I just finished a service in my neighbors 95% York unit, complaint was that it lights but goes right out. Unit is in a small 2nd floor crawl space. The “pro” who was there just the day before changed the pressure switch for the inducer motor and “beat feet”. As soon as I turned it on the next day, the inducer squirrel cage sounded like it was UNDER WATER. Shut it down, removed the tube from the inducer outlet to the drain pan and pulled out a huge “booger” from it. Now the water flows freely, inducer motor is happy. Completed your checklist per the video, all is well. NEVER underestimate the importance of the condensate drain !!! Thanks again, another warm neighbor 👍👍👍
@robertwilliams62882 жыл бұрын
I am in hvacr school and really appreciate your informative videos keep them coming thanks for all you do. 👍
@acservicetechchannel2 жыл бұрын
Robert, thats so encouraging to hear, thanks!
@thecreativehuman752 жыл бұрын
Hey Craig, please make another book dedicated to furnaces. Sincerely, Everybody here. Thanks!
@acservicetechchannel2 жыл бұрын
I really would like to. That would take a bit because of all the fuel gas, electric and everything. I certainly would like to in the future. Stay tuned for our minisplit book coming out near the end of the year. Its almost done, thanks!
@deanriver93882 жыл бұрын
Do a video on combustion analysis and what the parameters should be. Thanks
@jw52972 жыл бұрын
Look up NCI all the info in the world about proper combustion
@acrservicesmathewr75652 жыл бұрын
Yes this is huge and always confusing to new techs especially since we only do heating certain times out of the year so it’s easy to forget and with new efficiency standards this could really help. On natural gas and LP. Thanks Craig
@jw52972 жыл бұрын
@Michael A Combustion really isn’t complicated If your not checking it on fuel burning equipment, you are WRONG.
@anarki85602 жыл бұрын
NCI has all the knowledge you will need. Be careful who you research or watch, because a lot of people are misinformed when it comes to combustion analysis.
@jw52972 жыл бұрын
@@anarki8560 Agreed
@ianicus1232 жыл бұрын
Scotch bright pads are best for the rod, the steel wool could cause scoring of the rod which actually causes the rate of deposit buildup to increase.
@riverratfishing2 жыл бұрын
Lots of useful information. Learning a lot from you. When ever I'm stumped on a unit, I go searching through your videos. Appreciate all your work
@acservicetechchannel2 жыл бұрын
Thats so awesome to hear, thanks!
@paulrozinski14882 жыл бұрын
No such thing as too much information when it’s 10 degrees outside at 2AM on Sunday morning and your furnace is “being naughty” . Great information as always.
@acservicetechchannel2 жыл бұрын
Thats for sure!
@chesstime3562 жыл бұрын
I really like it. I am Maintenance technician is there anyway to make step by step a furnace and heat pump maintenance videos? Thanks for your help
@acservicetechchannel2 жыл бұрын
We just try to focus on one topic at a time. Thanks for letting me know what you would like to see!
@pizzle10112 жыл бұрын
You never miss 👌🏾👌🏾👍🏾👍🏾
@Razor-RudyАй бұрын
Can you do a video on servicing Heat Pumps?
@kobie42382 жыл бұрын
Had the last one today on a tuneup and cleared it out
@acservicetechchannel2 жыл бұрын
Thanks! Nice!
@HB-tt1kn2 жыл бұрын
Thanks for informative video, would you please make a video about a master and sleeve thermostat how they communicate 🙏
@acservicetechchannel2 жыл бұрын
Thanks for letting me know what you would like to see, thanks!
@wahid67252 жыл бұрын
thank you so much teacher
@acservicetechchannel2 жыл бұрын
So glad to help!
@partshnc Жыл бұрын
The proactive advice and cleaning guidelines you provide in your great video will aid in preventing furnace failure, thereby lowering repair expenses. we offer quality furnace spare parts.
@jrfun46472 жыл бұрын
As always very good. Thank you!
@acservicetechchannel2 жыл бұрын
Thanks so much!
@schmitty992 жыл бұрын
Can you make a video for boilers and gas packs?
@acservicetechchannel2 жыл бұрын
Thanks for the video ideas Isaiah! I just put one out on zoning controls for boilers, thanks!
@myherocamus88472 жыл бұрын
What a great video!
@acservicetechchannel2 жыл бұрын
Thanks a lot Myhero Camus!
