Please Like , share and subscribe my channel to get the regular updates .Channel Link .kzbin.info
@erazharuddin27354 жыл бұрын
Please tell valve inspection activities of workshop
@kuttynarayanan31622 жыл бұрын
Thanks 👍 sir
@guddy4066 ай бұрын
myself soumen. I complted cswip 3.1, Bgas,iso 9001:2015 . and Aramco sap id. I have doubt what to do next api 510+570 or cswip 3.2. I have 14 years exp and want to be a QA qc manager in future
@WeldingNDTInspection6 ай бұрын
Next is Bgas and then api 510 and 570
@engineer68223 жыл бұрын
God bless you 🥰 🥰 🥰
@WeldingNDTInspection2 жыл бұрын
Thanks
@nageshbaghel32393 жыл бұрын
Informative
@WeldingNDTInspection3 жыл бұрын
Thanks a lot , Please like , share and subscribe my channel to get the regular updates .
@nageshbaghel32393 жыл бұрын
@@WeldingNDTInspectionsure
@ilangkumarkumar3774 жыл бұрын
Thank you sir
@WeldingNDTInspection2 жыл бұрын
Welcome and subscribe to not missed any videos
@venkateshsiva77553 жыл бұрын
Where did u get shell & seat pressure from code(API 598/Api 6d) please mention me the page number
@WeldingNDTInspection3 жыл бұрын
Valve Shell Test Pressure The API STD 598 refers you to the table 3 in the standard and provides the test pressure for cast iron valves based on their ratings but you know the majority of the industrial valves are made from cast steel. For cast steel, the API 598 refers you to the ASME B16.34 for test pressure. The ASME B16.34 indicates that the shell test shall not be less than 1.5 times the 38°C (100°F) pressure rating, rounded off to the next higher 1 bar (25 psi) increment. For example, if you have a valve with cast steel material (A 216 Gr. WCB) and rating of 2500, you should refer to the table 2.1.1 in ASME B16.34. The table says your working pressure is 425.5 bar at 38°C (100°F). It equals to the 6524.85 psi. Now multiply this value by 1.5 and your test pressure will be 9382.3 psi. You have to round it to the next 25 psi, and it will be 9400 PSI. Valve Shell Test Duration On both API STD 598 and ASME B16.34 shell test duration depends on the valve size. The valve size less or equal 2 inch the test duration will be 15 seconds, between 2 1/2 and 6 inch 60 seconds, between 8 and 12 inch 120 seconds and above 14 inch will be 300 seconds.