Victron SmartShunt settings explained in detail

  Рет қаралды 32,931

Offgrid Power Solutions

Offgrid Power Solutions

Күн бұрын

Sign up for our detailed SmartShunt settings PDF here: geni.us/PDF-VictronSmartShunt
Learn how to build your own LiFePO4 battery here: geni.us/DIY-LiFePO4
Sign up to our email list for exclusive tips & discounts: geni.us/offgrid-email
In this video, we're going to take you through a very detailed explanation of all of the Victron SmartShunt settings. These SmartShunts are a great piece of kit and a great addition to your electrical setup, so we want to make sure that your settings are giving you the best results!
If you’re building an electrical system and need help, get in touch: geni.us/offgrid-contact
If you're not sure where to start with your Offgrid Power set-up, book a consult call with us: geni.us/offgrid-consult
--------------------------------------------------------------------------------------------------------------------
►▷ SUBSCRIBE TO OUR OFFGRID POWER KZbin CHANNEL: geni.us/offgrid
►▷ SUBSCRIBE TO OUR OFFGRID WORKSHOP KZbin CHANNEL: geni.us/offgridworkshop
►▷WATCH OUR LATEST OFFGRID POWER VIDEO: geni.us/offgrid-latest
►▷WATCH OUR LATEST OFFGRID WORKSHOP VIDEO: geni.us/OffgridWorkshop-Latest
►▷ SUBSCRIBE TO OUR EMAIL LIST: geni.us/offgrid-email
- FOLLOW US ON SOCIALS -
Instagram: / offgrid_power
TikTok: vm.tiktok.com/ZMejrWUS8/
Facebook: geni.us/offgrid-fb
- CONNECT WITH NIGEL -
Instagram: / nigelivy
Twitter: / nigelivy
Facebook: / nigelivyphoto
TikTok: vm.tiktok.com/JRBJWry/
Snapchat: / nigelivy
- CONNECT WITH ROGER -
Instagram: / roger_ivy
- GEAR -
Main Camera: geni.us/NigelsFavCam
Most Used Lens: geni.us/NigelsGenLens
Favourite Portrait Lens: geni.us/NigelsFavLens
Other Favourite Lens: geni.us/NigelsOtherLens
Favourite BIG Lens: geni.us/NigelsLongLens
Widest Lens: geni.us/NigelsWideLens
Drone: geni.us/NigelsFavDrone
Gimbal: geni.us/NigelsFavGimbal
Mic: geni.us/NigelsFavMic
Lav Mic: geni.us/NigelsFavLav
Favourite Little Camera: geni.us/NigelsVlogCam
Tripod Thing: geni.us/NigelsTripodThing
SSD Lifesaver: geni.us/NigelsFavSSD
Favourite Mini Audio Recorder: geni.us/NigelsFavAudio
BIG Audio Recorder: geni.us/NigelsMainAudio
Favourite Camera Bag: geni.us/NigelsIOtherCamBag
Second Favourite Camera Bag: geni.us/NigelsFavCamBag
Favourite Camera Strap: geni.us/NigelsFavCamStrap
Favourite Tripod: geni.us/NigelsFavTripod
ND Filter: geni.us/NigelsFavND
360 Camera: geni.us/NigelsFav360
SD Cards: geni.us/NigelsFavSD
** Some of the links on this page contain affiliate links that generate a small commission for us if you click them.
- MUSIC -
Musicbed SyncID: MB01BTBLFFUJGFH
All music used in this video is licensed by Musicbed.com.
If you’d like to get a free month of Musicbed, use this link to sign up: www.musicbed.com/invite/vF4lN
#offgridpower #vanlife #solarpower

Пікірлер: 58
@CoddiwomplewiththeWyatts
@CoddiwomplewiththeWyatts 10 ай бұрын
You can not imagine how many people like me are out there trying to set up their smart shunt and have zero clue what we are doing. I am currently on the road traveling long term with my family and needed this information desperately to make sure we are using our batteries wisely. Thank you so much. Everything makes sense now. You have a new fan!
