3 Storey House Column Size and Steel Reinforcement Details

  Рет қаралды 60,410

Civil Engineers

Civil Engineers

Күн бұрын

Пікірлер: 51
@kalamanimkandhasamy3186
@kalamanimkandhasamy3186 2 ай бұрын
Respecte d sir now i construction my building i followed above instructions giving your vedio today I follow... heartfully thanks YoU....m.kandhasamy
@romycruz4498
@romycruz4498 Жыл бұрын
excellent presentation, namaskar - viewer from the Phils.
@LanguiYang
@LanguiYang 5 ай бұрын
What about stirups types? 2 legged or 4 legged?
@josephotim3912
@josephotim3912 11 ай бұрын
Great tutorial
@mirhossain6799
@mirhossain6799 3 жыл бұрын
Would there be any problem if I used 6 no of 16mm steel rods instead of 4 no of 16mm & 4 no of 12mm steel rods?
@suryak7696
@suryak7696 3 жыл бұрын
Won't be any problem as 16 is more than for 3 story building like ..more safety
@atromitos88
@atromitos88 Жыл бұрын
@@suryak7696 is it ok if i use 8pcs 16mm for 4 storey residential column spacing 3m.
@bharaths4250
@bharaths4250 2 ай бұрын
Over reinforcement and noy economical
@pradeepkumar12314
@pradeepkumar12314 Жыл бұрын
Sir, i have watched some videos mentioning that 6 bars of 12mm sufficient.i am confused which one is correct
@juliusjohn9453
@juliusjohn9453 Жыл бұрын
Please note Spacing between columns has been is extended to 18meters
@jangit9536
@jangit9536 3 жыл бұрын
What about the columns & beam for a 3 storey commercial building
@LouiseCabahug-tl5bq
@LouiseCabahug-tl5bq Жыл бұрын
I constructed 3 storey building it is safe if i use 4 16mm and 4 12mm for steel reenforcement for the column
@boogieman802
@boogieman802 9 ай бұрын
Can I use all 16 mm rod in column?
@jersonjimenez9538
@jersonjimenez9538 3 жыл бұрын
Please topic 3 commercial building, what column size and steel will be use?
@kiranpani
@kiranpani 3 жыл бұрын
Is Size of column 30x30 including concrete cover or just distance between corner roads ?
@kirubakaran8165
@kirubakaran8165 3 жыл бұрын
Including clear cover
@apphiasamuel.vlogs.6947
@apphiasamuel.vlogs.6947 3 жыл бұрын
Sir should i use 9x12 inch and 4 no 16mm 2 no 12 mm steel for 3 storey house building ?
@arijitkarmakar9045
@arijitkarmakar9045 3 жыл бұрын
In our area 4 16mm rod are used to make a 3 story building 🤣🤣
@atromitos88
@atromitos88 Жыл бұрын
@@arijitkarmakar9045 what size of column if 4 16mm rod is used
@phyohtetkoko929
@phyohtetkoko929 2 жыл бұрын
Thanks For Teaching sir
@badatiplangkharsohrmat5590
@badatiplangkharsohrmat5590 2 жыл бұрын
How much height of concrete at the footing needed.....?????
@waluohopaulo2116
@waluohopaulo2116 3 жыл бұрын
Well explained
@avtarsingh-or6qv
@avtarsingh-or6qv 3 жыл бұрын
Very useful tips.
@abderaufemohammed5458
@abderaufemohammed5458 3 жыл бұрын
Can I use 8 bars with 14mm instead
@rbordoloi9961
@rbordoloi9961 2 жыл бұрын
Can I use 6mm iron for stirrups for 3 storeys domestic building
@TheLazyGuyWay
@TheLazyGuyWay Жыл бұрын
16mm steel bars 8mm stirrups
@my_day963
@my_day963 3 жыл бұрын
Sir, experts say that a building columns size required 3 difference type of column
@yasinmulla5570
