One thing you shouldn’t do is disconnect your battery from the charge controller and leave the panels plugged in. When I service my batteries I always throw something over the panels to block the sun. If you don’t do this you risk overheating the controller
@Scott-ig1zd11 ай бұрын
You will fry the charge controller.
@brianhamelin668411 ай бұрын
Nice. It's a haul, sometimes. You're good at it. Hilarious that all vid after 3:30 is like black screen and headlamp. I live in northern NH in my camper. I get it. Hang in there
@ryanthebarber11 ай бұрын
A surge protector is needed for the 12v system or it will overload fuse panel and cause sparking fire
@niemma211 ай бұрын
Yeah on MPPT chargers you need disconnect panels first before disconnecting battery from charger or high probability you will damage charger.
@Charlie-do6wv9 ай бұрын
You just need a breaker setup so when you need to you can disconnect your input power/panels from the circuit.
@The_Somewhat_Handy_HandyMan11 ай бұрын
Super simple optimal solar panel angle...empty can set on solar panel glass, now simply make the can shadow disappear. Remove can.
@Greystone18 ай бұрын
That panel on the roof needs to be angled, too. The further north you are, the higher the tilt should be. You might be better off with the panels near vertical. As a bonus snow/leaves/dirt won't gather on a vertical panel, so less maintenance.
@torotom624310 ай бұрын
I think you need a small wind generator that hooks up directly to the batteries that will give a little extra charge and get you over the bad times
@theMekanik11 ай бұрын
Lower Oktane 87 Runs better in Gen Sets. Generator are not High Kompression Engines Like in Korvettes…. Korvette Engines Rquire 91 + Oktane.
@budwilliams659011 ай бұрын
I have always run regular in everything and never had a problem. I have a 20 year old Craftsman lawn tractor that I still use to plow snow (deck was shot so I got a John Deer for mowing) never had trouble with it.
@rookm1311 ай бұрын
the grade of fuel doesn't really matter if the station still advertises ethanol content. There are stations that have no ethanol which is the major difference. Running supreme on anything other than a "performance" engine that requires it because of their compression ratio, is literally just igniting money.
@MaritimeUnprepared7 ай бұрын
I, like you have been around for a little while. Ethanol is a good thing as it binds with water making gas line antifreeze obsolete in most cases. The real problem is when you store your small engine with Ethanol gas in it. I've always drained my gas before storing equipment and things are fine.
@christinamillikin31111 ай бұрын
I always used premium for my small motors because it kept over winter and I didn't need the fuss of draining. Ramsey reminds me so much of my cat Winston miss him very much. You are doing so well with figuring things out. I bet your family is very proud of you.
@gypsyjenna11 ай бұрын
Thank you so much 😊
@rookm1311 ай бұрын
@@gypsyjenna Sorry if youve seen it but i think this is crucial, your ecoflow can accept charge from your solar panels too(built in MPPT). Thing ive been meaning to ask but was watching your past videos to make sure it wasnt mentioned before, whats the ah and voltage rating on the batteries?
@benjamincresswell371311 ай бұрын
Read the directions. They usually state pretty clearly what grade gas and what percent ethanol. I have never seen a generator ask for more than 89 Octane rating R+M/2. Most state 87. And never any more than 10% ethanol. Unlike nowaday cars a generator cannot compensate for etoh in the fuel and putting in even 10% etoh forces it to run leaner. Etoh absorbs so much water it will rust steel parts if you leave it in long term. ben/ michigan
@Step-n-Wolf11 ай бұрын
Premium has nothing to do with over winter. Use Stabil or drain the gas and use it in something else.
@scable-eq7bp11 ай бұрын
Hi Jenna, as always great content. Seems like when you're off-grid something is always crapping out at the wrong time, but when you have no mortgage, no over priced homeowners insurance, and no utility bills, it's an even trade off.....
@gypsyjenna11 ай бұрын
Definitely!
