Glad you mentioned about the pumps being as low as possible I've got a friend who's got his pumps higher than the tank and they're sideways on the side of the van and he said once there prime they're ok he said they're really good pumps he said they've been going about 9 to 10 years and I was about to do the same but after seeing this I've changed my mind great video thanks for the info
@johnbowles47543 жыл бұрын
I've just finished building two trolley based wfp's for my son, thank you for the info about the different types of pumps it has helped me a lot. 😎 👍
@richmoore1364 жыл бұрын
Thanks for the video well explained massive help all the answers for me top man
@davespotlesscleaning38972 жыл бұрын
Fantastic video thank you
@adornwindowcleaning7739Ай бұрын
Pump is pulsing for a few secs every 4 secs ? shurflo pump & digital controller read it's normal - not sure any advice - thanks Deane
@colonynaut16273 жыл бұрын
Interesting info, thank you. I assume if I hooked a standard Sureflo to one of those backpack flow controllers - I could bypass the pressure switch for more reliable results? I'll test this but this is a new area for me so all tips are helpful, it was interesting to learn the pump may have a mind of its own independently of the flow controller. I think too the flow controller and the pump must be rated at the same amp rating - somebody say if that's not right.
@craigjones68122 жыл бұрын
Thank you very much sir.....
@bobbymac1319 Жыл бұрын
I’m getting P5 and I’ve disconnected my pressure switch???
@andrewarmstrong10172 жыл бұрын
My sureflow pump is connected to a digital controller....the lump is A1...but the pressure switch is clicking...which made me think ,it needs replacing...but as you say on your video...I can bi pass it....as the controller will just dead end?.....
@thoroughcleanservices826310 ай бұрын
I’ve just fitted new digital controllers but p5 code is displaying and no noise or anything coming from pump any idea
@stephw12782 жыл бұрын
great video
@bobbymac13193 жыл бұрын
how do you wire the pump straight to the controller?
@rickyfinlay372610 ай бұрын
My wfs at the moment is not working correctly, when I turn it on it runs with no water coming out so I take of the hose running into the ds bottle and I suck the water through and it works perfectly,until I turn it of then it doesn't suck water through, then I have to start sucking water through again.does anyone know what the problem is.
@lusean1933 жыл бұрын
Can anyone post a link for the controller and pump thanks
@DavidSmith-gj2dm4 жыл бұрын
Very good , thanks for that , I have a pump ( on the right in your video ) that I’ve been using since 2006 , still going . Didn’t know about bypassing the mechanical micro switch . Just having issue with auto controller , despite full charge it’s flashing “ batt “ all connectors clean , pump works for 2/3 mins then winds down to nothing , there is a bit of corrosion inside the controller, suspect shorting on circuit board ,, is it worth resoldering ? Thanks again , excellent video