How to get to the advance settings on your heater and what they do.
Пікірлер: 40
@mikepell93263 ай бұрын
Really handy settings if you've got a smaller van, lower the pulse rate and the rpm and it'll run a little cooler so you don't need to keep turning it on and off again
@simplyboating46092 ай бұрын
You can change it to automatically go up and down by pressing and holding the top left button
@Retiredkiwi2 күн бұрын
re SN1 or SN2, according to manuals with my units(smaller print at end of manual), SN1 is the default, and is used for either having only 1 magnet on fan wheel or having 2 magnets of the same polarity facing sensor(all 4 of mine have 2 magnets and use the SN1 default setting), SN2 is also for 2 magnets, but with different polarities(ie 1 is north pole facing sensor and second magnet is south pole facing sensor). To fit a local (heatport voice multi controller) stop/restart temperature controller to one of mine(speaks what its doing when buttons pressed or for faults etc), i had a clearance issue with magnets hitting sensor, (new motor board supplied/needed as well) but found a mention somewhere, that they often can be pressed deeper into their holes, which fixed my problem. i run my other 2 (4th one is a spare) units at 1.5/8hz and 1500/5000rpm "AT SEA LEVEL" in my back porch(22ml pumps), and have never had a sooting up or smoking issue with them (4 and 5 years old now). One (claimed) 8kw one came with those settings, 2 other claimed 5kw ones came set to 5 or 5.5hz max originally, and last one bought came set to 1.4 / 7hz 1500 / 4500 rpm, so they vary a lot, but all are otherwise identical units in every way(white alloy case versions with chrome end cap). At 8hz setting, they all drink 0.5lts per hour at max output, but usually a bit less, as they throttle back via housing temp sensor unless porch is still very cold(which means no more than 4.5kw's as that's all the available energy in that amount of fuel. Lower settings will be proportionally less output than that(not checked, but guessing only around 3kw's at 5 hz.. (8hz output confirmed also by my calcs of delta t and airflow when i first got them). Just ordered another one today, will be curious what its supplied settings are (like the price drop over the years, first ones were$355nz, latest just $230nz delivered I did try one on a 28ml pump for while, but could never get it to run clean throughout output range, so gave up on it.
@simplyboating4609Күн бұрын
Great explanation.
@brianjohnson2175 ай бұрын
Thank you for you chd controller info . I've tried all the ways that other tutorials show how to access the pump pulse rate ie Hz and up to now nothing has worked. I'll try your method the next time I'm in my workshop
@simplyboating46095 ай бұрын
Hopeful it will work for you but since making this vlog i have come across 5 or 6 different controllers and some of them are not compatible with the CPU that comes with it. Before i could get this one working properly on my boat i had to change the CPC that was in it to a compatible one.
@cejs32737 ай бұрын
😅 simply THANK YOU ! Your efforts have NOT gone unnoticed! There IS a God im witness testimony. EXCELLENT Video fellow Englishman. 😊
@simplyboating46096 ай бұрын
Glad you liked it.
@stevegarrett1020 Жыл бұрын
Very helpful thank you.
@eldobarmusicjaywick4190 Жыл бұрын
Glad it was helpful.
@eldobarmusicjaywick41908 ай бұрын
Very helpful, Thank you.
@simplyboating46098 ай бұрын
Glad it was helpful.
@Jen-fy3pj8 ай бұрын
Easy to follow.
@crazycrab85784 ай бұрын
mine was on 1.7, went into settings, it would only go down to 1.6, put revs up to 1800, wonted to get the hz lower,
@autojohn-pu1vf4 ай бұрын
mine will turn all the way down to 0.8, but when you exit out of settings it only turns down to 1.7 hz as before and no change in pulse rate.... it clicks 102 times a min(drink,drink,drink,drink,) Trying to use less fuel it gets way hot enough. I also have a HCCAL w alpine mode I cant' get on, different controller but it clicks 132 X min(drink,drink,drink,drink,)on all the way low setting
@simplyboating46094 ай бұрын
Have you tried what autojohn suggested ?
@brettrob1980 Жыл бұрын
Need help I've the same one as you but the code won't work any more, I've used this setting before but it's not reading the code now
@simplyboating4609 Жыл бұрын
What is it your trying to do ? You say you have used the code before and it worked fine, has it just started not working ?
@kierenalvarez2 ай бұрын
Won't do anything. When pressing the setting 3times. Must have changed it
@simplyboating46092 ай бұрын
What are you trying to do ?
@Timblake545 ай бұрын
Hey, do you have any idea how to turn off the system completely? I tried holding on the power button but the fan kept blowing out cold air! I just ended up removing the fuze I had in
@simplyboating46095 ай бұрын
Hi, It should take about 10/15 mins to shut down from the time you turn it of so it can cool down and not damage your CPU.
@simplyboating46095 ай бұрын
Hi Tim, I have just looked it up and if you are waiting the 15 mins and it's still not shutting down then it my be that you motherboard is not working properly but try giving it 20 mins to cool down first and go from there.
@paulowen39345 ай бұрын
@@simplyboating4609 when its blowing cold air on startup it could be faulty temp sensor
@Louis-wr9ft7 ай бұрын
How do you work all this out ?
@simplyboating46097 ай бұрын
It just takes time.
@user-fp5pw3cv8s5 ай бұрын
None of the codes work how would I find the code for my heater to get into settings
@simplyboating46094 ай бұрын
I have never come across a different code 1688 is the only one i know of. Is it doing all the rest like pairing with your remote ? If not it maybe the CPU.
@Retiredkiwi3 күн бұрын
i have read some are 9009, not seen any myself though.(also i spotted 888 for some with only 3 digits)
@guidelineuk487611 ай бұрын
You missed out the glow plug setting( P.5) is the factory setting :-)
@simplyboating460911 ай бұрын
Sorry if i missed something and thanks for the help understanding how it works.
@guidelineuk11 ай бұрын
@@simplyboating4609 no need 2 apologise 😊 your video helped refresh my memory I have mine set at 1.4 Hz to 3.5 Hz 1500 rpm to 3500. The fan runs nice and quiet. Glow plug p5 ..... Just replaced glow plug and Gaskets. Running well fingers crossed.. thanks again for the video.. stay warm
@Retiredkiwi3 күн бұрын
I have read 2 different answers to this setting, pf 1=35watts, 2=40w, 3=45w, 4=80w, 5=85w, 6=90w from the fine print in 3 supplied manuals, but elsewhere it has been said that, each step up equals a longer time running glow plug, before pump starts, never tested if this is true, but i have not seen various other wattage plugs advertised anywhere?
@hauntingghosthunts5984 Жыл бұрын
Also don't see why you would change them if it works ok.
@barrylawrence83297 ай бұрын
3 things. 8k diesel heaters come set as 5k. You can change the blower settings as well as the herts. Also to make you ask questions.
@ian.new.life. Жыл бұрын
Wow that's set up very bad way too much fule not enough air. It will carbon up quick that's even lower fan speed than most factory settings.
@simplyboating4609 Жыл бұрын
It just how it was set when i got it and I've never had a problem with it so never changed it. Its been working fine for about 3 years, the only thing i do is turn it to max sometimes for about 5 mins to help clean the plug.
@Ryanoutdoors7 ай бұрын
What is the proper setup then?
@paulowen39345 ай бұрын
@@Ryanoutdoors there is no one right setting...it varies between different heaters and altitude etc....they come from factory with default settings which are to tuned in the advanced settings for different burn mixtures etc....you will have to experiment to get it burning efficiently....mine was running fine for a while now i get regular e08 and flames out so i need to adjust mine