I am so caught up watching how you troubleshoot the problems. From obvious to the inobvious! Awsome work!
@puckme31173 жыл бұрын
You have solved the issue for me, as my new S9V2 (February) was giving me this same problem when I turned on Cooling for the season, and the installer did not believe me that there was an issue. I had to set the Menu to 3 tons for my 1.5 ton unit to get the proper CFMs, as indeed it was running on low speed. This meant no lower speed for the fan at 50% setting. After 3 weeks of waiting and having been told that nothing was wrong, and that I should contact Trane directly, I searched for info and found your video. The installer had indeed forgotten the jumper. He did not and would not come to my home to see what might be wrong. Thanks so much.
@henryharrison39885 жыл бұрын
I like my straight cool with 10kw heater. 15 years old and only replaced the Dual capacitor about 3 years ago. And did a coil clean. still going strong.
@billybassman215 жыл бұрын
I like two stage more as a reserved cooling capacity on hot days than for dehumidification. In other words size it right in first stage and have the second stage be oversized for the space to maintain the setpoint even on the hottest days. Also use the Y Low terminal and set the CFM to 450. Using the BK as Trane states causes too much air flow in first stage keeping the humidity around 50% VS 45 which is more comfortable.
@shawnd5675 жыл бұрын
That's the exact opposite of what you want. You want the first stage for mild 80-85° weather and the 2nd stage for 85-95°. It'll help bring down indoor humidity and maximize comfort.
@danthonywalker4686 Жыл бұрын
Thank u. Made my day. 3 previous trips to my customer.
@PatIreland3 жыл бұрын
Nice concise video, also very good explanation of 1 stage cool & 2-stage heat.
@Negative13Prod5 жыл бұрын
You don’t need to jump it. Move the wire to Y1. Go into the menu and check the settings.
@renecuevas41284 жыл бұрын
Love ur accent first. Love ur yellow truck second i drive one for the last 10 yrs.....in the field for 30. And 3rd ur troubleshooting skills are priceless. Be blessed Cool Guy😀
@hozerhvac44065 жыл бұрын
Great work Ted. Charge looks good to me as well. Thanks for the tip as well for the furnace
@EnjoyCalculus3 ай бұрын
S9V2 notorious for inducer seal leaking right onto the board
@Brokentwobutton5 жыл бұрын
Completely agree on two stage cooling for low seer resi equipment. Only really useful running two equal zones. Dehu is best done with dedicated equipment or solving other problems.
@DonMoran-l9h9 ай бұрын
Love the channel. It is my go to before I call and bug you in person. Here trying to figure out how to increase fan speed on a Trane 80% , in fan only it is running on very low. Works fine in heat and cool. It is Pepe's house. In your old neighborhood. May be calling you..
@TedCookHVAC9 ай бұрын
The only way to speed the fan up is to add compressor. Meaning when the green only is energized, it runs at a very low speed usually 35 to 50%.
@TedCookHVAC9 ай бұрын
Send me the model number to the furnace. Sometimes there are circulation speed adjustments.
@DonMoran-l9h9 ай бұрын
Trane Serial 23481lpmgh@@TedCookHVAC If that is not right I will get it tomorrow. I am amazed you responded, you have to be busy as hell. I took his packet with all the info back to him today. The code is COF Component overload. Maybe the fan was not full stop when we set the fan speeds.
@zhinonghuang66794 жыл бұрын
Not sure you are right. It should connect to Y2 in furnace, otherwise the blower always run at slow speed (y1). Maybe different machines have different setting?
@throttlebottle59065 жыл бұрын
so that was your retrofits did the installers forget to RTFM? lol shouldn't the t-stat and condenser be on Y1 with jumper remaining from Y1 to O, nothing on Y2, then set any blower ramp delays through the board menu.
@dhinton81275 жыл бұрын
I thought you just wire to y1 and set in the control board that it is single stage, the outdoor tonnage and the cfm per ton.
@lornewelcher91155 жыл бұрын
Yep...that's exactly right. Have installed and serviced 100s of the s9v2s. Love them
@shawnd5675 жыл бұрын
Yeah my Goodman has little dip switches to alter the fan speed, I'm guessing you do that via those menu buttons in the center. So now the computer thinks y1 and y2 are being energized!? Probably fry the board.
@damonmcneal30005 жыл бұрын
That's exactly how we do it!
@amfmechanicbowlingcommunit50482 жыл бұрын
How do I test if my VFD it’s running at full speed? I know by fact that a degraded fan signal that results in the fan speed being lower that the board is requesting. For example, at fan only 50% fan signal should be 30 HZ on the VFD. At 100% fan signal (full cooling) the VFD should be running 60 hz. If you see something different, the board may need to be replaced.
@jrsmyth97615 жыл бұрын
Y1 or Y2 In my experience there is a limit for cfm/fan speed on each of these, but not sure how this particular unit works. Depending on max from each and size of outdoor unit, or dual stage, you connect to the appropriate terminal(s).
@drg424 Жыл бұрын
I'm with on the single , let the thing run cool the house down , shut off and save electrical cost , if u are that concerned about humidity ,they make dehumidifiers.
@Sashazur2 жыл бұрын
What could be causing my blower speed to fluctuate a lot but mostly run at very low speed during cooling season? This is a problem I’ve been having during a recent spell of hot weather, no issues otherwise since install 7 years ago. Usually turning the system from cool to off for several hours fixes the problem and then it’ll work fine again for a day or two. If I leave the system off but the fan on, it seems to blow at the expected medium speed.
