Vaillant Arotherm Plus Air Source Heat Pump 2021

  Рет қаралды 10,951

Dore Woodman

Dore Woodman

Күн бұрын

Пікірлер: 32
@TrevHutt
@TrevHutt 9 ай бұрын
Excellent
@debs55
@debs55 6 ай бұрын
Hi bill do you leave your emersion on all the time because so far I'm not thrilled with it as radiators coming on when it feels like it.
@myatix1
@myatix1 2 жыл бұрын
Nice video! It would be nice to see a detailed installation of a vaillant ashp
@dorewoodman
@dorewoodman 2 жыл бұрын
Hi Alan, we do have a couple of videos on our channel with a full installation
@skiiddy
@skiiddy 3 жыл бұрын
I’m impressed. Could you explain how the aeroTherm plus is able to generate heat flows at 75 degrees as advertised by Vaillant?
@dorewoodman
@dorewoodman 3 жыл бұрын
Hi Simon, Thank you. It is all down to the refrigerant used, it has the ability to heat water at higher temperatures without the need to use a larger quantity of refrigerant and a larger compressor therefore enabling the heat pumps to work and comply for domestic uses etc. Of course the higher the temperature of the flow used for heating the less efficiency you get from the units themselves and I would always err on the side of caution with looking at heat pumps to supply these high temperatures. I hope that helps. Jason
@skiiddy
@skiiddy 3 жыл бұрын
@@dorewoodman thank you Jason. I’m building a passive house next year and been advised that we would need a 12kw system to accommodate four en-suite bathrooms and a the house overall will extend to almost 300m2. I’ve only ever had vaillant in my properties and would likely only ever use their kit however, I’m torn between this system and Viessmans Vitovalor, in essence a fuel cell which, although relies on natural gas, converts it to hydrogen and simultaneously, generates electricity. Do you install these?
@dorewoodman
@dorewoodman 3 жыл бұрын
@@skiiddy the Viessmann Vitovalor is certainly an interesting alternative. I think it comes down to a few variables; Will planning allow for effectively a fossil fuelled heating system? Is the area in which you are building the property "off grid" i.e no gas supply? Will a gas supply need to be installed to the property? With that in mind, comparative install costs? Do you wish to achieve a carbon zero house? What grants will be available etc? Which area of the country are you based Simon?
@MarkGaudie
@MarkGaudie 2 жыл бұрын
I’m hoping I don’t need a buffer with my Vaillant install. Take up more space than I would like in my small utility.
@dorewoodman
@dorewoodman 2 жыл бұрын
What size is the heat pump? Rads or UFH?
@MarkGaudie
@MarkGaudie 2 жыл бұрын
@@dorewoodman we have 30 meter squared of under heating in the lounge/kitchen/diner. Then 2 older lounges with 2 massive double connector rads about 12000 plus BTU. 3 bedroom on the first floor with large double convector rads then a 4th bedroom with electric under floor heating and a massive towel rad in the en-suite. The bedroom itself has a 6 foot tall decorative double rad.
@MarkGaudie
@MarkGaudie 2 жыл бұрын
Half of the downstairs is new build with all 150mm insulation in the floors and walls.
@MarkGaudie
@MarkGaudie 2 жыл бұрын
We have all brand new windows and doors and the loft conversion was only completed Feb this year so all to latest building regs. The only other thing we could do to the house is to dig all the concrete floors up downstairs in the 2 old lounges and hallway then insulate the floors and lay new slab. This wouldn’t be a viable option for us with expensive solid oak parquet flooring in these areas. Or maybe rip all the new glazing out for triple glazing.
@handle1196
@handle1196 2 жыл бұрын
Do you still need planning for a self build that has recent planning permission accepted? Any idea of the cost of planning for a ASHP? Are you adding multiple room stats per floor for multi zone, or adding one stat per floor that opens or closes all zones on that floor, and are you using weather compensation or load compensation? weather
@Haik0
@Haik0 7 күн бұрын
I belive one of those SensoComforts can run more then 1 zones, why would you need a whole another unit?
@dorewoodman
@dorewoodman 6 күн бұрын
A SensoComfort can only temperature control one zone and would require an additional VR92 if you wanted to temperature control more than one zone. You can set up the parameters for all zones via the SensoComfort
@highlandjournalart654
@highlandjournalart654 2 жыл бұрын
We’ve just had this unit fitted, we’ve got hot water but can’t get the central heating on despite outside temperature falling and a high demand one chosen. Any ideas?
@dorewoodman
@dorewoodman 2 жыл бұрын
