❤Wishing you health and success, greetings from Vietnam
@MartinJohansson-nn5dvАй бұрын
Looking nice. The first things going bad on the roof is the wooden sides bec they are not painted ( you can install a 2x2 cut diagonal so you get a triangle shape wood. That you install at the short end UNDER the membran on the short side side of the roof and the water can not reach the panels on the side on the backside) and the more important is to install the wooden ribs where you screw the metall roof to. First you install a vertical rib and on top of that a horizontal where you screw your metal roof on. Now your condensation (or water from a leak) under the roof can ran off and not stop at the ribs you just install and it looks that you not using treated wooden ribs, you do not need that if you install it right. Now you gona have water to the ribs and they gona rott quicker.
@blakecurtis30682 ай бұрын
If you have to cut metal agin you can use a tile blade on your circular saw, or flip a saw blade backwards but then you will have 10,000 metal bees stinging you. The tile blade eliminates the metal bees. Also cut it from the bottom, it’s easier cutting the ribs that way
@MartinJohansson-nn5dvАй бұрын
Using a grinder or circular saw when cutting a metall roof destroy the metal bec it is to hot and start to rust. It is a reason why there are a nibbler tool or scissors for metall.