This is How to Test and Read Voltage on a 750mv DC THERMOPILE POWERPILE. I go over what the Open Circuit Voltage should be and the Closed Circuit Voltage. I go over what you can do if these DC millivolt readings are off. I discuss the types of units that these can be found in and other tips! Supervision is needed by a licensed HVAC Tech before doing this as Experience and Apprenticeship garners Wisdom and Safety.
Tools Used In The Video
UEI DL379B Voltage Tester: amzn.to/3t5Cx8m
Magnet Jumpers- amzn.to/2PyKPQZ
Alligator Jumpers- amzn.to/2PxqJXn
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos/Articles
• How the Millivolt Gas ...
• 750MV DC THERMOPILE PO...
• Water Heater Pilot Lig...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicet...
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicet...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtoo...
Refrigerant Charging Book and E-Book: www.acservicet...
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicet...
Our Newest Articles: www.acservicet...
Try our HVAC/R Quizzes! www.acservicet...
Our Other Resources: www.acservicet...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicet...
Our Tool List on Amazon: www.amazon.com...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtoo...
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.c...
Apple Podcasts: podcasts.apple...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided. ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #thermopile #gasvalve #mv #gasburner #burner #pilot #diagram #wiringdiagram #pilotlight #mainburner
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Пікірлер: 45
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is a link to the UEI DL389 Multimeter used in the videos- amzn.to/2av8s3q Here is the link to the Fieldpiece SDMN6 Dual Pressure Testing Manometer with Pump-amzn.to/2jyK5Ka Here is a link for the Supco Magnet Jumpers amzn.to/2gS4h6z Here is the link for the Irwin Wire Stripper/Cutter/Crimper amzn.to/2dGTj2V Other tool links can be found in the video description section. ACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.
@hamidkiana1
@hamidkiana1 4 жыл бұрын
Thanks, your video helped me a lot for fix my fireplace.
@acservicetechchannel
@acservicetechchannel 4 жыл бұрын
You are welcome!
@m.n.3490
@m.n.3490 5 жыл бұрын
Great video. Short, and factual.
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
Thank you very much!
@catalinaparamo7184
@catalinaparamo7184 4 жыл бұрын
I ordered a new thermopile off ebay. with the pilot on, the fire place ignites at 240 mv and the reading keeps going up till it reaches around 350 mv then after a couple minutes the fireplace in turns off. Idk what it could be.
@ryanhart6790
@ryanhart6790 4 жыл бұрын
Kick ass video this guy knows his shit
@mark.r8900
@mark.r8900 6 жыл бұрын
thank you for this great video. does it matter which of the leads (red or white) from thermopile is connected to the thermostat? thanks.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
The thermostat is not being powered by the millivolts and is just breaking the wire so no it wouldn't and you are only powering dc solenoids, thanks
@mmangla5575
@mmangla5575 6 жыл бұрын
Thank you for the information
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Thanks M mangla!
@timothygriscom7110
@timothygriscom7110 6 жыл бұрын
I have this in my American Standard boiler. A bit of debris in the pilot orifice caused the flame to miss the thermopile and a failure to start the gas valve.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
I hear you! I find debris in the pilot tube quite a bit as well as oxidation on the outside of the thermopile, thanks Timothy!
@anthonycoker9348
@anthonycoker9348 Жыл бұрын
How much current can it generate at 750mvdc.
@vegaslowblower8781
@vegaslowblower8781 5 жыл бұрын
So when the pilot is on, you want the reading to be 350-850, and when gas valve opens it drops down to 200?
@daveschroers4222
@daveschroers4222 8 жыл бұрын
Another great video. Thank you acservicetech.
@chrisblewden1712
@chrisblewden1712 3 жыл бұрын
you should also refer to ionisation rods and U.V. faults ...
@SupercarGarageUSA
@SupercarGarageUSA 8 жыл бұрын
Great video, thank you!
@acservicetechchannel
@acservicetechchannel 8 жыл бұрын
Thank you!
@2manycatsforadime
@2manycatsforadime 5 жыл бұрын
OK, checked the Mv at the thermostat and I get 450. The floor furnace is hard to light and when it does runs then turns off in 15 minutes. 450Mv at the thermostat, when the furnace lights and is running it shows 0 Mv at the two wires at the thermostat. What am I missing? Looking into the furnace the flame at the thermopile looks very weak
@eliotorona4753
@eliotorona4753 8 ай бұрын
Thank you
@kevinwallace9829
@kevinwallace9829 2 жыл бұрын
I'm trouble shooting a propane wall heater that has a seemingly identical thermopile. Will a faulty thermopile prevent me from successfully lighting the pilot flame? Thanks in advance.
@Jason-wc3fh
@Jason-wc3fh 2 жыл бұрын
No. a faulty thermopile prevents the flame from staying lit when you let go of the button since the coil isn't getting enough energy in the gas valve to keep that pilot lit. Having trouble lighting is a gas problem (bad propane or too low a pressure), or pilot orifice plugged, or possibly a gas valve problem with the switch being depressed and it just won't let the gas through to the pilot tubing.
@kevinwallace9829
@kevinwallace9829 2 жыл бұрын
@@Jason-wc3fh Thank you sir!
@watchyerstep
@watchyerstep 6 жыл бұрын
Thanks for the great video as well as all the links. Question: I need a new Tp for my gas fireplace, is the HW Tp you have in the video ($60 I think) much better then the P/N 51827 Tps that seem to vary between $7 and $40? Are there "knock-off" Tps that would compel me to buy the HW? Thanks again.
