Wiring a Hot Tub w/ disconnect and grounding electrode system for a 200A service in Oceanport

  Рет қаралды 25,746

Electrician Ron

Electrician Ron

Күн бұрын

In this video you'll see how a hot tub is wired using two branch circuits pulled through 3/4" PVC from an MLO NEMA3 exterior panel.
Classic Electric, LLC | Point Pleasant, New Jersey
License & Business # 16557
(732)-770-1437
Ron Pecina Jr. is a licensed electrician in the state of New Jersey. This allows him to apply for electrical permits, work with live conductors, remove meters, and disconnect service from the utility company. New Jersey observes the 2020 NEC and the Uniform Construction Code. The majority of the work seen here on this channel falls under the Rehabilitation Sub Code (Chapter 6 of the U.C.C.).
ALL New Jersey licensed electricians MUST complete 34-hours of continuing education units each tricentennial period. This includes a mandatory 10-hour code update course. Any work above 10-volts requires an electrical license in New Jersey.
Ron is an active member of the New Jersey Independent Electrical Contractors Association.
Become an NJ-IEC member here: www.nj-iec.org
IEC National: www.ieci.org
WANT TO SEE MORE? How to wire a Generac Standby Generator. WATCH HERE: • Generac Generator Inst...
Classic Electric, LLC is a Generac standby air-cooled generator installer. Generac Dealer # 1019500
Camera: Go Pro 9/ 10.
Editing software: Apple iMovie
Animation software: Apple Keynote
Like, Share, and Subscribe!
Electrical Wiring is NOT a hobby. Call a licensed electrician.

Пікірлер: 96
@NeonSphinx89
@NeonSphinx89 Жыл бұрын
As a layman, I'll do a lot of electrical work myself (don't worry, I'm a licensed engineer, my dad was a sparky, and I live in the county where I don't have to pull permits every time). But when it's something particularly hot/dirty/complicated I call an electrician. Every time I get the bill at the end and it's higher than I think it should be, then I say "well it was difficult enough that it was worth calling an expert. How much is my time and sanity worth? I don't have all the specialty tools to do this." And then I pay the bill because it's better than doing it myself. Worth every penny.
@peterd314
@peterd314 Жыл бұрын
I like that you label stuff. So annoying when people don’t
@vince6829
@vince6829 Ай бұрын
Nice job. Great workmanship. Thank you for sharing your knowledge.
@mattcregeen7724
@mattcregeen7724 Жыл бұрын
We core thru bottom of tub snd concrete, makes for a slick install . Out of sight out of mind. Keep up great work!
@electricalron
@electricalron Жыл бұрын
That wasn't feasible here.
@Pippy626
@Pippy626 Жыл бұрын
Love the videos. Quality work. If I was home owner, I would have had the conduit ran under and up the slab before it was poured
@garbo8962
@garbo8962 Жыл бұрын
Several times when I left a 2 to 4" studio in concrete the animals I stall in equipment slid heavy load across the PVC conduit breaking it off requiring time to chip out concrete inside of a tight space and pain in the butt to trim broken PVC to glue on a cooupling.
@Pippy626
@Pippy626 Жыл бұрын
true didn’t think of area with frost, I recently moved back to the north
@tommycho9068
@tommycho9068 Жыл бұрын
Always hard work pay off. Great job. Thanks.
@108electrical
@108electrical Жыл бұрын
This work isn’t easy, but if your willing to do it, the rewards are fantastic.
@javaman3765
@javaman3765 5 ай бұрын
Hot spring and Caldera are the only hot tubs using this 20A/30A breaker and 6 wire run.
@norsk54472
@norsk54472 Жыл бұрын
My city here in Utah uses PEX for incoming water lines. When I replaced the old galvanized pipes in this 80 yo house, I installed all copper. When the city side galvanized water pipe finally died, PEX was installed. I still ran a grounding conductor to the internal water pipes
@electricalron
@electricalron Жыл бұрын
This house was built in 1920.
@norsk54472
@norsk54472 Жыл бұрын
@@electricalron I call our house "My Old House". It has been fun upgrading so much of the place over the past 28 years. Very intimate with it now. It is my hobby now
@iandrew6347
@iandrew6347 Жыл бұрын
Great video Sir watching from the U.K.
@electricalron
@electricalron Жыл бұрын
Glad you enjoy them!
@jeremyjpegan
@jeremyjpegan 2 ай бұрын
Interesting there were two circuits going into the hot tub panel. One was for the pump and the other for the electronics?