@Mudcat5972 жыл бұрын
Good information. Thanks for sharing. 👍👍
@Razor-RudyАй бұрын
How long should all this take? We are given 1 hour to complete heating service
@danpresson2 жыл бұрын
Are they facing out 410a
@acservicetechchannel2 жыл бұрын
Yes they are mainly moving to R-32 and R-454B in the US, thanks!
@jamessalvia48392 жыл бұрын
Craig , I have Trane S9V2 furnace, how do you get the furnace condensate trap out of that and how to clean. Thanks
@acservicetechchannel2 жыл бұрын
Some furnaces have removable traps and others do not. In those cases, just vacuum or blow it out in position, thanks!
@isaiahmedina93012 жыл бұрын
Any advice, got a job commercial install apprenticeship ? First day October 31st.
@jw52972 жыл бұрын
Read and watch. Are you going into an install or service position, that will narrow down what to tell you to start with
@isaiahmedina93012 жыл бұрын
Install commercial
@jw52972 жыл бұрын
@@isaiahmedina9301 I saw that just wasn’t sure what your overall goal was. Some guys will get into install and stay doing that until they retire. Others are more technically inclined and go that route. Install, just watch your lead installers, and do what they do, some will do things one way others another. Install is an art of its own. Great that you’re starting there. Learn to field fabricate transitions, most commercial won’t. They measure it and have a sheet metal shop make it. If you can fab it in the field you will be worth your weight in gold, because I can’t tell you how many times what you lay out and what you get sent to you won’t always be the same thing. Service is a whole other animal, and different level of commitment. Install guys in the commercial space aren’t likely to be called out for emergencies. Residential oh yeah. I’ve spent 23 years from residential to commercial to industrial, install, service, and now controls Has been a great life, hard but great, and supported at times two families, stick with it, don’t be afraid to ask questions, if your lead is a dick do what you can and move on, lots are when you’re new. But then lots aren’t either. Welcome to the industry
@isaiahmedina93012 жыл бұрын
Thank you man I appreciate the advice, looking forward to it and just to answer your question about whether install or service, I want to learn it all I want to be so valuable that I grow expeditiously. I would also love to learn plumbing and electrical. Didn’t grow up with a father wasn’t taught about tools or anything, so just want to be as educated as possible man to be honest with you. I’m 20 years old and just want to be known as having an incredible work ethic. And have that push me into growth within my career. Earn what work for man.
@jw52972 жыл бұрын
@@isaiahmedina9301 You’ve got the right mentality You’ll learn plenty about electrical and plumbing in this industry
@hammbone822 жыл бұрын
i wish you where more specific as to the age, manufacturer, and model number fore the type of Gas furnace your referring too based on the 500 Sq ft per ton usage fore the type of residential weather its a house or moblehome fore the unit use with this tutorial. but i do see you provided alot of links fore further tutorials
@acservicetechchannel2 жыл бұрын
I never say anything like 500 sq ft per ton. If you are referring to a heat load and loss calculation, I use wrightsoft, thanks!
@stephwaylonwells32182 жыл бұрын
👍
@jw52972 жыл бұрын
Just throwing this out there but if your running a PM or service call to a fuel burning appliance and your not doing a combustion test and analysis and removing and cleaning the flame sensor, shame on you! Be a technician, it literally takes 30 minutes and you could save a life, and you will definitely will save them money and prolong the life of the equipment, IE doing your job.
@anarki85602 жыл бұрын
Also educate the customer on the standard carbon monoxide detectors and how they work, and offer low level carbon monoxide monitors.
@jw52972 жыл бұрын
@@anarki8560 yep until the fire department tells them to ditch them Have had it happen many times. Nighthawk low level detects the home owner has opened the man door to the garage with the car running in garage with garage door open but the CO comes in and it goes off. Educating your customers and actually helping prolong the life of their equipment is why your there, earn your money and make the relationship with the customer! It will pay off in the long run.
@anarki85602 жыл бұрын
@@jw5297 yea we offer the NSI 6000 and I educate the customer the best I can while I'm there and am always educating myself to learn more and more about carbon monoxide and its effects. It's a scary thing and I feel like not enough people know about the different types of detectors and carbon monoxide in itself. I've had numerous customers thank me for educating them because they didn't know. It's truly rewarding.
@hardcoredrrk2 жыл бұрын
What could be the reason for a flame rollout switch to keep tripping (once per week or so)? Had a tech clean out the unit, he said it wasn't bad. Tenant has changed air filters pretty regularly. It's a higher end unit from '08.
@jw52972 жыл бұрын
Many things could cause it. Checking gas pressure and doing a combustion test would point out that culprit
@roberthayes81312 жыл бұрын
Probably a cracked heat exchanger. Flame rolling out.
