellines4352 Жыл бұрын
Best video ever!!! No long talks no bs straight to the point. You da man. Thanks
@wildoutrudeboy
@wildoutrudeboy Жыл бұрын
But all that dust got on the outdoor unit while boring the hole....right?
@samw6048
@samw6048 Жыл бұрын
I know, I hate all that yacking. 😅
@Sidfields789
@Sidfields789 5 ай бұрын
If I'm not mistaken this is not a job for a diy homeowner. You need a licensed electrician to set this up.
@Casanova42024
@Casanova42024 5 ай бұрын
​@@Sidfields789if you have a electrician put a 220 quick disconnect outside you can do the rest if you know what your doing. I have installed ac where you need to braze and I only have my epa
@Sidfields789
@Sidfields789 4 ай бұрын
@@Casanova42024 This would not be allowed to be performed in my area without a proper permit, and I don't think they would give you one without a license.
@SolidNate99
@SolidNate99 Жыл бұрын
real men drill holes through bricks.
@user-tn9dz7bw5j
@user-tn9dz7bw5j 11 ай бұрын
Where are u supposed to drill of u don’t drill into bricks ?
@eksine
@eksine 10 ай бұрын
real men use their fists to punch holes thru bricks because they dont have the right tool
@eksine
@eksine 10 ай бұрын
@@user-tn9dz7bw5j your eye
@dragonballzmanish
@dragonballzmanish 10 ай бұрын
​@@eksineagreed
@goodvibes_and_music
@goodvibes_and_music 7 ай бұрын
​@@eksineonly in Russia
@MeticulousTechTV
@MeticulousTechTV Ай бұрын
I’d just like to point out to commenters that electrical has been 120/240 since the 1930s. Yes there is a variance in the actual value being supplied by the electric company, but that’s what it is both supposed to be and what it should be referred to. Not sure why people STILL say 110 and 220.
@roynishchand498
@roynishchand498 12 күн бұрын
Hey not judging your work. Good installation. But just a question. Do you pressures test the unit and vacuum with a micron gauge on. I do all this before opening the valves and releasing the refrigerant in the system. Its a good practice.
@vw_mods_4711
@vw_mods_4711 8 ай бұрын
For best results with flares always use a torque wrench, and do up to the manufacturer specifications. Pressure testing the pipe work you installed with OF nitrogen and checking the joints with bubble leak detector is a key step missed! especially if you don’t have certification to buy the gas that you may loose if it starts leaking once you have released the refrigerant! People skipping steps is what gives these units a bad name!
@DPMechanical1
@DPMechanical1 7 ай бұрын
Or a micron guage
@user-xv9dz9zp3s
@user-xv9dz9zp3s 4 ай бұрын
Yeah never checked microns. These are the dudes I go behind on (pause) lol
@boblatkey7160
@boblatkey7160 Ай бұрын
You don't need certification by the gas. I'm an every day homeowner and I just got mine delivered to my door.
@m.vasquez2640
@m.vasquez2640 Жыл бұрын
why did you skip the electrical part of the install?
@jacobfernandez6055
@jacobfernandez6055 Жыл бұрын
He couldn't fit it in 60 seconds and make it trackable I guess
@trueforum378
@trueforum378 11 ай бұрын
It’s basic wiring no big deal
@OregonSpey
@OregonSpey 10 ай бұрын
Actually, unless you’re a licensed electrician, you cannot install a shut off which is required (unless it’s your own home doing it yourself). He probably had called an electrician out to install the shut off for him.
@asiabrilliance7162
@asiabrilliance7162 9 ай бұрын
Because you can use a 120 v outlet for it.
@trueforum378
@trueforum378 9 ай бұрын
Really? I thought they come in as 220 volts only? Thanks
@hhova29
@hhova29 Жыл бұрын
Nice. I hear these leak pretty easily over some time.
@Lkom24
@Lkom24 Жыл бұрын
If installed by a hack..they should never leak
@onua1522
@onua1522 Жыл бұрын
The commonly leak when not torqued correctly. If torqued correctly, you shouldn't have any leaks.