@camheady235
@camheady235 4 ай бұрын
At 12:16 you mention you don't have to land the neutral on the GFCI breaker. Did you land on the neutral bar? Why would the GFCI breaker have a silver neutral terminal on it? And the GFCI neutral pigtail gets uncoiled and trimmed to proper length and landed on the panel neutral bar as you mentioned. With QO plug-on neutral breakers, there is no coiled pigtail of course, but I would land the neutral on the breaker. Greetings from Belmar. Thanks for your content.
@user-nz5op6rd4u
@user-nz5op6rd4u 3 ай бұрын
I love the hammer mileaukee m12
@Demy26
@Demy26 Жыл бұрын
Love your work
@electricalron
@electricalron Жыл бұрын
Thank you!
@arnieselectric007
@arnieselectric007 Жыл бұрын
Super cool Ron, thx brother...😃😉😎
@FrontRowOrBust
@FrontRowOrBust Жыл бұрын
I was JUST wondering when there would be a new upload🎉
@electricalron
@electricalron Жыл бұрын
I try to upload when I can. My wife was hospitalized over the holiday weekend and it set me back a little bet. She’s healthy now but it was stressful 5-6 days.
@FrontRowOrBust
@FrontRowOrBust Жыл бұрын
@@electricalron glad she’s doing well Ron. Keep up the good work⚡️⚡️
@electricalron
@electricalron Жыл бұрын
@@FrontRowOrBust thanks FROB!
@mcarroll598
@mcarroll598 Жыл бұрын
Hey Ron nice video. Just curious, would that pad for the hot tub have a ground wire back tot he disconnect panel to bond the wire mesh or rebar to keep everything at the same potential?
@electricalron
@electricalron Жыл бұрын
There's no Ufer ground here and I agree, there should be one because the tub is a separate structure.
@Bob.W.
@Bob.W. Жыл бұрын
Why do new episodes come just as I am going to bed? Lol.
@electricalron
@electricalron Жыл бұрын
I edit and upload when I can. I'm trying to get ahead of the curve and have a few videos "in the tank" and on a schedule for release but I haven't got there yet.
@On1Electric
@On1Electric Жыл бұрын
You’re the man! Keep it up!
@aaron74
@aaron74 Жыл бұрын
A lazier and faster install would be to just run carflex the whole way back to the panel under that porch/deck, but you did all those PVC bends for a much more durable raceway. Can you only use carflex a maximum length by code? I agree those terminals on the control board look flimsy when you consider the tub heater and jets draw such high current. Hopefully those springs are good and tight or there could be arcing. And that connection needs to stay tight through the year-around outdoor seasons. Seems normal screw terminals would be cheaper and safer. Man it looks like there's some money over there in Oceanport. You're lucky to have great clients.
@electricalron
@electricalron Жыл бұрын
I prefer terminals all day long but I am a fan of using Wago's where necessary.
@aaron74
@aaron74 Жыл бұрын
​@@electricalron Oh yeah those Wago lever nuts are amazing. Keeps the conductors nice and clean if you need to add/remove conductors to a splice
@electricalron
@electricalron Жыл бұрын
@@aaron74 Aaron, are u an electrician too?
@aaron74
@aaron74 Жыл бұрын
@@electricalron Mostly vicariously... it's an avocation. I'm a landlord and do DIY electrical work on my property. I love the trade, and probably should have been if I could rewind my life. I'm a stickler for doing the work perfectly and making it as good as a pro did it. I help a lot of people on forums figure out circuits.
@jeremyjpegan
@jeremyjpegan 2 ай бұрын
Yes, Captain Ron, why did you not run the flex under the deck?
@nope_not-showing-my-name
@nope_not-showing-my-name Жыл бұрын
Nice work. I would be a little concerned that there is no siding behind/around the transfer switch and the weather protection is exposed.
@electricalron
@electricalron Жыл бұрын
The homeowner who's a friend of mine was aware of the situation and said he will address the siding at his convenience. I offered to put a large piece of Azek behind all of it but he declined.
@christjerky2320
@christjerky2320 9 ай бұрын
Dude… are you sponsored by Milwaukee.😂 Nice work. Around here we call it core line.
@zekenzy6486
@zekenzy6486 Жыл бұрын
Great Video. Thank you for sharing
@electricalron
@electricalron Жыл бұрын
Thanks for watching.
@YaksAttack
@YaksAttack Жыл бұрын
Hey Ron, I'm a young electrician in south Jersey, love watching your videos and seeing someone who knows what they're doing. Maybe you've shown it in another video, but what do you typically use to heat your PVC for bending? Your bends look really good. I was thinking of buying one of those greenlee blankets, but theyre expensive, and wanted some other opinions before I pull the trigger.