@acservicetechchannel
@acservicetechchannel 6 жыл бұрын
Yes that one was the Honeywell version which is the good one with the metal sheathing. I have seen wires burnt up and thermopiles not lasting long so I linked the good one, thanks- 750mv DC Thermopile with metal wire sheathing amzn.to/2bpfBGc
@truenorthmuskoka9077
@truenorthmuskoka9077 4 жыл бұрын
My mVDC reading is only 10 when the circuit is closed and 550mVDC when circuit open. Does that mean my thermopile is bad
@geoa9722
@geoa9722 5 жыл бұрын
I thought flame rectification goes after the gas valve is open , so, once the gas flows then the rod is in the flame
@acservicetechchannel
@acservicetechchannel 5 жыл бұрын
This type of flame proving method does not use flame rectification but uses he generation of DC Millivolts, thanks George!
@perrygimlet2403
@perrygimlet2403 4 жыл бұрын
I have a square shaped thermopile in my downdraft furnace(ca, 1956), and cant find a new one anywhere. This is needed before the winter season starts..anyone help?
@andyandrafa6649
@andyandrafa6649 5 жыл бұрын
what are the difference between thermopiles and thermocouples?
@Jason-wc3fh
@Jason-wc3fh 2 жыл бұрын
thermopile is basically a PILE of thermocouples together as one... It's just a bigger version that produces more power because of what it will operate instead of what a thermocouple will operate.
@momoelyas5856
@momoelyas5856 7 жыл бұрын
Thanks
@acservicetechchannel
@acservicetechchannel 7 жыл бұрын
Thanks Momo!
@BYENZER
@BYENZER 4 жыл бұрын
Also called a "PILOT GENERATOR".
@mark.r8900
@mark.r8900 4 жыл бұрын
hi, i did this same testing procedure and got around 700m with only pilot on hitting the thermopile. But as soon as i connect wires to TH/TP and TP the voltage drops to around 114mv.burner won't come on. i tapped valve lightly then burner comes on? what's causing this drastic drop? bad thermopile or bad gas valve? thank you.
@nutsnbolts76
@nutsnbolts76 Жыл бұрын
I have the same issue. Did you ever resolve this?
@mark.r8900
@mark.r8900 Жыл бұрын
It was a weak thermopile. It's voltage dropped drastically once underload.
@spartan5106
@spartan5106 Жыл бұрын
cool
@1stFlyingeagle
@1stFlyingeagle 2 жыл бұрын
Also remember. What ever your reading is. The solenoid is going to suck half of it. If reading was 700mv now connect to gas valve. reading will drop to about half the voltage value.
@jcope04
@jcope04 4 жыл бұрын
your explanation seems to be double talk. at the beginning you said the test was being run on a thermopile that had failed; but the actual test showed it was well over the (350?) minimum. A few other comments gave you an opportunity to explain furthur, but you did not. Question--is this a good or bad thermopile? What makes it bad? For a complete test do you need to know what the voltage is when the part is actually in use? and if so, then how do you test it when you can't get the gas to continue flowing? I am not well versed in this, but am having a problem with a Vermont Castings free standing gas stove that uses gas logs, and can not find anyone to service it and this type of answer doesn't really help. thanks for listening
@gman76utube
@gman76utube 3 жыл бұрын
Yes frustrating. He focused only on heating a thermocouple and explained how a multimeter works. It seems that as long as the thermocouple generates at least 150mV is so, this will be enough to turn the gas valve on. In my case, I have a wall switch for a gas fireplace. The valve is activated by the wall switch but also the thermocouple voltage needs to be above a threshold. When I throw the wall switch on, the thermocouple reading goes from 320mV down to 160mV but the valve stays on. Before I put a meter on it, the flames weren't coming on. Pilot is on the whole time, and wall switch works fine, so it must be the thermocouple. But what I don't understand is why the mV reading drops since thermocouple temperature didn't change in just one second. Maybe the valve is doing something weird.
@chrissipple1018
@chrissipple1018 2 жыл бұрын
This video is not explained very good, I have not come crossed any videos that really explain the voltage reading of an open circuit and closed circuit readings.
@vegaslowblower8781
@vegaslowblower8781 5 жыл бұрын
I was good untill the end, then it got confusing
@chrissipple1018
@chrissipple1018 2 жыл бұрын
Your not the only one, not explained very good.
How the Millivolt Gas Valve and 750mv Thermopile Work! Troubleshooting!
8:53
AC Service Tech LLC
Рет қаралды 244 М.
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
What is the Difference Between a Short Circuit and a Ground Fault?
16:18
EEVblog 1622 - The BIG BEGINNER MISTAKE with Multimeters
12:25
How to use a multimeter like a pro, the ultimate guide
12:55
James Gatlin
Рет қаралды 2,9 МЛН
3 Ways to Check Capacitors in Circuit with Meters & Testers
14:48
TampaTec
Рет қаралды 1,8 МЛН
Teardown Tuesday Episode 23: RobertShaw Combination Valve
25:59
Tech Videos
Рет қаралды 17 М.
The thermocouple compared to the thermopile.
6:01
grayfurnaceman
Рет қаралды 416 М.
Voltage Drop Testing ~ The BEST Way To Test Wiring
9:54
HumbleMechanic
Рет қаралды 276 М.
The ONE Electrical Tool That Can Replace Them All!
16:57
How To Home
Рет қаралды 726 М.
HVAC Thermal Limit Switches, Safety Sensors, & Troubleshooting!
16:22
AC Service Tech LLC
Рет қаралды 190 М.
Gas Furnace SPARK IGNITION Operation and Testing!
17:07
AC Service Tech LLC
Рет қаралды 110 М.