Unimode (ADT) Addressable Fire Alarm System Test 20

  Рет қаралды 13,899

tornadofreak1994

tornadofreak1994

Күн бұрын

Пікірлер: 25
@ExitSign250
@ExitSign250 8 жыл бұрын
Nice! Great test
@SimplexEAS2019
@SimplexEAS2019 8 жыл бұрын
You should get a mass notification strobe (blue, amber, etc), so that you won't have to see the white strobe off while it's doing mass notification.
@tor94
@tor94 8 жыл бұрын
+Hunter Cullen (ilovepolice1) I have been thinking about doing that, but it may be some time before I do. I was thinking about system sensor speaker strobes
@CraigBaker96837
@CraigBaker96837 8 жыл бұрын
Well, at least we now know that the messages have a priority index.
@justnothinghere.109
@justnothinghere.109 7 жыл бұрын
The voice Evac sounds good
@nesmanmain0001
@nesmanmain0001 3 жыл бұрын
I have an NFW-50 (MS-9050UD) and cannot get my NGB-12LX to activate the panel after being programmed. Do you know why this might be happening? Also, does the Johnson controls BG101X or whatever it is (adressable bg-10 rebrand) work with the 9050?
@tor94
@tor94 3 жыл бұрын
I could not get the Johnson Controls module to work with the MS-9050UD or the ES-50X. Only FireLite or Notifier branded modules (from my experience).
@AlarmSystemTech
@AlarmSystemTech 8 жыл бұрын
Nice!
@FireAlarmNZ
@FireAlarmNZ 8 жыл бұрын
Do you have any idea how i could run a 12v voice evac amplifier of a 24v panel? i'm thinking of using a buck converter but I think that might affect the supervisory circuit.
@tor94
@tor94 8 жыл бұрын
+FireAlarmNZ How much current do you expect is going to that? I would say use a voltage regulator but many of those have a 1.5 amp limit
@FireAlarmNZ
@FireAlarmNZ 8 жыл бұрын
+tornadofreak1994 I'm only drawing a 10w load so that's 0.7 amps @13VDC will the voltage regulator cause a trouble on the panel?
@tor94
@tor94 8 жыл бұрын
+FireAlarmNZ it should not. but if you use a voltage regulator, if you draw above the rated amps, the regulator might explode (its happened to me lol)
@FireAlarmNZ
@FireAlarmNZ 8 жыл бұрын
oh goodness, i bet you almost had a heart attack when you smelled something burning inside the fire alarm panel haha. I just ended up powering it from a separate power supply and just used the panel to monitor the circuit.
@tor94
@tor94 8 жыл бұрын
+FireAlarmNZ nice! thats the safer way. and it actually made my panel 100% stop working. I replaced it and it works again!
@radiosnmore1225
@radiosnmore1225 7 жыл бұрын
When it says attention it sounds like the simplex voice
@williamripepi8710
@williamripepi8710 2 жыл бұрын
Because it is. He put two of them together.
@SafetySecurityAlert
@SafetySecurityAlert 7 жыл бұрын
did you really hook it up to the fire department?
@tor94
@tor94 7 жыл бұрын
yes I did
@SafetySecurityAlert
@SafetySecurityAlert 7 жыл бұрын
wow that's very professional!! and cool!
@Dave-ji1hv
@Dave-ji1hv 8 жыл бұрын
Nice! Subbed!
@Brandon_Jarvis
@Brandon_Jarvis 8 жыл бұрын
Hey i am a long time viewer and was wanting to know if its possible for me to run a small system off of a ademco vista 20 security panel and if so how?
@HenBasketFireAlarms
@HenBasketFireAlarms 8 жыл бұрын
Is it connected to a monitoring station? If so, you shouldn't.
@Brandon_Jarvis
@Brandon_Jarvis 8 жыл бұрын
no its not connected to a monitoring station.
@Dave-ji1hv
@Dave-ji1hv 8 жыл бұрын
Yes a youtuber by the name DoverDucy has a system running off of a security panel. Go see some of his video's on it. They are a little older.
@HawkinsWX
@HawkinsWX 8 жыл бұрын
The security system voice it Siri
Unimode (ADT) Addressible Fire Alarm System Test 19
6:09
tornadofreak1994
Рет қаралды 71 М.
Unimode (ADT) 9050UD Addressable Fire Alarm System Test 21
11:47
tornadofreak1994
Рет қаралды 53 М.
Or is Harriet Quinn good? #cosplay#joker #Harriet Quinn
00:20
佐助与鸣人
Рет қаралды 50 МЛН
Unimode (ADT) 9050UD Addressable Fire Alarm System Test 22
6:22
tornadofreak1994
Рет қаралды 1,7 МЛН
Unimode (ADT) 9050UD Addressable Fire Alarm System Test 18
6:28
tornadofreak1994
Рет қаралды 9 М.
Fire Alarm Demo Board #1
4:55
tornadofreak1994
Рет қаралды 12 М.
Software EAS Encoder
8:39
tornadofreak1994
Рет қаралды 21 М.
ECC-50/100 Ins & Outs
16:51
Firealarm Discovery
Рет қаралды 163
Firelite ms-5012 system test 2 #alarm #systemtest
4:05
FIRE Alarm guy
Рет қаралды 703
Board System Test 326 l #FireAlarmFriday
5:30
Fire Alarm 33
Рет қаралды 175
Library Pull Station: Simplex 4100U School Fire Drill for January 2020
1:39
thatelevatorperson
Рет қаралды 174 М.
August testing
2:16
Dilson alarms And electrics
Рет қаралды 31
(Fire alarm) cloquet high school simplex 4906-9127 Minnesota  pop corn machine set them off
2:05
Cloquet Fire department / aydenlamere