Voltage Unbalance | Current Unbalance | Causes of Voltage unbalance | Motor overheating | Hindi

  Рет қаралды 44,270

Electrical With Abhishek Joshi

Electrical With Abhishek Joshi

Күн бұрын

Queries Solved:
1. What is voltage unbalance.
2. Causes of voltage unbalance.
3. Effect of Voltage unbalance.
4. Voltage unbalance in Electrical System.
5. What is current unbalance.
6. Causes of current unbalance.
7. Effect of Current unbalance.
8. Current unbalance in Electrical System.
9. Motor overheating problem.
10. Motor Failure.
Hello Friends in this video we discussed about the causes and effects of voltage unbalance and current unbalance in the simplest way possible.
About Channel:
In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
#VoltageUnbalance
#CurrentUnbalance
Kindly Subscribe.
Thank you..

Пікірлер: 101
@manoranjan4598
@manoranjan4598 Жыл бұрын
Sir aapka video dekhane se bahut confidence aata hai
@rajulalbareth3717
@rajulalbareth3717 8 ай бұрын
Bahut badhiya jankari
@dineshprajapati-k7h
@dineshprajapati-k7h 8 ай бұрын
Bohht hi achhi jaankari ❤️❤️❤️❤️
@arunsundaramoorthi8774
@arunsundaramoorthi8774 4 жыл бұрын
Clearly mentioned that loose connection and poor contact may be one of the reason for voltage unbalance. Thanks. What is unbalance load and whether it may result for voltage and current unbalances. By sharing the load equally did voltage and current unbalance can rectified, kindly explain.
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@javeedhvactechnician7760
@javeedhvactechnician7760 11 ай бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=VkSs1UjswAuENgph
@vvikash87
@vvikash87 Жыл бұрын
Very Nice..Plz explain what is the reason behind to take unbalance current when we run a motor on no load???? ( we are facing the same when we installed a new motor (Blower motor 110kw, showing no load current as 40,56 ,45..in RYB)
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@javeedhvactechnician7760
@javeedhvactechnician7760 11 ай бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=VkSs1UjswAuENgph
@aarunangshu4649
@aarunangshu4649 2 ай бұрын
Sir what is the current difference is acceptable in three phase motor???
@Abhishek-zx4wy
@Abhishek-zx4wy 2 ай бұрын
±10%
@RajeevSainielectricals
@RajeevSainielectricals 3 жыл бұрын
dil se solute sir aapko..
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Thank you Rajeev..🙏
@Creativedimag10M
@Creativedimag10M 2 жыл бұрын
Explanation with notes then this Vdo is more popular to other 🙏
@javeedhvactechnician7760
@javeedhvactechnician7760 11 ай бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=VkSs1UjswAuENgph
@kailashka824
@kailashka824 Жыл бұрын
very informative.
@Rajesh-me6nn
@Rajesh-me6nn 10 ай бұрын
Sir hamare plant me 200 kw ki 4 motor hai jiska ek lead hamesa melt ho jata hai ek ko chod ke sab me VFD laga hai par lead melt hone ke baad bhi VFD trip nahi hota aur ye problem bar bar aati hai ab hamko har 10 days me terminal titness karna padta hai aur is plant ha voltage unbalance hai par kya kare kuch samaj nahi aa Raha hai
@Techatul
@Techatul 4 жыл бұрын
Very informative video Abhishek ji...
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Thank you Atul...
@akashsrivastava6248
@akashsrivastava6248 4 жыл бұрын
Sir please solar pe video banayiye
@suvendukar7947
@suvendukar7947 2 жыл бұрын
To know details about harmonic in power plant
@binodbihan1620
@binodbihan1620 3 жыл бұрын
Thanks so much better
@satishshiudkar7954
@satishshiudkar7954 4 жыл бұрын
Hi sir, Plc interlock connnection kaise pahchane/kaise samje starting mai
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Satish, ye to aapko apne senior se seekhna padega. Aise batane se samajhme aana mushkil hai.
@omkarthakur8414
@omkarthakur8414 2 жыл бұрын
Or sir, voltage unbalance ki vajah se lod dalne per motor dhire dhire band ho jayegi kya
@HarishKumar-fh1ii
@HarishKumar-fh1ii 11 ай бұрын
Thanks 👍
@Skallvideos-hp4ww
@Skallvideos-hp4ww 3 жыл бұрын
Sir transformer bhi naya hai lekin voltage unbalance hai ry 425v, rb 418v, by415 volt hai keya kare upay batayen
@narendrasingh9157
@narendrasingh9157 3 жыл бұрын
Good Learning
@urmilasah3935
@urmilasah3935 2 жыл бұрын
Good morning sir Daily reading se unit 1.00mwh increase ho rha h dono incomer me Aisa kyu
@Parihar1986
@Parihar1986 3 жыл бұрын
Sir apni industry m compressor ki ek motor k ek phase m jayda current le rehi h current ki limit per phase se double h
@omkarthakur8414
@omkarthakur8414 2 жыл бұрын
