May your soul rest in peace.... Best ETO of all times
@LarrydWoodruff4 жыл бұрын
This video is a good reminder on how to handle E109. Very nice!
@leckyjake4 жыл бұрын
Thank you.
@jeanermac15073 жыл бұрын
Thank you for blog sir jake. Marami akong natutunan sayong vedio. Elect then ako sa passenger ship.
@kpreroualbertkezo26233 жыл бұрын
Good morning sir thank so much for this video . So we need more video concerning daikin containers .
@stephenwoolway74953 жыл бұрын
Jake - outstanding work. I’m a docking superintendent for Svitzer Australia 😉
@leckyjake3 жыл бұрын
Thank you. Been wanting to work in Australia as Reefer Tech ever since
@janettelanuiki2 жыл бұрын
Thank you for rectifying that -10.1 temp (It was killing me) Nicely done
@senthilanbalagan85324 жыл бұрын
Good job bro mostly I done blowing hot air on that eev part till now for clearing and tap sometimes but this helps a lot that I can clean the valve part hereafter thanks a lot bro
@gautham24184 жыл бұрын
Thank you so much lecky. Wish to sail with you someday.
@leckyjake4 жыл бұрын
Thank you for the support
@yevhenstelmakh45964 жыл бұрын
we had same problem with daikin unit, but cleaning of eev dont help, we use manual eev from reefer kit. thank you for videos!!!
@leckyjake4 жыл бұрын
The EEV body is the problem then
@pradeepprakasan4 жыл бұрын
thank you sir.as a trainee ee it really helped me ❤️
@leckyjake4 жыл бұрын
Just keep on sharing the channel so that we can help more aspiring ETOs
@pradeepprakasan4 жыл бұрын
sure sir.i will share with my friends
@brahim212612 жыл бұрын
Hello jack thank you for al the video's. I have a j081 alarm on my daikin. Pumpdown alarm. Where i have to look first? Thank you 🙏
@salemhunid94824 жыл бұрын
thank you very much sir. keep doing videos about troubleshooting of reefer container
@leckyjake4 жыл бұрын
I will and expect more. Videos will be uploaded every weekends
@salemhunid94824 жыл бұрын
@@leckyjake Thats will be great bro. good luck
@domalexus19912 жыл бұрын
Thank you very much sir! I just now encountered this alarm, good thing i saw your video just before i was about to replace the filter drier. Thank you very much! :)
@antoniolim24422 жыл бұрын
good job sir and thanks for sharing on your experience so we can spread out and more knowledge to be apply .
@khaledmaher6981 Жыл бұрын
Thanks for the great video, What type of Loctite you do use ??
@robertemanuel25903 жыл бұрын
If the problem had been a blocked filter drier instead of the EEV could you have replaced the filter drier on board ship ? Thank you Lecky I really enjoyed your videos.
@leckyjake3 жыл бұрын
Yes it is the main goal onboard, to save the cargo. Filter drier is fixable onboard
@robertemanuel25903 жыл бұрын
@@leckyjake thank you. It is funny how a P&I Club correspondent is arguing with me that you can not do it !
@Yourservice9 ай бұрын
Mr.Leckyjake is there other cause of alarm E109? other than the EEV COIL?
@cyrildelacruzjr43653 жыл бұрын
Happy morning sir keep safe 🙏 god BLESs 🙏
@ethanlove55133 жыл бұрын
Excellent video very helpful and informative
@senly41473 жыл бұрын
sir you know everyday ii try to fine your new video for cantainer freezer because you have experience for that
@leckyjake3 жыл бұрын
How is your unit? I hope you already fix it
@Irvindzimlaz2 жыл бұрын
@leckyjake do you think its possible to run these containers all day on Solar. Say a 20ft size?
@marvindiazdeleon19932 жыл бұрын
They used silicone as the service bulletin of daikin wants to seal the eev body and keep from moisture entering, but its look like it can't help as it is still clogged by the dirt and falls to E109.
@DiegoPerez-ms3yu2 жыл бұрын
VERY GOOD VIDEO, DO YOU HAVE OTHERS BRANDS TROUBLESHOOTING CASES?
@Gokolito846 ай бұрын
Hello there, do you have any idea is zestia and regular daikin reefer have same condenser coil? I need to replace a condenser coil on zestia reefer but i have 2046165, not zestia's 2233495. Thanks.
@fatihdanfatimah18383 жыл бұрын
You are the best, Sir. Thank you
@henrylitton39413 жыл бұрын
What is the refrigerant use and what is the correct pressure for low and high pressure iwant to learn in reefer van thanks
@TuanMinh-zd4trАй бұрын
hope you still read this comment. looking forward to your help. my device is having error F803 and E107.
