When a Variable Blower Runs Too Slow

  Рет қаралды 149,656

HVAC School

HVAC School

Күн бұрын

Пікірлер: 68
@acrepairnearme
@acrepairnearme 6 жыл бұрын
Greatest video! Thank you so much. Very informative
@LC-go1uh
@LC-go1uh 2 жыл бұрын
You should check "word of advice TV"! The guy does it for a living and he is very good at explaining things. He has the best videos I've ever seen on HVAC systems. You can tell he knows what he's talking about and he explains it in a way that is very simple and easy to understand. This video here didn't compare to his. He has a nice long video on the blower motor and how to check everything on it. If you can't find your HVAC problem after watching his videos, you just don't have the talent to fix these sort of things. This year was one of the most boring videos I've ever watched on KZbin and honestly it didn't explain much at all. What if the motor is bad or seizing up? He didn't explain any of that. This guy is not very good at elaborating. Elaboration is a talent you have to have, if you want to have good videos. Hopefully he will get a little better one day, but I highly doubt it because he looks pretty old already.
@anthonyS-DSC
@anthonyS-DSC 6 жыл бұрын
Awesome video. Thanks for the details on y1 - y/y2 configuration -
@funkbro2
@funkbro2 4 жыл бұрын
I have an older furnace so it doesn’t have many functions, it does not use a Y wire for cooling In cooling this year I can see voltage on the high speed wire going to motor, but it doesn’t seem to go to higher speed than low I should say though, low speed on this is med/hi and it seems to only run at med/hi
@rajoursmaraj6774
@rajoursmaraj6774 3 жыл бұрын
Hello i have a question regarding my hvac system. The blower is running slow constantly. I checked in my hvac system i dont have y2. I have C- black and red wire, Y-white and yellow wire, Gc-green wire, Gh- there is no wire that attached, R- red wire, W- white wire. What is the wire do i need to connect to in order for me to get the full speed blower? Please help me i do watch your video a lot to try and fix my blower is running slow.
@Daluke61
@Daluke61 4 жыл бұрын
"Okay Guys"; no wait, what? So my package RTU's blower motor's (occasionally) speeding up/slowing down/speeding up/slowing down; all during a single cooling cycle. Also, it's just the blower motor that's acting up, not the condenser fan. The compressor will stay on. Replaced capacitors which seemed to help (even thought it's an ECM blower motor) but it's still acting up every now and then... kinda weird. Clues? Great channel, BTW... thanks!
@HVACS
@HVACS 4 жыл бұрын
Thankyou
@PaintSandwhich
@PaintSandwhich 4 жыл бұрын
I’m pretty sure nobody was on my roof playing with my wire config...what else could we check?..when I press the plunger switch in it seems to be kicking on the blower.
@nsboost
@nsboost 6 жыл бұрын
Crazy looking at this stuff on your heat pump set ups. I don't see anything like it here in the northern states where NG/LP is readily available.
@Brian-Outdoors
@Brian-Outdoors 2 жыл бұрын
On this same board if you have jumper j1 installed does that disable the DH connection for dehumificaton? It looks to apply 24 VAC to the DH connection disabling dehumidification or the reduced fan speed for dehumidification.
@EbanQHanna
@EbanQHanna Жыл бұрын
Thanks for the video. Should the wiring at the thermostat also match the wiring at the control board? For example Y-Y, C-C,G-G, etc
@junior-hk2jt
@junior-hk2jt Жыл бұрын
The symbols should match the colors usually do also except you might have a variation of blue or yellow for y ...so yeah pretty much...
@V2RocketScientist
@V2RocketScientist 2 жыл бұрын
So the issue I discovered with mine is the blower can run at all the speeds my thermostat calls for when only the fan is running, but shortly after the AC kicks on the blower will gradually slow down to a crawl which sounds like the de humidification mode and yeah, I don't want that because that's a huge waste of energy and it might be freezing up the coil too. So if I follow your video correctly, when I go look at the board I need to make sure each terminal is getting the right voltage. Maybe this is a sign that my thermostat has failed to provide the right voltage recently and the air handler thinks I want to dehumidify instead of cooling? It definitely didn't do this before but I don't know when it started; I just noticed it today.