Sir , voltage unbalance huwa to motor vibration ke sath motor jarurat se jada speed legi kya
@dharmveer2824
@dharmveer2824 4 жыл бұрын
Thanks for informative video's, it's help lot to understand things practically.
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@hamzanisar9409
@hamzanisar9409 3 жыл бұрын
Ham Voltage unbalanced ke calaculation Line to Line voltage ke consider krty hn ya Line to neutral.
@VikramSingh-gp9hj
@VikramSingh-gp9hj 3 жыл бұрын
Helo sir jese three phase altineter hota hai uski phase ki capacity h load ki ussey load uper na de ussey nichey load ho hamre pass to balance uper niche kar sakte hai jese 1 phase ki capity 50 ampire hai to teeno phase ki power 150 ampire ho gyi To 1 phase par hum 40 ampire load daal diya 2 phase par 30 ampire 3 phase par 20 ampire Ye to koi dikat nhi h kya
@keshavkulkarni5553
@keshavkulkarni5553 4 жыл бұрын
Thanks brother☺️☺️🙏🙏
@ashoktiwari2159
@ashoktiwari2159 4 жыл бұрын
Sir plz make a described vedio on steam turbine
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Okay Ashok...
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Also watch playlist for videos related to Drawing, Calculation, Motor, Transformer, Power Factor Correction and many more...
@nikhilsreekumar5744
@nikhilsreekumar5744 4 жыл бұрын
Sir please make a video on the topic MV drive
@kunjanpatel6962
@kunjanpatel6962 2 жыл бұрын
3ph me Ek hi phase me voltage variation hone kya reason hota he ?
@akshaykumbhar788
@akshaykumbhar788 2 жыл бұрын
Hi sir, main ek electric kam karne ke liye society me gaya tha. Vahape mseb government ka meter se aane vale three phase voltage me ek phase ka voltage kam hai. To ye kyo hota hai.or uska Solutions hya hai. R phase 214 B phase 240 Y phase 240 all vtg with reference to nutral. plz reply as soon as possible
@samvedna22
@samvedna22 4 жыл бұрын
Nice video
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Thank you...
@panditvishal5451
@panditvishal5451 2 жыл бұрын
Superb topic abhishek g how much unbalanced current is allowed In normal operating motor also how much operating temp DE and NDe side temp allowed
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@pardeeppsiingh7068
@pardeeppsiingh7068 4 жыл бұрын
Very nice
@hamzanisar9409
@hamzanisar9409 3 жыл бұрын
Sir voltage unbalanced ka jo standard ha ky 2% allow ha ya standard with respect to the Line to line voltage ha ya line to neutral
@archive9994
@archive9994 4 жыл бұрын
Thank you sir
@souvikdey3918
@souvikdey3918 4 жыл бұрын
Great information I also work in a maintenance dept. It will be very beneficial for me.
@pandithalgare
@pandithalgare 3 жыл бұрын
तुम भी एक चैनल बनाकर विडिओ डालो
@souvikdey3918
@souvikdey3918 3 жыл бұрын
@@pandithalgare video dalne ki iccha bohot hai but time manage nahi ho pata hai.
@pandithalgare
@pandithalgare 3 жыл бұрын
Try करो
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@chiranjivikatuwal2232
@chiranjivikatuwal2232 3 жыл бұрын
Thank uh so much 💞💞💞
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Most welcome Chiranjivi..
@amaanahmad521
@amaanahmad521 4 жыл бұрын
Make a vedio on lock out relay
@CulturalyCurious
@CulturalyCurious 4 жыл бұрын
Well done 👍
@easysolutions5180
@easysolutions5180 4 жыл бұрын
Sir aap with practical video banaiye
@arunjoshi2089
@arunjoshi2089 4 жыл бұрын
Nicely explained.👍
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@dineshtusia968
@dineshtusia968 4 жыл бұрын
Good👍 information sir. 1 question sir:- mostly tersory winding used in ∆-∆ connection why❓ स्टार स्टार कनेक्शन में Megnatising current flow नहीं होती है क्योंकि star connection में मैग्नेटाइजिंग current Sinusodial form में होती है🤔🤔 plz reply sir
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@p.p.4192
@p.p.4192 2 жыл бұрын
Voltage balance he motor starts karne ke bat current unbalance hota he starter trip hota he.. kya karan ho sakata he
@niteshkumar1738
@niteshkumar1738 3 жыл бұрын
In soft starter panel of 650kw, i found current unbalance even all phase voltage are balanced ? What to do for current balancing?
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Check motor coil resistance.
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@maroofalikhan6210
@maroofalikhan6210 3 жыл бұрын
Nice
@mansoor2377
@mansoor2377 2 жыл бұрын
Motor inter turn problems also cause for unbalamcing
@gopalkhamkar2849
@gopalkhamkar2849 4 жыл бұрын
During DG set Running not found current unbalanced. Only express line we face issue
@Shivamkumar-kl1ri
@Shivamkumar-kl1ri 4 жыл бұрын