@DavidRea2710
@DavidRea2710 9 ай бұрын
Thank you so much. Got my shunt installed on my sail boat and now finally set up
@stevelee6858
@stevelee6858 9 ай бұрын
I’m about to fit a SmartShunt to my VW camper and this 😊is by far the best video I’ve seen about it. Thank you!
@zummerzetwoodsman1067
@zummerzetwoodsman1067 Жыл бұрын
Thank you. Sat in my van and coped all your advised settings. Very informative video.
@offgrid_power
@offgrid_power Жыл бұрын
Glad it helped!
@ZiggZagg11
@ZiggZagg11 6 ай бұрын
Thank you... I have been using a Victron Shunt for several years and I get 100% reading when I know it is not forever, but I had no idea how to fix it... 😊
@Dalgety4
@Dalgety4 4 ай бұрын
I have plainly been using the wrong settings for my 120ah Lifepo4 which explains the fact that I did not have the 60% SOC while van was off the road that I thought I had. Going with your advice tomorrow. Brilliantly explained thank you.
@gfaucett
@gfaucett Ай бұрын
Best description ever! Thank you.
@craiglouw4057
@craiglouw4057 8 ай бұрын
I am so glad I found your channel 💪 Dankie Bru 💪
@jamietoms6621
@jamietoms6621 10 ай бұрын
That was epic. Well eplained .Thank you. Subscribed
@cloversdaddy
@cloversdaddy 11 ай бұрын
Excellent video! Victron should hire you. Thanks so much for the answers that Victron themselves seem unable to provide.
@offgrid_power
@offgrid_power 11 ай бұрын
Glad it was helpful!
@noelburns4512
@noelburns4512 3 ай бұрын
Great video I have 48 V Lifepo4 system I was having trouble trying to determine the charge voltage for the Victron shunt. I couldn't work out why the system cut out early but with the help of your video my charge voltage was set too low Thanks great info
@beentheredonethat6219
@beentheredonethat6219 6 ай бұрын
Thank you! My setting had gotten off by 18%. I re-synchronize them. Now that match what the batteries say they are at!
@eugenedvorak334
@eugenedvorak334 5 ай бұрын
Thank you for the very helpful information.
@user-cb6ok6yg9i
@user-cb6ok6yg9i 4 ай бұрын
Thanks for your help! You’re the best
@mirendorff
@mirendorff 7 ай бұрын
very good explained, thank you
@offgrid_power
@offgrid_power 7 ай бұрын
Glad it was helpful!
@robbypro3370
@robbypro3370 3 ай бұрын
Great video. Thanks
@RustyGlovebox
@RustyGlovebox 4 ай бұрын
Thank you so much for all this helpful information. New Subscriber 🎉🎉
@offgrid_power
@offgrid_power 4 ай бұрын
Glad it was helpful!
@matthewknight5641
@matthewknight5641 Жыл бұрын
I'd loved to have gotten all victron components when I was shopping for everything. At the time I was new to solar and couldn't justify the price in my mind. Now I see so many features victron provides that I would like to have now. They are expensive and complicated but they are unmatched in so many areas.
@offgrid_power
@offgrid_power Жыл бұрын
Yeah, that's so true.
@smt1992
@smt1992 7 ай бұрын
On god I love mine
@Mr1999tora
@Mr1999tora 28 күн бұрын
Video davvero molto interessante, l'ho seguito con attenzione, grazie.
@radulazar8056
@radulazar8056 2 ай бұрын
Hello! A very good tutorial! Thank you! Do you have any idea how to set a maximum load limit? For example 90% or 95%, to protect the battery?
@jasonbillington3923
@jasonbillington3923 4 ай бұрын
Thank you
@przemek868
@przemek868 3 ай бұрын
Great video, best explanation i've seen on YT, could You do same guide for Multiplus II?
@robertnasser9937
@robertnasser9937 4 ай бұрын
Very very nice
@offgrid_power
@offgrid_power 4 ай бұрын
Thanks!
@cdonuts7335
@cdonuts7335 6 ай бұрын
Amazed how many people don't read the manual! It's all there!! From Page 22 on is the most helpful. Even so called experts don't get it 100% . Discharge floor is used for the time remaining calculation and alarms, it doesn't disconnect anything that's low voltage disconnects job!
@TraconWizard
@TraconWizard 6 ай бұрын
What manual? There's 2 pages with the smart shunt.