@michaelbrinks808911 ай бұрын
@@gypsyjennaRegular 87 gas is fine for your generator or lawnmower unless it says otherwise...You did nothing bad using 87 octane...Most generators & lawnmowers are made to run on 87.....A higher octane 91 won't hurt it but is throwing money away.....If your scooter said use only 91 or higher. Then it was a higher compression engine. Like my motorcycle that needs 91 to prevent engine knock at high rpm. Which is pre ignition/auto ignition and very bad on an engine. Your generator is 100% fine on 87 unless it says otherwise....91 doesn't burn cleaner and isn't any better quality. It's just higher octane made for higher compression engines. I posted a longer comment about it and ethanol gas in the comment section. If you have a few things that run on 91 & a few that run on 87...It's easier to just buy 10gal of 91 and use in everything 🆚 separate containers of 87 & 91. But then again 2 containers is easier to carry. I hate having multiple 2 stroke tools that require different gas/oil ratios. Snowblower 50:1 bike 32:1 chainsaw 40:1....I run 40:1 in snowblower I think 50:1 is just too little oil.
@bennym195611 ай бұрын
Retired and house/ land paid for ! Wouldn't trade places with her nor would most of commentors if you're honest about it !!!
@shelbyburgey88411 ай бұрын
I can't wait for your video to start off with, "nothing is broken today" lol I feel your pain! My furnace is in need of a new part and no one feels the need to hurry up with it! Hope things get better soon. Have as good of day as possible!
@TIsunshineOffGrid10 ай бұрын
I'm so glad I came across your channel!!!I live the same way here in New Mexico. With my 2 dogs, Gypsy and Honey. I'll continue to follow you. I have only been off grid since April 2023 Definitely going through it dealing with the leaky camper generator issues comma that I finally hopefully got resolved. Working with the buddy heater inside. Frozen water the list is never ending however I still love my new life!
@gypsyjenna10 ай бұрын
Always something eh, keep on rockin it! 🙂
@finnna835211 ай бұрын
Two comments, the charge controller might have an internal factory reset button that might help also try tech support before condemning the charge controler. The generator... two ideas come to mind, one is that your generator might have a sensor in or on the muffler to sense if it's getting too hot. When you load up the generator it makes more heat thus the muffler gets hotter. It might be faulty and shutting it down. Also, some generators have an oil switch, you might have enough oil in the unit, but a faulty low oil switch could be shutting you down.
@ericwitt4586Ай бұрын
Always hook the batteries up FIRST and then the rest panels ect.
@showaltermicro11 ай бұрын
You can hot charge your batteries with jumper cables and your running car.
@preparedneverscared88578 ай бұрын
Got me dying at the high pitched "ah jesus christ" 😭
@gypsyjenna8 ай бұрын
🤣😂
@dcore645 күн бұрын
Me too. Hahaa
@jonperry997911 ай бұрын
One thing you can do on a generator is be sure it is not low on oil check the oil a lot of generators have an automatic cut off. If they’re not low on oil, they won’t start or they won’t run.
@carld318411 ай бұрын
In that video about lithium batteries he makes at least one point that may be applicable to your gel battery bank, he says that if you connect the positive cable going to your camper to the last battery in the chain then the negative cable should be attached to the first battery. He claims that even the small resistance from the jumper connections between the batteries adds resistance and if both cables are on the last battery in the chain then it will do more work therefore his suggestion to put the positive snd negative cables st opposite ends of the battery bank. Worth a try!
@garymcmullin229211 ай бұрын
lots of comments and desire to help you but I bet it starts to make your head spin with the diversity of suggestions. One in particular I keep seeing is suspected water in the fuel and dirty carburetor. Water from condensed out of the air in the tank or from ethanol absorbing it over time is going to do its nasty thing on start up, because water settles to the bottom of a tank owing to density properties. The engine may not want to start or sputter a lot for a few seconds or more then smooth out as the water is ingested and the water free gasoline finally feeds the carburetor. If you had a dirty carburetor you would have definite symptoms of hard starting, flooding and such and it would not go away. Your generator engine carburetor is doing fine for now. I would want to do a change out or rebuild it in the summer season. Installing a new replacement would be easiest for you, then you could opt to buy a rebuild kit and refurbish the old one to have on hand as spare.
@MaritimeUnprepared7 ай бұрын
The funny thing about ethanol is that it binds with water making gas line antifreeze obsolete in most cases. If you are old enough to remember pre-ethanol days you may remember the problems with water in gas or "bad gas". In my humble opinion ethanol is a good thing, but you must take certain precautions with small engines that get stored for long periods otherwise they can get gunked up
@trentcarbino92111 ай бұрын
Awesome that your generator is up and running. Good to have friends that are willing to help out.
