[45] APC Back-UPS 1000 Teardown

  Рет қаралды 5,907

GBC Productions

GBC Productions

Күн бұрын

Пікірлер
@MiguelGonzalez-ut8tn
@MiguelGonzalez-ut8tn 3 жыл бұрын
You say a couple of screws and I take out the front of the UPS and you didn't show how to do this, thanks. Soy de argentina.
@JoeAnshien
@JoeAnshien 3 жыл бұрын
I got as far as you up to 8 min. I needed the parts you did off camera! How did you get the front piece off and where are the "other screws you mentioned?
@MiguelGonzalez-ut8tn
@MiguelGonzalez-ut8tn 3 жыл бұрын
How did you get the front piece off? Saludos desde Argentina.
@KuntalGhosh
@KuntalGhosh 4 жыл бұрын
You seemed to have very little knowledge about inverters but all i wanted to see is the circuit board and thanks for that😁
@PrasanthSagark
@PrasanthSagark 4 жыл бұрын
Can those front panel buttons be replaced?
@danthegreat7590
@danthegreat7590 4 жыл бұрын
How do i remove the faceplate is it glued in or clipped in
@en2oh
@en2oh 4 жыл бұрын
Just for completeness, the 24vdc is converted to a high frequency pulse signal (35khz or something like that), which is then put through the transformer. The transformer steps the pulsed voltage up to ~170v pulsed DC which is rectified and smoothed (not 120v RMS ). It then goes into an H-Bridge that reverses the output at a set frequency NA is 60hz, and depending on how the H-Bridge is driven, you get either nearly "pure sine wave" using sinusoidal Pulse Width Modulation (SPWM) or more commonly, using a modified square wave driver. The former is much better for electronics. (If I have any of this wrong, please correct it for the benefit of others)
@REALBanannaman
@REALBanannaman 2 жыл бұрын
Mine stopped working wont turn on just beeps when you click the power button
@SivanandRavi90
@SivanandRavi90 5 жыл бұрын
Does the transformer in this unit uses the battery during voltage adjustments(avr mode) or only when it drops below the avr range(battery mode)?
@GBCProductions64
@GBCProductions64 5 жыл бұрын
I think it does switch to battery mode during over voltage as well. The sounds it makes as it switches modes sounds like it's using the battery. Now, that could be switching to battery mode as it changes taps on the transformer. I may try hooking a variac up to it just to see what it does.
@mashedpotatoes5323
@mashedpotatoes5323 5 жыл бұрын
This does not have a pure sine wave as it's the back-ups version not the smart-ups version
@kmonyt
@kmonyt 4 жыл бұрын
Thanks for taking the time to make this video. You keep saying that it takes the 12v DC and converts it. Don't you mean it takes the 24v and converts it? Those batteries are wired in series. If you look carefully on the sticker, you'll even see reference to 24v.
@GBCProductions64
@GBCProductions64 4 жыл бұрын
You are correct, it is 24 volts. That was a mistake on my part.
@oaxticmex
@oaxticmex 4 жыл бұрын
thank you!!
@The_Vodcasts
@The_Vodcasts 4 жыл бұрын
Not 12 volts but 24 volts with those two combined batteries. Thanks though...
@maljourn
@maljourn 4 жыл бұрын
Wow, if I wanted to know how to take it apart, the part you skipped in the beginning would have been the most important of this video.
@swapnilthorat3335
@swapnilthorat3335 2 жыл бұрын
Not open proprly. I am Not happy😢
Repair your APC Battery Backup....The Wrong Way?
28:42
DorkEnergy
Рет қаралды 36 М.
APC Back UPS Pro 1000 Battery Backup with LCD review (BR1000G)
10:09
Tech Guy Charlie
Рет қаралды 75 М.
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
UPS/Battery Backup Buyer Beware!!
15:58
Joe's Garage
Рет қаралды 67 М.
How does an Uninterruptible Power Supply (UPS) work?
16:00
Explorer
Рет қаралды 867 М.
APC SmartUPS Tower Unit won't turn on
5:48
CoastTec
Рет қаралды 141 М.
Apc F02 Error Solve Ups
10:25
DIY Marius Electro
Рет қаралды 14 М.
APC Back-UPS Pro 1000 BR1000G Disassembly and battery repair
13:44
Will Hennegan
Рет қаралды 89 М.
SUPER UPS Battery Hack- Mikes Inventions
8:45
Mikes Inventions
Рет қаралды 277 М.
Repair - APC Back-UPS M1000
15:30
z1power
Рет қаралды 53 М.