@yasinmulla5570 8 ай бұрын
Thank u sir 🙏
@froilancosape7027
@froilancosape7027 2 жыл бұрын
How about the beams of 3 storey building😊
@bluesky2143
@bluesky2143 Жыл бұрын
If 8 rods 16mm then??
@jesus2621
@jesus2621 3 жыл бұрын
If i use the column for 2 story and also use bearing brick can i build 3 floor?
@satheeshkumarduraisamy5938
@satheeshkumarduraisamy5938 3 жыл бұрын
5200SQFT construction of 3 story (15600 SQFT) building, GF 2300SQFT is for Car parking, Do we need the Plinth beam (12" * 18" ) to Connect all the Columns in the car parking as well ? Since there is no Wall but only PCC flooring.
@najeebullah065
@najeebullah065 Жыл бұрын
Thank you
@jimoelgumangan4091
@jimoelgumangan4091 2 жыл бұрын
Sir should be the size of collum when the area is a slope for residential G+3 story building
@agila9002
@agila9002 Жыл бұрын
My house was built by may neighbor carpeter ang its 3 storey . The colum size is 20 by 30 with 6 16 steel bar. The column distance is 3m and 2.25 meters on the other side.. sir is it okay..?
@atromitos88
@atromitos88 Жыл бұрын
how many column and total sqm of area?
@ericoiye2719
@ericoiye2719 3 жыл бұрын
That means The steel will have 240mmx240mm if we using 30mm cover.Then For Class M20 Concrete The mix is 1:2:4 and Not 1:1.5:3 as opposed thats for Class 25 Concrete
@akbarali9890
@akbarali9890 3 жыл бұрын
Plz explained the design of L type retaining wall for basement
@sanjidarahman4941
@sanjidarahman4941 3 жыл бұрын
Thank you sir
@satheeshkumarduraisamy5938
@satheeshkumarduraisamy5938 3 жыл бұрын
Column distance is 16 to 18 feet than what is the column and beam size for 3 story building
@my_day963
@my_day963 3 жыл бұрын
18 feet distance column size required 12"/12" and beam size required for is code 16 inches beam size for 16 feet columns distance, and 18 inches beam size for 18 feet column distance.
@bungoningthoujam1680
@bungoningthoujam1680 3 жыл бұрын
Plz explain about column for 3 storey building
@my_day963
@my_day963 3 жыл бұрын
This video for 3 storey domestic building
@bhaskarmondal8468
@bhaskarmondal8468 3 жыл бұрын
Sir Footing size=?
@talithaiitalithaii7261
@talithaiitalithaii7261 3 жыл бұрын
👍👍👍
@انعامالحق-ك6ص
@انعامالحق-ك6ص 3 жыл бұрын
کاکا نو په پښتو کی اووايه کنه انګرېزي ډېره مهمه ده که
@ronsinghshira8224
@ronsinghshira8224 9 ай бұрын
OK, thanks
@jerryjeremy4038
@jerryjeremy4038 10 ай бұрын
18ft???? that is too far my brother..
@ShahidulIslam-ri4ey
@ShahidulIslam-ri4ey 2 жыл бұрын
ভীম সাইজ কত
@Kse1010
@Kse1010 Жыл бұрын
Adhi info
@RamanJagdev-x9x
@RamanJagdev-x9x Жыл бұрын
Jai shree ram
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
Size of Beam , Size of Column and Spacing between Two Column
13:01
Civil Engineers
Рет қаралды 379 М.
Size and depth of Footing for 3 storey Building
6:34
Civil Engineers
Рет қаралды 7 М.
How to design of cantilever slab rebar and one-way slab reinforcement details
8:14
NHÀ XANH VIỆT NAM
Рет қаралды 4,3 МЛН
COMMON MISTAKES IN CONSTRUCTION - PART 1
14:27
Aron James Garcia
Рет қаралды 2,1 МЛН
Depth of Footing for Two Storey Building
10:35
Civil Engineers
Рет қаралды 173 М.