Unvented Cylinder For Hot Water - Fault Finding - Safety Controls - G3 kzbin.info/www/bejne/nmOkoXhtp6pmgs0 How To Service An Unvented Hot Water Cylinder kzbin.info/www/bejne/hmPZXoqbp82XatU How Unvented Hot Water Cylinder Works - Plumbing Training Video kzbin.info/www/bejne/aIu0eWCKnKlql9E
@mparthur1443 жыл бұрын
My unvented hot water system has no tundish.
@ernestosilva54782 жыл бұрын
That was grateful to remind me about, I must forget because sence my qualifications I have being doing different things tanks you to share your videos 👍
@jimmyfreemantle8793 жыл бұрын
I had the pleasure of having part of my ACS course taught by roy. He is an absolutely first class instructor.
@COYBIG19673 жыл бұрын
How good is this for young trainees to be getting quality training from a fully qualified teacher and someone like Allan whos been in the trade for so long and knows so much and all for free.
@0808-w9q3 жыл бұрын
Roy is a legend! Great information.. Alan is even more of a legend for bringing us informational videos like this! He’s a good bloke, his attitude towards helping others is amazing , keep it Alan, appreciate all the videos 👍🏻😎
@jondixon27444 ай бұрын
Very informative. I've just moved to a house with an unvented system and this helped demystified for me
@raykhan6416 Жыл бұрын
Thanks again for a simple way of understanding how the system works
@johnmoore35692 жыл бұрын
Roy, thanks for going over the safety control devices on the unvented cylinder. You have explained it logically and thoroughly bringing in field experience which is vital for new trainees. Thanks again.
@grahamsmith8156Ай бұрын
Just watched this video. Really helpful. Doing my G3 assessment in the morning!
@garyredfern25422 жыл бұрын
Watched this video a few times. Doing my G3 assesment tomorrow. It was a great help. Thanks.
@chohanchohan82083 жыл бұрын
Allen and Roy You guys smashed it with the G3 videos , I learnt more on these than the half day course I done For sure
@oc1625 Жыл бұрын
Great video, thanks. The fault finding aspect of my course wasn't very comprehensive so this has really plugged a gap for me, many thanks.
@AllenHart999 Жыл бұрын
Glad it helped!
@AllenHart999 Жыл бұрын
Thanks very much for your comment, please consider subscribing to support the channel 🙂
@karamathussain4063 жыл бұрын
Great video as always. Thanks for the refresher about G3. As they say safety is paramount in all cases.
@mohammednadeem72743 жыл бұрын
Great video video Allen including Roy, very useful information provided in the video regarding the unvented cylinder. Great work mate.. 👍👍😀
@MrMedicalUK4 ай бұрын
Not sure if i missed it but what if the PRV fails? I assume that would make everything fail along the installation safety features apart from electrical?
@markokornas931Ай бұрын
Thanks for video like that. But about cost side. Why people going to invented cylinders? Is it cost effective or hot water effective or maybe possibility to join renewable sources of energy? Thanks.
@nigel8892 Жыл бұрын
Hi I'm a customer and have the tundish but rather than cold water it is warm water. Could that still be a failed expansion bottle. The thermostat appears to be ok. I will ask if the plumber who services my boiler has a g3 cert,
@joncrawshaw67768 күн бұрын
I had the boiler serviced, that feeds the unvented cylinder, and now the water is not being heated enough. Its only warm. Any ideas what caused this and how to fix?
@stevemartin2992 Жыл бұрын
Hi really liked the video can i ask i have recently had my megaflo unvented tank changed under warranty everything was fine untill the last few wks my hot water is scolding hot i have had baxi out to check the tank and they say its fine and my problem could be the tmv valve failed after watching a couple of your videos just worried now a valve on the tank is not right very interesting thanks again Steve
@the-ronster2 жыл бұрын
I have seen a company fit an unvented Ideal cylinder as a replacement onto a gravity system heated by a Baxi back boiler. I always thought these cylinders must be fitted to a fully pumped system - S or Y plans?
@clivecurniffe9100 Жыл бұрын
Thanks Viva, I am a plumber for many years, unfortunately I am not qualified to work on unvented cylinders. I was called out to an emergency leak coming from a unvented hot water cylinder. The person had replaced the emersion but hadn't fit the emersion properly, he had put ptfe tape on the threading instead of hawk white. I had to drain down and reseal the emersion and refit. On my arrival I also noticed that he had put a pressure air release valve on the top of the cylinder, nothing else, is that permissible? If not I would like to notify the customer. Thanks Clive
@MrMedicalUK4 ай бұрын
Can you just confirm that this demonstration with 2 tundishes, when there is only 1 fitted and th ninlet control group is piped up to the same tundish as the T&P ? Is that correct?