@cdonuts7335
@cdonuts7335 5 ай бұрын
@@TraconWizard haha and you call yourself a wizard!! That's the quick start guide! If I had a dollar for every time I've had to explain that ! 😂 www.victronenergy.com/upload/documents/SmartShunt/9172-Manual_BMV_and_SmartShunt-pdf-en.pdf
@AlanBrown-uh1os
@AlanBrown-uh1os 3 күн бұрын
At 6:24 did you mean to say float voltage? That would make more sense to me. You stated bulk voltage… Thanks!
@user-kd6qj8kz7n
@user-kd6qj8kz7n 9 ай бұрын
Very good information thank you I’m wondering if the shunt you are referring to is the 500 amp size.
@offgrid_power
@offgrid_power 9 ай бұрын
Yes, we were using the 500A version in this video.
@comarshlunan8592
@comarshlunan8592 6 ай бұрын
Hello good afternoon, thanks for sharing this video… I have 8. 12v valve regulated lead acid batteries to make up my 48v. What would you recommend for my charged voltage?
@haydenwatson7987
@haydenwatson7987 3 ай бұрын
You can add me to those few who have gone bigger than normal. I have two 460Ah LFP's for 920Ah. I had planned on going with a DYI build with 16 280Ah cells in either a couple of 2p4s configurations or by paralleling four 4s pack for a total of 1120Ah. All of these would fit into the battery tray made for (6) golf cart batteries.
@barryswatman2398
@barryswatman2398 Ай бұрын
I am confused on your Peukert's exponent info, I think this is used to calculate (project) the delivered capacity based on the Discharge rate not charge acceptance efficiency. Just curious what you were intending on this one.
@lindaferguson593
@lindaferguson593 11 ай бұрын
I have 2 banks of 6 eg4 batteries (not LL). Needing a wiring diagram to connect my 500A smart shunt to them. Banks are parallel to parallel. Pairing off on th😊e two negatives. Thanks.
@jeffpurdy2347
@jeffpurdy2347 6 ай бұрын
Subscribed, but never got the PDF 😢. Correction, it came in my email! Thank you!
@stoptheirlies
@stoptheirlies 6 ай бұрын
Hi Rog, good video thanks, I am a bit concerned about the Battery capacity setting though, you need to be clear about series and parallel, 280 x 16 like I have in a 48 volt system is just 280AH as they are in series to make 48 volt, a 12 volt 280 would be 280 but if you have two in parallel then 560, so in parallel add them, but in series dont, what you say is not really clear. Bob
@georgeiredale9397
@georgeiredale9397 4 ай бұрын
Exactly my thought, considering they are totally different.
@jw228w
@jw228w 4 ай бұрын
offgrid have a question re my battery charger leads and midpoint connection to smart shunt.cant find this in viltron manga..should I keep charger leads as is going to each battery, or connect as a load, with each positive lead going to first battery, and each negative going to load side of shunt?seems like keeping as is would be the best way? thanks John
@EdJZatta
@EdJZatta 4 ай бұрын
When should you synchronize to 100% SOA?
@andyh8239
@andyh8239 3 ай бұрын
Current Threshold 0.1A A solar charge controller and shunt draw about 0.03A Does the system account for idle draw? Only if you lower the threshold to below 0.03 ?
@fazza6777
@fazza6777 2 ай бұрын
My MPPT charger states that absorption stops at 1amp(battery full). So would my tail current be 1% (1.2 amps) as I have a 120ah battery?
@HSKY412
@HSKY412 5 ай бұрын
The official Victron manual is written very poorly. It says "The charged voltage parameter should be set to 0.2V or 0.3V below the float voltage of the charger." My CTEK D250SE charger has a float voltage of 13.3V for lithium. So according to Victron, I should have my Charged Voltage set to 13.1V. The manual doesn't give any advice for tail current or charged detection time. Definitely not consumer friendly. Thanks for doing the video that victron should have done themselves.
@santiagoescalambre4738
@santiagoescalambre4738 2 ай бұрын
I have 2 100 amps batteries parallel connections on my 2 100 watts solar panels for my backyard lights how is VICTRON SMART SHUNT 500A CONNECTIONS ? THANKS IN ADVANCE
@JMX246
@JMX246 7 ай бұрын
Thanks for posting - do you have a video on the IPS65 120/15 Victron Charger ?
