Using MC MoveJog
6:42
Жыл бұрын
Siemens Technology Object Setup
18:53
ChannelIntroDec2022
0:19
2 жыл бұрын
SIZER Part 2- Siemens Motor Data
13:57
Siemens SIZER Tool Basic Training
27:36
Пікірлер
@yiyunboy
@yiyunboy 10 сағат бұрын
any video to explain how to use DCM as dc motor field supply?
@jasonwattsae
@jasonwattsae 9 сағат бұрын
I don't have a specific video about it, but it is fairly straightforward. Check out the Siemens document below: drive.google.com/file/d/148NmR-qTWPL3zOzGUE5ErrGka0UhO2Jp/view?usp=drive_link
@vivekdubey4089
@vivekdubey4089 Күн бұрын
Suggest some references to this kinda deep knowledge on co-relating physics+ electrical things with a great explanations
@jasonwattsae
@jasonwattsae 14 сағат бұрын
That's kinda why I do this channel. Outside of in-person training, there isn't much. Even in school it isn't very practical. My dad wrote a book on some of these topics, available below, with more to come. a.co/d/6oyjkHq
@ariprismaa
@ariprismaa 4 күн бұрын
Sorry sir, how are setting reverse in servo s120 ? Please answer... Thanks you
@jasonwattsae
@jasonwattsae 4 күн бұрын
In the control word, bit11 (drive) is "setpoint inversion" put that bit high and it will run in reverse. You can also just send a - speed setpoint (-25% for example) and it will run in reverse.
@iran_siemens
@iran_siemens 8 күн бұрын
👌
@jasonwattsae
@jasonwattsae 8 күн бұрын
💯
@Politifood
@Politifood 8 күн бұрын
Hey Jason, you are a great guy for sharing these things for free. Anyway, I have a problem with the live chatters. Believe me, chatting with people online downgrades badly the quality of the podcast. There might be valuable people there with great questions but most of them are quiet and those noisy are just texturbators. They just need to make some noise(most of them) breaking your narative. I would pay for watching your videos without commentators allowed. Talk to them only on discord or let them your email for Q and A or whatever but don't let them turn a high value automation live stream into a teenage talking being at his first beer in life. Cheers!
@jasonwattsae
@jasonwattsae 8 күн бұрын
I appreciate your feedback! I agree that I do get distracted sometimes and there are some that I give more of my attention than I should. The two main things out I want to build on this channel are Technical Knowledge and Community. I have been blessed beyond measure by being shown things that "connected" with my nature at an early age. I had someone (my dad) that was more than just "professionally" interested in automation invest in me and it changed my life. During my career I formed a community of people in this field that are genuine friends. One thing that turns a lot of young people away is they have an image of our field that they will be locked up by themselves with everyone else having fun at their jobs. I want to have a place where the true nature of our field can live. I will try and be a little more selective so that the content can be better. I also plan on editing the livestream content like I have in the past that will take out a lot of the distraction.
@Constrain123
@Constrain123 17 күн бұрын
Hi, thanks for the video. It could have been much better if you have a specific discussion on the topic "vfd flying restart function with all the related parameters ( p1200 , p1201, p1202 , p1203 , p1204 / p1205) .
@Constrain123
@Constrain123 17 күн бұрын
Could you share your email ID, I need to get in touch with you regarding the above-mentioned topic
@jasonwattsae
@jasonwattsae 16 күн бұрын
Discord is the best way to get in touch with me. Find the link in the description on my channel.
@jasonwattsae
@jasonwattsae 16 күн бұрын
I may very well do one specific for Flying Restart and why it is necessary. In it I would go through the parameters.
@Yazzol
@Yazzol 18 күн бұрын
Hi. Sorry, maybe it is because I am not from an english speaking country,but i really didn't understand what could be an application for the synchronous axis. When are they used in industrial environments?