@derrickrobertson4715 Жыл бұрын
Allen, Say you have a Hive system. You program a schedule for 1 hour hot water heating. It calls for hot water, heats water.. If the cylinder gets to desired temperature.. say 60 or 65c, does this then turn off the gas and hot water heating or does it run for 1 hour? Looking at how to set up Hive so economical and doesnt burn more gas than needed. Any gauges you can add to cylinder to measure temperature of water in cylinder as that would be so useful to know if you need to heat hot water and how hot it is.. I would have thought these were built in as standard as a very useful reading to have for water temperature
@AllenHart999 Жыл бұрын
Cylinder stat
@fredflintstone1428 Жыл бұрын
Looking at a Gledhill Lite-Stainless Unvented Cylinder manual, it says that any direct cold taps (including toilets) should be plumbed from the incoming mains and not from the balanced cold feed that exits from the inlet control group. It also shows that the supply to the bath should be piped in 22mm and should be a tee off from the 22mm mains that supplies the unvented cylinder G3 input. Why not take all cold connections from the balanced cold connector contained withing the G3 valve? Wouldn't that keep the whole system pressurised at 3bar?
@kevind71503 жыл бұрын
Anti Vac Valves. Some Worcesters cylinders, have them built into the control group. Would you recommend fitting one, if the cylinder is located, above the highest draw off point. Where syphonage is more likely? If so would you fit it on the inlet or outlet. I have previously, fitted them on the inlet. As the control group is on the inlet pipe. Would it make any difference?
@jennyomalley7634 Жыл бұрын
For a 10/15 Lt under sink water heater , do you need a valve that drains to outside ??
@TuffBaddi2 ай бұрын
Thanks so much for the videos. I’m hoping for some help on a specific issue that I’m having at home. I have a property with this kind of setup. I've had a few people look at it (professionals and family members) who couldn't really explain it to me. I get really low hot water pressure compared to the mains cold water coming in, and the water pressure for hot and cold on the second floor is much lower than on the ground floor. The boiler has recently been replaced and it set up on the ground floor. There are no water outlets on the first floor, and then on the second floor we have the main bathroom and shower room. Water comes out of the taps and is at a good (hot) temperature, but the pressure makes having a shower almost unusable and the taps completely die if anyone is using the tap in the downstairs kitchen. The Radiators seem to be working fine so I’m looking for some places to troubleshoot myself before I pay a load of money to get another pro in. These videos have been extremely helpful for learning what all the different valves do and what is expected behaviour.
@derrickrobertson92782 жыл бұрын
What would happen if the boiler is set at 65c and the thermostat on the cylinder is set at 45c..would we see hot water vented? Would fault would cause intermittent hot water vented whilst hot water heating up?
@johnfox9823 жыл бұрын
Doing this course right now, this explains it very well, great video!
@youmadbro41383 жыл бұрын
Love the videos Allan 👌. What's your thoughts on Hydrogen combustion boilers and hydrogen fuel cells?
@MrMedicalUK4 ай бұрын
Can you confirm what you meant by tweaking to see if it will reseat? Which way would i turn the valve? Open then close? Close? Open? Close then open? Lol?
@leeedwards37832 жыл бұрын
great video. Thanks for your time. On the controls video you did for unvented you disconnected the wire in the thermostat to see if this disabled the 2 port valve. Was this from the thermostat or the link from the thermal cut out? Thank you
@thebritishpatriot12 жыл бұрын
So if the pressure is too low and the cold water is leaking into the tundish do you pressurize the vessel with water or do you recharge the tank with air. I say this because of what you normally do with combination boilers.
@buzania86173 жыл бұрын
Hi Alan Amazing video as always, I would like to get the Kane 358 but I can't get on any website, can you please share a link if you can Many thanks
@jeffcotton30123 жыл бұрын
Have you had any problems with noise from expansion vessel when hot tap opened
@leegibbs5317 Жыл бұрын
My G3 certificate has recently expired. Spooky that this video turned up in my feed!