@GoldDiamond-qr8qf
@GoldDiamond-qr8qf 11 ай бұрын
They leak only if evaporator joint pipe is bent, which this guy did. It should never be bent like that. Hole should have been done on left side, the pipe joints are suppose to be inside the house, hidden behind the indoor unit.
@jammiejacobz9593
@jammiejacobz9593 8 ай бұрын
No I disagree. Pipe joint stays outside imo. Makes it easier for servicing and whatever
@dustinpomeroy8817
@dustinpomeroy8817 2 ай бұрын
​@@jammiejacobz9593I agree fuck that shit
@garydavidson6917
@garydavidson6917 2 ай бұрын
yup, he makes it look easy - but i tried and failed - so i hired a contractor and he installed it for me. but before he could do this i had to lay cement down to place the AC on it - then i have to bring a 220 power line (i believe) to it. it was a nightmare!
@angetodac
@angetodac 2 ай бұрын
Nothing about price like usual. I have a budget of 200 for this. Is it enough?
@garydavidson6917
@garydavidson6917 2 ай бұрын
@@angetodac - i supose if u can do it yourself! I couldn't
@dangkolache
@dangkolache 2 ай бұрын
​@@angetodacI spent 1000ish on my senville 24k and then another 800 for all the tools, vac pump, gauges, concrete, direct bury romex, etc. so I doubt 200 will get you far. However it still saved me 3k based on quotes I got from HVAC installers for the same setup, and about 1.5k cheaper than mr cool (this is all USD)
@tobsmonster2
@tobsmonster2 2 ай бұрын
For low budget, get a Portable AC (dual hose if you can find one) and a Window Seal for the exhausts. Otherwise save up for a full Split Unit installation like in the video.
@aking9756
@aking9756 Ай бұрын
@@angetodacNo
@GoingGoneGalt
@GoingGoneGalt 6 ай бұрын
Two key points I would like to know; when was it done & how much did it cost???
@angetodac
@angetodac 2 ай бұрын
No answer
@weekendhomeprojects
@weekendhomeprojects Жыл бұрын
You're the King Leonidas of the mini split game. Instead of having 300 highly trained Spartans at your back, you have a shop vac and dewalt impact. F'in Legend.
@rickybungalow8839
@rickybungalow8839 2 ай бұрын
pulling a vac without a micron gauge is like weighing yourself with a semi truck scale
@FireBarrels
@FireBarrels 2 ай бұрын
Probably no valve core tool also
@dubmob151
@dubmob151 Ай бұрын
Does it allow a greater vacuum to be pulled or just tell you to leave it running for a longer time?
@rickybungalow8839
@rickybungalow8839 Ай бұрын
@@dubmob151 without a micron gauge you don’t know how good of a vacuum it is. So same amount of time but no confirmation if there’s a very subtle leak or pocket off air left
@guillermocuevas1306
@guillermocuevas1306 Ай бұрын
It helps you know when you have removed moisture and non condensables in your lineset and if you have any leaks ​@@dubmob151
@sagaapparel2055
@sagaapparel2055 Ай бұрын
Is there a longer version explaining steps and all those lines?
@CaltaTomas
@CaltaTomas 27 күн бұрын
No
@CrunchySnacks
@CrunchySnacks Ай бұрын
Thank you making this, because I've been trying to find one where you don't need anything from outside for apartments. This is even more invasive and wish products would advertise the installation more clearly. Thank you 😊
@mustangmike6421
@mustangmike6421 10 ай бұрын
That round plastic that you put behind the unit goes out side
@hug00l
@hug00l 4 ай бұрын
Same thing I was going to say, it's useless to have it there 😂
@GabrielGarcia-wq2wn
@GabrielGarcia-wq2wn 3 ай бұрын
Lo puso en el lugar incorrecto 😅
@joshuacarter7119
@joshuacarter7119 2 ай бұрын
No it doesn’t according to the manufacturer
@mustangmike6421
@mustangmike6421 2 ай бұрын
@@joshuacarter7119 it's to cover the hole you cut outside because the unit covers the hole on the inside!