@TheSamhi
@TheSamhi Жыл бұрын
I have an older carrier that is running on slow fan speed, It is Carrier circuit board HH84AA020, Do you have an answer for me. Thank you.
@nedkent5239
@nedkent5239 3 жыл бұрын
I have a Carrier Performance 96 59TP6 and no techs in my area know anything about them. For 3 years in the winter the low speed fan is too low so have freezing parts in the house. I have been through the service manual 40 times trying to figure it out. Do you know what dip switches?
@killinemsoftly5046
@killinemsoftly5046 4 жыл бұрын
i have a heat pump (single-stage) and it feels like the motor is not running at full speed and on my thermostat my yellow wire is connected to Y not Y2. you think that can be the problem?
@OscarHernandez-fw6zg
@OscarHernandez-fw6zg 4 жыл бұрын
Y and y2 are the same. Only y1 is different
@ernestogalindo3149
@ernestogalindo3149 2 жыл бұрын
By not removing jumper J1, should the blower always run at full speed?
@tdtk1998
@tdtk1998 5 жыл бұрын
Hi, I have an AC unit that looks exact the same in your video. I have a problem with blower motor that kept running all the times ( unless I turn the breakers in garage off). It ran even when I took the the thermostat out. I have replaced the board thought it was bad. I also changed the thermostat to Nest Thermostat but it didn't fix it. I thought it was the relays (with small boards attached to them), but still didn't fix it. Addition, I have variable speeds with 240v on one terminal and bunch of wires on the other terminal, both plugged on the motor. Please tell me why my motor keep running? what is the correct setting for those jumper wires on the control board. Thanks
@obe1canobe146
@obe1canobe146 5 жыл бұрын
Daniel Cao probably a rollout or sensor switch
@edwardgarza5104
@edwardgarza5104 2 жыл бұрын
The module on the ecm motor sounds to be faulty. There's usually 2 plugs on those motors one set is low voltage and the other is high voltage. Find the low voltage plug and remove it and see if it still runs if it still runs module is bad , replace module if it turns off control board or thermostat control wires are shorting together. Some checks if u haven't fix it yet
@macknumber9
@macknumber9 Жыл бұрын
My blower runs slow and doesn't have any airflow at the vents. However if I turn off the breaker and restart it then I get full speed from the blower and then it shuts back down to slow speed and doesn't blow any air out the vents....
@erinbaney3575
@erinbaney3575 2 жыл бұрын
I’m just starting this video and you should always tell people to turn the breaker off. I don’t know much about heat pumps thus why I’m looking this up but you have to make sure people are safe.
@erinbaney3575
@erinbaney3575 2 жыл бұрын
If you need to test wires, you keep it on but you need to tell people to be careful.
@arod4056
@arod4056 Жыл бұрын
My hvac has variable speed blower motor. It does get to full speed, it just takes a long time. I do like the idea of it adjusting the speed of the fan depending on the comfort, but is there a way to speed the process to get to full speed?
@anthonybernier9952
@anthonybernier9952 7 ай бұрын
Yes depending on the unit the Daikin fit has options for this. What area do you live in?
@anthonybernier9952
@anthonybernier9952 7 ай бұрын
And the Amana S unit which is the same thing just Different label and 2 years less warranty
@Reckless_In_Texas
@Reckless_In_Texas Жыл бұрын
What about if its running too high?
@bradmarshall7075
@bradmarshall7075 Жыл бұрын
Has anyone seen a ecm motor run to fast? I went to a 2017 Rheem RHIT3617STANJA and the homeowner said the return and supply are very loud and it just started last week. I tried changing the speeds with no luck. Is it possible the programming or something has caused the motor to go full speed on all speed taps?
@aaronshensky9385
@aaronshensky9385 5 жыл бұрын
What if the motor trys to ramp.up to high speed but fails and stays in low or just under low speed? I have a 10tr old trane XR series furnace with the ecm variable speed blower. Thank you. I.wish you can reply.
