So strange seeing that flue there. Its troubling my eyes especially without the terminal guard. This is a good video Allen. Nice to have a visual aid. Please keep posting commercial videos too. You've been posting for 10 years and you can tell in the quality of the vids. Keep posting more and as regular as possible. It's improving industry standards.
@lizardboy08023 жыл бұрын
hay there. I've sent Allen loads of vids but as I said to him the other day its his channel so its up to him and no rush. its not Allan's fault. some of mine are long winded and need editing, which takes time. He's doing some good stuff with the kids and I would really love to get some of them kids on my sites. put them in the deep end. its how I learned. As you know we are like Unicorn shit, Plus I'm a oddball and have LV 1 and 2 C&G in electrics. I'm sure you are the same. I will keep on sending videos.
@AllenHart9993 жыл бұрын
Thank You.
@joncole23733 жыл бұрын
I was taught in training to fully open the ecv at the end of the test to standing pressure to ensure regulator had not lock up during the test. Good vid keep them coming 👍🏻
@AllenHart9993 жыл бұрын
I have never heard of that before but that’s a great idea. Thanks for sharing.
@boby1152 жыл бұрын
@@AllenHart999 ,Jon is absolutely correct ( if the regulator is locked up that means you would have back pressure feeding your leak, if one is present ,making your tightness test void, inaccurate at best). Jon , thank you for your comment👍.
@macpatel78103 жыл бұрын
Very good lads. Nicely done. Clear and concise explanation.
@AllenHart9993 жыл бұрын
Thank You
@KS-we8ov3 жыл бұрын
Excellent effort...Big up to Allen
@AllenHart9993 жыл бұрын
Thank you.
@mathman01013 жыл бұрын
I would also put a clamp meter around the earth conductor on the gas main to ensure there is no earth current or diverted leakage on that CPC. That would be in addition to using your voltage meter - I would think a proper voltage meter and proving unit is better than a NCV stick.
@georgerobinson5762 жыл бұрын
well done nice and confident and a steady hand to raise pressure to 20mbr first try . good vid Allen thanks again
@AllenHart9992 жыл бұрын
Thanks 👍
@paulbmoody3 жыл бұрын
That flue needs a basket allen 🤣 unless youve grown
@AllenHart9993 жыл бұрын
😂😂😂😂
@chieflee8775 Жыл бұрын
amazing video. WELL DONE ALI AND THANKS ALLAN
@themorgans13283 жыл бұрын
Great video, well done Allen 👍
@AllenHart9993 жыл бұрын
Thank You
@salamatali643 жыл бұрын
I'm newly qualified gas engineer, I'm in London I would love to go on jobs with Allen to gain experience. There's so much too learn from a proper gas engineer who don't cut corners. Shame he don't live near by. If you are in London ever give me a shout.
@AllenHart9993 жыл бұрын
Thank you so much for your kind words.
@MussoliniLondon4 ай бұрын
I'm newly qualified, it's been 3yrs, how did it go
@ShaunOllerton3 жыл бұрын
And also make sure your contractor who replaces your boiler and the copper pipe doesn't drip flux on the Flexi pipe. Found out this week that it had corroded the flexi pipe and leaking gas. The work was done last July
@AllenHart9993 жыл бұрын
Thanks for the comment.
@user-hl4hx2nd4h3 жыл бұрын
Covered everything needed there, good on ya kidda. TT in, TT out. Gone way more than most there. Bird cage on that flue though (which I'm sure there is) 😂
@phoneblaster Жыл бұрын
...ello Allen, I can honestly say that was a great video, clearly you have trained 'Alley' to a good standard and I think he did you proud there. I am not sure that was the 'first roll' or 101 , but good delivery. Any reason why you guys dont use 'highly' colored manometer fluid ? It would have beeen good if Alley did the manometer setup, putting fluid in it, etc .never mind eh.
