This wasn't safe....

  Рет қаралды 34,416

N Bundy Electrical

N Bundy Electrical

Күн бұрын

Get 10% off Rhino Trade Insurance using code BUNDY10 at www.rhinotradeinsurance.com/quote
Ansell gloves i wear www.youtube.co...
Use code BUNDY25 at unilite.co.uk/... for 25% off
Use code BUNDY10 at www.expertelec... for 10% discount
Join this channel to get access to perks:
/ @nbundyelectrical
This video is for entertainment purposes only and is in no way intended as a guide or 'how to'.

Пікірлер: 88
@bhm1712
@bhm1712 Жыл бұрын
The reason that the connection boxes don’t need to be metal yet is so that they can do another amendment and make more money selling the updated regs books etc.
@peterrimmer1325
@peterrimmer1325 Жыл бұрын
😊 11:10 😊😊😊😊😊😊😊😅😅😊😅😅😅😅😅😅
@edcooper2396
@edcooper2396 Жыл бұрын
The regs are going to get updated anyway
@daron8982
@daron8982 Жыл бұрын
yes and change the colour of the book
@jamesfurz7406
@jamesfurz7406 Жыл бұрын
Is this the one due before the one where they go back to a new fire rated plastic CU enclosure? 😂
@raychambers3646
@raychambers3646 Жыл бұрын
The reason they are plastic is to match the plastic trunking that will be banned in future regs book !
@AndrewLumsden
@AndrewLumsden Жыл бұрын
You should carry around your own LED corn bulb to replace any incandesant, so you don't burn yourself! Both BC and ES capped for all situations.
@ashleybignell2366
@ashleybignell2366 Жыл бұрын
its only switchgear containment that requires metal/non conbustible material. All our other junction boxes around the house are plastic, so 1 big one with multiple joints will be no different.
@hikariyouk
@hikariyouk Жыл бұрын
Using grey for live seems to be a thing with that style of connector; TE Connectivity use grey for their fused modular terminal blocks (I think one of the designs also comes in orange). Although the connector blocks do have brown available, along with blue, green/yellow, black, red, etc.
@TurboTimsWorld
@TurboTimsWorld Жыл бұрын
Wet Belt LOL Ive done a few, You do know Ford recommend changing the engine not the belt. There are 2 belts the "cam belt" and the "oil pump" belt make sure you have both done and the sealer takes 24hours to cure before the engine is run again, I have also had 1 transit die a week later and had to strip the engine down in front of a warranty engineer to find no reason what so ever for the engine to explode (the belt was still timed and intact). So this is a warning for Ford / Peugeot/ Citroen with wet belts those belts are supposed to be "life of the vehicle" but they are not have them changed 60k max. If you look though the oil filler hole that on some wet belt engines you can see the belt if its fluffy its to late. I know this comment is not electrical but you guys drive vans.
@AndyK.1
@AndyK.1 Жыл бұрын
They know. Hence why it’s being changed
@alexacb63
@alexacb63 Жыл бұрын
The bit that surprises me the most is that someone has done nice DIN rail terminations etc, but in an old CU. I could fully understand eg choc block or similar just rammed in, but to go to the extent of proper DIN terminals but with no sensible lid etc, is just mad...
@marcusstonham
@marcusstonham Жыл бұрын
Never heard the question asked about being a metal enclosure when using wago enclosures joining 2 cables together, it's the same principle as the relocation box. Regs say metal for switch gear only. That's why we don't use metal for all joint boxes. Would be a nightmare
@_chrisr_
@_chrisr_ Жыл бұрын
The regulations only require metal enclosures for switchgear so consumer unit has switches in but a joint box doesn’t so can be made of plastic. But yes I would agree that through movement etc joints can become loose and pose a fire risk, however is same is true for the majority for remainder of components installed too so there is an argument to alter regulations to require fire proof enclosures for all cable joints as well as requiring spring loaded terminals to be used.
@tunnel7
@tunnel7 Жыл бұрын
Why in this Country the fuse boards are mostly in very un-accessible place they can think of I do feel for UK sparks. Yes they should be metal boxes for sure.
@dimitar4y
@dimitar4y Жыл бұрын
agreed. nonsense locations every time.
