@pramitapsatapathy5037
@pramitapsatapathy5037 4 ай бұрын
Clarity in concept. Awesome sir.
@Er.ManishYadav-x5u
@Er.ManishYadav-x5u Ай бұрын
🥰🥰🥰🥰🥰
@surendrakverma555
@surendrakverma555 4 ай бұрын
Thanks
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
Nice video
@mularamjat2090
@mularamjat2090 4 ай бұрын
Nice 👍
@kks_07
@kks_07 4 ай бұрын
Super 👍
@shrirambajiya6108
@shrirambajiya6108 4 ай бұрын
Nice video ❤❤❤❤❤
@dkyoutube-15
@dkyoutube-15 4 ай бұрын
Good and informative, I request you to please share control drawings of starters also.
@Sanjeeb96
@Sanjeeb96 4 ай бұрын
Nyc
@gopiswain2572
@gopiswain2572 2 ай бұрын
Sir please make a video about Ac synchronous motor
@NikRajput
@NikRajput 4 ай бұрын
Sir, Next video on Interview questions of NIFPS system..❤
@fayazkhan798
@fayazkhan798 28 күн бұрын
sir, please make study vidio on VFD
@zoominlife9919
@zoominlife9919 4 ай бұрын
Sir please make a video for cause of motor troubleshooting
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
Sir please make a video on HG fuse
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
What is the difference between step down and step up transformer make a video on that sir
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
What are the different types of potential transformer like IVT and CVT
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
What are the different types of vacuum circuit breaker
@dibyaranjanbehera8969
@dibyaranjanbehera8969 4 ай бұрын
Measuring pt and protection pt difference
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
What is the breaking capacity of vacuum circuit breaker
@dibyaranjanbehera8969
@dibyaranjanbehera8969 4 ай бұрын
Before change over of incomer what we have to see
@NikRajput
@NikRajput 4 ай бұрын
Angel of Buchholz Relay ??
@abhisekbhowmick9862
@abhisekbhowmick9862 4 ай бұрын
What is ER TRIGGER in SEL relay?
@sok327
@sok327 4 ай бұрын
Sir motor rpm Kam kese hota he or Jada kese hota he pls ek video banao
@farazniaz2356
@farazniaz2356 4 ай бұрын
RPM tb barhta hai jab motor ki stator winding mai ziyada current draw hota hai jis se winding ki magnetic field teezi se rotor ki winding ko cut krti hai tou rotor teez ghomta hai or current bhi ziyada draw hota.
@vikasparmar18
@vikasparmar18 4 ай бұрын
20hp ki motor he use 7000 rpm ki motor ko design kese karte he. Normal 20hp ki motor ke bhi vfd se 7000 rom pe chala sakte he kya?
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
Types of test conducted on transformer
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
Is lt motors also known as delta motors sir
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
Is vacuum circuit breaker used as outdoor
@kahaniya959
@kahaniya959 4 ай бұрын
Both
@prashantdewangan8411
@prashantdewangan8411 4 ай бұрын
Sir ek 200 kw ka motor drive me chalane par ground faults me trip ho jata hai par usi motor ko stater me chalate hai to normal chal rha h ..kya karan ho sakta ki whi motor drive me nhi chal pa rha h ... explanation kre ..