@nunzio99lombardo56 Жыл бұрын
Hi Leckyjake, in my case I have an opposite situation, LPT does not move in any case, it always stays at 300 I also tried to close the EEV with the emergency cap but nothing to do. Any idea how I can fix it
@adamy61164 жыл бұрын
sir, what is the normal reading for hpt and lpt for -18 to -21'c..
@reohsamjale61164 жыл бұрын
Swerte nman ng maging cadete mo sir,thank you for sharing leckyjake
@courtrutherford89133 жыл бұрын
You should try using Nylog on the EEV threads. It's like pipe dope for refrigeration.
@vijayakrishnankogulan77382 жыл бұрын
May i known what is the normal value of hot,lpt???
@lusaneswisse98102 жыл бұрын
Hello sir i will thank uu so much for sharing ur videos ..and ur experience its helping us so much ...just i want some help i hade probleme whith same reffer is giving alarm p0000 after some.time i check that is giving changing up to p0006 but still alarm is here and reffer not started any help plzz
@ferdirahim67946 күн бұрын
Full skill
@rasssike59413 жыл бұрын
wow sir aspiring seaman here sana sir matulingan niyo ako pano po ba mag appy sa ganyan
@cesdawa79383 жыл бұрын
Hey we have an issue with our container.After a massive thunder storm,the fan inside is running but it seems the compressor and fan is not coming on?What do you think the problem is?Do you think a power surge may have caused a particular part to blow up such as a capacitor?Need your advise for our technicians to engage a reefer mechanic to have a look and fix
@laljayasundara73712 жыл бұрын
thank you and God Bless.
@aungkowinkyi85492 жыл бұрын
Tks you very much indeed.
@weatherdonemulenga97113 жыл бұрын
I am working on Daikin LXE10E-A33A , giving me the Alarm code F101. Upon disconnecting the compressor outlet, the compressor started running ok and the alarm message disappeared.we come to conclude that the compressor is not ok and especially it is becoming very hot on it's upper area. I need your view on this one.
@leckyjake3 жыл бұрын
F101 activates when your High Pressure Switch activated. You have to check your discharge pressure first and analyze what is causing the pressure to get high.
@weatherdonemulenga97113 жыл бұрын
@@leckyjake Thanks very much to respond. I 'll check as you have said. I am in Zambia . I would love if we can arrange and communicate on video call. I admire your expertise
@bikermotards79563 жыл бұрын
Hi, tank you for this class! Can you help me, I need to buy some refees world wide and I need Honest suplyers. Can you mention some. Please
@muhammadrasheed38483 жыл бұрын
good video my friend
@janettelanuiki2 жыл бұрын
Nice! My husband used to work for Seattle CEM shop(I saw the sticker on the condenser cover) well explained. Are you Pinay?
@luisedward33363 жыл бұрын
Hey mate need some help.Was getting a E205 alarm on a daikin freezer container ( evaporator fan motor failure)Changed one of the evaporator fan motor because it had a bearing issue. After hours of operation the same alarm still appears. I’ve checked the running amperage of both motors and they appear to be fine. Is there something I’m missing?
@leckyjake3 жыл бұрын
there might be a lot of factors. but with conventional way of troubleshooting, check the rotation of both fans. sometimes the brand new one is faster than the old. 2nd. check the level of your cargo since the compartment is open. 3rd. check the contactor if you are single phasing. you might probably need to change the other fan.
@luisedward33363 жыл бұрын
@@leckyjake I have checked all that everything checks out good . I forgot to mention that there is a lot of flooding back to compressor. And when it goes on alarm the system goes on defrost.
@leckyjake3 жыл бұрын
then check the CTP of your compressor. this may sound weird but there are times that 205 appears if this is activated.
@MrShanu6214 жыл бұрын
Really helpful sir 🙏🏻
@leckyjake4 жыл бұрын
Thank you for the support
@senly41473 жыл бұрын
i.am very thank you somuch for helping me sir
@krishnakumarvv2542 жыл бұрын
Very good 👍
@mehendranathramdath71743 ай бұрын
Very good
@chinoyrocks28064 жыл бұрын
Lecky request about sa refcon naman salamat
@leckyjake4 жыл бұрын
Wala na kaming refcon sa barko. May bagong system which is called RCM. Real time temp monitoring ng mismong customer.
@chinoyrocks28064 жыл бұрын
@@leckyjake yun bayong isa isang naka connect sa reefer tapos tangalin pag for discharging na?
@sherwinsarmiento16882 жыл бұрын
What is the running pressure of lowside sir
@arulgnanaesther39428 ай бұрын
great job bro
@madushanashira99543 жыл бұрын
thanks legi
@chathutangakumara36153 жыл бұрын
thank you sir these videos very helpfull
@krishnakumarvv2542 жыл бұрын
Sir can i ask you one dout regarding Aconis 2000
@hakhakuuba50733 жыл бұрын
I live in Mongolia. I want to work as salaryfree worker at your ship as salaryfree worker. I just want to learn how to check and repair reefers...