@joshuacarter7119
@joshuacarter7119 2 ай бұрын
You should call the manufacturer and tell them that because it clearly says it goes on the inside in the instructions. Just installed one today.
@user-no7kx1tc3z
@user-no7kx1tc3z 6 ай бұрын
No torque wrench on minisplit flares= callback
@gerardo9052
@gerardo9052 2 ай бұрын
Why?
@SecretSauceyjuice
@SecretSauceyjuice 2 ай бұрын
​@@gerardo9052 leaks probably. Over/under tightening can be make or break in certain compression fitting applications.
@gerardo9052
@gerardo9052 2 ай бұрын
@@SecretSauceyjuice oh thanks
@nandinho8061
@nandinho8061 Ай бұрын
I've installed countless mini splits before and never used a torque wrench. Never had a call back on any of them
@jameslyon8602
@jameslyon8602 Ай бұрын
The real test is in a pressure test. That will tell you if you have leaks. And then a micron gauge on your vacuum
@jakkirhussain1819
@jakkirhussain1819 4 ай бұрын
VERY VERY GOOD WRECK 👍🏼
@phreshxmetal
@phreshxmetal 4 ай бұрын
Wreck?
@e92slate
@e92slate Ай бұрын
For my mini split installs I use sealant on the threads not sure if I saw you do it but it’s just a personal preference
@GoldDiamond-qr8qf
@GoldDiamond-qr8qf 11 ай бұрын
The gas lines connection joint should be inside the house, hidden behind the indoor unit.
@demented392rt5
@demented392rt5 11 ай бұрын
There's a connection on both, the evaporator and condenser. Just make sure to pressure test to ensure no leaks before you pull a vacuum
@GoldDiamond-qr8qf
@GoldDiamond-qr8qf 11 ай бұрын
@@demented392rt5 true, but the connection at the evaporator end should be inside the house, correct? Otherwise it would be very difficult to remove the indoor unit later for cleaning.
@jonsmith9708
@jonsmith9708 10 ай бұрын
Wtf you talking about gas? No gas all electric
@KhanhNguyen-jn4pt
@KhanhNguyen-jn4pt 5 ай бұрын
​@jonsmith9708 We called it freon in America, but other countries call it gas. Pretty much anything under pressure, they call it gas.
@mikecockerman2200
@mikecockerman2200 2 ай бұрын
​ No, I think it's better to have the flares outside. Torquing flares, remaking a flare if needed, are much easier when they are ouside, not under a minisplit head you have to prop up and limit your access space. Also, if your insulation around the flares isn't perfect, you may get water leaks from condensation.
@user-byjyi829wpqmsn
@user-byjyi829wpqmsn 2 ай бұрын
the plastic decoration goes on the outside of the hole where it is filled with sealing rubber to prevent insects from entering the air conditioner through the wall.
@eduardouru1
@eduardouru1 2 ай бұрын
😂😂😂😂😂me parto tienes que dejar la bomba de vacío por lo menos 1/2 hora para verificar que no haya ninguna mínima fuga campeón, y la instalación eléctrica que pasa se te olvidó o es que va a pilas😂😂😂😂😂fantasmaaaa👻👻👻
@aliciatreat-courtemanche5971
@aliciatreat-courtemanche5971 26 күн бұрын
I had mini split put in , and the units inside are at an angle. I have never seen any with an angle before when I asked they said for drainage. Now four months later it leaked all in the room
@DeeHandyman
@DeeHandyman 24 күн бұрын
I love your videos man, been watching since I started my handyman journey 5 years ago✅
@domaspapievis7907
@domaspapievis7907 Ай бұрын
Amazing! You showing how to not install AC in only 60 second! Well you could did it in 1 second, just showing how you drop out it and it would be fine to.
@juicemby667
@juicemby667 6 күн бұрын
❤❤❤❤ Good job ! Amazing
@IcannaHelp
@IcannaHelp Жыл бұрын
Do they not require a shut off or breaker outside?
@specops1903
@specops1903 10 ай бұрын
They will need a 220v hookup system yes
@dallasbd123
@dallasbd123 2 ай бұрын
Mine uses R32 , 20SEAR2 Rating ,110 volts and a MAX Amp draw of only 5 AMPS. 12,000 BTU. Plug it into wall plug inside.