@jw52972 жыл бұрын
@@roberthayes8131 Could be. Could be a leaking gas valve and not making all the way across the burners. Could be a faulting draft induce motor Could be improper gas settings Could be the exhaust is on a prevailing wind side of the home and catching wind gusts Could be a cracked heat exchanger, popped ring and gets hot enough and metal expands enough for the blower to affect the unit. Someone needs to put a combustion analyzer on it that knows what they’re looking at and can tell you exactly what it is.
@boby1152 жыл бұрын
Could be a lot of things. I once had a York unit that was driving me nuts until I caught the problem red-handed . I found the circuit board had an intermittent problem that would keep the igniter on after ignition from time to time . The igniter would get so hot it would trip the flame rollout switch.That was one job I had to pull a chair up on and cycle the unit over 20 times before it happened (i’ll never forget that furnace as long as I live,😅).
@hardcoredrrk2 жыл бұрын
Thanks all. Some great insights here. I'll be giving these suggestions a go and investigate more. Will reply back as well with an update for those curious. In the meantime, I showed my tenant how to reset the switch which she's been having to do still about once per week.
@mrofnocnon2 жыл бұрын
I can't believe you never mentioned cleaning the pilot. Still used in many older furnaces that are still out there.
@acservicetechchannel2 жыл бұрын
Certainly you are right on the money if they are not burning right, the pilot tube gets covered in soot and then the pilot flame gets choked out, thanks!
@mangoisback2 жыл бұрын
Boilers where are those videos!!!!
@jw52972 жыл бұрын
A boiler is just a furnace with water moving past the heat exchanger instead of air. Still has the same items to check. Gas train and pressure and limit switches Don’t get all caught up with it being water vs air, same same, it’s a fuel burning appliance,
@mangoisback2 жыл бұрын
@@jw5297 I agree with you as far as air and water , but furnaces and boilers are different. Yes they do the same job , as far as combustion yes they have the same principle but as far as components, electric etc way different. Furnace does not have a expansion valve , PRV , sight glass ( steam boilers).... I have been on the field for close to ten years , I like how he explains things and demonstrate the functions.
@jw52972 жыл бұрын
@@mangoisback Agreed. I thought maybe you were referring to the topic of keeping them clean and running. Yes the water side clearly is different but that can be made or broken by how well it is installed. And yes he does a great job of explaining things and his processes
@acservicetechchannel2 жыл бұрын
We just put up a boiler zoning control video last week, thanks all!
@johnwhite25762 жыл бұрын
there is NO tech Ive seen in forty years who does this on preventative maintainence. They do a drive dy and cursory inspection and then bill you $150.
@acservicetechchannel2 жыл бұрын
Oh really? Thats not good because this was only meant to be literally the basics but musch else shoulod be cleaned and inspected such as the blower wheel, ducting, etc, thanks!
@jw52972 жыл бұрын
Then you’ve got the wrong people coming to your home. Everything he went over is basic HVAC service call stuff for me. Your money should pay for something, not just a body showing up.
@zahedaminullah69342 жыл бұрын
Great vids as always, hopefully homeowners don't learn this because soon we will be out of a job!
@keitha51882 жыл бұрын
i doubt a 90 year old woman has a computer let alone tools to fix her own furnace!
@jimbosvidbits61662 жыл бұрын
No sound?
@acservicetechchannel2 жыл бұрын
There is sound. I tested. It must be on your device, thanks!
@williamsmith62 жыл бұрын
Let a professional company do the maintenance yearly, it’s safer
@acservicetechchannel2 жыл бұрын
For sure!!!
@357-e2r2 жыл бұрын
I disagree with flame sensor. I feel like it scratches the smooth surface and allows combustion products sit on it much easier. Once you clean it once, you need to clean it every year.
@acservicetechchannel2 жыл бұрын
You can clean it with whatever you would like as long asss it doesn't leave residue. Certainly don't use heavy steel wool, just fine, some people use brillow pad, some use dollar bill but just make sure to clean it off, thanks!
@jw52972 жыл бұрын
I use blue scotchbrite pads. And I always include a new flame sensor if I replace an igniter They’re $15-$25 and if your doing your job you’ve pulled it out anyway have your company adjust the price to cover the part time 1.5 and you’ve capitalized on your labor and added revenue and added value to that customers experience with your company. I’ve cleaned thousands of flame sensors and replaced around 75-100 in my 23 years. The replacement idea came to me 16-17 years in and working for a franchised company.