SINAMICS S120 Setup in TIA Portal (STARTDRIVE)

  Рет қаралды 4,494

Jason Watts AE

Jason Watts AE

Күн бұрын

I step through the very basics of setting up a multi axis SINAMICS S120 system in TIA Portal. This gets you started with Siemens servo drive programming.
#siemens #tiaportal #startdrive #s120 #automation
0:00 Introduction
1:35 Inserting CU
4:20 Line Module Setup
6:26 Motor Modules
9:49 Drive Cliq Motor
11:27 Induction Motor
14:20 SMC Module (Encoder)
17:20 PLC Addition
18:17 Component Naming
19:11 Closing Remarks

Пікірлер: 21
@691bilal1
@691bilal1 7 ай бұрын
Great videos on different and some unique level, I have started watching in detail all your videos, really hungry for Sinamics S120, thank you so much.
@jasonwattsae
@jasonwattsae 7 ай бұрын
My old videos have some great information, at that point I worked almost daily on S120 applications when I was an Application Engineer. Now I feel like I do more with PLCs but miss the cool stuff people were doing with the S120.
@gajarubanjeyakumar7226
@gajarubanjeyakumar7226 Жыл бұрын
Thank you!
@kondito88
@kondito88 7 ай бұрын
thx :)
@jasonwattsae
@jasonwattsae 7 ай бұрын
You're welcome!
@ferreoldeboisseson4842
@ferreoldeboisseson4842 5 ай бұрын
Hi, thank you very much for your videos!! But I have a problem when I want to add a drive: when I add a device I am only offered controllers, HMI and PC systems but not drives. Is this a package that needs to be added? Or maybe my version doesn't allow it (I'm using v16)?
@jasonwattsae
@jasonwattsae 5 ай бұрын
Yes! You need to download and install a free package called "Startdrive Basic". Below is the link to V16: support.industry.siemens.com/cs/document/109771710
@gajarubanjeyakumar7226
@gajarubanjeyakumar7226 Жыл бұрын
Could you please explain the difference between SLM and ALM modules?
@jasonwattsae
@jasonwattsae Жыл бұрын
Yes, I believe that there is a lot of information in my product overview video, but here is a short explanation: SLM: Smart Line Module. This is a "Line Commutated" IGBT bridge rectifier that allows for current to flow back onto the grid. Harmonics are similar to a 6 pulse drive so a line reactor is required to protect the grid. This would be a standard regen drive ALM: Active Line Module. This is a "Self Commutated" IGBT bridge rectifier that is capable of gating the IGBTs so that not only can it correct for power factor, but it can also boost the DC link voltage during low line supply voltages so that motor torque is not affected. In the US, the minimum DC link voltage on an ALM is system is around 720V. You must use a tuned harmonic filter called the AIM (Active Interface Module) that eliminates almost all of the harmonics cause by IGBT switching. The ALM has the ability to be used as a grid former to create an island grid. In almost all cases, a SLM system is less expensive than an ALM, but the ALM makes the system very immune to line power fluctuations and allows for much better torque regulation at the motors. I hope this helps! I'll put this down as a topic to discuss because the ALM is a really cool piece of technology by itself.
@prakashelectricals5581
@prakashelectricals5581 Жыл бұрын
Hi sir If possible, Please upload training video for S71200 CPU, V90PN SERVO, positioning mode in drive and to_object in TIA portal project, standard Telegram 111 in v90 parameters,
@jasonwattsae
@jasonwattsae Жыл бұрын
Telegram 111 is a great telegram to use if you are not using technology objects, but most of the functionality of EPOS is easier to use the the "Position Axis" TO. There is an EPOS TO in later versions of TIA Portal, but all it does is make the configuration of the SINA_POS FB easier. The easiest way to control a V90 with an S71200 (I have done this on a few of my projects) if you are using EPOS is to use the SINAPOS block found at the link below: support.industry.siemens.com/cs/ww/en/view/109475044
@prabhakarans4623
@prabhakarans4623 4 ай бұрын
How to communicate Siemens driver g120 using c#(csharp)?
@jasonwattsae
@jasonwattsae 4 ай бұрын
That would be interesting to say the least. I have never thought about how to send ProfiNet messages from .Net because there are some issues with bus priority... maybe you could control it using direct parameter access.... great thought! I will do some research and get back with you.
@prabhakarans4623
@prabhakarans4623 4 ай бұрын
@@jasonwattsae ok sir thanks for your response
@prabhakarans4623
@prabhakarans4623 4 ай бұрын
If possible give some examples or documents for c# communication
@jasonwattsae
@jasonwattsae 4 ай бұрын
I will. I found a couple manuals that I will link after reading them further.
@prabhakarans4623
@prabhakarans4623 4 ай бұрын
@@jasonwattsae ok sir thanks
@yormanjorcetquispechavez3330
@yormanjorcetquispechavez3330 Жыл бұрын
EXCELENT PLEASE ONE COUSE :)
@jasonwattsae
@jasonwattsae Жыл бұрын
I have finally been able to finish getting the other videos loaded! I hope to be able to to more soon!
@irahartleib2722
@irahartleib2722 Жыл бұрын
I hope to see more exciting videos like this one in the near future! If you want to get more fans research Promo-SM!!!
@jasonwattsae
@jasonwattsae 10 ай бұрын
🤨
Siemens PLC to Drive Communication: Telegrams  in TIA Portal
21:01
Jason Watts AE
Рет қаралды 6 М.
Stay on your way 🛤️✨
00:34
A4
Рет қаралды 26 МЛН
Они так быстро убрались!
01:00
Аришнев
Рет қаралды 2,2 МЛН
Siemens TIA Motion - Back to Basics SINAMICS Drives webinar
1:54:05
Underwoods Ltd
Рет қаралды 9 М.
MS05f. [Siemens S120 #4b] Setup Motion Technology Object (TO) to Control S120 Servo Drive
30:04
Add S120 to Portal
8:48
Applied Controls
Рет қаралды 987
Siemens How-2-Drive - SINAMICS S120 Booksize - Swap C/D Motor Modules
6:47
Siemens Knowledge Hub
Рет қаралды 32 М.
TIA Portal: PLC Tags
12:23
Hegamurl
Рет қаралды 118 М.
TIA Portal Sinamics G120 control speed SINA SPEED
7:31
Muhamed Pasic
Рет қаралды 11 М.
Inbetriebnahme SINAMICS S120 mit SINAMICS Startdrive im TIA Portal
7:13
Siemens Knowledge Hub
Рет қаралды 41 М.
Arrays, Structures and User Defined Types! How and Why?
13:13
MS05d. [Siemens S120 #3] One Button Tuning S120 via STARTER and TIA Portal Startdrive
16:59
Electrical Automation Hands-On
Рет қаралды 7 М.
Частая ошибка геймеров? 😐 Dareu A710X
1:00
Вэйми
Рет қаралды 5 МЛН
تجربة أغرب توصيلة شحن ضد القطع تماما
0:56
صدام العزي
Рет қаралды 64 МЛН
Klavye İle Trafik Işığını Yönetmek #shorts
0:18
Osman Kabadayı
Рет қаралды 8 МЛН