@cappuccino-1721
@cappuccino-1721 9 сағат бұрын
Skeptics will say it’s sped up.
@eddiegomez3628
@eddiegomez3628 9 ай бұрын
Thats cute, I do it in 45 seconds.
@newpass9434211
@newpass9434211 10 ай бұрын
Crazy what they actually charge to install this..i got a quote of $1800 and they told me that was cheap!!! Am going to go DIY..
@dommm4235
@dommm4235 9 ай бұрын
1800 is cheap i just did one for 3200
@calvinm1866
@calvinm1866 4 ай бұрын
How it go doing it yourself?
@user-xv9dz9zp3s
@user-xv9dz9zp3s 4 ай бұрын
​@@calvinm1866😂
@user-xv9dz9zp3s
@user-xv9dz9zp3s 4 ай бұрын
​@@calvinm1866he didnt use a vacuum pump and just opened up the system. He didnt use a concrete pad and put it on the dirt 😂 Oh he also added R404 to top it off 🤦‍♂️ Very very very few can DIY. And that's people who know someone that help them do it lol
@joshuacarter7119
@joshuacarter7119 2 ай бұрын
@@dommm4235that’s unit and labor. Or just labor? If it’s just labor you are a legal thief.
@mccarterjg
@mccarterjg 14 күн бұрын
Okay that's what I thought crack the high side line first then the low side. I did not want to go through another 40 minutes tutorial from one of the other guys on that😂
@alwaysskeptical7221
@alwaysskeptical7221 Жыл бұрын
If only Europe knew this “hackery”
@Straight_White_Fatherly_Figure
@Straight_White_Fatherly_Figure Жыл бұрын
Pretty much lol well done brother
@Michael-qy1jz
@Michael-qy1jz Жыл бұрын
They make a system where you can run the lines from the condensing unit up through the soffits and then down to the room you want? Or just stuck with drilling oled through Cement? Lol
@samw6048
@samw6048 Жыл бұрын
Yea, I'm not fond of that idea. My house is block.
@robconcep644
@robconcep644 3 ай бұрын
Don't forget the nylog blue for the flared ends of the pipe.
@vj2411
@vj2411 Жыл бұрын
Not possible, he didn’t show you how to get the power to the unit . He didn’t show the shut off panel.
@davesaenz3732
@davesaenz3732 9 күн бұрын
Took me almost 12 minutes just to open the box. 5 minutes to fond the electric drill. Etc.
@jake.taylor
@jake.taylor Ай бұрын
Awesome! One question… Is the vacuum pump necessary on a new install before opening the valves and firing it up? I have installed mine all to way to this point 😬
@FC2ESWS
@FC2ESWS Жыл бұрын
How much would you charge for this install? Just wondering.
@VP411Designs
@VP411Designs 11 ай бұрын
$150
@joeburner7120
@joeburner7120 6 ай бұрын
@@VP411Designs$150 is the service fee to roll truck to driveway. $1200 for labor is fair if customer buys everything.
@VP411Designs
@VP411Designs 6 ай бұрын
@@joeburner7120 🤣 really? Help me Understand the labor costs breakdown! 6 seconds is more like 2 hours?
@user-xv9dz9zp3s
@user-xv9dz9zp3s 4 ай бұрын
​@@joeburner7120hes from the Dominican republic or Puerto Rico's where they do them for $150 😂 All seriousness they really charge that cheap over there. I'm Puerto Rican by the way 😂😂😂😂
@joeburner7120
@joeburner7120 4 ай бұрын
@@user-xv9dz9zp3s Yes, I was assuming it was in USA. I was born overseas in Montenegro. When I was there last, my cousin had one installed for about $400 for everything, including the equipment, material and labor.
@seya8890
@seya8890 5 күн бұрын
После такого монтажа... Копец!!!
@chado96k75
@chado96k75 2 ай бұрын
It comes with refrigeration inside the unit already?
@lmv1485
@lmv1485 2 ай бұрын
Yes they do. Mines needed to be measured and compressed to specs. But it does come with freon already
@chado96k75
@chado96k75 2 ай бұрын
@lmv1485 I don't need one I want one at the moment for my garage.