@harlanmclain171911 ай бұрын
That's what friends are for lol 😹
@SuperHurdman11 ай бұрын
Here is something for you to try! Take your inverter power source and fully charge it! hook up your battery charger to it and start charging your batteries! also hook up your battery charger to your inverter You may be able to make a loop and have it go further may have to get a second charger one for the batteries and one for the inverter! also why not take the extra three batteries and hook them up in series with your existing batteries this way it will give you a longer run time as you will have more battery capacity.
@ericwitt45865 күн бұрын
Hey girl as much as you deal with the batteries as comes with off grid living I do it too at my office grid cabin please wear some safety glasses I was an air technician for 20 years I had two batteries blow up and it’s bad if you’re not wearing them it burns bad enough on your skin girl it will blind you if you’re close enough to them you have beautiful eyes and face , hair and all that goes with them so please wear them Jenna I never thought that batteries blow up while I was working on them but it does happen when the gasses are present and a spark happens 😀😎👍
@leemalvin773111 ай бұрын
If you disconnect the batteries, while the solar is still plugged into the charge controller, it can fry the charge controller.
@dalefackler872611 ай бұрын
Thank you for the videos, glad your generator is working.
@gypsyjenna11 ай бұрын
Thanks so much 😊
@xlamontx11 ай бұрын
Hi Jenna. I once fixed my no start issue with my generator with a new spark plug. I guess when an engine only has one spark plug, it becomes important to its ability to function properly. Glad you got that sorted.👍🏾
@jeffreykropp766411 ай бұрын
Costs more, but non-ethanol gas is better for small engines. Also, fiddle with solar electronics at night for safety. I eventually bit the bullet and acquired lithium batteries to replace my 13-year old (!) golf cart batteries.
@gypsyjenna11 ай бұрын
13 yrs!? Wow those were some lotlysl batteries! I hope you replaced with the same ones! 😊
@artpatronforever11 ай бұрын
Glad to see you have power again. Never saw a spark plug fail that way. It is likely a defective plug from manufacture or rare type plug failure. Plug fouling is often a problem. Regular gas is fine. Non ethanol is the best but not worth the added cost for a frequent use generator like yours. The battery charger is your weak link there at 25A and 12.9V is only using about 10% of your generator rated full output available. So it is better to charge using an RV power converter - battery charger of 100A to reduce the run time for your generator by two thirds what is required now. The fuel used by the generator to charge your batteries would be much less.
@gregorykucera423511 ай бұрын
Great video, I used to get tired of charging batteries all the time when you put new batteries I would double the amount that you were going to do that is what I did I never charge them even on cloudy days it's better to have a big battery bank far more than you would ever need, Thanks for the great video 😊
@mobjackcalling856811 ай бұрын
I do relate second winter off grid second homestead on a kY ridge top Ty Suvscribed
@musicvibes01710 ай бұрын
Hi Jenna, new subscriber here and I am an experienced person living off grid now for 4 years. Sometimes the generator will kick off due to lack of oil. There is a safety mechanism built into generators that prevents engine damage from low oil, should also try and change the oil every 100 hours of use on a generator. Enjoying your content thank you for sharing your world with us.
@kimmogensen539011 ай бұрын
when you mess with your batteries you do not need to disconnect your batteries from the chargecontroller , however every time you disconnect your batteries you always have to disconnect your solar panels as there is no where for the energy to go (you could add a dc breaker on the panel wires if you need) if your model have a fuse it could just be blown (diode ? good repair you can also messure on the batteries or the terminals on the controller if you have charge comming trough) , i am offgrid in Denmark(as my house burned down last year) and sitting in my caravan in the snowy weather and for the first time in a month have had 2 days with a bit of sun in a month,,and i have been trough days of failure opon failure ,the only thing that matters is to keep solving the problems and you shine at that, so good work and enjoy the beer.....
