WHITE RODGERS 1311-102 HOW TO REMOVE AND REPLACE

  Рет қаралды 12,553

Alex The Handyman

Alex The Handyman

Күн бұрын

In this video I will show you how to remove and replaced a White Rodgers Zone Valve

Пікірлер: 22
@bennyrubio7243
@bennyrubio7243 2 жыл бұрын
Alex thank you so much for this video im glad I found it and followed all the steps. God bless brother
@alexthehandyman3494
@alexthehandyman3494 2 жыл бұрын
Hello Benny, IM so glad you liked it. Wait until you see the other white rodgers video. You ll love it. It is on how to troubleshoot, wiring, sequence of operation et c.
@raulescobar3881
@raulescobar3881 3 жыл бұрын
Thank you very much for making this video!!! You’re a lifesaver and the video was very well done!
@alexthehandyman3494
@alexthehandyman3494 3 жыл бұрын
Hola Raul Thank you Im glad it was useful to you., Thanks for subscribing. See you next video
@miguelmateos9828
@miguelmateos9828 2 жыл бұрын
Alex do you know how I can replaced the zone valve white - rodgers model f109181 I appreciate your Advice I take out the head but the bottom its so hard to take out
@tonyjuneau
@tonyjuneau 11 ай бұрын
Thanks dude!
@jziggy4631
@jziggy4631 3 жыл бұрын
Very helpful. Thank you.
@alexthehandyman3494
@alexthehandyman3494 3 жыл бұрын
thank you Ziggy. I have part B of this video Is about wiring and troubleshooting. Go to Alex the handyman Thanks for subscribing
@esaamawshana1018
@esaamawshana1018 Жыл бұрын
Good job thank you for showing that
@midwestteediamondhands5460
@midwestteediamondhands5460 Жыл бұрын
Thank you
@l.a.m7645
@l.a.m7645 2 жыл бұрын
So when installing new valve does the dial have to be in open or closed position?
@R0am3r
@R0am3r 2 жыл бұрын
It doesn't matter if the valve is open or closed. Just make sure the control aligns properly so it fits properly. The control knows position of the valve from the alignment.
@geraldross9430
@geraldross9430 9 ай бұрын
You mentioned the thermostat wiring and did not illustrate or show the back of the stat?
@alexthehandyman3494
@alexthehandyman3494 9 ай бұрын
kzbin.info/www/bejne/iHeUo6KMh5V_a80si=6E3oOguqKH9pKQk3. Hello Gerald. The video you just watched is about how to remove and replace the power head. Look at this video it has greater detail on wiring and thermostats
@timdubois9298
@timdubois9298 3 жыл бұрын
great job
@paologanci4462
@paologanci4462 2 жыл бұрын
Do I have to drain the pipes before I remove the valve
@alexthehandyman3494
@alexthehandyman3494 2 жыл бұрын
Hello Paolo, Turn the boiler off first. Hopefully you have shut off valves before and after the valve. If not, shut off every valve you see in your system. All of them! We want to avoid draining your system. Be ready to collect water off the valve when you remove it. If you don't have shut off valve then just remove (relieve) some pressure by draining just a little bit off water from the boiler drain. After you replace the valve make sure you add water to the system until it reaches 12-15 lbs of pressure (your feed valve should do it atuomaticlly, Also you might have to bleed air out of your system. See my other videos. Good luck . let me know how it goes. Thanks
@paologanci4462
@paologanci4462 2 жыл бұрын
@@alexthehandyman3494 thank you Alex you saved me lots of money thanks
@alexthehandyman3494
@alexthehandyman3494 2 жыл бұрын
@@paologanci4462 Glad to hear that., Thanks
@jett7777771
@jett7777771 3 жыл бұрын
Good till it came to wiring you should have shown what wire goes to what number on zone valve “
@alexthehandyman3494
@alexthehandyman3494 3 жыл бұрын
Hello Cash Money.. this was about how to remove and replace. I have another very detailed video on wiring and troubleshooting. go to alex the handyman
@epluribusunum5405
@epluribusunum5405 8 ай бұрын
Either that or you can look at the instructions for wiring 1311 and for that model 5 is power at all times. And 4 opens when it makes call for heat. And six closes when it opens energizing 6. Therefore your 3 wire. Using a certain type of thermostat for 3 wire.spdt thermostat. So 1 would be always 24 v neutral and 2 24 v hot from the transformer. Refer to wiring instructions.
WHITE RODGERS 1311  SERVICING, SEQUENCE OF OPERATION, WIRING,TROUBLESHOOTING
26:45
How to Change a Zone Valve - Hot Water Boiler Heating System
9:20
Это было очень близко...
00:10
Аришнев
Рет қаралды 4,3 МЛН
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 14 МЛН
Сюрприз для Златы на день рождения
00:10
Victoria Portfolio
Рет қаралды 2,2 МЛН
WHITE RODGERS 1311-102 STEP BY STEP REPLACEMENT.
24:33
Alex The Handyman
Рет қаралды 1,1 М.
Fixing My Baseboard Heater Zone Valve
9:15
Alaska Workshop
Рет қаралды 27 М.
How To Remove Air From Your Heating System
5:24
TheDIYGuyDOTnet
Рет қаралды 1,7 МЛН
Connecting Nest Thermostat To A Boiler
11:43
One Hour Smart Home
Рет қаралды 114 М.
How to Change & Wire a Honeywell Motorised Zone Valve
7:15
Heritage Electrical
Рет қаралды 12 М.
Wiring an L8182D Aquastat with 2 honeywell zone valves
17:47
Tony Saccavino-HVAC Instructor
Рет қаралды 12 М.
How the Honeywell zone valve works.  Part 1
7:07
grayfurnaceman
Рет қаралды 190 М.
Motorised Valve Fault Finding
9:08
Skill Builder
Рет қаралды 27 М.
Inside a Central Heating Zone Valve Actuator
12:53
John Ward (jwflame)
Рет қаралды 168 М.
Hydrotherm Gas Boiler No Heat Bad Zone Switching Relay Replaced Taco SR501 Installed
15:12
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 14 М.
Это было очень близко...
00:10
Аришнев
Рет қаралды 4,3 МЛН