@AllenHart999 Жыл бұрын
Thank You
@martinmcintosh45582 жыл бұрын
Well done Alan, keep up the good work 👍🏽
@AllenHart9992 жыл бұрын
Thanks, will do!
@yadavplumber6423 жыл бұрын
I love plumbing work details
@splodders3 жыл бұрын
The allowable 4mb drop over 2 mins is with the proviso that appliances are connected and there is NO smell of gas.
@AllenHart9993 жыл бұрын
100% Correct. Thanks.
@daytripper71703 жыл бұрын
Need also to visually check for corrosion of the gas meter itself, and any holes at the back of meter box going into the wall of the property
@AllenHart9993 жыл бұрын
Thank you for the feedback.
@Kavi-tk4zl2 жыл бұрын
Hello Allen, thanks for your video, now I am doing my gas safe engineering course and I need a gas safe engineer for my portfolio, so could you please guide me?
@mitz27723 жыл бұрын
Great video
@AllenHart9993 жыл бұрын
Thank You
@christopherjordan48123 жыл бұрын
The electrical earth bonding has one of the conductors wrapped round the end of the insulation. All the conductors must terminate on the earth clamp. This happens all the time as earth cables have an odd number of conductors. If this practice is carried out it reduces the size of the earth conductor (CPC)
@madmaycon25312 жыл бұрын
Very Good thanks !!!!! thank you so much for sharing this video with us .
@AllenHart9992 жыл бұрын
Thank You
@332marian Жыл бұрын
I always give a quick spray of leak detector on the gas tap.
@andreusredloff22525 сағат бұрын
Thanks mate . Clear as.
@vishalchain Жыл бұрын
hi alan thanks for video.. i am new student too. when i do u guage other side doesnt come same even when i adjust them to same.. is that normal or do i need any adjustment to get same on both side please thanks in advance 😊
@AllenHart999 Жыл бұрын
Yes, add them both together and divide by 2. Thanks.
@adukiewright8597Ай бұрын
Where is the training centre located ?
@masterhtmn38453 жыл бұрын
Thanks for this video Allen 😀
@AllenHart9993 жыл бұрын
Thank You
@Limitlessboilers3 жыл бұрын
Very good well done, nice job. Terminal guard missing on flue lol
@AllenHart9993 жыл бұрын
Thank You
@drippy70932 жыл бұрын
For the Tightening test do you leave the U gauge on 20-21 like the Temperature stabilization test?
@davidpotts177810 ай бұрын
Yes but for a further 2 minutes
@jdheaphy12 жыл бұрын
Great video Allen. I thought I recognised you from Tik Tok and your pv panels and batteries
@BlGB0SS3 жыл бұрын
Excellent video Allen, what did he do to get the pressure from 10 to 20 for the second test?
@F4r4z_xD3 жыл бұрын
Exactly
@colin50643 жыл бұрын
he obviously opened the gas valve more via the handle
@abdulaziz-pb5ni Жыл бұрын
Hi Allen hart is the trainee now gas safe engineer
@ShetuhamOilandGasLimited-ht3gu8 ай бұрын
In Nigeria, we use gas cylinder and lpg gas for gas tightness test will it be the same process as the natural gas
@keithbrueton3 жыл бұрын
Another top job there 4mb drop with no smell of gas ?
@AllenHart9993 жыл бұрын
Absolutely. Thanks.
@ShetuhamOilandGasLimited-ht3gu8 ай бұрын
Hello, Allen. I tried to join by making a payment buy but could not because I am in Nigeria and I did my gas engineering training. Let me know how can donate using other means
@jezlucas3878 Жыл бұрын
Hi ya , are smart meters considered same as ultrasonic e6 meters in terms of permissable drop of 8bmr
@E69apeTheMatrix4203 жыл бұрын
How do you change the gas meter outside box if its damaged? I bought a nice new one but my plumber wont fit it for me because of the lower left nut
@AllenHart9993 жыл бұрын
Good question. You need to call out the gas transporter i believe.