@gypsyjenna11 ай бұрын
Thanks and I am so sorry about your home. I hope the winter is good to you
@kimmogensen539011 ай бұрын
well i have heat and food. a bit of entertainment and a cat for company so winter is treating me well @@gypsyjenna
@ericwitt45862 ай бұрын
Use Stabil gas treatment it kills the ethinol if you have to use that type of gas I do in my generators I got two 1 at my off grid cabin and one for my house here I case of power outages I’ve never had a gas problem Jena it’s great for storing gas too , mostly at my cabin I use my 2000 watt solar generator with 2 -100 watt solar panels to keep it charged up while using it lol I have the predator brand 4500 watt generators from harbor freight there a good generator I have had hardly no issues with them 😀👍
@CoffeeZombie7008 ай бұрын
Lord I love your videos. Just love love love lol
@462ANIMAL11 ай бұрын
I’ve never had a spark plug do that on a small engine.. lol I never use premium gas in any of my small engines other than the chainsaws. I’m way too cheap to burn premium in a lawnmower or snow blower. Lol gas prices are at 1.449 here ..and it’s snowing like crazy ,
@Jeg_er_tyk_og_grim9 ай бұрын
Regular gas is fine as long as its 87 octane, Anything else is a waste of money and can actually give you more problems beecause supreme is a low-knock fuel. If you are concerned about the fuel you want no-ethanol but it seems that you run it often enough to not worry about the effects of ethenol
@GregoryTodd-k9r11 ай бұрын
Jenna, if you removed the batteries from your controller and left the solar input connected, then you may have damaged the controller. One should ALWAYS connect your batteries first to the controller before a solar input is connected. NEVER have the solar power coming in with NO BATTERY connected to the controller. By the way I think I have the same model controller in use at my house. I'm a old Newfie but I now live in Colorado Springs. Great videos!
@gypsyjenna11 ай бұрын
Thanks, hope you're enjoying CO!
@NYCamper6211 ай бұрын
Never hurts to have a backup controller. At least this happened now instead of middle of winter. Cheers.
@miriamharty576111 ай бұрын
Glad you got sorted. What a cute pretty visitor you had. I think the walking around in circles was telling you "I am hungry".
@gypsyjenna11 ай бұрын
100%! Haha
@OurCabinInThewoods11 ай бұрын
Woohoo I have never seen a plug break like that and I was a auto tech for 24 years. 5 stars to your friend very nice. Getting that control back on should get you almost 100% back to normal. Great video Jenna you need to buy your friend 6 pack just put it on my tab lol.. stay warm
@gypsyjenna11 ай бұрын
Yes, I do! He geared me up with two spark plugs and a fuel filter and took the charge controller apart. Guess I owe him some beer!
@OurCabinInThewoods11 ай бұрын
@@gypsyjenna yup
@OurCabinInThewoods11 ай бұрын
I seen the side-by-side gone from the wood shed. Did he finally take it home?
@gypsyjenna11 ай бұрын
@OurCabinInThewoods I moved it out if the wood shed to finish piling the wood lol
@XCX23710 ай бұрын
My electricity teacher always said that all electronic equipment came with smoke in it. Just don't let the smoke out and your ok👍 great Video Jenna, thank you 😊
@norm578511 ай бұрын
Jenna, wonderful problem assessment and solving. Thank you for sharing, everyone stay safe, warm, happy and healthy. From Henrico County Virginia
@rcf836711 ай бұрын
Great find on the broken porcelain in the spark plug center electrode! Glad that no pieces made it into the engine.
@gypsyjenna11 ай бұрын
Phew, me too!
@donm384411 ай бұрын
I wondered if you ever considered another small generator just for emergency , it would be just to charge your battery's in case your big generator goes down, I bought a small 1000 watt generator on amazon for emergency battery charging myself in case my large generator goes down ,mine is called a ALF 1000 GENERATOR, it's a small 4 cycle engine and is propane powered and is really fuel efficient, i can run mine on a grill tank for 24 hours if needed and comes in handy for charging my eco flow delta or small items in and emergency. I think mine ran around 300 dollars but was well worth the money so far, I know from experience you always need a backup plus a back up for your back up when possible.
@gypsyjenna11 ай бұрын
True that!
@ericwitt4586Ай бұрын
You need a light meter I’ve got two if you ned one let me know it works in standard and metric so there you go lol it helps with optimum best sunlight positions for solar panels
@donaldanderson188111 ай бұрын
You need ethanol-free gas, not premium. The alcohol is bad for small engines. Premium is a higher octane that you do not need. You can add Sta-Bil for storing fuel.
@bitzclipsmatt21411 ай бұрын
Its good that you have people around you to help you out. Love that you have ago yourself though. Have you looked into getting your Ecoflow hooked up in a way so you have supply 12v to all your lighting and shower should you need to. It would have more than enough power to do this for you. 😀
@gypsyjenna11 ай бұрын
I haven't yet but that does sound interesting 🤔, hmmm thanks!