@joshuaseaton45265 жыл бұрын
Only needs Y1 with a single stage thermostat.
@mattflorence35615 жыл бұрын
Good video Ted. Thank you for all the recommendations of what equipment you recommend pairing together.
@prebaned3 жыл бұрын
That's good for cool. How to make the blower speed run high on heat?
@EvesterGaming5 жыл бұрын
I just put one of these in yesterday longest part was programming the board for while checking static pressure. I love the height of this new furnace but thats about it.
@gerardonavarrogomez72893 жыл бұрын
One question and what can we check if the blower ecm motor not stop working????
@Marshallkhamou5 жыл бұрын
Why wouldn’t you leave a note on a panel when it was put in and initials of the installer or on a sticker with your company info
@mrgreen26465 жыл бұрын
I've had that same though for years. My only guess would be unlicensed installers or the company not wanting to take any liabilities.
@throttlebottle59065 жыл бұрын
most likely the builder has their own installers that does every home they build. chock full of shortcuts, nonsense and often right in the plan at architect level.
@sknight03915 жыл бұрын
Hey Ted, in the upper left-hand corner of that board there's a little square with an "FP" in it at the (3:00 min. mark) and it says "flame current" right above there. It looks like there are 2 little solder pin positions there. Is that where you take is that where you take the uA for the flame sensor reading at on that board?
@zacharypalczynski84505 жыл бұрын
Yes it is
@joeyjennings95483 жыл бұрын
dehumidification mode? yes yes.. its a residential area so on a turn invert the speed limit number.. 15 has become 51🏡🚘🏎 👍 airflow is the 1st place to start. clean coils & blower wheel collapsed vent line
@marioramirez67414 жыл бұрын
Where can I buy the pressure gauges you use?
@MrWontstopthefunk4 жыл бұрын
Any idea how to make this unit run dehum mode? Can i just get hunidistat and working?
@publicmail25 жыл бұрын
Anti DIY, if you were to replace a 3 ton single speed 13 SEER heat pump, ICP Heil, what today would you go with for best longevity and reasonably high SEER 16-20? Even considering a mini split cassettes with multi zones. Thx~
@throttlebottle59065 жыл бұрын
cross your fingers and pray to the almighty nonexistent hvac god of long equipment life :)) you should quickly arrive at my opinion about all equipment on the market........ today, tomorrow and handful of decades back ;)
@los2hot4994 жыл бұрын
So are you saying either get a single stage or go to a variable 18-20 seer unit? Isn't that a huge price difference? So 2stage to you has no real benefit over single? I ask because I'm replacing 2.5 ton 14 seer single stage unit soon sq 1,450 ft home. I think i would have to move up to a 3 ton unit to get any kind variable stage units.
@picklerix61624 жыл бұрын
According to many HVAC techs here on KZbin, the dual stage condensers are less reliable. If you check the AHRI documentation, the 18 SEER 5 ton dual stage condenser is not any more
@brentaudi93545 жыл бұрын
Why do so many builders put the dryer vent right next to the a/c condenser?
@throttlebottle59065 жыл бұрын
most likely specified in the building plans by the "stooge architect", so that all mechanical's and piping are at one location, that's seen the least.... nothing out front of house, nothing visible above roof-line/peak and all out the wall with least amount of windows. which is often narrow adjoining side yards, with a fence smashed between and poor airflow. shall I mention the homes all being too close together and neighbors having their noses up each others butts 24/7
@13ryanheartbreaker275 жыл бұрын
Is that not where they go?... maybe it just grew there like moss on a tree, dryer vents appear next to condenser.🤔
@kenthomas46683 жыл бұрын
@@13ryanheartbreaker27 Closest to coi as possible, last line of defence.
@97Napkins3 жыл бұрын
the installers didnt do anything but open the valves and go...the charge is right on due to short line set.
@skimask35 жыл бұрын
Correct .6 oz per foot. Itchy Mee-shee has a diff charge gang. Read the book cause the many circuits may change what we do.
@凌晨-l8g4 жыл бұрын
sir: my heat pump package ECM blower will only work when its fan is set to ON. In auto, it stops
@coolezum5 жыл бұрын
There is a good use @ reasonable cost for two stage cooling. When you have a two or three zone system this can be very efficient and affective.
@matthewgraham42752 жыл бұрын
Hi I like your video
@Brandon-to9vp4 жыл бұрын
2 stage beats single stage all the time, 2 stage cooling saves more electricity. Gas is cheap....
@RiceRiceBaby545 жыл бұрын
Good one Ted, thanks!
@geoffhoweth5 жыл бұрын
All this computer sh#@t makes me sick . But at the same time we Maint and HVAC guys have to understand how this stuff works. Great Video Ted 👍👍
@LmTeamWaxOffroad5 жыл бұрын
Thanks for the vid!
@TheWoodman0644 жыл бұрын
Here again!
@michaelhenderson62925 жыл бұрын
Looks good. Grommet missing on the right side of where float switch is going in. Just busting your chops bud. Lol
@JoseRodriguez-bu4tw Жыл бұрын
So what happened when you were a kid ? You can't just edit that part out you know second 15 bro.
@richardcox52464 жыл бұрын
Please speak up when you are recording yourself. When you mumble we can’t hear you a lot of us are sitting in our trucks on our downtime trying to learn more but there’s road noise around us. But thank you I appreciate your content.