@jasonwattsae
@jasonwattsae 17 күн бұрын
Great question! A synchronous axis is the equivalent of putting a sprocket on the shaft and having a chain connect the two axes. This is common in many industries, but the easiest example would be on a paper line. If two rolls have different diameters they will need to turn at different shaft speeds to make their surface speed the same (this means the same sheet speed). Synchronous axis makes it to where you can match the speeds exactly, or even make a new ratio on the fly. I have other livestreams that go through this more in detail. Check out my "How to design a winder" stream for example. (Also, even people from thr US don't understand what I am saying a lot so don't feel bad 😅)
@Yazzol
@Yazzol 17 күн бұрын
@jasonwattsae Thank you
@jasonwattsae
@jasonwattsae 17 күн бұрын
@Yazzol Always!
@nilaybhambere9298
@nilaybhambere9298 20 күн бұрын
I have just replaced 600 amps 6ra70 drive with 600 amp 6ra80 drive for constant torque 190 K.W , 3000rpm d.c motor. With 6ra70 drive it was working fine but after replacing with 6ra80 drive I am facing problem at very low speed. The motor is unable to achieve set point speed due to increased armature current. The field excitation current is measured at rated current. Now how to increase armature voltage so that armature current can be reduced & desired torque can be achieved?
@jasonwattsae
@jasonwattsae 20 күн бұрын
That is an interesting issue. If you take your RA70 parameters you can add 50000 to them to convert them to the RA80 (for the most part). It sounds like there is either an issue with the motor model (incomplete data) or that your feedback may not be set up correctly. Are you using an analog tachometer by chance?
@larhratyAmine
@larhratyAmine 29 күн бұрын
Best luck from Automation specialist in Morocco ❤
@jasonwattsae
@jasonwattsae 29 күн бұрын
It's a worldwide community! Thank you for your support!
@Diplopada
@Diplopada Ай бұрын
So much great information! I am 4 months into my automation engineering studies and have just finished my first major project. (Making a bowtie shape on an XYZ CNC.) This video gave me some great insights on designing reusable blocks. The multi instance timer is golden for my project! :) Keep up the good work. Your channel is a hidden gem. More people should know about your in-depth live/on-demand feed.
@jasonwattsae
@jasonwattsae Ай бұрын
I'm glad it is helpful! I need to do a better job of editing so that the channel performs better, but I love the community we are building! I'm glad you found it!
@user_00759
@user_00759 Ай бұрын
Amazing Jason. Nice explanation. Thank you so much.
@jasonwattsae
@jasonwattsae Ай бұрын
I appreciate the kind words! I'm glad it was helpful!
@isaiasmachado6219
@isaiasmachado6219 Ай бұрын
Thank you very much for the videos. Can you do a video teaching how to control a S210 servodrive by torque using a S7-1200?
@jasonwattsae
@jasonwattsae Ай бұрын
I think I will have some demo hardware in January that has S210s. I will try and do a video on them then. In the meantime check out the livestream below as I go through most of it, you would just have to set up the telegrams on the s210. kzbin.infospLxohsd4T8?si=C88hHB6RR-FInuoC
@isaiasmachado6219
@isaiasmachado6219 Ай бұрын
@@jasonwattsae Thank you so much for replying. God bless you.
@jasonwattsae
@jasonwattsae 29 күн бұрын
Always! I love helping others out.
@ghosthunter9897
@ghosthunter9897 Ай бұрын
I am currently commissioning a Sinamics S120. I'm glad I found your videos-many thanks! Keep up the great work!
@jasonwattsae
@jasonwattsae Ай бұрын
I'm glad they are helpful! There is a lot to go through. If you have a specific question feel free to ask and I will try to point you to the right one. If there isn't one I will try and talk about it on the next stream!
@abdulnasir651
@abdulnasir651 Ай бұрын
What is that time written at the right corner of the function diagram. Like 2000 microseconds, 4000 microseconds, etc.please let me know
@jasonwattsae
@jasonwattsae Ай бұрын
So I have had to take the time to go through and see exactly what you were referring to (and that is hard on my phone) thank you for your patience. The numbers in the top right corner of the function diagrams in STARTER is how fast that particular function is being executed. For this particular device we are using the standard CUD and it is a little slower than the ACUD. For example, the speed controller is running on 2ms (2000us) cycle time on this unit. I am not exactly sure how fast the ACUD is, but for comparison to the S120 CU320-2 has a base servo cycle time (speed controller, current controller) of 125us.... so 16 times faster than this unit and that is on DEFAULT settings. You can speed up the CU320-2 (by reducing the number of available axes) and get the base cycle time down to 32us... over 62 times faster than this CUD....