@johnjaco554411 ай бұрын
I run my generator on propane,it's an easy conversion.Runs cleaner than gas,and easier to store,propane doesn't go bad like gas.
@db.mc211 ай бұрын
Hi Jenna 👋🏻 good to hear things are looking better for all the issues you've been having 🤞🏻Hope the rest gets sorted out ok🙏🏻Stay safe and take care my friend 🙂 Appreciate you!
@acidreign855111 ай бұрын
Glad you found some of your gremlins. Crossing my fingers and sending good vibes your way for no more of them for a while. You need a break from them!! Be safe up there!🥰🙏
@gypsyjenna11 ай бұрын
Thank you 🙂
@dubrd592610 ай бұрын
Hi Jenna, I am sorry you are having trouble with your solar setup. I am not sure how you are using that modified extension cord but an extension cord is made to extend 120VAC. Even though it can be used to connect DC if you know what you are doing, it's wires are designated so that they are connected to the hot side and the neutral (grounded) side of the AC circuit not as positive and negative. In no case plug that cord into an AC outlet if you are connecting it to DC or you will burn something out. If you wanted to test the charge controller to see if it is working you need a volt or DC amp meter. If you only have a volt meter. Disconnect the solar panels from the charge controller by tripping its breaker and measure the battery voltage. Now turn on the breaker connecting the solar panels to the charge controller. If the charge controller is working the battery voltage will rise to a slightly greater voltage. If you have a DC clamp on amp meter you can clamp it around one of the two wires going between the battery and the charge controller. If the charge controller is working and the DC clamp on ampmeter has a low enough current scale it will measure a DC current from the charge controller to the battery.
@denisnedelec115911 ай бұрын
Last week had a lot of problems ,this week solutions !!🔆🔆🔆
@gypsyjenna11 ай бұрын
Yeeehawwwww!
@seanstokes638327 күн бұрын
We use Stihl oil mix and non-ethanol fuel in everything we have, with ZERO problems. We use it in our power tools at our Volunteer Fire Dept as well. No problems whatsoever. Just something you may want to consider
@LRhiannon110 ай бұрын
I live in north east PA..our gas stations have a pump with a white handle…that gas is for generators..golf carts etc… I can’t remember what they call that gas…but it doesn’t clog or evaporate fast
@stevenfrazier893911 ай бұрын
Diodes are one way electrical valves. Could have prevented the battery from connecting properly. Also Epever are slow at tracking the Maximum Power Point. MPPT controllers made by SRNE are faster. Ask BougeRV to let you review one of theirs. They are made by SRNE. Sponsors can be a great asset for your channel.
@joeclark904211 ай бұрын
I'm glad you got it fixed sweetie good job
@magickmike651011 ай бұрын
How does Jenna onlly have 12.4k subscribers? She works hard to put out amazing content, give her some love people
@jamespeters92011 ай бұрын
Wow, that's a first for me. Spark plug fouling out like that. That generator must vibrate like crazy. Charge controller in hand, things are looking up!
@williamdykstra185711 ай бұрын
When your generator wears out I suggest you get a Honda, I had one for many years and it always ran well and started easy.
@bobf1211 ай бұрын
you need non ethanol gas for all small enjines. do not use anything with ethanol. It will screw them up.
@Greystone18 ай бұрын
I'm thinking with a few relatively easy changes we can greatly improve your electrical system. Here are a few suggestions: Step 1: Run a set of light duty battery cables from the battery bank to the battery on the generator, making it the 4th battery in the group. Step 2: Connect one of the spare batteries to the group, making it the 5th in the battery bank. Step 3: Connect the battery charger to the generator battery and plug it into the 120V outlet on the generator. When you start the generator it charges all 5 batteries at once and it should last much longer between charges. Step 4: Connect the 300W inverter to the battery bank. Step 5: Disconnect the 30A hookup cord from the generator and plug it into the 300W inverter. You can now run everything in the trailer, both 120V and 12V.
@Greystone18 ай бұрын
This brings us to the secondary system: Step 6: Move the remaining battery to the rear compartment where the water tank lives. Step 7: Connect the remaining battery to the controller for the small solar panels. Step 8: Connect the small panels to the controller. This is the battery that powers the water pump
@Greystone18 ай бұрын
EcoFlow: Step 9: Keep the ecoflow charged by plugging it into a 12V socket inside the trailer. This is your portable spare system. Take it with you when you go 4-wheeling out in the woods, along with an electric blanket... just in case. It will keep your phone and camera batteries charged and keep you warm as well.
