Why Shut Off Pressure is required for Control Valve Sizing | Control Valve Sizing | Instrumentation

  Рет қаралды 9,706

Core Engineering

Core Engineering

Күн бұрын

Пікірлер: 14
@Coreengineers
@Coreengineers Жыл бұрын
Watch more technical videos:🛠️👇 1. Industrial Engineering Videos: kzbin.info/aero/PLrqNx2OqGF51_BYmmF_z2TrR2x0EkVH3z 2.Industrial Pump Videos: kzbin.info/aero/PLrqNx2OqGF51IVvA2ivV1XdiMRnlWMLsC 3. Centrifugal Pump Videos: kzbin.info/aero/PLrqNx2OqGF513HW1AN7M9sw0kTqnO1ESX 4. Instrumentation Engineering Videos: kzbin.info/aero/PLrqNx2OqGF50F-gYBOccjSb9E-9F8zCi7 5. Piping Engineering Videos: kzbin.info/aero/PLrqNx2OqGF513CRbtuqu77IKBuIak9M3S
@mkbhuin6193
@mkbhuin6193 Жыл бұрын
I think the valve will remain open till defferential pressure is maintained 20 bar. Whenever there is a change in pressure either upstream or downstream the valve will close thus it maintains 20 bar pressure in the line. Is my understanding correct.
@manishankarraju5354
@manishankarraju5354 Жыл бұрын
Please make one video on different types of pump characteristic curves
@saikrishnasai2686
@saikrishnasai2686 Жыл бұрын
Sir please make a video on utility system ( offsites)
@GajendranGajendran-g8n
@GajendranGajendran-g8n 9 ай бұрын
Sir could you please draw the one p&id source to the destination to transfer the water as an interview poin mode. Including Nrv, reducer, strain, valve
@Coreengineers
@Coreengineers 9 ай бұрын
Sure
@chemicalengineer1985
@chemicalengineer1985 Жыл бұрын
What is criteria of accentric and concentric flange to control valve.
@Coreengineers
@Coreengineers Жыл бұрын
I have covered that topic in the reducer and expander video
@mohd.faisalbagban8242
@mohd.faisalbagban8242 Жыл бұрын
The valve may fail or get damaged due to the excessive pressure. This could result in leakage, which can be unsafe and lead to system failures.
@pranali6meshram707
@pranali6meshram707 Жыл бұрын
How to calculate shut off pressure of control valve
@Coreengineers
@Coreengineers Жыл бұрын
We will make the video soon about it
@pranali6meshram707
@pranali6meshram707 8 ай бұрын
Design pressure -downstream pressure am I correct
@infodailyhub2352
@infodailyhub2352 9 ай бұрын
please make videos in hindi🙏
@altafshaikh-vt6hq
@altafshaikh-vt6hq 6 ай бұрын
Control valve will not close becos the shut off pressure 40 bar is higher than 20 bar design oressure of the valve
List of frequently asked Control Valve Interviews Questions & Answers
18:28
Calibration Academy
Рет қаралды 21 М.
It’s all not real
00:15
V.A. show / Магика
Рет қаралды 20 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 61 МЛН
Equal % valves - Part 1 - What is the equation?
13:53
Process with Pat
Рет қаралды 17 М.
What happens when you mix different pressures?
7:43
Process with Pat
Рет қаралды 248 М.
Control Valve Leakage Class (ANSI FCI 70-2)
12:19
Asad (I&C Engineer)
Рет қаралды 3,9 М.
Control Valve Basics
32:50
Douglas Price
Рет қаралды 62 М.
Control Valve Sizing Made Simple | 3 Golden Rules
9:44
Asad (I&C Engineer)
Рет қаралды 17 М.
Control Valve's TOP 3 MOST asked INTERVIEW Question and Answers
14:25
Asad (I&C Engineer)
Рет қаралды 29 М.
How Valve Positioner Works | Hook's Law
6:54
Asad (I&C Engineer)
Рет қаралды 3,5 М.