@chrishale
@chrishale 4 жыл бұрын
This is the issue I'm having did you find a solution?
@aaronshensky9385
@aaronshensky9385 4 жыл бұрын
@@chrishale I replaced the motor and ecm together. I purchased online for 300$ for the motor with the ecm. Came with a 1yr warranty. I honestly think my motor was the fault but both were 10yrs old so 300$ and I installed in 2hrs.
@chrishale
@chrishale 4 жыл бұрын
@@aaronshensky9385 yeah I have a new one coming tomorrow to install. The OEM motor was 2 weeks out so hopefully this evergreen will work.
@macknumber9
@macknumber9 Жыл бұрын
@@aaronshensky9385 I have this problem except when I turn breaker off and restart it the blower starts up in full speed and then goes back to slow speed after about 5 minutes...keeps trying to go to full speed it makes these noises like its trying to but it won't do it.
@diegoramirez5545
@diegoramirez5545 4 жыл бұрын
I have the same problem as you state here and notice there’s no voltage between common and Y2. Does that mean I have to replace the blower?
@HVACS
@HVACS 4 жыл бұрын
Thankyou for your question I will answer it soon in my Q/A video
@mgomez5606
@mgomez5606 3 жыл бұрын
They replaced the blower motor on my Amana and it runs slower than the motor they replaced. You could barely hear it. The old one you could. Since its running slow the lines froze up on unit outside. I told the tech about the speed and he said speed would increase. Don't think he knows what he is talking about. So can they speed it up? Two connectors hook up to motor. Could he have connected them where they are not suppose to go and cause this slow speed.
@tomtom1541
@tomtom1541 3 жыл бұрын
Probably has the wrong motor which is meant for a different size unit. Have you confirmed the part number to see if it's correct?
@mgomez5606
@mgomez5606 3 жыл бұрын
@@tomtom1541 The motor was wired wrong from the factory. Took it off and switched wires and was blowing like it's suppose to.
@elliottvalentine104
@elliottvalentine104 3 ай бұрын
@@mgomez5606how was it determined that it was wired wrong? I've had an Amana for 3 years with variable speed handler and it doesn't blow nearly as hard as the old single speed unit it replaced. It almost feels like it runs 60%, was this your same experience?
@mgomez5606
@mgomez5606 3 ай бұрын
@elliottvalentine104 They had to take the blower motor out and changed the wire connections. They had to call the company that makes the motor and they told them the correct sequence of connections. They had replaced two before they called them.
@kevinknecht3275
@kevinknecht3275 3 жыл бұрын
What if half the time it blows on slow speed but the other half on high speed? When it blows slow, I can flip the blower switch off and right back on and it will start back up in high speed.
@macknumber9
@macknumber9 Жыл бұрын
I am dying to know the answer to this as well...this is exactly my problem. Blower is weak as can be no airflow but when I turn it off and back on it comes back on fast for about 15 minutes
@TheDbldwn02
@TheDbldwn02 4 жыл бұрын
Just out curiosity, why would the dehu need to be called to speed UP the fan? Seems like poor engineering but then again I'm not an engineer yet so what do I know? :-)
@Synaux
@Synaux 3 жыл бұрын
How does one perform a blower call (sorry if that is an absurd question)
@riverraisin1
@riverraisin1 Жыл бұрын
Go to the nearest red light district and wave cash out the window.
@twosawyers
@twosawyers 4 жыл бұрын
Will it dehumidify better at a slower speed?
@TheDbldwn02
@TheDbldwn02 4 жыл бұрын
Yes.
@Sashazur
@Sashazur 2 жыл бұрын
What could be causing my blower speed to fluctuate a lot but mostly run at very low speed during cooling season? This is a problem I’ve been having during a recent spell of hot weather. Usually turning the system from cool to off for several hours fixes the problem and then it’ll work fine again for a day or two. If I leave the system off but the fan on, it seems to blow at the expected medium speed.
@macknumber9
@macknumber9 Жыл бұрын
What did your problem end up being? I have pretty much the same issue
@Brad.W
@Brad.W Жыл бұрын
​@@macknumber9if I had to guess he has a bad blower capacitor. It's all you had the blower motor on a Trane variable speed ECM blower motor it wasn't running anywhere near as fast as it should technicians come out and did blood tests and determined get my blower run capacitor was super weak.