@gypsyjenna8 ай бұрын
Thanks for all of the info! I appreciate it!
@rmhanseniii11 ай бұрын
You’re absolutely right….i’m cringing to the point where I might implode
@dennisrapach285711 ай бұрын
You are amazing...Get a battery charger with temp senor charging running off of the generator. Battery's need to be charged at a higher voltage at lower temps. Also get a solar charger with MPPT tracking. it will charge more current with temp control. Those changes will charge more power in a short period of tame.
@ryancaesar554711 ай бұрын
Never disconnect the batteries from a controller while the solar panels are connected because that can blow up the controller
@philmccumbee693811 ай бұрын
Can’t remember if I have commented. I sure hope the plug fixes your generator. Hang in there until you get everything fixed. But, things break all the time as you well know. Glad you have a friend that can help you some.
@gypsyjenna11 ай бұрын
So far so good with the spark plug change!
@ryanthebarber11 ай бұрын
We have used a small cast iron skillit on low all night on propane stove, careful not to burn up all oxygen
@tedhart446811 ай бұрын
It helps if you cover the solar panels at night you know it’s going to get frosty and uncover them when the sun is out kinda like your windshield if it’s going to snow or be freezing rain it’s so much easier to keep them clean and charging keep on keeping on !
@todddewell631411 ай бұрын
Glad you made some progress on your projects!!
@nunya886611 ай бұрын
Awesome living, wish I could get in that situation.. Best of luck with everything!
@gypsyjenna11 ай бұрын
Thank you 🙂
@davidpotter946211 ай бұрын
I had a 250 watts heat lamp plugged in most of the day, and it has kept the temperature 🌡️ at 24°C in here. It was -5°C last night, so I made a 🔥🤗. I had 715 watts coming in for awhile but the batteries filled up. There's too much power in the early afternoon, and the darn wind generator starts making power, of course, right when I don't need it. So I hooked up the hotplate for awhile for extra heat. I was going to cook on it, but the water 💦 jug was empty so I couldn't stir anything up or make coffee 😔☕... So the batteries 🔋 are full and I guess I will have to make some brownies to use some of this 🌞 juice. This lamp is making my solar flashlight 🔦 charge. I'll order a controller next week. I have to rewire twenty batteries from 24 to 12 volts. Ugh. I don't even want to, lol. I'll just do part of them at a time, eh? Then I can let the wind generator so it's thing more properly. I've decided it must be 12 volts. It likes to make about 18 volts a lot. So it will work better at least. It doesn't get over 24 volts enough to do much. You might get lucky with the generator and it was just the plug. I haven't been to the store in weeks, five I think, anyway I'm out of ice cream 🍨 for a few weeks, so when you were showing it there, my stomach was growling for some, lol. So now that you did that, I'm going to the store for ice cream. And a couple of pizzas. While the sun is out, I'm going to carry in some wood 🪓. I'm going to need the ice cream to start in on these battery connections. I was going to wait on the new controller, but the wind generator can charge them for a week. It's okay to have a spare controller. Tomorrow is going to be a little warmer, so the plan is to get the big window put in the greenhouse. I had to fix a little boo boo I made earlier or I would have had it in already. After I got the free lumber, I decided to make it bigger. I bet you were glad the generator kept going, lol. That old plug was too long, might not have been the right one. That's why small engine plugs are short usually. If it does it again, use a shorter plug.
@gypsyjenna11 ай бұрын
Well better to have too much power than not enough I suppose! Hope you got your ice cream fix!
@davidpotter946211 ай бұрын
@@gypsyjenna , all this gave me an idea 💡🤣, since I have the heat lamp in the lamp, I can use it and get the window hung tonight in the greenhouse 😁👍😎🤔 🔥🌡️🔦🌞🔋💡I'm going to retire eight of the oldest batteries to the hot water pump system that I'm going to put in the greenhouse to have hot water 💦. So I only have twelve on the other inverter. But I think it will work out. Then I'll get two more 24 volts 100 amp hours lithium iron phosphate batteries ⚡😎👍 so that will be 400 amp hours. Since the inverter maxes out around eighty amps, each battery 🔋🔋🔋🔋 would only have to give twenty amps at the most. So that way there's enough for a few days of no sun. Then there would be the 12 volts side, with 12 batteries, I guess it would last a week. Yeah, I guess that'll be enough. That way I never have to use the ⛽ generator when it's cold. Or ever. Isn't that better?
