Gas Furnace SPARK IGNITION Operation and Testing!

  Рет қаралды 104,368

AC Service Tech LLC

AC Service Tech LLC

Күн бұрын

Пікірлер: 114
@jimbarron8688
@jimbarron8688 Жыл бұрын
No need to look any further for a video covering direct spark ignition furnaces. This is the holy grail. Very thoughtful and thorough presentation.
@zahedaminullah6934
@zahedaminullah6934 2 жыл бұрын
Great videos as always. Well explained and I love the way you laid out all your components. This helps all of us a lot. Keep up the good work as always!
@zproxiimiity7733
@zproxiimiity7733 2 жыл бұрын
I love the way you teach! Your wording is on point. Hands on is the cherry on top!
@BeardGawd88
@BeardGawd88 2 жыл бұрын
I always double check power. Great stuff, my company doesn’t teach this stuff, glad i can learn on here!
@grashoprsmith
@grashoprsmith 2 жыл бұрын
Isn't that sad
@5822huron
@5822huron 2 жыл бұрын
There comes a point where you as a tech must educate yourself. Don't wait or expect any company to get you there.. Trust me! They wont
@USA-GreedyMenOfNoIntegrity
@USA-GreedyMenOfNoIntegrity Жыл бұрын
Most don’t because of high turnover, takes away profits and they’ll just be teaching their future competition.
@HANDYMANDAN51
@HANDYMANDAN51 2 жыл бұрын
Awsome , every heating service should view this,thanks.
@mathman0101
@mathman0101 2 жыл бұрын
Craig you are going to need a furnace book to complete the set of books you already have and your videos then act as a great complement. Always well explained and laid out.
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
Thank you so much!!! That last book took two years!
@mathman0101
@mathman0101 2 жыл бұрын
@@acservicetechchannel anything good always takes time and effort to plan and then write.
@germanrivas9925
@germanrivas9925 Жыл бұрын
Thanks!
@acservicetechchannel
@acservicetechchannel Жыл бұрын
Thanjks so much German!
@juanital.2608
@juanital.2608 Жыл бұрын
You are This Old House crew worthy. Great job, great speaking voice. You'd be great on their show. This is exactly how they explain things & why i love it. You've got another new follower in me. Great job, keep it up! 👏👏👏
@jimmylanders2175
@jimmylanders2175 2 жыл бұрын
Great video Craig and very thorough.
@HfJax
@HfJax 4 ай бұрын
Thanks a lot your channel is gold for technicians like me to expand their knowledge and skills to serve our customers better
@jed837
@jed837 2 жыл бұрын
Craig, you have wonderful videos for those coming up into the HVAC/R trade. Well explained . I’ve been in the trade over 30 years, and I’ve gotta say this is good stuff. Keep up the good work and happy new year!!!
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
Thanks so much Johnny!!!
@stevencossaboon3237
@stevencossaboon3237 2 жыл бұрын
Great video Craig. Thank you.
@coolramone
@coolramone 2 жыл бұрын
Thanks Craig! This will help me fix my gas furnace that won’t stay lit for more than a few seconds. It’s probably the flame rod not sensing flame and either needs cleaning or replacing, but now I know how to test the flame rod, thanks to you. URDB (you are dee best!) :)
@xxycom8963
@xxycom8963 2 жыл бұрын
Clean the flame sensor
@5822huron
@5822huron 2 жыл бұрын
Rarely will you replace a fs
@rammyfernando
@rammyfernando 2 жыл бұрын
very beautifully explained
@gideonlord-adem
@gideonlord-adem 2 жыл бұрын
Great experience with good explanations
@coldfinger459sub0
@coldfinger459sub0 2 жыл бұрын
I wish training videos like this were available when I was a kid since my dad forced me to learn at the age of 12 and we had to order books through snail mail or request our local library to order them which would take 5 to 8 weeks for delivery. Back before the Internet was invented..
@1984juant
@1984juant Жыл бұрын
Greetings👋. Do this mean anybody can service their own furnaces? I dont like that prospect.
@THExBIGxBADxWOLF93
@THExBIGxBADxWOLF93 10 ай бұрын
Better that way because you really learn compared to this I’ll learn and forget just because it was too simple
@coldfinger459sub0
@coldfinger459sub0 10 ай бұрын
@@THExBIGxBADxWOLF93 it good for the simple ones who get over whelmed seen too many things that are spread out . Some students learn better when everything is like on one page in front of them . Have to teach different types of students learning abilities differently. Some students can learn just by reading words without ever seen an actual furnace . Other students literally have to put their hands on the pieces take them off and put them back together before they learn . It all depends on the type of student you are teaching .
@Yeti808
@Yeti808 Жыл бұрын
Amazing job explaining the operation of a spark ignition. Thank you boss man!
