Thank you very much for these practical aspects sir. It's such a masterpiece.
@amalababu91 Жыл бұрын
Thanks 🙏
@karthickjoel9705 Жыл бұрын
Is there any pipe thickness condition for PWHT
@OilandGas-inspection-soumen Жыл бұрын
Please refer ASME Section IX - Beforee it was 20 mm and above. But latest standard is changed- you need refer the table for it. For ASME B31.4 and B31.8, means for pipeline , PWHT is required if pipe thickness is more than 1-1/4 inch or 32 mm
@naveenvikrampmp7808 Жыл бұрын
Regularly Watching your videos in this channel. Hatsoff to you! Doing PWHT before RT is OK? because if there is any repair in welded joints we have to attend as per Qc instructions I didn't get any data reg this sequence-RT before or after PWHT. Please advice sir!
@OilandGas-inspection-soumen Жыл бұрын
Thanks Mr Naveen. I am grateful that you are achieving something from my knowledge sharing videos. Actually PWHT has to be done after welding. Contractor is doing RT before PWHT- is only to ensure- that not mandatory and only to assure that the joint has no repair. If you have good performance of welders, you can always do RT after PWHT- nobody can stop you.
@federicolaufgang114 Жыл бұрын
Hi, i have an PWHT and NDT company in South America, Argentina. Can un help me to provide our services in your country? We can do business together