@ianclaytion9990 Жыл бұрын
Hi I’ve been to repair a unvented cylinder the water was coming out of the blow off I change the expansion vessel was low and when the boiler kicked in and started heating the cylinder it blew off again so I changed the inlet valve with the pressure reducer on and new prv turned boiler on and and same thing happens start on cylinder 60 degrees and there’s a return pump on turned that off still happens can you help Thanks Ian
@alifaisal80002 жыл бұрын
Hi Do you run an apprentice scheme as well so newly qualified plumber can take your advice?
@rajbhundia1292 жыл бұрын
I have a megaflo unvented cylinder and have to keep recharging the air gap 3-4months. Is this normal?
@HelloCreativeFilm2 жыл бұрын
We have 14 year old mega flow heatre sadia unvented cylinder in apartment never been serviced as didn’t realise it was necessary. Recently found leak on base of cylinder. Have recharged it to instructions and took 25 minutes to stop gurgling. Every thing seemed fine. A day later the drips in the tundish started again slow but constant. I reenergised a few more times over the last week but still dripping and out of the bottom side of the Tundish where connected to pipe seems to be leaking down pipe into base. Also noticed the water when I have a shower seems a lot hotter then normal. One plumber suggested replacing the whole cylinder however don’t have the money for that at the moment - any ideas what it could be.
@sheriefgerges77893 жыл бұрын
What I would like to ask when you have an inlet multi control failed to replace , do I need to replace it with same one or any multi inlet control will cover Thank you
@dennisphoenix13 жыл бұрын
It would have to have the same design charecteristics , say 3.5 bar reducing valve and 6 bar expansion valve etc . If it's still in warranty then a like for like would keep the warranty. If you aren't bothered then a generic part will do .
@sheriefgerges77893 жыл бұрын
@@dennisphoenix1 Thanks a lot
@robbiebicker52273 жыл бұрын
Great video Roy 👍
@londonman868811 ай бұрын
what would cause the water to go hot for 30 seconds and then go luke warm ?
@sheriefgerges77893 жыл бұрын
The Video more than amazing Thanks alot for another great Video
@smithersjones30183 жыл бұрын
Great video. I've been out to quite a few office buildings for issues with undersink water heaters, usually for complains of foul smells where prv's have been connected to wastes without sealed tundishes. I've seen plenty of poor installations done by builders. Are you supposed to have g3 for 10 & 15 litre under sink water heaters?
@dennisphoenix13 жыл бұрын
This question came up recently with under sink water heaters , anything 15 and under is outside of the scope apparently. No certification is reqd . But looking at the video it really needs to be brought in .
@smithersjones30183 жыл бұрын
@@dennisphoenix1 I agree. Crazy that there's no qualifications needed for these heaters.
@dennisphoenix13 жыл бұрын
@@smithersjones3018 I had my head in a suspended ceiling and saw a small water heater for the disabled toilet hand basin , I was looking at then realised there is no expansion vessel. No idea who has done that .
@smithersjones30183 жыл бұрын
@@dennisphoenix1 Tbf some isolations don't require expansion vessels if theres a certain about of pipework connected to the heaters. The pipe work can soak up the expansion. I've definitely read something about that in the intructions for ariston heaters. You can get other makes that come with specific taps that vent. You've got to read the manufacturers instructions. There certainly is a lot of bad installs about though.
@dennisphoenix13 жыл бұрын
@@smithersjones3018 I did wonder whether there was an internal air gap as the mega flow has. I remember from the G3 course it said that if the incoming pipe was increased to 28mm it would allow for the expansion. Watching the video the pressure soon goes up when the expansion vessel is removed
@davehunter69203 жыл бұрын
great video thank you Allen and Roy!!!
@AllenHart9992 жыл бұрын
Thank You
@bigbawsdogg3 жыл бұрын
Hi Allen, great and interesting videos even as a non plumber. I wanted to ask you what is the best prevention for sludge coming into the boiler and blocking it as this is never covered by insurers. Beyond just a magni filter
@dennisphoenix13 жыл бұрын
A good flush and rust inhibitors are the best way . You can fit a spirotech filter for non magnetic debris
@ionsprinceana50482 жыл бұрын
Allan and Roy thank you very much guys for such a brilliant and informative videos and for your hard work to pas on your knowledge👍 I would like to have a request if it's possible about wiring switching from vented cylinder to unvented on Y plan. Many thanks!