@MichaelPascoe-ru3rr
@MichaelPascoe-ru3rr 3 ай бұрын
These little ac are incredible. Just wish you didn’t need to drill a hole in the side of your home. For people renting a room or a house this ac would not work.
@Bleeperblopper497
@Bleeperblopper497 Ай бұрын
Rent a place with AC
@jomadjo1122
@jomadjo1122 Ай бұрын
The irreversible damage on the house is what gets me 🫨 to stay away and suffer in the heat
@donovanwallace1449
@donovanwallace1449 28 күн бұрын
Why portable acs still have a market, split units require drilling holes and it's confined to one room
@regularguy1140
@regularguy1140 7 ай бұрын
That vacuum thing was ridiculous
@foreverNwonder
@foreverNwonder 6 ай бұрын
Whaaaa I was coming to say that’s such a good idea!!!
@Tech-Tacked
@Tech-Tacked 4 ай бұрын
Atleast he installed it correctly
@user-ek3ok6sn8m
@user-ek3ok6sn8m 17 күн бұрын
Какая длинна трассы получилось? Зачем под внутренним блоком белое кольцо?
@stefanogoldoni7245
@stefanogoldoni7245 8 күн бұрын
non va bene il foro a sinistra, e poi è consigliabile far almeno un riccio di 3 metri per far lavorare meglio il compressore, quando la distanza tra interno ed esterno è molto breve
@AISmartHomesFund
@AISmartHomesFund 5 ай бұрын
This is great for HVAC Technicians
@chadwickjones286
@chadwickjones286 3 ай бұрын
Did the electrical just hook itself up?
@SecretSauceyjuice
@SecretSauceyjuice 2 ай бұрын
The bracket outside also mounted itself.
@angetodac
@angetodac 2 ай бұрын
Outside unit will be stolen next day
@christopherkrueger4328
@christopherkrueger4328 Күн бұрын
Hmm. Didn't use a torque wrench on the flare fittings, no pressure test, no testing for leaks under vacuum. Hope your refrigerant lasts!!.
@TheHandyman1
@TheHandyman1 Күн бұрын
It has been 2 summers running full time. This is a youtube short. The full video is on my channel.
@raipe76
@raipe76 Ай бұрын
Omg, you really have a ”Paper Wall’s there… in Finland, drilling a wall is never so easy. we have much thicker materials
@gabooda2380
@gabooda2380 Жыл бұрын
You should put #asmr in the title and you would get a ton more views from people who get woodies over odd sounds.
@GoldDiamond-qr8qf
@GoldDiamond-qr8qf 11 ай бұрын
Evaporator pipe jpint ahould never be bent. High chances of leaking.
@mrthomas7511
@mrthomas7511 4 ай бұрын
I would love to have an air conditioned garage when I have to change the oil in my car
@cahayandilaia2082
@cahayandilaia2082 2 ай бұрын
Pekerja org luar sangat rapi, beda dgb dikonoha
@jamesm568
@jamesm568 Ай бұрын
Remember, if you do this yourself most AC technicians will not service it.
@TheHandyman1
@TheHandyman1 Ай бұрын
Completely false.
@calikingz9924
@calikingz9924 2 ай бұрын
Question what’s the air you let out my first time trying to install a mirage mini split never done one how hard is it cause you made it look easy haha
@angelrodriguez6427
@angelrodriguez6427 10 ай бұрын
where is the nitrogen to pressures and micron gauge for the vacuum,, ?🤦‍♂️🤦‍♂️ remember acid is form by the moisture in the system and acid will kill the compressor… thats why you need a micron gauge to properly check vacuum level…Is always better to contract a license hvac contractor that knows why we do certain practices and not just anyone who thinks can install a system.
@hank9663
@hank9663 Ай бұрын
And you did not show electrical, not surprised, haha
@trueforum378
@trueforum378 9 ай бұрын
Thanks budy for the video and comments! well done
@amitdighe1212
@amitdighe1212 2 ай бұрын
You need some help?? No i am just chilling out here
@naui2
@naui2 Жыл бұрын
Nevermind I watch the video LOL
@missfit4943
@missfit4943 Жыл бұрын
Awesome job!