@darshansinghrawat9732
@darshansinghrawat9732 4 ай бұрын
Drive over sense kr ri h
@shyamsunderdeo7208
@shyamsunderdeo7208 4 ай бұрын
Sir किस टाइप की मोटर को स्टार डेल्टा स्टार्टर से चला सकते है और किस टाइप को नही
@shivampandey________3478
@shivampandey________3478 3 ай бұрын
Mere yha bhi all motors delta connect Hai Mere abhi industry me star me koi motor connect nhi ki hai
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
Is vacuum circuit breaker an medium voltage breaker
@kahaniya959
@kahaniya959 4 ай бұрын
Nothing is medium voltage Low voltage, High voltage and extra high voltage (LT, HT and EHT) VCB is used in HT and EHT line both
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
What is the difference between buscoupler and busbar plz make a video
@farazniaz2356
@farazniaz2356 4 ай бұрын
bus coupler do buss ko apas mai connect krta hai do chezoun k liye: 1) Agar ek transformer mai kaam chl rha hai ya maintenance ho rhi hai tou hum dosre incoming panel se bus bar motor ki bus ko couple krdete hain or pehle wale incoming panel ko decouple krte hain. 2) Bus coupler Synchronization k liye bhi use hota hai do buses ko apa mai sync krte hoye
@Ravanaravanar
@Ravanaravanar 4 ай бұрын
Sir wheen you say numbers values please say in english we are not understand numbers in hindi
@nitishnishad470
@nitishnishad470 4 ай бұрын
Please go English channel
@mohammedkhaleelkhan5880
@mohammedkhaleelkhan5880 4 ай бұрын
Is capacitor panel an LT panel
@farazniaz2356
@farazniaz2356 4 ай бұрын
Capacitor Panel LT or MV panel dono hosakta hai, Agar LT motor chalani hai or uska PF improve krna hai tou LT capacitor Panels lagte, issi trhn MV motors k liye MV Capacitor panels lagte hain
@abhishekmaurya2k
@abhishekmaurya2k 4 ай бұрын
Dear Sir, motor agar VFD thru chal Rahi hay Tho Uska Megger Kuy nhi lete aur Lete Hay Tho Kay hoga? Iska Ek Video Banayi pls
@farazniaz2356
@farazniaz2356 4 ай бұрын
Jab motor VFD k saath connected rhegi tou agar uska megger krienge tou megger sirf actual motor winding ki values nhi dega blke Vfd k internal component bhi megger ki values mai part le rhe honge. 2) Safety precaution k liyr bhi nhi krte megger kui k wo 500-1000 V tk mak motor ko test krta hai tou agar VFD connect rhega tou VFD ki circuitry kharab hosakti hai. 3) Agar megger krna hai tou VFD ko disconnect kr k krte hain
@sujitsutar4953
@sujitsutar4953 4 ай бұрын
Ek 11 kw motor ka full lode current 35 ampere hai,power factor 0.51 hai, power factor kam honese current kese rise hota hai...?? 🙏🙏
@farazniaz2356
@farazniaz2356 4 ай бұрын
Power (P) = 11 kW Voltage (V) = 3-phase system at 400V (common industrial voltage) Power Factor (PF) = 0.5 Current (I) = 35A at PF of 0.5 The formula for current in a 3-phase system is: I = P/sqrt{3} *V * PF Jab pf low hota hai tou current barhega inversely proportional hai, PF low hone ka mtlb hai k ziyada tar current useless kaam mai zaya ho rha hai(losses) tou usefull kaam shi nhi ho pa ra tou usefull kaam(motor efficiency barhane k liye) ko achi trhn krne k liye motor mazeed current leti hai. Tou jab jab pf los hoga motor ziyada current legi kisi bhi kaam ko poora krne k liye
@nk.indi11
@nk.indi11 4 ай бұрын
hello sir 🙏
@shrirambajiya6108
@shrirambajiya6108 4 ай бұрын
Sir mera siemen transformer ltd company selection huaa h kesi company h join karna chaye ya nhi
@kahaniya959
@kahaniya959 4 ай бұрын
Post kya hai, agar production me hai to maat Karo.
@ManojKumar-hc9pc
@ManojKumar-hc9pc 4 ай бұрын
Sir app ka mail id ho na sir please share me
@rajnishkumaryadav7291
@rajnishkumaryadav7291 Ай бұрын
Nice 👍
Interview Question On Relay| Relay Setting | Types of Relay| Hindi
9:43
Electrical With Abhishek Joshi
Рет қаралды 139 М.
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 41 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
Can we Connect Earthing in place of Neutral | Neutral vs Earthing | Interview Question
7:16
Electrical With Abhishek Joshi
Рет қаралды 268 М.
Why Star Delta Starter used in Motor
14:25
Deepakkumar Yadav
Рет қаралды 722 М.
Why Motor Start in Star and Run in Delta| Star delta Starter| Why Motor Connected in Delta
5:56
Electrical Thumb Rules| Electrical Cable Current Capacity| Electrical Important Formula|
7:54
Why Transformer Neutral Grounding || electrical interview question
9:41
Electrical Dost
Рет қаралды 621 М.
VFD Interview Questions Answers in Hindi | Learn EEE
14:04
Learn EEE
Рет қаралды 11 М.
How to do Megger of 3ph Induction Motor | Megger Mistakes | Motor Checking | Hindi
7:17
Electrical With Abhishek Joshi
Рет қаралды 39 М.