Wear and tear ka mtlb kya hota hai??
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Wear and tear mein toot-foot jana
@Shivamkumar-kl1ri
@Shivamkumar-kl1ri 4 жыл бұрын
Oo thanks sir.
@archive9994
@archive9994 4 жыл бұрын
Sir ring main unit UPS Video please
@chandrashekhar4951
@chandrashekhar4951 3 жыл бұрын
Sir what current and voltage percentage permissible in motor pls inform me
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@kdkanishk
@kdkanishk 3 жыл бұрын
Kya current unbalance matlab fault hota hai kya?
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Haan... Agar system ka current unbalance hai to system trip ho jata hai.
@learnbyshiva725
@learnbyshiva725 4 жыл бұрын
Thanks sir
@sarfarazkhan5760
@sarfarazkhan5760 3 жыл бұрын
جناب محترم وولٹیج اور کرنٹ کا بیلنس کس طرح برابر کرے گا شکریہ جناب
@Techatul
@Techatul 3 жыл бұрын
Sir...I checked vfd incoming current that's value is 10 amps...but when checked vfd outgoing (motor side) then value shows 30 amps... That means vfd saving power...but my question is...what phenomenon happen in vfd that's reason outgoing current is greater than incoming current.
@romitshirguppi3964
@romitshirguppi3964 3 жыл бұрын
No there is a phenomenon. Output voltage is less than supply voltage hence total power remains same. Remember energy can neither b created nor b destroyed.
@sanjeevjasrotia3104
@sanjeevjasrotia3104 2 жыл бұрын
Sir if the system as unblanced current R=318 amp Y=315 amp B=319 amp In 3 phase syetem If someone says that give ampere load of the system, then which of these R Y B loads we will give?
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@sindhuupadhyay6999
@sindhuupadhyay6999 2 жыл бұрын
What will be happened when we touch the one phase of 4.5MVA 33/6.6 kv DY11 transformer
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@nikhildalal979
@nikhildalal979 3 жыл бұрын
नमस्कार सर मैं एक छोटा सा किसान हूं और मेरा 3 फेस मोटर ट्यूबवेल पर 18-19 एम्पियर पर चलता है और कई बार चलते चलते अचानक से वाईब्रेट करके बंद जाता है और मेरा आनलाइन आपरेटर ओवरलोड की वजह से बंद होना बता देता है और दोबारा से फिर चालू करना पड़ता है। इसका क्या समाधान हो सकता है। क्या ये लो वोल्टेज से भी हो जाता है जैसे 360 के आसपास? या कोई ओर दिक्कत हो सकती है
@javeedhvactechnician7760
@javeedhvactechnician7760 11 ай бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=VkSs1UjswAuENgph
@ashutoshsharma9066
@ashutoshsharma9066 4 жыл бұрын
Does voltage imbalance causes poor power factor ?
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@azharnaqvi553
@azharnaqvi553 3 жыл бұрын
When i was start motor with VFD then motor get start but not achived full frequency and also in some motor i was set frequency 50hz but it was running at 7-8hz then motor get stop then running at 7-8hz then stop. What is this problem? Plz get me answer....
@romitshirguppi3964
@romitshirguppi3964 3 жыл бұрын
Can u give me d details of Ur problem so that I can help u out
@vishalshah5913
@vishalshah5913 3 жыл бұрын
What is the reason for current unbalance is 6 to 8 times voltage unbalance?
@javeedhvactechnician7760
@javeedhvactechnician7760 Жыл бұрын
kzbin.info/www/bejne/jqimmHuOm9ZnnJosi=p5JIKNj90IDwKJlX
@abduljabir6213
@abduljabir6213 4 жыл бұрын
🙏🙏
@imteyazansari3447
@imteyazansari3447 2 жыл бұрын
Dhire dhire boliye smjh nAhi aatA
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 2 жыл бұрын
Aap mere bolne ki speed ko youtube pe apne hisab se adjust kar sakte hai.
@varadharajanelectricalengi5954
@varadharajanelectricalengi5954 3 жыл бұрын
🙄🌎🌏🐸😲🙏
@adiyottiludayakumar810
@adiyottiludayakumar810 3 жыл бұрын
Repeat telling v unbalanced c unbalanced nothing valuable
Motor Current Unbalance | Why Motor Burnt | How to Solve Motor Unbalance current problem
6:27
Electrical Motor Failure| Why Motor Burn| Motor Protection explained | Hindi
7:59
Electrical With Abhishek Joshi
Рет қаралды 17 М.
УДИВИЛ ВСЕХ СВОИМ УХОДОМ!😳 #shorts
00:49
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 45 МЛН
Which connection is preferred star or Delta| Star Connection vs Delta Connection | Hindi
7:59
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 1 МЛН
3 phase Unbalanced Electrical System Power Calculation KW and KWH
9:01
Deepakkumar Yadav
Рет қаралды 635 М.
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,8 МЛН
Why we Use 3ph? Why Not 4ph, 5ph??| Why Transmission done with 3ph| 1ph vs 3ph System
9:01
Electrical With Abhishek Joshi
Рет қаралды 30 М.
УДИВИЛ ВСЕХ СВОИМ УХОДОМ!😳 #shorts
00:49