UNDER FLOOR HEATING WIRING - 2ND FIX - A & R ELECTRICS

  Рет қаралды 23,648

A & R Electrics

A & R Electrics

4 жыл бұрын

In this clip I wanted to show how we had gone about wiring this heating system. It was a straight forward job compared to most systems we do.
This is one of the last bits of a house renovation project and we have lots of little jobs left to do.
I had an issue with the mic in this video clip. The mic was on charge while it was in use and caused interference with it. I now know not to charge it while in use ! Sorry, it was too late.
THIS VIDEO IS NOT INTENDED FOR EDUCATIONAL PURPOSES, THIS VIDEO IS FOR ENTERTAINMENT ONLY.
NO COPYRIGHT INFRINGEMENT INTENDED.
Electrical work can be dangerous so please seek a competent / qualified person.
You can find these on the relevant governing body websites.
#electricianlife #electrician #niceic #heatingsystems #underfloorheating #ufh #boiler #heating #centralheating #rentals #electrics #diy
#sparky #sparkylife #niceicapprovedcontractor #worcesterelectrician #worcestershire #worcester #heatingwiring
#igersworcester
Facebook Page
/ arelectricslimited
Instagram
/ arelectricslimited
Twitter
/ arelectricsltd

Пікірлер: 17
@jamesdaly4040
@jamesdaly4040 4 жыл бұрын
Great standard of workmanship by you guys keep putting out videos they are very helpful for young sparks and old timers like me on the new innovations that are coming into the industry good luck
@ARElectrics
@ARElectrics 4 жыл бұрын
Thank you
@alanmarriott9216
@alanmarriott9216 9 ай бұрын
How do you overcome problem with multiple solenoids on one zone and only 1 terminal to connect into in wiring centre?
@ARElectrics
@ARElectrics 9 ай бұрын
Some double up on the actuator terminals but I'm not keen on that idea as you never know if you could overload the circuit board. So when it's more than the 2 actuators from 1 thermostat I link the SL across the other zones. Hope this answers your question.
@alanmarriott9216
@alanmarriott9216 9 ай бұрын
Thanks. Only reason is I’ve had 9 actuators today. 3 in one zone and 6 in the other. So had no chance to get 6 into the small green connector block. Had you use 6 way wago and send fly lead up to wiring centre. Hopefully that’s ok?!
@ARElectrics
@ARElectrics 9 ай бұрын
Have you got an 8 zone wiring Centre? Each zone is able to have 2 actuators on each. You got 9 so theoretically you should be able to get them all in the wiring centre. Link the SL across then to another set of 1 or 2 actuators. I'm always doing these happy to share a picture of video of what I have done if needed.
@alanmarriott9216
@alanmarriott9216 9 ай бұрын
Hi. The one my boss has given is only a 4 zone one! 😂. If you don’t mind sharing a pic or video that would be great please
@peterhughes8327
@peterhughes8327 4 жыл бұрын
what cables needed for central heating other than the 2.5mm for water heater
@ARElectrics
@ARElectrics 4 жыл бұрын
The water heater is separate to the heating system as this is a back up supply to the boiler. The types of cables used vary on what it is being used for and will be different in each install. We used control cables (yy) between thermostats and valves. HR flex for flexing into any equipment ie pump, boiler etc Twin and earth supply to spur for heating system.
@peterhughes8327
@peterhughes8327 4 жыл бұрын
A & R Electrics where does the twin brown go from to the boiler
@ARElectrics
@ARElectrics 3 жыл бұрын
Twin brown? Would that be the thermostat cables your on about? I couldn't say.
@rjkelectrical6086
@rjkelectrical6086 2 жыл бұрын
Why didn’t you have to get a cable from the boiler to the manifold mate?
@ARElectrics
@ARElectrics 2 жыл бұрын
The boiler was only keeping the tank upto temperature. The underfloor heating manifold would just turn on the pump to circulate the water through the tank exchange to heat the water in the pipes for the underfloor heating. Hope that makes sense. Basically a similar setup to what an ASHP would do.
@acelectricalsecurity
@acelectricalsecurity 4 жыл бұрын
those under floor heating boxes are rubbish, they have no earth terminals for the stats and theres no space in them, they must be cheap because thats all the plumbers seem to give me, although my mate did give me a heat meiser one, they are good loads of space and earth terminals for each stat. Plumber did a nice job of the pipes to the boiler, slightly pissed or he was.
@ARElectrics
@ARElectrics 4 жыл бұрын
Unfortunately we can only use what we get given. The UFH box did have a 2 terminal block in the centre (which I didn't notice until the end) for the earth cables, however being an 8 zone unit you would expect there to be more than 2! I used the terminal block to terminate the incoming earth cable and put a link to a WAGO connector for the stats.
@acelectricalsecurity
@acelectricalsecurity 4 жыл бұрын
@@ARElectrics yeah they only have a couple of terminals for the earths never enough though
How To Install Heating System Wiring Easy
21:05
ToolBox Talk For Electricians
Рет қаралды 1,6 М.
1ST FIX SHED / OUTBUILDING - ELECTRICIAN LIFE - A & R ELECTRICS
26:17
A & R Electrics
Рет қаралды 9 М.
Red❤️+Green💚=
00:38
ISSEI / いっせい
Рет қаралды 76 МЛН
UNDERFLOOR HEATING WIRING PROBLEM SOLVING || UK ELECTRICIAN ||
21:01
Waynes World Of Gaming
Рет қаралды 4,6 М.
How to Install Underfloor Heating in an Old Property
28:36
Charlie DIYte
Рет қаралды 92 М.
Underfloor heating control system teardown (with schematic)
19:30
bigclivedotcom
Рет қаралды 59 М.
Under floor heating wiring explained
11:34
Urban Plumbers
Рет қаралды 49 М.
HOUSE REWIRE PART 1 - A & R ELECTRICS
19:28
A & R Electrics
Рет қаралды 2,2 М.
Underfloor Heating - The 2 Big Questions
8:51
Skill Builder
Рет қаралды 101 М.
Your Underfloor Heating Could Be Better - Here Is How.
12:17
Urban Plumbers
Рет қаралды 79 М.