@electricalron
@electricalron Жыл бұрын
Glad you enjoy the videos and I hope you are learning a thing or two. I use a Greenlee 2” heater and it cost $400 in 2014. The blanket works well but takes longer. You could also use a charcoal grill because the heat would most definitely warm the PVC. I did that once working at a friends house up on Cape Cod.
@johnstrh1
@johnstrh1 Жыл бұрын
@@electricalron I have the same heater on my truck and I am finally starting to get really good at bending offsets and 90's with it. It is such a useful tool for a resi electrician and it sure ebats having to run out and grab a pre fab
@YaksAttack
@YaksAttack Жыл бұрын
Thanks guys. Right now I work for an electrical contractor, and while the hot box seems great, I don't think I'll buy one to keep on my truck. But I might buy one and put it in my basement at home for the meantime lol
@arnieselectric007
@arnieselectric007 Жыл бұрын
@@electricalron ...ya do whattcha gotta do...lol
@garbo8962
@garbo8962 Жыл бұрын
In shore town Stratmere NJ ( just south of Ocean City ) the water meters are on !awn maybe 12" below the ground. My buddies house water meter would have have an inch if water on it spat high tide. He is third house off the beach .We are not allowed to use aluminum for ground ding any services. Nothing beats copper for a reliable longest lasting most reliable ground conductor.
@electricalron
@electricalron Жыл бұрын
I haven't even seen where the water meter is on this property but I can find out.
@bigtroll8249
@bigtroll8249 7 ай бұрын
Why did you use a 60A breaker to supply the hot tub panel containing 2 breakers totaling 50A?
@electricalron
@electricalron 7 ай бұрын
Cus I felt like it
@bigtroll8249
@bigtroll8249 7 ай бұрын
@@electricalron sweet!
@AK-oz4ew
@AK-oz4ew 8 ай бұрын
That existing deck that is closer than 5 ft - does it require equipotential bonding? Also the concrete pad under the hot tub - does it have a bonding wire? Sorry if I missed it, but I didn't see 8 awg solid copper anywhere. Thank you
@thespookyringmaster6719
@thespookyringmaster6719 11 ай бұрын
Hi Ron, what would you do if a hot tub were to be placed on existing concrete? Bonding? Grounding? Not sure it's possible to do an equopotential bonding loop at this point without breaking up the old concrete. thanks!
@electricalron
@electricalron 11 ай бұрын
If it’s an existing concrete slab the code specifically states that you do not have to break up the concrete to get to the rebar for grounding.
@thespookyringmaster6719
@thespookyringmaster6719 11 ай бұрын
then how do you ground the rebar? or don't you? what about equopotential bonding? there is only about 10 inches all around the hot tub of exposed concrete. it's about 12" from the edge of my deck also. TIA@@electricalron
@TKomoski
@TKomoski Жыл бұрын
What's your tolerance on determining what AWG size you use +/- 5 amp or more. How far would you bring an aluminium conductor into a building?
@electricalron
@electricalron Жыл бұрын
Conductors are sized for the loads they serve Circuit breakers are sized to protect the conductors, not the equipment.
@boyd191
@boyd191 Жыл бұрын
Hi Ron, thanks for all the content. Would you want to use a rain tight hub on the ATS since you're in the upper part of the enclosure.
@electricalron
@electricalron Жыл бұрын
I'm not overly concerned about it. As I tightened up the locknut on either side I squeezed some silicone in there to make it water tight. I will however check it before all of the work is done over there.
@bigtroll8249
@bigtroll8249 7 ай бұрын
I was thinkin the same thing. U read my mind
@Daltoncom
@Daltoncom Жыл бұрын
Opinions on using 2 hole plastic straps on pvc vs using 1 hole rigid straps on pvc?
@electricalron
@electricalron Жыл бұрын
Well the 2-hole PVC straps are what you're supposed to be using on PVC. I do use heavy wall 1-hole straps but being that this house is close to the salt water the HW strap would rust in short order.
@DonWess-hc6pc
@DonWess-hc6pc 5 ай бұрын
Other good one Ron. 👍
@JBernhard72
@JBernhard72 Жыл бұрын
@11:05 what is your torque settings for those spring terminals? SMH on a 30A circuit!
@eggplant2369
@eggplant2369 Жыл бұрын
Do you need schedule 80 pvc for exterior runs?
@Jeff-xy7fv
@Jeff-xy7fv Жыл бұрын
Great job! How much do most electricians charge for a project like that, ballpark?
