@adamr.jensen3860
@adamr.jensen3860 6 жыл бұрын
Saving data to USB starts at 03:39 Be aware that at 5:13 when he selects the "Sto/Rcl" button, he has first selected the "Shift" button (not shown) and therefore it goes to the "interface" as shown in blue beneath the "Sto/Rcl" button.
@leonardchijioke392
@leonardchijioke392 3 жыл бұрын
I need to conduct an experiment using the thermocouple. First of all, i am measuring fruit core temperature inside a refrigerated transport container (but will be stationary). When setting up the thermocouple, what temperature type is suitable for this measurement? I am quite unsure if to use Temp (Type C or T). Where can i find information on this particularly? Secondly, my experiment will last for at least 10 days, so i intend to do it remotely using the USB data logging method. I will set it up to measure at 10mins interval, any advice on the required size of USB i may be needing? I am scared of losing data as this is my second and last research experiment. Thank you in anticipation.
@carlosramirez5015
@carlosramirez5015 Жыл бұрын
how can i measure the current?
@franciscolozano9585
@franciscolozano9585 4 жыл бұрын
Muchas gracias, estamos aprendiendo a utilizar el equipo. Nos va a ser muy útil ver estos videos.
@srijan.sikhar.dutta.
@srijan.sikhar.dutta. Жыл бұрын
not able to add the instrument, it is not showing
@franciscolozano9585
@franciscolozano9585 4 жыл бұрын
What´s the diference betwen connect the equipment with USB cable or LAN cable, because of at first to connection with LAN the PC did not register it. Can you send to us more videos with examples to measurement termocuples, thanks
@KeysightHandsOn
@KeysightHandsOn 4 жыл бұрын
Francisco Lozano The LAN cable will work but you have to have wifi off. So, the laptop and 34972A are the only connections. If you connect your laptop and the 34970A to the same router then you can have both the internet and the DAQ.
@franciscolozano9585
@franciscolozano9585 4 жыл бұрын
@@KeysightHandsOn Thanks for your reply.
@rpbale
@rpbale 5 жыл бұрын
Is this software compatible with your older 3458a multimeter? If not what PC data logging software do you recommend for the 3458A bench meter?
@dadsdasd2972
@dadsdasd2972 6 жыл бұрын
Hi, thank you for this video firstly... What type usb cable you connected as a first method??
@dadsdasd2972
@dadsdasd2972 6 жыл бұрын
Can I connnect via LAN using Benchlink Data Logger 3
@KeysightHandsOn
@KeysightHandsOn 5 жыл бұрын
@@dadsdasd2972 The instrument uses a USB "printer cable" USB A to USB B cable.
@nitinks5140
@nitinks5140 7 жыл бұрын
can we use this instrument to acquire data from a PCB vibration accelerometer ( model : M353B15)? I would be grateful for your suggestion.
@KeysightHandsOn
@KeysightHandsOn 7 жыл бұрын
Nitin ks. You may want to call our technical support center to discuss your application. The 34970A and 34972A can measure the RMS voltage from the sensor which would represent the total vibration. However, you may want to use an FFT analyzer to see vibration force by frequency. Many oscilloscopes have FFT capability but low resolution. Dedicated hardware / SW is available if you want more resolution and faster update rates.
@nitinks5140
@nitinks5140 7 жыл бұрын
thank you for the reply.
@KeysightHandsOn
@KeysightHandsOn 7 жыл бұрын
no problem. Good luck with your application.
@Allison-gf3cg
@Allison-gf3cg 7 жыл бұрын
Is it possible to turn off the sounds (relay?) when scanning?
@KeysightHandsOn
@KeysightHandsOn 7 жыл бұрын
Allison you are correct the scanning sound is from the relays and cannot be turned off. The 34902A is less noisy as it uses reed relays, in a lab environment the sound is not extremely loud. Another solution is to monitor the 34972A remotely.
@alexwttc
@alexwttc 4 жыл бұрын
THANKS
@KeysightHandsOn
@KeysightHandsOn 3 жыл бұрын
Welcome
Making Humidity Measurements Using 34972A and Data Logging
8:49
Keysight Hands-On
Рет қаралды 10 М.
Keysight DAQ970A Data Acquisition Cards
10:49
Electro Rent
Рет қаралды 2,9 М.
Try this prank with your friends 😂 @karina-kola
00:18
Andrey Grechka
Рет қаралды 9 МЛН
blue clock op (2.26 clock avg)
1:21
Danny Morgan
Рет қаралды 81
USB Data Logging with an Agilent 34972A Data Acquisition System
11:43
Use PyVISA to Program Test Tools with Python - Workbench Wednesdays
13:35
element14 presents
Рет қаралды 40 М.
Keysight DAQ970A Data Acquisition System Review
11:07
shabaz
Рет қаралды 8 М.
Can I Make QR Code Damascus?
19:23
Alec Steele
Рет қаралды 688 М.
How to Make Temperature Measurements with a DAQ
4:55
Keysight Labs
Рет қаралды 29 М.
Welcome to the world of oligarchy.
7:42
Senator Bernie Sanders
Рет қаралды 1,6 МЛН