@凌晨-l8g
@凌晨-l8g 4 жыл бұрын
sir: my heat pump package ECM blower will only work when its fan is set to ON. In auto, it stops
@Jbasto97
@Jbasto97 3 ай бұрын
So single stage compressor should always be on on Y/Y2 not on Y1😮
@fiery_redbeard9082
@fiery_redbeard9082 3 ай бұрын
Most of the time yes. But some brands are different. Slow down and read the manual. You will learn tons just doing that
@michaelkennedy2528
@michaelkennedy2528 3 жыл бұрын
Crazy thing happens to mine, it is a 2 stage 3 ton ICP unit with variable speed air handler. It was set at "normal", we put it to low because it would run nice and steady except right before it shuts off, like the last 3 or so minutes would haul ass, rattle the vents it blows so hard. No one can seem to figure it out. Nice and quite but then the tornado lol. Any ideas?
@nathanhopkins6939
@nathanhopkins6939 3 жыл бұрын
Does the hp size setting have to match the unit installed? A service provider set mine to 3.5 ton to get more air flow but I only have a 2.5 ton heat pump
@drrivera6626
@drrivera6626 6 жыл бұрын
You just said it
@Jackman66666666
@Jackman66666666 3 жыл бұрын
Camera was making me dizzy
@LC-go1uh
@LC-go1uh 2 жыл бұрын
That didn't help anything!
@Z-Ack
@Z-Ack 2 жыл бұрын
Cant heat ya when you go all low talk mode at the end of your points your making or when you say something kind of away from the specific topic you were speaking about,.
@Z-Ack
@Z-Ack 2 жыл бұрын
Hear.. cant hear,. Not heat..
@minnesotasalamander5913
@minnesotasalamander5913 Жыл бұрын
You talk to fast dude, cutting down on the coffee would probably get you more subscribers.
@redbaren67
@redbaren67 9 ай бұрын
Honestly he was very clear and concise and physically showed each thing he was talking about and was to the point that is exactly how all explanation videos should go unless he was breaking down some crazy in-depth thing like calculating with math which this was not.
@ryk1265
@ryk1265 6 ай бұрын
On the lower left corner of your screen there is a wheel looking thing commonly called as settings. Click it and select playback speed under 100, now go find your helmet!
@ryk1265
@ryk1265 6 ай бұрын
*right lower corner
Diagnosing a Bad Blower Motor (8 Easy Things To Check)
6:51
Fox Family Heating and Air Conditioning
Рет қаралды 189 М.
Genteq Variable Speed Constant Airflow ECM Troubleshooting 101
11:23
Yay, My Dad Is a Vending Machine! 🛍️😆 #funny #prank #comedy
00:17
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 4 МЛН
World’s strongest WOMAN vs regular GIRLS
00:56
A4
Рет қаралды 5 МЛН
Adjusting HVAC Blower Speed CFM on Furnace & AC Units!
10:06
AC Service Tech LLC
Рет қаралды 212 М.
Changing the Blower Speed on a Furnace
6:08
Cool Stuff Guys Like
Рет қаралды 197 М.
Variable Speed Blower running at low speed in cooling
8:18
Anti DIY HVAC
Рет қаралды 110 М.
Air Handler Blower FAN WON'T TURN OFF! 5 Reasons Why it Keeps Running!
11:09
AC Service Tech LLC
Рет қаралды 657 М.
Trane Variable Speed blower Easy troubleshooting Tech Tip
4:14
Anti DIY HVAC
Рет қаралды 88 М.
Furnace or AC Blower Motor Not Starting | Loud Buzz or Humming Noise
9:18
Everyday Home Repairs
Рет қаралды 371 М.
Control Your Air Handler Fan Speed Like a Pro! @YorkHomeComfort
11:29
Air Handler Wiring for Beginners (Fan Relays & PSC motors)
12:09
Jersey Mike HVAC
Рет қаралды 121 М.