@kobirelf97
@kobirelf97 Жыл бұрын
Most of the time because they're old buildings which were originally built to have electrical wiring in them say sometimes the easiest places in cupboards new builds have to have them in accessible place
@Ragnar8504
@Ragnar8504 Жыл бұрын
Are you allowed to leave single insulation in regular trunking in the UK? Over here that's only considered acceptable if the trunking can't be opened without using tools. I've had the occasional argument over that because sparks just love to hide choc blocks in trunking.
@robertburrows6612
@robertburrows6612 Жыл бұрын
How far do you go metal enclosers , wispa box are plastic , dryline boxes are plastic, surface mount boxes are plastic, plastic trucking and conduit are fire risk if that have accessories install in them particularly dado trucking . Are potential fire risk with arcing. We torq the terminal in a CU to prevent arcing, should be start torquing all terminals in sockets , switches ect. A side not does your work comply with fire regs, are you using plastic plugs with screw , metal screw conduct heat , the heat with melt the plastic plug causing what ever it fixing to collapse. It's down to the skill of the sparks . I rate you as a very skill full sparks, because your work attitude you always do the best job you can possibly do.
@AndyK.1
@AndyK.1 Жыл бұрын
So with your reasoning shower switches should be metal too?
@dimitar4y
@dimitar4y Жыл бұрын
if it's earth bonded correctly and there's a good RCBO/GFI then heck yeah.
@johnwarwick4105
@johnwarwick4105 Жыл бұрын
Yes completely agree a relocation box with that many circuits in has the potential to seriously overheat or catch fire they should be the same as consumer units and be metal or fireproof.
@Davidhughes9467
@Davidhughes9467 Жыл бұрын
Just seen the price on the wiska relocation kit 🙈
@dimitar4y
@dimitar4y Жыл бұрын
£70? free. Basically free.
@Davidhughes9467
@Davidhughes9467 Жыл бұрын
@@dimitar4y £80 odd in some place
@dimitar4y
@dimitar4y Жыл бұрын
@@Davidhughes9467 ye basically free.
@Davidhughes9467
@Davidhughes9467 Жыл бұрын
@@dimitar4y what?
@dimitar4y
@dimitar4y Жыл бұрын
@@Davidhughes9467 b a s i c a l l y f r e e
@SamMegadeth
@SamMegadeth Жыл бұрын
Perhaps the logic behind not requiring a joint box to be made of metal is due to loading on a common connection? A loose screw on a 100a main switch for example. Obviously the same amount if current is flowing through the junction box in total, but through each individual din rail joiner you'll only have 16a or 32a. I'm sure it'd still burn up a treat but that's my guess - and it is a guess!
@MartinCawley-xy1lo
@MartinCawley-xy1lo Жыл бұрын
Just asking to get your tools nicked from the truck.........worth checking with your tool insurance.
@dimitar4y
@dimitar4y Жыл бұрын
I want to see an overengineered wago relocation box. Deepest part has spring terminals, and then two separate screw terminals for the wire. With a visual indicator for overheating - some sort of color changing dye on the terminals to show they've ever gotten hot. If noone gonna make it, I'm gonna.
@Hoops-Senior
@Hoops-Senior Жыл бұрын
I like the idea of thermally sensitive colours. I build control cabinets etc. using quite a lot of DIN rail and that would be a really useful feature.
@dimitar4y
@dimitar4y Жыл бұрын
@@Hoops-Senior Might be easier to make it a separate product, just slap it across the cables with a big brush. Seeing as the wago installations are competent enough on their own.
@timc3600
@timc3600 Жыл бұрын
They already exist in all existing electrical products, this is not a new idea. When they get hot, they go a darker colour, with a smoky surround. A little bit of time after that, they start melting the surrounding plastic enclosure, then a little time after that, they catch fire to tell you that there is a problem.
@Makitafan
@Makitafan Жыл бұрын
I so prefer the Packout over seas vs the stateside offering. The black is such a smarter look than the all red. Which is quite ostentatious.
@marksmith-ew7ir
@marksmith-ew7ir Жыл бұрын
Great clean up on wiring,
@davidb3537
@davidb3537 Жыл бұрын
I have a Mitsubishi l200 truck with pull out draws, and I can confirm it ain't a van!! Can't wait to replace it!!