@vorapobautomation9760
@vorapobautomation9760 Ай бұрын
Is it same with S120 Drive?
@jasonwattsae
@jasonwattsae Ай бұрын
There are different functions available, but the S120 can be set up in a very similar way. BICO is available on all SINAMICS drives.
@vorapobautomation9760
@vorapobautomation9760 Ай бұрын
@@jasonwattsae Can you do in S120 in the next video ?
@jasonwattsae
@jasonwattsae Ай бұрын
What are you wanting me to cover? I actually did this in my live stream on load-sharing on the S120. It is a little easier on the S120 because you can access multiple drives directly without having to use the IO.
@vorapobautomation9760
@vorapobautomation9760 Ай бұрын
@@jasonwattsae Sorry I will go back to see it again.
@jasonwattsae
@jasonwattsae Ай бұрын
It's OK. There are a few differences in what I did here and in the load sharing stream, so if there is something specific I might could touch on it.
@chakrittanpo461
@chakrittanpo461 Ай бұрын
i have problem with this CIP function, i can Read/Write to Allen bradley PLC , but after that data not update so i use WtahDog function also to re-connection, but after that will see probelm again.
@jasonwattsae
@jasonwattsae Ай бұрын
It sounds like you may be calling the block the wrong way. Don't toggle the EN on and off. Just set the rate to what it needs to be and leave everything on. Sometimes the internal blocks get messed up. You can look at the instance and see if there are errors on the TCON and TSEND TREC blocks that are built in. it is a bit of a pain to reset them. I did a livestream on this block more recently that goes into a little more detail.
@KadirTURAN-q9i
@KadirTURAN-q9i Ай бұрын
how can i read actual current ?
@jasonwattsae
@jasonwattsae Ай бұрын
It is r68, but it is scaled based off of p2002. I talked about the scaling it in depth in my livestream today on BICO.
@davidesartore3884
@davidesartore3884 Ай бұрын
Awesome videos! I really want to see more videos like these old ones
@jasonwattsae
@jasonwattsae Ай бұрын
Thanks! Is it the content or the way it is presented? This one was recorded in one go, but it was not "live". I do plan on doing more edited content but it is not fitting into my schedule these days.
@user_00759
@user_00759 Ай бұрын
Jason I need to know what are BICO,CI,CO etc terms with clear explanation. Can u help me?
@jasonwattsae
@jasonwattsae Ай бұрын
Absolutely. All of those represent the way a Siemens drive can be custom configured to operate in almost any application. They are the way that you can connect values from inside the drive to other places inside the drive. Check out this video from around the 27min mark for an explanation. kzbin.infospLxohsd4T8?si=r-fbM2rOUWA7TYwy
@jasonwattsae
@jasonwattsae Ай бұрын
Also, I will go over this in my next stream.
@user_00759
@user_00759 Ай бұрын
@@jasonwattsae thanks a lot
@jasonwattsae
@jasonwattsae Ай бұрын
@@user_00759 I talk about it a lot in other streams as well, but I don't have a stream or video just on it. Thanks for bringing it up!
@fernandosanchez6576
@fernandosanchez6576 Ай бұрын
great video more please 😊
@jasonwattsae
@jasonwattsae Ай бұрын
There is a whole lot more on the channel! Glad this one was helpful!
@zero2infinity16
@zero2infinity16 Ай бұрын
Best detail course. And next target for 2025
@jasonwattsae
@jasonwattsae Ай бұрын
Thanks! Some cool stuff is coming for sure!
@ignatiusquayson6722
@ignatiusquayson6722 Ай бұрын
❤❤❤
@jasonwattsae
@jasonwattsae Ай бұрын
Thanks for the support! Hope you benefitted from it!
@iran_siemens
@iran_siemens Ай бұрын
❤❤❤
@jasonwattsae
@jasonwattsae Ай бұрын
Great seeing you on!
