Today I troubleshoot and repair a walk-in in cooler that isn't maintaining temp
Please consider subscribing to my channel and follow me below
Social Media
Facebook www.facebook.c...
Instagram / curioushvacguy
For any inquiries please contact me at
curioushvacguy@gmail.com

Пікірлер: 39
@amonroe812
@amonroe812 4 жыл бұрын
Your Tech Tips are priceless, my favorite so far "avoid being a hack" wish everyone lived by that motto!
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
If everyone loved by that rule the world would be a better place- I'm not perfect but it boils down to not taking the path of least resistance in life
@MRICE-qe4sv
@MRICE-qe4sv 5 жыл бұрын
Really enjoy the videos. I like that roll of nut drivers. Not sure if you realized but that defrost clock is not doing anything. They come pre wired with L1 and L2 to them but your 4 terminal was not hooked up. Also those universal motors are all I carry anymore. Work great.
@hg2.
@hg2. 3 жыл бұрын
Lot of nuances and refreshers - thanks! Well done.
@tunaman2200
@tunaman2200 3 жыл бұрын
Thanks for the tip about the defrost clock!
@ralphruiz1066
@ralphruiz1066 2 жыл бұрын
Thank you for all your videos I’m a new tech out in the field and your videos really help me out a lot. First video I saw and you made me a subscriber.
@edwardgaddis8333
@edwardgaddis8333 4 жыл бұрын
Funny same Russel model got me with same problem on Emer.hours this summer. HP limit tripped right fan nothing. Found loose wire. Motor still good. Those Fasco motors are life savers for sure.
@Farm_fab
@Farm_fab 4 жыл бұрын
A trick that I learned years ago is to fold over the end of the tape onto itself so that you can remove the tape more easily. This makes a "pull tab." I'm aware that the tape may dry out, and when it does, you'll know it's also time to change it. This is also good for techs that come behind you.
@HvacFl
@HvacFl 3 жыл бұрын
Have you ever cut the wires to length and leave a service loop, eliminates all that excess wire and looks super clean but that’s knit picking 🤣 good work man, awesome videos!
@rookierefrigeration4357
@rookierefrigeration4357 4 жыл бұрын
I like those motors. Good job bro. Those units are good to work on.
@davejohnsonnola2758
@davejohnsonnola2758 5 жыл бұрын
Thanks for taking us along for the ride and walking thru some of the basics. Looking forward to more from you.
@BigHuff-sq9hb
@BigHuff-sq9hb 3 жыл бұрын
These lessons are great.
@andymaurer7972
@andymaurer7972 4 жыл бұрын
You are a smart guy you take your time with things and that is the best what i like is you don't rush through things that is awesome you take your time with things. One thing i notice when you connected the motor to the other motor its up to you i would of put a little dielectric grease on the end of it so no rain or anything gets in it
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
Thanks - thats a very good point, Ive never honestly thought about that but it makes sense
@jasonjohnsonHVAC
@jasonjohnsonHVAC 3 жыл бұрын
Funniest man on the HVAC OT show.
@davejohnsonnola2758
@davejohnsonnola2758 5 жыл бұрын
This vid came up in a sequence. Even though I had seen it before, appreciated some of the basic tips imparted. ¡Gracias!
@johnnyfair1005
@johnnyfair1005 4 жыл бұрын
Love the videos man, only criticism would be to not extend the wires of the motor unless they do not reach without it. But if ur going to do it, the way u did it with the tape is the right way to do it. Keep the videos coming brother.
@actechformallyyomama746
@actechformallyyomama746 4 жыл бұрын
It’s either clean like new or it is dirty. It’s that simple. Here is an amazing fact. A build up of .042” of dirt on either coil can reduce efficiency by 21%. This information is from the EPA. I rinse my condenser coil every light bill and change my filter.
@Tjita1
@Tjita1 4 жыл бұрын
Condenser on my moms car looked clean, but it didn't cool properly. Cleaned it with a foaming degreaser, head pressure dropped from 220 psi to 170 and car is now ice cold, in fact it was so dirty it turns out it needs a squirt more of gas now, to run at proper pressures.
@actechformallyyomama746
@actechformallyyomama746 4 жыл бұрын
I had micro coils under a dryer vent at a retirement home. The coils didn’t look that dirty. I hosed them off with water and the entire length of slab about 15’ was covered in lint. This was 3 condenser coils. It’s amazing how they don’t look bad.