@macaframa1477
@macaframa1477 4 күн бұрын
no nitro test? catch ya in a year for a flat system
@Jon-kg6hm
@Jon-kg6hm 5 ай бұрын
Thought we wouldn't notice the misaligned grommet?
@birhanearefe6081
@birhanearefe6081 3 ай бұрын
i like it
@jackgentner9243
@jackgentner9243 Ай бұрын
Wow 60 second does that include the half hour you have to check the vacuum
@RD_Channel24
@RD_Channel24 8 ай бұрын
As a HVAC student I can now install my own Ac Unit...
@doracano3068
@doracano3068 3 ай бұрын
I need a ac are you in San Jose ca
@RD_Channel24
@RD_Channel24 3 ай бұрын
@@doracano3068 I live in Florida wish I lived in California, no worries I’m planning to expand out soon…
@MrTwone79
@MrTwone79 Ай бұрын
No one ever shows how to hookup the electrical part of this installation
@rvanbeau2009
@rvanbeau2009 6 ай бұрын
Hello no safety glasses when drilling through brick? Bad idea!
@teamdada2194
@teamdada2194 5 ай бұрын
You used a shop vac for a few holes haha
@danialphaomega
@danialphaomega Ай бұрын
What drill bit did you use? Thanks for any help
@vegetam5387
@vegetam5387 Ай бұрын
Para un hoyo de minisplit se usa de 2 ¼
@hectorgarcia8691
@hectorgarcia8691 2 ай бұрын
Good demonstration 👍
@voffka9574
@voffka9574 Ай бұрын
Вот интересно... Зачем кольцо для декора наружнего отверстия поставили изнутри? 😂
@CompareFN
@CompareFN 2 ай бұрын
You cut the hole to low. The wall sleeve is showing under the inside unit. Kinda crappy
@TheBmonster1
@TheBmonster1 8 күн бұрын
Why didnt you run the line set tighter to the wall anfnput some line hide up
@g-trixgtrix3110
@g-trixgtrix3110 11 ай бұрын
I love it.
@elstupido7323
@elstupido7323 2 ай бұрын
Only thing I noticed is why didn’t you put to hole a bit higher so that the pipes and cable could go straight through instead of having that ugly semi circle
@ekikereamos4456
@ekikereamos4456 10 ай бұрын
Nice one, I base on this
@peacehash2953
@peacehash2953 Жыл бұрын
How you did the leak tests
@vegetam5387
@vegetam5387 Ай бұрын
Se hacen un nitrógeno a la presión que indique el minisplit, después de una media hora a una hora si no baja la presión, está bien
@wadeghaney2781
@wadeghaney2781 6 ай бұрын
That pipe and electrical trouble you did was absolutely terrible
@PURGE-3000
@PURGE-3000 2 ай бұрын
Did the property manager allow that drilling ?
@fouadelreda1209
@fouadelreda1209 Ай бұрын
Who connected the electric to and how show us please
@AntiFakeJewsRev2-9-0Zach9-6
@AntiFakeJewsRev2-9-0Zach9-6 Ай бұрын
Shalawam & Thanks Bro
@naui2
@naui2 Жыл бұрын
I've been installing MrCool now for about a year. What brand is that?
@TheHandyman1
@TheHandyman1 Жыл бұрын
Tosot. only $770 for a 9000 btu unit.
@rucksackransack
@rucksackransack Жыл бұрын
@@TheHandyman1naui2 how does one install this in a 4th floor apartment in a 5 story building? How long can the lines go? (could i put the condenser on the roof above the fifth floor ceiling? Otherwise $$$$ scaffolding on side of bldg…)?
@dovco8565
@dovco8565 2 ай бұрын
no electrical connection? did I miss it
@mikebyrd8278
@mikebyrd8278 Ай бұрын
How well do they work for heating and air? Have heard mixed reviews
@Coen80
@Coen80 19 күн бұрын
Ah. Ok. Without a specific tool (the freon thingy) I can't do this myself I see... Effed.
