51. Points DC and DCC, Fitting point motors and Eletrofrogs

  Рет қаралды 14,190

Donegal Dad-Rail

Donegal Dad-Rail

Күн бұрын

Пікірлер: 32
@mikewillis9708
@mikewillis9708 2 жыл бұрын
Hi Mark, playing catch up but wanted to say this is a great tutorial video. Thanks for making!
@DonegalDadRail
@DonegalDadRail 2 жыл бұрын
Thank you Mike, glad it was of use to you.
@BeardClipper
@BeardClipper Жыл бұрын
Really useful video - thanks for putting this out here! That's cleared up so many questions I've had :) you're a star
@DonegalDadRail
@DonegalDadRail Жыл бұрын
Glad it was helpful! If you are every stuck just ask.
@BeardClipper
@BeardClipper Жыл бұрын
@@DonegalDadRail thanks mate :) much appreciated!
@moorlandmodelrailwayandy
@moorlandmodelrailwayandy 3 жыл бұрын
Once again Mark a very well explained and informative video, well done Andy
@DonegalDadRail
@DonegalDadRail 3 жыл бұрын
Thank You Andy.
@davidcook380
@davidcook380 3 жыл бұрын
Great Video You Explained It Perfectly Mark
@DonegalDadRail
@DonegalDadRail 3 жыл бұрын
Thank you David
@ModelTrainOutsider
@ModelTrainOutsider 3 жыл бұрын
Nice explanation and walkthrough, Mark! Great video!
@DonegalDadRail
@DonegalDadRail 3 жыл бұрын
Thank you Anthony, good luck back at school.
@simonfreeman7277
@simonfreeman7277 Жыл бұрын
Very well explained, thank you
@DonegalDadRail
@DonegalDadRail Жыл бұрын
Thank you Simon
@bluephantom2044
@bluephantom2044 6 ай бұрын
This may seem like an odd question but can you just have the three wires ,frog , positive and negative and the switch you use and still make it work but by only switching it from the track manually
@DonegalDadRail
@DonegalDadRail 6 ай бұрын
Yes you could do it manually. But using a switched point motor or a frog juicer stops accidental shorts, which over time could damage your loco's or power supply.
@bluephantom2044
@bluephantom2044 6 ай бұрын
@@DonegalDadRail I have done the three wires test and it seems to work I think if it shorts out it would just stop working but the locos run over with no problems
@ewoodrailway
@ewoodrailway 3 жыл бұрын
A couple of regrets for me..not using express points and not fitting point motors. Sadly will cause a load of work and issues if I was to do it now. Good work on your latest project
@DonegalDadRail
@DonegalDadRail 3 жыл бұрын
Its all part of the learning process with model railways, remember a layout is never finished.
@kimjong-un464
@kimjong-un464 Жыл бұрын
That made it very easy for me now. Can you please explain me how to use the micro switch under the solenoid motor for the light switches you mentioned.. Thanking you…
@DonegalDadRail
@DonegalDadRail Жыл бұрын
Not easy to decribe here will be doing a video on it in the future. But basically you would use the switch to power the lights making sure you use resistors and rectifiers where necessary
@bluephantom2044
@bluephantom2044 6 ай бұрын
I have one more question what size wires do you recommend i have found a 24awg 2mm on Amazon but im not shore what awg is and if it is important when in use on a point
@DonegalDadRail
@DonegalDadRail 6 ай бұрын
This is what I use www.rapidonline.com/rapid-gw010435-equipment-wire-red-7-0-2-100m-reel-01-0435 AWG is American Wire Gauge its how they size wire in the USA
@bluephantom2044
@bluephantom2044 6 ай бұрын
@@DonegalDadRail thanck you very much 🤠
@JKWARGAMES
@JKWARGAMES Жыл бұрын
Do you need to fit isolating fish plates if using Dc
@DonegalDadRail
@DonegalDadRail Жыл бұрын
It is best to fit isolating fishplates to cut down shorts and if two DC controllers are in use. If two controllers are in use you will need additional wiring. The double slip come with instructions on this. (Peco SL-90 Crossing, Double Slip)
@lennonbradfield5831
@lennonbradfield5831 2 жыл бұрын
Hopefully you see this, but which point motor do you use, because I can't figure out if it's the pm1 or pm4. Thank you if you do see this 😊
@DonegalDadRail
@DonegalDadRail 2 жыл бұрын
Hi Lennon I used both point motors. The PM1 was used on most of my points. On some of my points I used the PM4, as on these points the spring was either broken or missing and the PM4 has a latching mechanism to hold the point blades in position. Both point motors have built in switches to control the polarity on the electrofrogs. Hope this answers your question.
@lennonbradfield5831
@lennonbradfield5831 2 жыл бұрын
@@DonegalDadRail thank you this helps massively.
@chickenbites8877
@chickenbites8877 3 жыл бұрын
Can I ask how many droppers you need from your bus wires on a basic oval like this? (sorry for all the questions!)
@DonegalDadRail
@DonegalDadRail 3 жыл бұрын
You can get away with 4 droppers on a small oval in each "corner". The great thing when you run a buswire if you get a dead spot you can put in another dropper. Having dropper every couple of feet give good electrical continuity
@chickenbites8877
@chickenbites8877 3 жыл бұрын
@@DonegalDadRail brilliant thanks. And where a turnout connects to an inner oval, is that a couple of droppers at the end of the turnout, plus droppers in each corner of the inner oval? Also moving on from turnouts, assuming a simple loop of bus wire, how does one terminate the very end of the bus wires?
@DonegalDadRail
@DonegalDadRail 3 жыл бұрын
Have a look at this, see if it answers your questions kzbin.info/www/bejne/pqS6oayqh9Gka6s
LAYOUT WIRING for DC and DCC and all gauges at Chadwick Model Railway | 175.
35:07
Chadwick Model Railway
Рет қаралды 173 М.
How To Wire PECO UNIFROG POINTS - Model Railway Tutorial
14:28
That Model Railway Guy
Рет қаралды 27 М.
БАБУШКА ШАРИТ #shorts
0:16
Паша Осадчий
Рет қаралды 4,1 МЛН
Vampire SUCKS Human Energy 🧛🏻‍♂️🪫 (ft. @StevenHe )
0:34
Alan Chikin Chow
Рет қаралды 138 МЛН
УНО Реверс в Амонг Ас : игра на выбывание
0:19
Фани Хани
Рет қаралды 1,3 МЛН
ВЛОГ ДИАНА В ТУРЦИИ
1:31:22
Lady Diana VLOG
Рет қаралды 1,2 МЛН
SIMPLE Technique to Wire Up Points on Your Model Railway
12:10
Barnabas Junction
Рет қаралды 3,2 М.
Points - Essential Information (Incl. Wiring Electrofrog Points)
13:26
Little Wicket Railway
Рет қаралды 37 М.
Fitting point motors controlled by DCC
15:30
Simons Shed
Рет қаралды 128 М.
Model Railway 'How to' | Wiring up Peco Electrofrog Points | Dean Park 198
23:02
Dean Park Model Railway
Рет қаралды 139 М.
Installing Peco Electrofrog Turnouts (142)
25:59
Model Railroading
Рет қаралды 43 М.
How To Stop Derailments on Your Model Railway
17:57
Sam'sTrains
Рет қаралды 180 М.
БАБУШКА ШАРИТ #shorts
0:16
Паша Осадчий
Рет қаралды 4,1 МЛН