@E69apeTheMatrix4203 жыл бұрын
@@AllenHart999 Thanks. I called them already. They said they charge £120 but includes a box. Because I already bought one now its a bit annoying. still waiting to hear back from them after sending pictures and everything over in email. Hopefully they can fit my Mitras MK2 box because it looks really good. (for a gas box!) Hahah.
@memyselfandi36 Жыл бұрын
@@E69apeTheMatrix420 swap it yourself its piss easy ..if its like for like then it's a straight swap
@E69apeTheMatrix420 Жыл бұрын
@memyselfandi36 The mains gas in on. The nut is before the valve. There will be gas bellowing out whilst I change it over. Not very well explained my end but the pipe that goes into the bottom of the box has a valve inside the box. Therefore to unscrew the valve to get the box off means gas everywhere.
@E69apeTheMatrix420 Жыл бұрын
@@memyselfandi36 I have a proper enclosed box replacement. Not just some backless cover to place over everything.
@daibhiseaghdha1532 жыл бұрын
is it worth mentioning that the gas hob / gas oven / boiler etc, should be not be in use,, when you are doing the tests, I know that it is only " common sense " but not every body has " common sense " it's good that a good person, is educating us, unlike some people on youtube who are sending us down the wrong road, because they do not know what they are talking about, which is bad.for every one.
@lizardboy08023 жыл бұрын
Hay folks. Me personally use electronic. It cuts down time (commercial) And doesn't blow out your water on medium or high pressure systems (don't expect you folks to be working on high pressure). Honestly? electronic is how it should be. You print it off and prove your work. Its all about CYA these days, cover your arse. Don't get me wrong I keep a water one on my van but, I have two monometers and my FGA that also does a tightness test. Cant be to careful these days. I'm a big believer in PROVE YOUR WORK. CYA. Love ya all.
@AllenHart9993 жыл бұрын
We have a new video coming soon using a Kane. Thanks.
@arcturus4753 жыл бұрын
Quality video
@AllenHart9993 жыл бұрын
Thank You
@neilbirkett8352 жыл бұрын
Cant seem to find the video, but where was the bleed off valve from,for the manometer thanks.
@tahirmahmood6316 Жыл бұрын
Well done lads x
@paul13efc3 жыл бұрын
Allen what does the maximum allowable drop equate to in volume of gas lost over a year.
@veronicahart4503 жыл бұрын
Very good video
@AllenHart9993 жыл бұрын
Thank You
@MrFoyezmiah2 жыл бұрын
alen you haven't mentioned anything about turning the pilot off any gas fires or opening the cooker glass lid when you are doing a tightness test
@MrFoyezmiah2 жыл бұрын
Nice video though 👌
@SobanKhan083 жыл бұрын
Good job
@AllenHart9993 жыл бұрын
Thank You.
@richardsheppard58813 жыл бұрын
Make sure sheerbolts are in tact
@AllenHart9993 жыл бұрын
Thanks.
@ashiahafeez21066 ай бұрын
Really helpful!!
@ireneuszgargala24010 ай бұрын
Hello. Could you let me know how can I fill up this manometer with fluid? Thank you
@davidpotts177810 ай бұрын
Take one if rubber tube ends off and fill with cold water until its around zero mark. Then lever the ugauge and slide it to zero on both sides
@sidmuzik93973 жыл бұрын
Great video as usual! I am wanting to complete a gas training course to ultimately be Gas Safe, I am currently doing my level 1 plumbing at college, do you have any advice? Thank you
@petersutton5873 жыл бұрын
Don’t bother mate to many gas people the market is flooded with gas engineers
@sidmuzik93973 жыл бұрын
@@petersutton587 that's because its a huge demand. Which makes it a perfect career choice.
@petersutton5873 жыл бұрын
@@sidmuzik9397 that’s what the training centre want you to believe to take your money
@sidmuzik93973 жыл бұрын
@@petersutton587 the majority of gas engineers are in there 50s, which means that they will be retiring in the near future, which also means there will be an even bigger demand for gas engineers 🙂
@petersutton5873 жыл бұрын
@@sidmuzik9397 ok mate you know best you will find out the hard way when you can’t find work and if you do the money’s crap
@gb1vibeio332 жыл бұрын
after applying the the gas leak detector do you have to wipe the solution do to cursive effect ?