@ramonjr1000
@ramonjr1000 5 жыл бұрын
What is that defrost timer doing? I believe it’s Not wired right from this view. Peace.
@gregbowman3598
@gregbowman3598 4 жыл бұрын
Good video brother , use same universal motor enjoy your videos
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
Thanks
@hvachvac-rl7nv
@hvachvac-rl7nv 5 жыл бұрын
Were did u get the roll of nut driver bits and handle
@ronaldzeigler9057
@ronaldzeigler9057 3 жыл бұрын
Boy you are right about the nuts.
@nastyhvacr
@nastyhvacr 3 жыл бұрын
Pat “ the curious KZbin viewer” when you are putting motor on the bracket, what sort of tool roll is that? Is that a multi nut driver deal?
@curioushvacguy6876
@curioushvacguy6876 3 жыл бұрын
yeah a multi nut driver set I found on Amazon of course- I started using it back in my home appliance repair days-- its a great little kit
@adamspears3819
@adamspears3819 3 жыл бұрын
As soon as some "Super Tech" out there saw you use wire nuts, they instantly became triggered🤣
@steveblake8766
@steveblake8766 5 жыл бұрын
#18 Thumbs UP
@derekobidowski3301
@derekobidowski3301 4 жыл бұрын
that will do it bad fan motors can cause the high pressure switch to trip. it could be a bad run cap the motor did not start or the windings bad internally in the motor the defrost time clock Jim pettanato not a fan of them on his channel he changes these grasslin time clocks to a older style Paragon clock if its 208-230 if a cooler it be a paragon 8140-20 for a freezer be a 8145-20 with defrost termination. as long as the clock is oiled it should last as they have replacement timer motors for them. i thought Russell coils were once named Witt.
@DW-bo3qw
@DW-bo3qw 5 жыл бұрын
It didn’t look like there was anything going to 4 on that clock boy
@DW-bo3qw
@DW-bo3qw 5 жыл бұрын
Haha didn’t mean to type boy lol just looked like 1 and n from what I could see
@DW-bo3qw
@DW-bo3qw 5 жыл бұрын
Yea that clock came from the factory but was never field wired
@edwardapostolos5954
@edwardapostolos5954 4 жыл бұрын
That defrost clock is not hooked up
@mackenziegray2090
@mackenziegray2090 3 жыл бұрын
Its a cooler not a freezer. Operates above 32°F.
@gregmercil3968
@gregmercil3968 4 жыл бұрын
What brand are those wire strippers you're using?
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
I believe they are Klein- I will double check though
@scottkrempel3005
@scottkrempel3005 4 жыл бұрын
so much for the p.m. 2 weeks ago.
@IFIXCASTLES
@IFIXCASTLES 5 жыл бұрын
Stop poking holes in the roof!
Carrier package unit not cooling: Part 2
20:43
Curious HVAC Guy
Рет қаралды 12 М.
Defrost issues
19:19
Curious HVAC Guy
Рет қаралды 9 М.
The Joker kisses Harley Quinn underwater!#Harley Quinn #joker
00:49
Harley Quinn with the Joker
Рет қаралды 38 МЛН
Incredible Dog Rescues Kittens from Bus - Inspiring Story #shorts
00:18
Fabiosa Best Lifehacks
Рет қаралды 33 МЛН
Violet Beauregarde Doll🫐
00:58
PIRANKA
Рет қаралды 47 МЛН
Walk in cooler not cooling
13:21
Curious HVAC Guy
Рет қаралды 18 М.
WALK IN FREEZER KEEPS TURNING OFF
11:32
HVACR VIDEOS
Рет қаралды 50 М.
Walk in cooler not cooling
13:23
Curious HVAC Guy
Рет қаралды 23 М.
Walk in cooler to warm
25:07
Curious HVAC Guy
Рет қаралды 21 М.
WALK IN FREEZER WITH TOO MUCH FROST
14:52
HVACR VIDEOS
Рет қаралды 463 М.
This is How You Clean a Walk-in Cooler Evaporator.
14:54
OcRefrigeration , Hvac & Electrical Video's.
Рет қаралды 67 М.
HVAC Refrigeration:  Reach In Cooler Compressor runs but doesn’t pump.
11:48
Rookie Refrigeration
Рет қаралды 17 М.
Why is the walk-in cooler icing up
44:47
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 21 М.
The Joker kisses Harley Quinn underwater!#Harley Quinn #joker
00:49
Harley Quinn with the Joker
Рет қаралды 38 МЛН