@ignatiusquayson6722
@ignatiusquayson6722 Ай бұрын
Hello everyone, Jason I’ll like to know about the new s7-1200 G2 motion control capabilities and Tia portal v20
@jasonwattsae
@jasonwattsae Ай бұрын
I'll bring up some of the documentation in the morning and we can start from there!
@vorapobautomation9760
@vorapobautomation9760 Ай бұрын
How to change on the fly of speed of mortor in MC_MoveVelocity ?
@jasonwattsae
@jasonwattsae Ай бұрын
for MC velocity you either need to activate a new command with the new velocity, or modify the Velocity.Override to modify the velocity during the move. If you want to be able to change the velocity setpoint and immediately change to the new velocity, use the MC_Jog command.
@zero2infinity16
@zero2infinity16 Ай бұрын
Exciting waiting
@jasonwattsae
@jasonwattsae Ай бұрын
We have a system in our shop that is about to be powered on. I am going to be doing a few streams about the setup so be sure to have notifications on!
@vorapobautomation9760
@vorapobautomation9760 2 ай бұрын
Why CU320 have fault code 30040 after release emergency stop and reset ?
@jasonwattsae
@jasonwattsae Ай бұрын
Thanks for your question! This is an interesting fault, one that I didn't not know from memory. I looked it up and it reads "Power Unit: Undervolt 24V" While this fault may be coming into the CU, this fault is active only for "x_INF" object types. Meaning the problem is from your infeed module. If I had to guess, there is a relay, or contact that is dropping out the EN signal (which is 24V). It might be that that connection was also jumpered to the 24V+ input, which should always be on. Either way, you are losing the 24V+ supply power to your infeed. Check the wiring, then check that the 24V supply is not dropping out because of some other issue.
@lascauraul293
@lascauraul293 2 ай бұрын
Hi, how does the distance parameter get into the drive if I use this function but I have chosen telegram 105 ? I didn't find any position setpoint in telegram 105 words or PZDs.
@jasonwattsae
@jasonwattsae 2 ай бұрын
Great question! The drive is only a speed controller when using TOs. That means the PLC is doing the position control loop and sending a speed setpoint to the drive. For this reason you want your ramp times in your drive as close to 0 as possible because the PLC generates a signal with a ramp built in! Doing it this way, the code using TOs can be used on any drive, even one with no communication! You only need a speed setpoint and a speed feedback!
@lascauraul293
@lascauraul293 2 ай бұрын
@@jasonwattsae Thanks!
@jasonwattsae
@jasonwattsae 2 ай бұрын
You're welcome!
@DaDaDan_1
@DaDaDan_1 2 ай бұрын
Thank you so much for this! exactly what I needed.
@jasonwattsae
@jasonwattsae 2 ай бұрын
I'm glad it was helpful! I have some more cool stuff in the works!
@zero2infinity16
@zero2infinity16 2 ай бұрын
Exciting waiting
@jasonwattsae
@jasonwattsae 2 ай бұрын
Check out the DCM livestream! I went over quite a bit, but plan on more in the future!
@notyouraverageredneck8167
@notyouraverageredneck8167 2 ай бұрын
Thank you for taking the time to make this training video. It's very informative and I appreciate it dude!
@jasonwattsae
@jasonwattsae 2 ай бұрын
I'm glad it was helpful. There will be more new content soon!
@javierenriquepozzohuerta8075
@javierenriquepozzohuerta8075 2 ай бұрын
can you have more than one FB CIPClient? I created one FB CIPClient for each data type.
@jasonwattsae
@jasonwattsae 2 ай бұрын
I would think you can but because it uses a separate TCON block each you may run low on connection resources in your PLC if you are using other things like HMIs or PUT and GET functions.
@VignandoGuillaume
@VignandoGuillaume 2 ай бұрын
Hello Jason! I'm trying to use the LCCF Cip Client to communicate with a controlLogix and i'm in the trouble because i need to write in UDT'S Tags inside the Rockwell and also write and read String Tag type. Can you help me?
@jasonwattsae
@jasonwattsae 2 ай бұрын
Strings are difficult because each letter is 32bits in Rockwell. Let's continue the chat in the Discord as there should be a way to get around it.