@davidpotts177810 ай бұрын
Cursive?
@memyselfandi36 Жыл бұрын
If you turn gas valve off unscrew inlet and outlet nuts and take meter out and replace with your own and tighten nuts back up amd turn gas back on then there should be no problems as it's like for like ..test for leak with a squirty bottle with soap in ...if it don't bubble then jobs a goodn
@vipergas55423 жыл бұрын
👍📖👌 Great Video
@MohammedRafiq-gl3tw5 ай бұрын
What happened to safe safe to touch test
@mcbreartyfull11 ай бұрын
That flue outlet to left of your man should have cage cover !?
@AllenHart99911 ай бұрын
Thanks.
@emeekhan2 жыл бұрын
Awesome
@fastusbombastus20853 жыл бұрын
Allen, could you please, indicate this piece of law which says that the only qualified person can carry out work on gas installations?
@AllenHart9993 жыл бұрын
You need to be gas safe registered in the UK or competent,
@fastusbombastus20853 жыл бұрын
there is difference between need and must...my question is still not answered...maybe in the next video say a few words about it....up to my knowledge there is no piece of LAW which obligate to be gas safe registered to carry out work on a gas installation...they say "competent"... Is it illegal to install a gas cooker yourself? from Mr. Google... There is no law to say you cannot do a gas installation yourself providing (under the law) you are competent. ... Also stated is that you (the homeowner) should not carry out any work that results in the disturbance of a gas carrying or supply component e.g. a gas supply pipe.
@fastusbombastus20853 жыл бұрын
@@AllenHart999 Is it illegal to work on your own gas boiler? It's not technically illegal to carry out DIY gas work in your own home* as long as you are 'competent' to do so, but the consequences of doing so without the necessary skills are hugely dangerous. Working with gas is a complex and dangerous task that requires extensive training, knowledge and experience.
@eatdahl3 ай бұрын
Why is tightness test done at 20-21mb
@yadavplumber6423 жыл бұрын
Nice bhai
@AllenHart9993 жыл бұрын
Thank You
@johnflower86483 жыл бұрын
The isolating valve should have been installed so that door could be closed with valve in isolated position.
@AllenHart9993 жыл бұрын
The Valve turns both ways. Thanks
@davemorgan27982 жыл бұрын
As a ret'd Gas Engineer , 1 wee omission, 4mbar escape is allowed ONLY IF NO SMELL OF GAS REPORTED !!! Any report of a smell of gas, no matter how small a leak, must be found !!
@chieflee8775 Жыл бұрын
bore off
@newcastleboilermaintenance49564 ай бұрын
Guards should be fitted over all flue terminals less than 2m above ground level?!!!
@GORAPAKORA2411 ай бұрын
top man x2
@AllenHart99911 ай бұрын
Thank You
@kirksalter2 жыл бұрын
Not too bad however you haven't tested the installation for electrical isolation you touched it about 10 times before mentioning the earth bonding ,simple electrical checks will save your life
@jamesmackie66413 жыл бұрын
On a hot day I smell gas at the side of my house but couldn't tell where its coming from
@ImranKhan-hz8jy Жыл бұрын
Should not be compression fittings on meter outlet
@zebakhtar40222 жыл бұрын
4 mb drop allowed providing no smell of gas
@wildracoon6663 жыл бұрын
I thought he would ask u for a £10 with u being a Yorkshire man as a tightness test😉
@AllenHart9993 жыл бұрын
😂😂😂😂
@mickbmx2 жыл бұрын
You shouldn’t be telling the general public how to work on gas. Prat.
@jamesjross9 ай бұрын
"Smell Gas or aught like that" You got yourself a proper Yorkshire lad there.