@JohnSmith-b4b11 ай бұрын
I'm an old un from the UK n I just so look forward to your videos each week! You put a lot of people (was gonna say men...oops I've done it now 😅) to shame with how you tirelessly try and problem solve and taking time to be humorous too...true grit!
@occamsrazor793910 ай бұрын
Very interesting video. I understand cats. They want to be fed first. And when I eat, they want to check out what I am eating.
@patriciaevans112911 ай бұрын
Hang in there I can relate on things happening back to back And it sucks!!😊 Keep your. Chin Up!!
@dazzatwoa11 ай бұрын
Generator and firewood sorted. Good job👍
@David-jd5lp11 ай бұрын
Put some Sea Foam in your tank. It will get rid of the ethanol and gummy build up.
@levent820811 ай бұрын
Yes, yes, yes, Sea foam is really good and easy to find. You should use it too, once a year for instance to prevent problem, good too for car injectors.
@plaintruth463711 ай бұрын
Check the CCA of your batteries with a load tester. A bad battery can still show 12v but lacks the amps for proper use.
@keithl624911 ай бұрын
Glad the sparkplug fixed the generator. It might be a good idea to install a couple of switches to cut the power from your battery bank and also your solar panels. That way if you want to swap batteries out, you cut the power from the panels and then the battery bank. Just my nosey two cents😁 Ramsey says it is your job to fix things, his is to lounge around.
@gypsyjenna11 ай бұрын
Haha that's the way it goes too!
@johnsemrau641210 ай бұрын
Hey girl you need a back up Genny and 2 harbor freight solar kits the non amorphous type with the USB ports n 2 light bulbs in each kit 💪👍😁😊
@johnsemrau641210 ай бұрын
And make the Backup Propane 😁👏🙏
@texaspreparedness169011 ай бұрын
It looks like you have a similar situation as I have with the trees around. I built a portable solar panel rack on wheels. It helped a lot being able to move them around.
@dangeroustoman11 ай бұрын
Always unplug your panels before disconnecting your batteries.
@K_Dawg197911 ай бұрын
While you have your generator out. You should clean the spark arrestor if that generator has one.
@philmissy111 ай бұрын
Whenever you have multiple batteries in parallel and you take a voltage reading you get an average of all 3 so potentially you have one battery which is not like the others and bringing the team down. I've seen you check them individually before and maybe just swap out the weakest one and you might see an improvement.
@joanneowen454011 ай бұрын
Hi! New subscriber here..found you while watching KZbin,and I'm loving your videos..the scenery and the hard work you do to stay and live in your trailer is inspiring..love your cats and your down to earth style.Look forward to watching your older videos and what is coming next.Best of health and luck this winter!
@gypsyjenna11 ай бұрын
Thank you 😊
@johnkenny221011 ай бұрын
Jenna another top show thanks for sharing hope you get it all sorted Johno Darwin NT 👍🍺
@janebray939211 ай бұрын
Hi Jenna🙋♀️🛻🇨🇦❤️‼️ watching from Quartzite AZ, While you are Jenna and her genny, I am Jane and her genny and its dead in the water..lol I mean desert. 😂 an older Yamaha 2000 that has a switch to turn on, thats broke somehow during transport down here😢😮, so it purrs like a kitten but you cant plug anything into it, temperatures are 12°C but Im a winter wimp, so while I wait for the part, Im using candles/clay pots, helpes a bit. During day, the 95watt panel gets the one agm battery 100% by 10am but as soon as that sun goes down the battery does too. To 51%😮 by daylight. I think the charge controller is the biggest power drain, I dont even run lights, or water pump at night, nothing! 😮
@gypsyjenna11 ай бұрын
Oh no, hope you get your part soon and at least you're staying warm! 🙂
@jacquethirlkel300111 ай бұрын
Thanks for your videos! God bless!
@Darryl60310 ай бұрын
To avoid shorting your circuit, always make all connections first, before applying power!
@MichaelSchmitz-mk8ll10 ай бұрын
I got a Victron Energy 150/70 MPPT Solar panels controller, an I can say is "WOW" 900watt panels runs a lot in my square box camper
@ShrimpOutdoors11 ай бұрын
Don’t use Supreme either. It too has ethanol which ruins small engines. Only use non-ethanol 100% gas.