@youcefdjediai6934
@youcefdjediai6934 2 ай бұрын
Many thanks, from Algeria
@jasonwattsae
@jasonwattsae 2 ай бұрын
You are very welcome! More to come soon!
@சதீஷ்குமார்-ப7ச
@சதீஷ்குமார்-ப7ச 3 ай бұрын
Hello sir , what is r0000 parameter? And its showing E whats does it really mean? Thanks in advance :)
@jasonwattsae
@jasonwattsae 3 ай бұрын
The first parameter that I am aware of is r0002, I am looking at the list manual right now, and there is a r50000 that is the status specifically for the DCM, but it does not have a display option for "E". It could be that you have selected a drive object that does not exist and it just doesn't know what to do with it. Are you using the BOP20?
@சதீஷ்குமார்-ப7ச
@சதீஷ்குமார்-ப7ச 2 ай бұрын
​@@jasonwattsae yes sir it's BOP20 ...so what we observed was when we powered on it showing drive 2 parameters with r00000 as 10.3 but when we shift drive 2 parameters to drive one it's showing r00000 as E...when immediate powered on its showing drive 2 parameters but rdy is blinking for drive 1 when we pressed fn + up key... So why drive one showing E in parameter r00000 but showing value in drive 2 when it is configured for drive one? Can you please explain sir?
@jasonwattsae
@jasonwattsae 2 ай бұрын
@@சதீஷ்குமார்-ப7ச It sounds like there is a mismatch in the parameter sets. Are you sure that both dives are the same firmware?
@சதீஷ்குமார்-ப7ச
@சதீஷ்குமார்-ப7ச 2 ай бұрын
​@@jasonwattsaesir for this drive there is only one control card and one power unit there is no second drive
@jasonwattsae
@jasonwattsae 2 ай бұрын
@@சதீஷ்குமார்-ப7ச I see. If you are able to Join the Discord, I believe I would be able to provide better help. I am having trouble understanding why the parameter is changing.
@CWP-m6c
@CWP-m6c 3 ай бұрын
🤟👁️☝️💯
@jasonwattsae
@jasonwattsae 3 ай бұрын
Thanks!
@josefranciscoarandaguevara8237
@josefranciscoarandaguevara8237 3 ай бұрын
Can i use this instruction with 300 ethernet safety plc?
@jasonwattsae
@jasonwattsae 3 ай бұрын
I would have to check. The blocks I use in this video are for the 1x00 processors because it uses a HW_ID, but there has been a new version of this block released since I made this. It may have a version that uses the 300 version of HW addressing.
@ban-m8o
@ban-m8o 3 ай бұрын
Thank you very much for great tutorial! Means a lot! Greetings from Serbia
@jasonwattsae
@jasonwattsae 3 ай бұрын
So glad it was helpful!
@js-wtf
@js-wtf 3 ай бұрын
Great video, greeting from VietNam
@jasonwattsae
@jasonwattsae 3 ай бұрын
Thank you! I'm glad it was helpful!
@zhanbulattulegenov4283
@zhanbulattulegenov4283 3 ай бұрын
Hi Jason, I would like to ask some questions. How can I contact you?
@jasonwattsae
@jasonwattsae 3 ай бұрын
The best way is to join the Discord and drop your questions there. You can also send a DM there.
@vorapobautomation9760
@vorapobautomation9760 3 ай бұрын
How to use S120 with on the fly paper cutter for motor cutter with on the fly line ?
@jasonwattsae
@jasonwattsae 3 ай бұрын
Check out my explanation of a rotary knife in the video below and let me know if this helps! kzbin.infowkcElnMgVXg?t=432&si=oi8DuEPwpRtDOT2z
@vorapobautomation9760
@vorapobautomation9760 3 ай бұрын
How to use Simotion D425 control V90 ?
@jasonwattsae
@jasonwattsae 3 ай бұрын
It is very similar to the way I set up the TO. Once you bring in the gsd file into the hardware config in SCOUT you can link an Axis to it. I don't think I have a copy of SCOUT anymore or I would show it since it is almost the same as a TO.
