I find myself waiting for your videos more then the other content creators. They are awesome too but you make it short, to the point with great explanation. Keep it up.
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Thanks, much appreciated.
@yantur51 Жыл бұрын
We all need to learn from this guy
@crystalcleanappliance5903 Жыл бұрын
Your vids are golden my guy
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Thanks
@electroimpex8897 Жыл бұрын
Very interesting and quality Video, greets from Germany 👍
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Glad you enjoyed it!
@EverythingHVACR Жыл бұрын
I hate rub outs. Most are preventable. Nicely done
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Yes, this easily avoidable
@fernandojimenez1949 Жыл бұрын
For superheat on walk ins, do you find your suction line temp before the compressor or somewhere inside the box? 8:29
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Yes, just before the trap, downstream of the coil
@harrydickson4575 Жыл бұрын
Awesome 👍👍👍
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
👍
@shine-cg9uf Жыл бұрын
👍🇺🇸💪❄️ nice vid thanks for sharing
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
👍👍
@Jay-d2m5m Жыл бұрын
New to your channel and the trade. When determining your saturated temps and pressures, why in some videos do you start with current box temp and other desired. Any particular reason?
@DannybFlat01 Жыл бұрын
I have two water cooled compressors, I live in Ohio so could I shut the water off in the winter to save some money? Any help is greatly appreciated sir. Thanks
@MaksimMaksimenko-vb5eh11 ай бұрын
why TD - 10F? Where you get this information?
@AErefrigeration Жыл бұрын
What are your thoughts on changing over to r407a?
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
R448A is what we are currently using for conversions
@dennisvo5416 Жыл бұрын
What brand leak detector is that you use.?
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Dtek 3
@mikeg3529 Жыл бұрын
Interesting...is the condenser cooled by plumbing water and just dumping it down the drain once its removed the heat, or does it have its own loop with an outdoor unit to recycle the water?
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
Dumping down the drain, wastes a lot of water. We need to keep the incoming water temperature a consistent temp so I don’t think recirculating of the water is an option but I could be wrong
@tonyrichards2017 Жыл бұрын
I always use silicon on cap tubs and spiders found on large rtu saves rub outs
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
⬆️ 👍
@jeremyhall7951 Жыл бұрын
Thats something Ive never worked on.
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
They are pretty common in confined areas where high ambient temperature is going to be an issue
@billyhorton5779 Жыл бұрын
Do you prefer to coil capillary tubes and then individually separate the tubes or zip tie them together as one? Wow, your videos make going to HVAC school almost unnecessary, in my opinion.
@SovereignTroll Жыл бұрын
I was taught to coil the mileage around a glass, etc., separate and Caulk permanently together so no vibration cracks and rub outs. Wiring too.
@REFRIGERATIONKITCHENEQTECH Жыл бұрын
In this case the capillary tube was too short to coil up. What is written above with cooling and caulking is a great suggestion