@alexanderboyd2280
@alexanderboyd2280 2 ай бұрын
Damn so fuck the torque wrench huh😂😂
@fmills1583
@fmills1583 9 ай бұрын
How warm should the air be coming out of vent of electric a/c in winter time?
@Visionarygal77
@Visionarygal77 3 ай бұрын
Does anyone know how much it costs to replace a broken one of these head units? I apparently have a small leak in the head itself? I need to replace the whole head. But just one. Any thoughts?
@Daddychill..
@Daddychill.. 2 ай бұрын
Head ballpark price is 600 to 800, refrigerant depending on your area can vary from 80 to 150 a pound. Could be around 1600 with labor
@artsoto5459
@artsoto5459 8 ай бұрын
How much power does one of these mini split need? How many amp breaker?
@RiyaPal-rq6wz
@RiyaPal-rq6wz 10 ай бұрын
Good
@silvanolm9092
@silvanolm9092 26 күн бұрын
Just one question. Don't you plug it?
@samw6048
@samw6048 Жыл бұрын
What do you do to those holes in order to keep bugs out?
@namegoeshere1
@namegoeshere1 Жыл бұрын
Foam insulation
@michaelmcgee2026
@michaelmcgee2026 Жыл бұрын
You can use foam spray
@goalie2998
@goalie2998 5 ай бұрын
Why were your line sets so flexible?
@vlogwithshovan2653
@vlogwithshovan2653 8 күн бұрын
Which gas used in this AC ?
@alejandrofranco4385
@alejandrofranco4385 2 ай бұрын
The white pvc ring goes in the outside! Just saying
@danielcarrillo4385
@danielcarrillo4385 3 ай бұрын
What'd you use to drill the hole?
@alphaomega1351
@alphaomega1351 2 ай бұрын
It's called a drill. 😳
@JoshMrFire
@JoshMrFire 2 ай бұрын
concrete hole saw
@user-fx9eu6kd7b
@user-fx9eu6kd7b 2 ай бұрын
When u do a vacuum. Do u unplug the gouges to add refrigerant?
@vegetam5387
@vegetam5387 Ай бұрын
Si es nuevo el minisplit viene cargado.
@justclips6900
@justclips6900 2 ай бұрын
Is this considered HVAC or what’s this Job called?
DIY Mini Split Install - All the Things Nobody Shows You
33:25
COMO INSTALAR AIRE ACONDICIONADA, DETALLADA INSTALACIÓN MINISPLIT SISTEMA ,CLIMATIZADOR MONTAJE MURO
28:02
CARL EL PAISAJISTA - JARDINERIA, TRABAJANDO, KOI
Рет қаралды 6 МЛН
Советы на всё лето 4 @postworkllc
00:23
История одного вокалиста
Рет қаралды 5 МЛН
الذرة أنقذت حياتي🌽😱
00:27
Cool Tool SHORTS Arabic
Рет қаралды 11 МЛН
Please Help Barry Choose His Real Son
00:23
Garri Creative
Рет қаралды 21 МЛН
People Having A Bad Day | Funny Fails Compilation
19:59
FailArmy
Рет қаралды 4 МЛН
Multi-zone split type Air Conditioner installation
16:49
craftsman tv
Рет қаралды 374 М.
Midea 8,000 BTU U Smart Inverter Window AC Installation and Review
28:39
#1 Reason Why DUCTLESS Units Fail | How I Fix It...
13:59
Quality HVACR
Рет қаралды 808 М.
Como Instalar Minisplit sin Bomba de Vacío.
25:19
VikTools
Рет қаралды 943 М.
Della Mini Split AC Installation Step By Step 2024 | Total Installation
32:01
Steps to Vacuum and Charge Refrigerant on a Mini Split Unit!
15:08
AC Service Tech LLC
Рет қаралды 1,2 МЛН
LG Art Cool Mini Split Air Conditioner
2:16
Yermian_TheEnthusiast
Рет қаралды 35 М.
Советы на всё лето 4 @postworkllc
00:23
История одного вокалиста
Рет қаралды 5 МЛН