@electricalron
@electricalron Жыл бұрын
$2000-$2500
@Electronman220
@Electronman220 Жыл бұрын
how do you make the offsets for the pvc
@nevrbdwnruby7484
@nevrbdwnruby7484 Жыл бұрын
Wouldent inspectors call you out 5 current carrying conductors on that pipe for the tub? (adjustment factor [no more that 3 current carring conductors?])
@electricalron
@electricalron Жыл бұрын
No, because five conductors in the same raceway is not a violation. Derating is something else entirely. All THWN/ THHN conductors have different ampacity ratings and the 90º column of Table 310.16 is used when derating conductors.
@scottboyne8305
@scottboyne8305 Жыл бұрын
Hey Ron loved the video but what kind of spa uses only 20amp and 30 Amp breakers
@electricalron
@electricalron Жыл бұрын
Before spas used to use 50-60 amp circuits. Now it’s just broken outside of the unit.
@scottboyne8305
@scottboyne8305 Жыл бұрын
@@electricalron ok. Didn't know that. I wired my own spa and had to use 6 Guage wire for 50 amp
@michaeljennings5170
@michaeljennings5170 7 ай бұрын
Al and brass will be a problem.
@robertberman3266
@robertberman3266 Жыл бұрын
Great work. what kind of side pliers do you use.
@electricalron
@electricalron Жыл бұрын
7” Klein hybrid.
@joshman2338
@joshman2338 Жыл бұрын
nice little job and well documented. This is a good example of how PVC can be easier and better than EMT. Did you end up using a PVC heater bender under the deck?????
@electricalron
@electricalron Жыл бұрын
I used the PVC bender outside of the deck
@theseattlegreen1871
@theseattlegreen1871 Жыл бұрын
What did you charge? How much profit did you make?
@electricalron
@electricalron Жыл бұрын
Why do you need to know that?
@bigtroll8249
@bigtroll8249 7 ай бұрын
​@@electricalron right? Whats this guys deal? Hes probably a homeowner trying to chizle down his electrician. Typical miser.
@thomasmickelson6759
@thomasmickelson6759 Жыл бұрын
Never seen one like that . Usually they take a 50 amp or 60 amp circuit
@electricalron
@electricalron Жыл бұрын
The new ones seem to be different. Not sure for the reason for the change.
@Elt31987
@Elt31987 8 ай бұрын
👏
@cadentheis
@cadentheis Жыл бұрын
Would you ever consider filming in 4K?
@electricalron
@electricalron Жыл бұрын
I record in 5k on a Go Pro!
@braytonhackbarth
@braytonhackbarth Жыл бұрын
6:00 every tool has a hammer side
@electricalron
@electricalron Жыл бұрын
Absolutely.
@edwardvyrlan
@edwardvyrlan Жыл бұрын
why doesn't the meter have a seal
@electricalron
@electricalron Жыл бұрын
Because I broke it to do work.
@RonPecinaJr1437
@RonPecinaJr1437 10 ай бұрын
ok
@RedPillLife1966
@RedPillLife1966 Жыл бұрын
Dirty Hands, Clean Money
@electricalron
@electricalron Жыл бұрын
Hell yes brother!!!
@1percentSolutions23
@1percentSolutions23 9 ай бұрын
Hey I love your work, would love to shadow you one day. Lunch on me 🥪
@AnActualCoconut
@AnActualCoconut Жыл бұрын
No lol
Hot Tub Wiring (An Incomplete Video) | Oceanport, New Jersey
25:06
Electrician Ron
Рет қаралды 7 М.
An Unknown Ending💪
00:49
ISSEI / いっせい
Рет қаралды 34 МЛН
Angry Sigma Dog 🤣🤣 Aayush #momson #memes #funny #comedy
00:16
ASquare Crew
Рет қаралды 50 МЛН
This Old Panel had WAY TOO MANY Circuits!
33:11
Electric Pro Academy
Рет қаралды 19 М.
Upgrading an electrical service from 100A to 200A | Clark, New Jersey
27:57
Emergency Service Call in BFE - QUICK ELECTRICAL SERVICE PANEL SWAP
21:30
Full Hot Tub Electrical Install - Start To Finish
1:21:18
Electric Pro Academy
Рет қаралды 222 М.
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,3 МЛН
How I wire a panel (an in-depth tutorial)
9:57
Karly the Sparky
Рет қаралды 1,4 МЛН
Buying A Hot Tub - From Building a Pad to Electrical
14:56
My Boring Channel
Рет қаралды 154 М.