@zeinz83092 жыл бұрын
EEV How to check for good or bad?
@nizwarnd16363 жыл бұрын
Good.
@leckyjake3 жыл бұрын
Thanks
@brahim212612 жыл бұрын
Verry useful thnx alot
@acesuminguit49113 жыл бұрын
salamat po sir GOD bless po...
@AAminy7 ай бұрын
thanks
@tusharkhanvilkar7991 Жыл бұрын
We have an issue with our container , if set Temp is - 25 C and supply Temp is - 17 C then why Return Temp is stop at - 11 C
@joelboyd92663 жыл бұрын
I have a p268 alarm on a diakin unit what is this about
@leckyjake3 жыл бұрын
Hi, pxxx alarm means pull down timer. It will disappear automatically once your unit will get in range.
@r.41693 жыл бұрын
💯
@andrewdeguzman48233 жыл бұрын
Hi sir sana mapansin mo paano po. Mag calibrate ng smv sir
@Dom-uw4pn2 жыл бұрын
Sir, i already cleaned the eev and now running. What does it mean when evap in temperature is colder than evap out?
@mithileshramteke38823 жыл бұрын
Thank you for information
@rafaelparane25014 жыл бұрын
Sir..do you have an asst electrician on board..or are you a solo ETO..?
@leckyjake4 жыл бұрын
I am a solo ETO but i think next month I will have a Cadet
High pressure. Clean the EEV and purge a little bit
@senly41473 жыл бұрын
Hi bro could i ask you something my daikin has a problem with ice in evapor to compressor
@leckyjake3 жыл бұрын
check your eev and clean it. if situation still the same and the icing is reaching the compressor then remove all the freon and charge the right amount of refrigerant
@hendrowahyudi52073 жыл бұрын
Hai sir.. What if the temperature only goes down to -10°C can't reach -20°C,,what should i do.. Pleasee..
@reymarkdeguzman93474 жыл бұрын
Sir pano mag apply ng electrical cadet sa maerks line sana po masagot or magawan nyo po ng content salamat sir
@senly41473 жыл бұрын
sir i check the evapo solenoid lock so good not restric clog sir but still ice
@leckyjake3 жыл бұрын
Check your refrigerant level
@arnaldomagallanes57673 жыл бұрын
Sir, daikin reefer model LXE10E 147. HOW TO RESET THE FAULT ALARM CODE
@sergiolopez95794 жыл бұрын
Muy bien
@senly41473 жыл бұрын
i am not yet finish it sir you know sometime it reach to set point most of it is became an ice not to set point sir
@TheYachtEngineer4 жыл бұрын
Thank you for this guide. I wish I was your Ass. Elec. Please tell what is the difference in responsibility between ETO and Electrician on Maersk ships. And if they call me to join as Electrician will there be an ETO as my boss? And is it possible to become ETO after working as Electrician on MAERSK???
@alexsyzo26452 жыл бұрын
Мктф привет
@senly41473 жыл бұрын
sir cuold tell me gauge how many psi in the low side and highside and how many psi is enought and how many is not enought sir
@ivanfmartinezm3 жыл бұрын
It depend what type of refrigerant gas uses the system 134 a or R 22 you need to see the PT Table or the app danfoss tool ref slider
@octinocabrito82023 жыл бұрын
sir my problem is the digital display is not ligthing,, thank you
@senly41473 жыл бұрын
hello sir i have some problem with my daikin container freezer with the ice frome evaborator to the compressor what i shuold i do sir?
@leckyjake3 жыл бұрын
First check the freon level. If less then charge 2. Dismantle the eev and clean. 3. Check your filter drier it might be blocked 4. Check your evap sensor and fans
@christophertreeby50084 жыл бұрын
Hands down the worst job on a ship is fixing reefer containers. I would rather crawl around in the bilge testing float switches.
@phaseelectrical94624 жыл бұрын
Eto cource details please
@fredricfrancisco71342 жыл бұрын
guys stop calling it Freon. call it Refrigerant. Freon is a brand.
@patricioflores46692 ай бұрын
Excelente video gracias por compartir tu experiencia, me gustaría hacerte una consulta sobre estos equipos , tendrías algún correo o número de WhatsApp?
@sherwinsarmiento16882 жыл бұрын
Very helpful sir thank you very much
@arulgnanaesther39428 ай бұрын
great job bro
@RupeshThapa-zs1db5 ай бұрын
E307 alarm how to troubleshoot this problem
@senly41473 жыл бұрын
i am not yet finish it sir you know sometime it reach to set point most of it is became an ice not to set point sir