@vorapobautomation9760
@vorapobautomation9760 3 ай бұрын
@@jasonwattsae I use TIA Scout and I don't know the telegram , command and function block to control speed or position of V90 by D425 CPU. Can you explain more detail or make the new video please ?
@jasonwattsae
@jasonwattsae 3 ай бұрын
I will try and find a copy of SCOUT so I can show the process. You would need to use a telegram 102, set up the v90 gsd like i did here, then create an Axis that is pointing to that telegram. After that, you would need to proceed like ant other axis in SCOUT
@thomassaook7787
@thomassaook7787 3 ай бұрын
Thanks for this valuable broadcast, i have some questions regarding motion control about the "Rotary Cut" two axis combination system!
@jasonwattsae
@jasonwattsae 3 ай бұрын
Are you in the Discord? That is the best way to chat about stuff. I'll make a thread and we can discuss. I am sure there are others that have questions too.
@thomassaook7787
@thomassaook7787 3 ай бұрын
@@jasonwattsae Yes i am in as "Thomas Saook"
@jasonwattsae
@jasonwattsae 3 ай бұрын
send a message in the #automation channel and we can chat about it.
@ahmedhelmy593
@ahmedhelmy593 3 ай бұрын
❤ Ahmed Helmy,thanks Jason
@jasonwattsae
@jasonwattsae 3 ай бұрын
You are so welcome! I plan on doing some sort of stream today!
@kaiqueTIAPORTAL
@kaiqueTIAPORTAL 3 ай бұрын
Hey man, nice content, thanks a lot for sharing your knowledge. Is there any repository with full projects for us to study, and learn how to structure a project. thanks
@jasonwattsae
@jasonwattsae 3 ай бұрын
I do have some content that is avaliable for members, but there aren't really full projects. There are some really good application examples on the Siemens Support Website that help a lot. I'll try and link some on my next livestream
@RohitChavanTM
@RohitChavanTM 4 ай бұрын
Good work 😊
@jasonwattsae
@jasonwattsae 4 ай бұрын
Thank you!
@RohitChavanTM
@RohitChavanTM 4 ай бұрын
​@@jasonwattsae On another video of yours I had commented for cu320 & dcm oa link. Now, I am doing cross cutter application where Rotary access is DCM and Camming & technology runs on cu320 dcc. Will you help me understand what is Flying Homing, also I have question direct reference generated from cu320 bypasses RGF of DCM. Will it affect on motor ?
@jasonwattsae
@jasonwattsae 4 ай бұрын
Flying homing essentially takes the current position and makes it the home position. It is used in cutting applications to reset the home position at the position of the cut edge so that your position is now the length of the sheet (assuming no slipping). As for bypassing the RFG, you will want to have some sort of controlled acceleration. Which if you are using GMC Gearing on the CU320-2, it is taken care of by you acceleration parameters in the CU320-2.
@RohitChavanTM
@RohitChavanTM 3 ай бұрын
​@@jasonwattsae Firstly I want to thank you for your kind reply. I will be trying flying home so I'll update on that. Other than that I'll be testing DCC chart and overall application. So far I didn't saw that Gmc gear in block. Let me test it once on my end, I'll share my results and video if possible. Thank you again. 😊
@jasonwattsae
@jasonwattsae 3 ай бұрын
You are welcome!
@jeremia82
@jeremia82 4 ай бұрын
Amazing content keep up the good work :)
@jasonwattsae
@jasonwattsae 4 ай бұрын
I am glad it is helpful! More is coming I promise!
@RohitChavanTM
@RohitChavanTM 4 ай бұрын
Have you worked on CU-320 with DCM over OA-Link ?
@jasonwattsae
@jasonwattsae 4 ай бұрын
Yes! I actually have! I used a CU320-2 to run electronic gearing and send out setpoints to 4 DCM. OA link is one of the coolest features not many know about!
@rahulchhajiyan9401
@rahulchhajiyan9401 4 ай бұрын
sir please make a video on wrrec write data record ,can you give a solution of an error DF80-b200
@jasonwattsae
@jasonwattsae 4 ай бұрын
I will research and make a short about the error. I will reply here, but make sure you are subscribed so you don't miss it!