Hi Tim, I am a Controls Engineer for a facility and I have really enjoyed your videos, much appreciate the content. I find a lot of manufacturing equipment still with legacy plc’s/hmi etc. would you ever consider doing a video on a conversion of SLC500 or even plc 5 to studio5000 compactlogix/controllogix? I also find that we have to know more and more about networking between the IT and OT environment. Would love to see that as well! Thanks again love the videos !!!
@TimWilborne3 жыл бұрын
Hi John. I have one coming on converting a RsLogix 500 program to a Studio 5000 program, I probably won't do anything on IT to OT but we are going to do some limited best security practices when designing control systems. Thanks for watching!
@freetoomaj129012 күн бұрын
@@TimWilborne thank you so much for your response 🙏
@anglebertmasunda61323 жыл бұрын
Thank you so much Tim, you make the best and easiest to understand automation videos...
@TimWilborne3 жыл бұрын
You're very welcome!
@seyedmohamed22414 жыл бұрын
Nice explanation. Please do video on Allen Bradley plc with foundation fieldbus devices.
@TimWilborne4 жыл бұрын
I don't have the hardware for that. Let me see what I can find.
@michaelcostello6991 Жыл бұрын
Thanks. great effort here.
@TimWilborne Жыл бұрын
You're welcome!
@edelinhernandez13292 жыл бұрын
hello! Sorry for the inconvenience but I have tried connecting an I8EC expansion module but I have no reading of my signal. the module as such does not have a common. Might you help me? Greetings from Mexico
@freetoomaj129013 күн бұрын
Hi Tim, I have a 1769-L19ER-BB1B Series A PLC, and I’m looking to add analog input and output modules directly beside it. I wanted to ask if I need to use specific modules compatible with this PLC model, or if there are any limitations on the module types for this series. Thank you
@TimWilborne13 күн бұрын
You would need to use the 1734 Point IO modules for that then you need to determine if you need a current or a voltage input.
@bharathkumar-ju1jy3 жыл бұрын
Nice explanation sir . And my doubt is how to add more expansion modules in a CPU which only supports 4 modules
@TimWilborne3 жыл бұрын
You could use a 1734-AENT to add more point I/O.
@bharathkumar-ju1jy3 жыл бұрын
@@TimWilborne thanks a lot sir.. pls make a video about it..i am eagerly waiting for
@automotivate.vamshi15492 жыл бұрын
Nice video.. Thanks alot for making..
@TimWilborne2 жыл бұрын
You are welcome!
@blessdstry4 жыл бұрын
I would love to see a video about vocabulary, naming ideas and Programing structure.
@TimWilborne4 жыл бұрын
Hi Tyler. That is a tough one. I don't like to do videos that put "rules" in place that people may not understand why they are using. Can you give some more details on what you are thinking?
@soemin48472 ай бұрын
Thank you
@TimWilborne2 ай бұрын
You're welcome
@Levon94044 жыл бұрын
Tim can I buy Allan Bradley trainer from you and how much will cost me, if I buy from you.
@TimWilborne4 жыл бұрын
You sure can. See link below. www.theautomationstore.com/plc-trainers/
@TimWilborne4 жыл бұрын
@Holodomor American Style Glad you found them helpful plus kudos for passing them on to the next generation.