@aussiewonderer
@aussiewonderer 4 ай бұрын
What should my battery capacity be if i have 2x 6vx200ah in series with each other and in parallel with 2x 6vx200ah series?
@LordOneHoop
@LordOneHoop Жыл бұрын
Thanks. Very good information.
@sjochse
@sjochse 7 ай бұрын
Hi. Can you make a short video where you have two smartshunts with their own separate batterybank. Each of them with one or more mppt. And show How to correctly add all the units to a bluetooth network. Then add a globallink and connect all units via bluetooth only. Explain the differences between System Voltage, Gateway Voltage, and each SmartShunt Voltage. Can VRM indeed handle this? Last But also important. Install the globallink first with no connected units. Does it stay connected for 8 hours straight? After connecting all units, Does it stay connected for 8 hours straight? Add a communication alarm set to 60. And turn the relay to Closed. If you can add some kind of logger to the relay port that would be useful as this will show if, when and How often the globallink has restarted during these tests. I have had issues no one can solve and hope that you can give it a go. Many users have the same issue with abnormal interrupts and restarts.
@jime9305
@jime9305 4 ай бұрын
Amp hours are not necessarily determined by the number of batteries you have but rather by the battery configuration....if you have two 50ah -12v batteries in series you still have a 50ah battery, it's just a 24v - 50ah battery now. Something I thought needed to be made clear after watching just the beginning of your video...statements like that cause confusion for viewers.
@ovieoyegwa6153
@ovieoyegwa6153 8 ай бұрын
For the total battery capacity. You didn't mention what type of connection done, Either series or parallel. If series, the total capacity of all batteries connected will the total of one battery(280AH). If connected in parallel, the total battery capacity will be the sum of all batteries which is 1120AH.
@lijimbu6338
@lijimbu6338 7 ай бұрын
Looking at the charged voltage of 14.0V on his screen, it’s obviously a parallel setup connection. However, he may have made it a bit more clearer.
@mattym00
@mattym00 6 ай бұрын
I came to make the same comment. Well done explaining it for those who may be new to this it is an important distinction.
@M.K.G1994
@M.K.G1994 2 ай бұрын
Great video. Thanks a lot
Victron Orion-Tr Smart DC-DC Charger settings explained in detail
10:52
Offgrid Power Solutions
Рет қаралды 24 М.
DELETE TOXICITY = 5 LEGENDARY STARR DROPS!
02:20
Brawl Stars
Рет қаралды 17 МЛН
UFC Vegas 93 : Алмабаев VS Джонсон
02:01
Setanta Sports UFC
Рет қаралды 174 М.
Super gymnastics 😍🫣
00:15
Lexa_Merin
Рет қаралды 96 МЛН
I Built a Shelter House For myself and Сat🐱📦🏠
00:35
TooTool
Рет қаралды 34 МЛН
Victron 500A SmartShunt Battery Monitor Install, Walkthrough & Review
15:08
VIctron Smart shunt settings for LiFePO4~Like being back in school, but MORE FUN!
15:36
Installing Victron BMV 712 Battery Monitor
5:26
Inverter Service Center
Рет қаралды 13 М.
Sizing an MPPT Charge Controller [Basics]
8:57
Offgrid Power Solutions
Рет қаралды 11 М.
How To Wire & Program a Victron SmartShunt for LiFePO4 Batteries 🔋
7:29
Current Connected
Рет қаралды 125 М.
Victron shunt battery monitor setup & programming!
15:32
RV Solar Concepts
Рет қаралды 9 М.
What Is the Difference Between a Battery Monitor and a Smart Shunt?
6:03
Pacific Yacht Systems
Рет қаралды 35 М.
Victron Solar Controller App Basics
13:19
Travels with Delaney
Рет қаралды 132 М.
VICTRON SMART SHUNT -smart enough?
8:20
DTSquared
Рет қаралды 48 М.
DELETE TOXICITY = 5 LEGENDARY STARR DROPS!
02:20
Brawl Stars
Рет қаралды 17 МЛН