No video

What is a LIGHTER Pot

  Рет қаралды 2,828

Hiline Academy

Hiline Academy

Күн бұрын

Пікірлер: 13
@daveg.4862
@daveg.4862 Жыл бұрын
EE here Cody. First thank you for making these Great Videos. They fill in sooo many blanks for us industrial sparkys. Open Delta services can cause problems on SCR/IGBT controls because they deform the sine wave (making the peak higher) an tripping the drives on high bus faults. RMS voltage stays ok, so you can only see it on a Scope. You are a great Teacher! keep up the good work. Closing the Delta fix's it. (but thats more work for you guys)
@hilineacademy8482
@hilineacademy8482 Жыл бұрын
Lol. Yes sir. Will do. I appreciate it. Stay safe 👍
@jeffreykornspan9053
@jeffreykornspan9053 Жыл бұрын
Nice demonstration
@hilineacademy8482
@hilineacademy8482 Жыл бұрын
👍
@zackberghoefer5174
@zackberghoefer5174 4 ай бұрын
Question, on the board in the shop you had A feeding the power pot and B feeding the lighting pot? Wouldn’t that give you counterclockwise rotation?
@bordersoldier
@bordersoldier 2 жыл бұрын
Another great lesson !!!
@hilineacademy8482
@hilineacademy8482 2 жыл бұрын
Thanks babe. 👍
@StoneStraiff
@StoneStraiff Жыл бұрын
Thankyou so much for this
@hilineacademy8482
@hilineacademy8482 Жыл бұрын
Any time 👍
@dandisen2643
@dandisen2643 9 ай бұрын
Is it true to say that the Lighter Pot/Power Pot is the same as Open Delta bank? Comparing this video vs the Open Delta Bank video that you made, it appears that both are same connections. Am I understanding this correctly?
@hilineacademy8482
@hilineacademy8482 8 ай бұрын
Yes sir. When building a transformer bank that has a 4 wire delta connection on the secondary side (meaning three phases and a neutral) you will have both phase to neutral load, and phase to phase load. The phase to neutral load is referred to as “lighting load”, and the phase to phase load is referred to as “Power load”. The transformer that is supplying the neutral is called to lighter because it is the only transformer supplying the phase to neutral load. That’s why we call it the “Lighter. “ It does not mean that it is lighter in weight. The other transformer / transformers are only supplying the power load, or the phase to phase load. Please let me know if this answered your question. Stay safe 👍
@tedlahm5740
@tedlahm5740 Жыл бұрын
The lighter designated transformer would typically be LARGER in size (more current) than power pot? Open Delta two transformer system? Excellent explanation.
@hilineacademy8482
@hilineacademy8482 Жыл бұрын
Yes sir. The lighter pot is carrying all of the single phase load and two phases of the three phase load therefor it needs to be a larger K a pot. 👍
English or Spanish 🤣
00:16
GL Show
Рет қаралды 6 МЛН
What is FERRORESONANCE?
13:41
Hiline Academy
Рет қаралды 12 М.
HOW TO: Vector Transformer Banks
25:23
Hiline Academy
Рет қаралды 13 М.
INSTALL: Single Phase Transformer #journeyman #linelife #lineman
9:28
What’s An Open Corner? - WHY is it Important? 🤔
29:28
Hiline Academy
Рет қаралды 8 М.
Alley Cat, Bad Dog?
10:51
Hiline Academy
Рет қаралды 4,2 М.
TRANSFORMER POLARITY: Everything you need to know
9:00
Hiline Academy
Рет қаралды 16 М.
Wye - Wye You Always Tie
17:23
Hiline Academy
Рет қаралды 15 М.
The "Broken Delta Winding" and what we really measure!
7:37
Electrical Engineering Academy
Рет қаралды 29 М.
Going Somewhere
10:40
Mountain States Line Constructors
Рет қаралды 9 М.