@MrButuz
@MrButuz 11 ай бұрын
That wiring aint gonna cope with 40 amps continuous though so the fuse probably won't pop.
@tom18181
@tom18181 11 ай бұрын
Well if you look on though my videos you may see some changes.
@lawrencedavidson6195
@lawrencedavidson6195 Жыл бұрын
I love the use of a cutting board as the mounting plate for the CC and other stuff, it really adds to the décor of the build. Greetings from Jamaica.
@tom18181
@tom18181 Жыл бұрын
Ha ha yeah I liked it to but I got stuck in and re did the whole cabinet. You can see that in my latest videos
@lawrencedavidson6195
@lawrencedavidson6195 Жыл бұрын
@@tom18181 And i'm here thinking to re do mine and add a cutting board..lol
@tom18181
@tom18181 Жыл бұрын
@lawrencedavidson6195 Well. If you to , go for it. The main this is you have to be happy with how it looks
@Electronzap
@Electronzap 9 ай бұрын
Sounds good.
@stormer6364
@stormer6364 Жыл бұрын
Your video just popped up on my yt, thanks for sharing... A couple of possible improvements if you like, is the fuse should be close to the battery or your unswitched busbar whichever way you have connected the solar .. The second thing, it depends on the size of your solar array but blade fuses dont cut it on larger systems, its the constant current through them which is the issue, but if they're not getting warm at all then they will be fine, i generally install a circuit breaker on the pv side and whatever is most appropriate for the system on the battery side anl fuses or a switched breaker. although many dont recommend fuses on the pv side, its nice to be able to disconnect the panels if you're changing out controllers, batterys or working on the unswitched part of the system.
@tom18181
@tom18181 Жыл бұрын
Hello. Hay thanks for your info. Yep all of that understood. I have been completely rebuilding it all since the video you saw. If you subscribe to my channel you can see the next one come out in the near future. Let's just say it's light years ago that video lol
@tom18181
@tom18181 Жыл бұрын
kzbin.info/www/bejne/mJyti2qNpdh_h8U
@jamielourens4222
@jamielourens4222 Жыл бұрын
Where abouts on the van did u run the earth for the solar controller
@tom18181
@tom18181 Жыл бұрын
Hi there. That must be grounded to the Chassis. The best way to understand it, is it is not just another negative. So many people do that. Victron would never put an earth screw on for it to just be another negative. Any earth on Victron gear must go to the frame. Cheers
Victron charger and Inverter setup under way
8:41
WorkShop Fun!
Рет қаралды 6 М.
DCS battery! Youtuber Sued for Reviewing this Battery?! Let's Test It!
19:44
DIY Solar Power with Will Prowse
Рет қаралды 667 М.
Smart Meter Disaster!!
16:33
Rygol Electrical and Renewables Bristol
Рет қаралды 443 М.
How to install the Victron Energy SmartShunt IP65
5:14
Victron Energy
Рет қаралды 146 М.
Victron Solar Controller App Basics
13:19
Travels with Delaney
Рет қаралды 142 М.
I NEARLY SET MY CAR ON FIRE
9:16
Joe Murray
Рет қаралды 13 М.
Sailing Vlog 30 Victron 100/30 Solar Charger Upgrade
8:49
The Foster Journey
Рет қаралды 2 М.
Charge Lithium Batteries correctly (LiFePO4)
37:33
Clark's Adventure
Рет қаралды 22 М.
Victron MPPT controller, potting hack and hidden fuse
12:48
Andy Reynolds
Рет қаралды 19 М.
Completed victron system
17:59
WorkShop Fun!
Рет қаралды 731