@moodyga40
@moodyga40 Жыл бұрын
no fire protection too
@pauljenkinson9277
@pauljenkinson9277 Жыл бұрын
Great run in review, I demoed a Z900 last week and found the throttle really snatchy, so may just be what you are use to. I also found the grips a bit small for my liking. Also for some reason made my hips ache, maybe just needed setting up better. Still love the bike though and you got the best colour.❤
@wonton8983
@wonton8983 Жыл бұрын
Have to be careful with DIN rail clip on terminals, they will fit upside down, which creates the possibility of 2 terminals side by side with no side insulation between them.
@littletyke76
@littletyke76 Жыл бұрын
I've done this
@danf6491
@danf6491 Жыл бұрын
And just to add the wago through box is self extinguishing in the event of a fire.
@danielelise7348
@danielelise7348 Жыл бұрын
See dinosaurs do exist. 3:00 😆
@Gaunty213
@Gaunty213 Жыл бұрын
It’s nothing more than a junction box and there not metal 👍
@carlrobson5745
@carlrobson5745 Жыл бұрын
Shame the previous spark did'nt use one of those relocation boxes or an adaptable box instead of the old consumer unit.
@gordonm2821
@gordonm2821 Жыл бұрын
Pick ups are usually for people who used to be hands on but now have a team. More a status thing
@jimmybadhan1429
@jimmybadhan1429 Жыл бұрын
Something to do with the insulation and terminals can handle certain amount of degress in regs somewhere. Also efixx got vid
@buildingsbyair
@buildingsbyair Жыл бұрын
i agree re: junction box. should be metal
@jameshansing5396
@jameshansing5396 Жыл бұрын
Thought bonding was supposed to be continuous? Plus surely, if the joint is in the trunking itself, that's not cool either?
@NBundyElectrical
@NBundyElectrical Жыл бұрын
To my knowledge it’s should be continuous, but in some circumstances, like this, running, a new cable would be pretty much impossible without destroying half the house, so by putting A through crimp on and making sure the reading is below 0.04 I would deem it acceptable 👍
@jameshansing5396
@jameshansing5396 Жыл бұрын
@@NBundyElectrical I have seen FAR worse Nicholas, sadly on a very regular basis for the current shower I am unfortunately working for :(
@leestorey18
@leestorey18 Жыл бұрын
I can't find a reg for this. It's just advice by the niceic I believe, it just has to be "permanently" connected.
@jameshansing5396
@jameshansing5396 Жыл бұрын
@@leestorey18 challenge accepted! 😂🤭
@leestorey18
@leestorey18 Жыл бұрын
@@jameshansing5396 you know what it's like with that book some regs just move when you're looking for them 🤡
@garylatto4191
@garylatto4191 Жыл бұрын
Whats the truck nick make etc , and what you think to it ? Looking at the ford ranger or vw amarok
@HA05GER
@HA05GER Жыл бұрын
It's a ranger and the new amarok is basically a ranger built in the ford factory just a couple of VW badges basically.
@sosurko
@sosurko Жыл бұрын
I’m sure speaking to the supplier it’s a fire resistant plastic that shouldn’t ignite.
@tommythomson99
@tommythomson99 Жыл бұрын
With the logic of having the extender box being metal couldn’t you not argue that every JB should be metal?
@PalladinPoker
@PalladinPoker Жыл бұрын
I would make it metal only above X total amps, so small or low power stuff can still be cheap and simple.
@Wawaw738
@Wawaw738 Жыл бұрын
How’s beard coming on?
@denbo786
@denbo786 Жыл бұрын
Tstak all the way😊
@michaelatkinson1378
@michaelatkinson1378 Жыл бұрын
Is that big troy on your T-shirt
@danf6491
@danf6491 Жыл бұрын
5 minutes in, instead of cutting the 10mm can you not just make a small Chanel out of plaster behind the back of the wago box and just run it around?
@smoggydrones5664
@smoggydrones5664 Жыл бұрын
Any box joining cable should be metal( perhaps not outside in gardens etc) to Aline with the 18th edition upgrade on fuse boards
@glynnmorris2667
@glynnmorris2667 Жыл бұрын
Which reg is that then?
@smoggydrones5664
@smoggydrones5664 Жыл бұрын
@@glynnmorris2667 I am saying it should be as any connection if not done right could be a problem.