There are a number things that could be influencing that ... Is the outdoor sensor reading the outdoor temperature correctly? ..... which thermostat do you have controlling the heating? .... is it set up correctly under the settings? .... Do you have a buffer and are the thermistors positioned correctly? .... How many heating zones do you have?
@highlandjournalart654
@highlandjournalart654 2 жыл бұрын
@@dorewoodman thank you for your reply, I’ve found a fault logged re outdoor sensor so suspect it’s that.
@TimiStyle93
@TimiStyle93 3 жыл бұрын
Great video. What is your take on the uniTower?
@glenphillips6634
@glenphillips6634 3 жыл бұрын
Hi I’ve just had the 12kw system installed and was wondering how hot the ufh pipes should be ,coming into the manifold they don’t seem to be getting warm but the pumps are working I would of thought it should be coming in around 45 degrees my installer says it is working but will be a slow process as in if it’s 5degrees in the pipe the heat would be 5 degrees more and increase as necessary which doesn’t seem as efficient as it’s on constantly could you give me any advice please
@dorewoodman
@dorewoodman 3 жыл бұрын
Hi Glen, Thank you for your comment. A couple of points: The heat pump is usually set up with a 'Heat Curve' and uses its weather compensation components to determine the flow temperature. As the temperature outside increases, the flow temperature from the heat pump decreases and vice versa as outdoor temperatures fall. You should get 45 degree flow temperatures when the outdoor temps are cold enough to allow it, if that is how the design parameters are set up. In the summer the heat pump shouldn't be on at all for heating; if for any reason it was the flow temperature could be as low as 15-17 degrees. That said your heating system is not only determined by the flow temperatures but also the thermostat temperatures. If your thermostats for the UFH are set to 20 - 21 degrees and you have achieved these temperatures then there will be no need for the heating to be on at all, if that is the case and the pumps on the UFH manifolds are still running then it may be incorrectly installed/wired. I hope that helps.
@glenphillips6634
@glenphillips6634 3 жыл бұрын
@@dorewoodman thank you I think that explains it better I was just trying to test it and had set the temp to 24 but the pipes just didn’t seem to get any warmer so was really confused as to if it was working
@dorewoodman
@dorewoodman 3 жыл бұрын
@@glenphillips6634 You are welcome.
@hvacdesignsolutions
@hvacdesignsolutions 2 жыл бұрын
How are those SCOPs calculated?
@UpsideDownFork
@UpsideDownFork Жыл бұрын
Great content but get yourself a microphone. Rode videomic pro or something similar will make all the difference. Or a rode wireless go. There are so many easy options to improve it.
@blackmagnetec
@blackmagnetec 2 жыл бұрын
what brand is the compressor?
@zalkhirsan9481
@zalkhirsan9481 3 жыл бұрын
Are these the pressure cylinders size on left and right
@dorewoodman
@dorewoodman 3 жыл бұрын
Hi Z Alkhirsan, The cylinder to the left of the heat pump as you look at it is a Buffer Tank which can be in different capacities and the Hot Water Cylinder is to the right. The one in this video is a 45 litre buffer tank and a 250 litre cylinder for this particular installation. The Hot Water Cylinders can range from 150 to 300 litres typically but that is not to say for much larger properties 500 to 800 litre cylinders are available. Many thanks, Jason
@zalkhirsan9481
@zalkhirsan9481 3 жыл бұрын
@@dorewoodman thanks for that so both are needed
@dorewoodman
@dorewoodman 3 жыл бұрын
@@zalkhirsan9481 generally yes, with this particular heat pump.
@paddyeason9677
@paddyeason9677 Жыл бұрын
Interesting. I’m surprised how messy and ugly the layout was on the inside… looks like something from a car boot sale!
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
3 years living with a heat pump - stats and my main take-away
22:05
Cold Climate Heat Pumps for Radiant Floor Heating. No gas, no boiler!
1:05:16
Heat Pump Retrofit in a 1980s House: What's Involved?
17:17
Urban Plumbers
Рет қаралды 89 М.
Let's Be Real About Heat Pumps!
15:13
Electric Vehicle Man
Рет қаралды 236 М.
Heat Pumps - Our 'Ugly' Truth!
20:17
Electric Vehicle Man
Рет қаралды 187 М.
Vaillant heat pump myth busting
5:29
VaillantUK
Рет қаралды 1,7 М.
Heat Pump Installation in Sunderland | Vaillant & Primary Pro | Heat Geek Elite
14:03
Gas Boilers No Longer Make Sense, Here Is Why.
12:23
Urban Plumbers
Рет қаралды 81 М.
Our experience with Air Source Heat Pumps
17:53
Modern Thatch Living
Рет қаралды 33 М.