@AllenHart9992 жыл бұрын
We will see what we can do. I am working at NGCFE at the moment. i will ask. Thanks.
@samstevens93173 жыл бұрын
Hi Gents. Is there an entry requirement for a G3 course? Doing a fast track gas later this year so will have my gas tickets next year. Looking to add G3 in after that.
@cliveramsbotty60773 жыл бұрын
experience required but you shouldn't have trouble getting it done
@dennisphoenix13 жыл бұрын
Either a recognised qualification like a NVQ etc or proof of experience in the industry. I am a electrician and I have done the G3 .
@rodknee873 жыл бұрын
If a customer complains of reduced flow rate from an unvented what would it likely be? Can you adjust the pressure reducing valve to increase flow if needs be?
@royfugler99713 жыл бұрын
Reduced flow rate is normally the strainer being blocked, the pressure reducing valve are normally factory set and can't be adjusted. I hope this helps.
@cliveramsbotty60773 жыл бұрын
you can adjust most pressure reducing valves just take the plastic cap off.
@dennisphoenix13 жыл бұрын
You would need to check the upstream and downstream pressure to see if the prv is working correctly. You should not alter the manufacturer supplied parts . As said check the strainer etc
@tamthompson293 жыл бұрын
Can you get an air lock at the taps with this system, every other hot water tap works apart from bath and shower
@davidhawes77832 жыл бұрын
Thanks for this vid. Good explanation. My pressure vessel (potable, unvented system) fails regularly, causing the pressure relief to go. Plumber comes (I've used different ones for 2nd and 3rd opinions) and says, 'yep, I'll need to replace the expansion vessel'. This happens about once a year, and then low and behold, it lasts a while and fails again. I’ve asked plumber after plumber why this keeps happening, perhaps another more systemic fault -with the multi valve perhaps?? But everyone just says replace the expansion vessel... Oh, and they tell me off for the expansion vessel not being mounted on the wall... it starts off on the wall but when its gets heavy with water (when it fails), it falls off. Also leaving it on the floor makes it easy to feel how heavy it is and tell when its getting near needing replacing again! Any ideas of what else could be causing the vessel to repeatedly fail please? Then I can suggest this to the next plumber (when they're available after Christmas!)
@thunderfromdarkskies Жыл бұрын
Not sure if you solved this problem but I've seen this happen before with one of my customers. In this case it was caused by an unbalanced hot and cold water feed to a mixer tap somewhere in the property. The hot water at the pressure reduced pressure of 3BAR from the cylinder but the cold was at 5 BAR straight from the mains. This caused the 5 BAR cold water to feed-back via the mixer tap back up the hot-water pipe and into the cylinder bringing it up to 5 BAR. So even though the cylinder should have been safely at 3Bar behind the pressure reducing valve, it was constantly slowly rising up to 5 BAR after each time the hot water was used. This constant high pressure/low pressure cycling was causing the pressure vessel to regularly fill with water and fail prematurely. Solution was to provide a balanced cold feed to the mixer tap.
@davidhawes7783 Жыл бұрын
@@thunderfromdarkskies excellent intel. Thanks for the reply, I’ll look in to this. Makes a lot of sense.
@CaliforniaLloydUK3 ай бұрын
Great video 👍🏼
@markryan50163 жыл бұрын
Hi. I've got a problem with my Megaflo cylinder. Every time it starts heating the water there is a loud pinging/banging noise coming from where it is installed. I've had British Gas out numerous times to no avail. The first six months after the installation, there was no noise at all. I've done a cylinder recharge which helped for a few days but then the noise returned. Any advice would be appreciated, thanks.
@mparthur1443 жыл бұрын
I once had one engineer recommended by the manufacturer who wanted to come in for £110 second time in two weeks to fix the same problem. I turned him away.
@iainmackay73543 жыл бұрын
Might be a stupid question but what is difference between system boiler and heat only
@royfugler99713 жыл бұрын
Hi Iain, No such thing as a stupid question. A system boiler has an expansion vessel and circulation pump built in, a heat only boiler doesn't.
@iainmackay73543 жыл бұрын
@@royfugler9971 thank you
@rickysheldon43552 жыл бұрын
Awesome video
@jasonthompson6152 жыл бұрын
Exceptional
@samwhite67343 жыл бұрын
Great vid 👍
@lcs752 жыл бұрын
You have a Isolation valve on inlet to cylinder after expansion vessel. !! See video 27:15 min