@rob.1
@rob.1 Жыл бұрын
Ah, so it's fine to be plastic outside, but not inside? Cool.
@BenWiggins101
@BenWiggins101 Жыл бұрын
I fit plastic cu's all the time 😂
@O.i5
@O.i5 Жыл бұрын
The reason the relocation box doesn’t need to be metal in my opinion is because if anything comes loose, its only touching plastic since everything in the box is plastic unlike a fuseboard which is metal
@hks-lion
@hks-lion Жыл бұрын
I think the regs talk about metal if circuits are switched within otherwise plastic is fine. I believe metal CUs are supposed to reduce the spread of fire.
@user-wk7wv8rn8h
@user-wk7wv8rn8h Жыл бұрын
Won't contain a fire very well though
@carlhobson1578
@carlhobson1578 Жыл бұрын
Will spring terminals really stand the test of time?😊
@yngndrw.
@yngndrw. Жыл бұрын
I like to think of them as reusable crimps.
@JimWhitaker
@JimWhitaker Жыл бұрын
Yes, better than anything else, except perhaps a crimp made with proper tools (not hand operated) and matched connectors.
@alanwood9804
@alanwood9804 Жыл бұрын
This isn’t anything new…. Wago spring terminals have been used in industrial machine control cabinets for about 40 years.
@shomsw81
@shomsw81 Жыл бұрын
What happened to the new apprentice, I think it was Ben?
@jamiemurphy3404
@jamiemurphy3404 Жыл бұрын
Get rid of that wet belt
@annakissed3226
@annakissed3226 Жыл бұрын
You have close to 100k subs. Your NOT a small beer KZbinr. Ask Artisan who their Milawakee contact is. You should get your pack out boxes for free - just for the free advertising Milawakee get if you use their stuff.
@leeedwards9994
@leeedwards9994 Жыл бұрын
free tissue lol .....
@smoggydrones5664
@smoggydrones5664 Жыл бұрын
That’s why I DIY most tradesmen not on KZbin are crap
@rob.1
@rob.1 Жыл бұрын
Yes, only good tradespeople have KZbin channels.
@voltare2amstereo
@voltare2amstereo Жыл бұрын
Artisan for their pack out free.
@ElecromechanicalSam
@ElecromechanicalSam Жыл бұрын
What's the difference between your qualification and Adam's? Are you not equal?
@svdleer
@svdleer Жыл бұрын
Are you guys so long really :)
@troyboy4345
@troyboy4345 Жыл бұрын
Your Mum works out the back of a van .... 😇
@yngndrw.
@yngndrw. Жыл бұрын
I don't think your mum is that picky.
@troyboy4345
@troyboy4345 Жыл бұрын
@@yngndrw. not at her hourly rate
Builder Created a DEATH trap!
21:07
N Bundy Electrical
Рет қаралды 53 М.
No Plans + No Drawings, didn't end well...
14:00
N Bundy Electrical
Рет қаралды 30 М.
Edd China Reveals the Shocking Truth About EV Battery Repair
19:52
We Need Internet! Running a 3,000 ft Fiber Optic Cable
19:53
The Homesteading RD
Рет қаралды 416 М.
£10,000,000 London Apartment Electrics, Why is it so EXPENSIVE?  | ØY15
19:16
Cory Mac - ØY Electrical
Рет қаралды 161 М.
Cowboy or DIY disaster! Never seen anything like this
14:30
N Bundy Electrical
Рет қаралды 24 М.
I DON'T EVEN KNOW WHERE TO START! 😳
19:42
Artisan Electrics
Рет қаралды 76 М.
Why We Build Houses with Nails, Not Screws
17:05
Essential Craftsman
Рет қаралды 862 М.
Unseen Things - What Would You Do With All These?
22:40
N Bundy Electrical
Рет қаралды 17 М.
Quinetic lighting Rewire up, Exotic life of an Electrician
16:13
N Bundy Electrical
Рет қаралды 70 М.
Bi-Directional Fuseboard Install For Solar & Battery
23:21
N Bundy Electrical
Рет қаралды 23 М.
CHEAP Electrician cost this customer £1000s💷
18:43
Artisan Electrics
Рет қаралды 139 М.