@craigtarbox349911 ай бұрын
Glad you got the generator going with just a spark plug . It usually is something simple , but it will drive you crazy figuring out what it is . As for the charge controller , that's kind of scary. I just ordered my first solar set up and i'm afraid that I will screw it up. Well it is good to see you are back in business .🙂
@amandaspriet307611 ай бұрын
Girl I don't know how you do it! We just moved into a rental for 3 months, we where in a 23 foot trailering 2 cats and a dog for 6 months in NS. It was the hardest during the month of Nov. Everything damp all the time and cold. Good on you but I honestly couldn't do it full time.
@gypsyjenna11 ай бұрын
For sure! The wood stove makes all the difference, honestly! I don't know what I would do without it lol
@JJKHaywood11 ай бұрын
Seems I Remember reading that the Solar panel should only be connected or disconnected to MPPT controller with batteries connected. Noting damage will occur if panels are “live” and are hooked to MPPT without batteries connected. But then the Corner Kids might of sold me some bad kool aid.
@-RyN-2310 ай бұрын
You can keep using power while they charge, yes they charge slower because your using some of the power but still thats what most people do or they only run what power they need while charging but no need to unplug the camper when the charger is on
@greagior9 ай бұрын
I built a 180w array to a 300Ah AGM bank. I'm switching to all jackery and it's working better.
@Kyrad77711 ай бұрын
Just curious why you didn’t connect your roof solar panel to the EcoFlow solar input while your charge controller was down. Then you could plug your battery charger into that and charge the batteries temporarily. Even if it’s a reduced rate, not sure what the limits of the inverter are on that unit. In all fairness, I don’t know your whole setup, but that in theory could be a backup plan.
@charlessarratt294811 ай бұрын
Make sure your new charge controller is set for agm batteries. The charging is different for different batteries
@gypsyjenna11 ай бұрын
I set them for my gel batteries. Thanks!
@williamsuttle364511 ай бұрын
Have you ever thought about buying one of those small generators as a backup? They are less than $200, and amazon sells them. It would be just to charge your batteries. Sorry if I'm over stepping.
@BruceGordon92511 ай бұрын
Living off the grid, Not for the faint of heart.
@davidrenwick671811 ай бұрын
Yaa it runs 👍I knew you could do it with a little help from a friend.
@oldminer538711 ай бұрын
Great to see that you have worked through solving the generator-electrical problems. There is a saying that if can't be fixed with a hammer it must be electrical. Take care.
@gypsyjenna11 ай бұрын
Haha, I was almost ready to take a hammer to a fee things lol
@MrSTOUT7311 ай бұрын
Disconnect from the battery BEFORE playing around with the other end! lol And you don't need premium fuel in your generator. Read the manual.
@gypsyjenna11 ай бұрын
🤣living on the edge over here
@phillyfathead11 ай бұрын
Don’t waste ur money on premium fuel for the generator!
@rookm1311 ай бұрын
@@phillyfathead while i also agree with you on the premium thing, that might be the only grade in their area that is marked "non-ethanol". That would be my only argument for using premium on the generator when storing the fuel for a long time.
@MrSTOUT7311 ай бұрын
Everybody rails on ethanol gas, blaming it for everything from hemorrhoids to post nasal drip. I've used it for over 30 years in all my small engines and never had an issue. She uses it fast enough that long term storage is hardly a problem. Properly treated (Stabil, Sea Foam) regular will last 2 years.
@rookm1311 ай бұрын
@@MrSTOUT73 "I dont know why the fuel gets blamed for everything" _Meanwhile does everything in their power to counteract the things it gets blamed for_
@michaelbrinks808911 ай бұрын
I've had the white porcelain crack off but never neen a sparkplug pull apart like that....🤪.......Glad generator is at least fixed.
@supremeautomotive674911 ай бұрын
YOU HAVE TO DISCONNECT THE SOLAR PANELS BEFORE EVER TAKING BATTERYS OUT OUT OF SYSTEM. SOLAR ALWAYS FIRST THEN BATTERIES OR THIS WILL HAPPEN
@dschephigh111 ай бұрын
I think if you add a little more oil to your generator the low oil shutdown will be more satisfied and not shutdown. Just try it, it may work.