@deanmartin1966
@deanmartin1966 2 жыл бұрын
Once again, excellent explanation. Thanks for sharing.
@RZeee..
@RZeee.. Жыл бұрын
Great illustration. Thank you!
@mouseley
@mouseley 2 жыл бұрын
Great video, very well organized and laid out. Great lab setup.
@christopherborner1139
@christopherborner1139 Жыл бұрын
Craig, once again a great explanation! Thank you so much. You explain things so precise and simple. Love the video.
@davidwilliams729
@davidwilliams729 Жыл бұрын
Love this guy! Thank you for making this video
@victor.mnoriega3586
@victor.mnoriega3586 Жыл бұрын
I really love your classes, Thank you.
@acservicetechchannel
@acservicetechchannel Жыл бұрын
You're very welcome! Thank you for enjoying our content!
@panchobarajas3008
@panchobarajas3008 Жыл бұрын
Good video thanks Craig
@joshuaadkins9998
@joshuaadkins9998 11 ай бұрын
Excellent tutorial. Great video! Thank you
@estebancastro6297
@estebancastro6297 2 жыл бұрын
Gracias!! Well explained
@juanflor6661
@juanflor6661 2 ай бұрын
Thank you for upload
@noahoyeah
@noahoyeah 2 жыл бұрын
Wow! Very good video!
@martini4620
@martini4620 Жыл бұрын
A couple months ago we installed a 95% Ruud furnace.It is now rusting very bad , the inside of the inducer collected some orangish rust. Even drain coming out is orange/rusty. Has correct gas pressure. Has both exhaust and intake going outside. RUUD Model # R95TC0701317MSA
@Yeti808
@Yeti808 Жыл бұрын
Proper duct sizing?
@westsidehvac1097
@westsidehvac1097 2 жыл бұрын
beautiful video
@repairitdontwreckit4257
@repairitdontwreckit4257 Жыл бұрын
Another excellent video. Thanks
@rj.parker
@rj.parker 2 жыл бұрын
The only clarification I would offer is flame sensing microamps (ua) is present on the sense wire as well as the ground wire. You need both to complete the circuit.
@chrisdeanndavison3626
@chrisdeanndavison3626 2 жыл бұрын
True, and I believe Craig covered this starting at about 8:00 through 10:00.
@jaysingh-ho7eb
@jaysingh-ho7eb Жыл бұрын
Great video! Thanks
@davidnecky8524
@davidnecky8524 2 жыл бұрын
Excellent video as always!
@ivanl8613
@ivanl8613 Жыл бұрын
exelent videos !!!
@technician9722
@technician9722 2 жыл бұрын
Great video.
@Onatena
@Onatena Жыл бұрын
Great video Thanks a lot 🙏
@Sightthrough
@Sightthrough 2 жыл бұрын
I'm curious about the voltage on the flame rod, when we test flame rods in the field we always measure the signal from the rod in Microamps DC, I didn't realize there was also A/C voltage on the flame rod, so the signal from the flame rod to the board is measured in microamps, DC, but the rod also has a potentially high A/C voltage on it? Could you share more about this?
@chrisdeanndavison3626
@chrisdeanndavison3626 2 жыл бұрын
It is flame rectification. I know I'm not explaining this by the book, but basically, the AC voltage present on the flame rod is rectified by the flame to DC. It is just a phenomenon that happens when AC voltage is in a flame. The flame conducts a very small amount of DC current to ground, this is the uA DC that we measure. This is why the ground on a furnace is just as important as the hot and neutral. Also, rusty burners can inhibit the current flow. 14:30 Craig explains this pretty well.
@Sightthrough
@Sightthrough 2 жыл бұрын
@@chrisdeanndavison3626 Thanks! My fault for posting the question before finishing the video.
@coolramone
@coolramone 2 жыл бұрын
So there are ac micro amps AND dc micro amps running through the flame rod, and which one is being measured by the pc board, ac or dc?
@jynnandtonnyx
@jynnandtonnyx 2 жыл бұрын
@@coolramone the way I understand it is : there is AC power (different than voltage) available to the flame rod. When the circuit is closed by the flame, the AC power is rectified by the flame to a small DC circuit which can be measured in micro amps. The flame is the switch.
@rj.parker
@rj.parker 2 жыл бұрын
@@coolramone dc microamps
@indiantraveller194
@indiantraveller194 Жыл бұрын
Great job sir 😘🙏
@manuelcastillo8472
@manuelcastillo8472 Жыл бұрын
Thanks nice and clear
@bill98778
@bill98778 2 жыл бұрын
Great video!!! I wish if you would have a video about domino’s pizza chain oven, thank you Craig and happy new year 2023🎉
@edwardgarza5104
@edwardgarza5104 2 жыл бұрын
Is there a step up transformer inside that board to be able to send 120 vac to the flame sensor?
@caru3257
@caru3257 Жыл бұрын
120v is present at the board and it doesn’t require a step-up transformer.
@marcosaguilera1760
@marcosaguilera1760 8 ай бұрын
Good morning, excellent explanation and I like your videos, you know a lot, I have a question about my furnice, when it calls to turn on the sparks it clicks for 30 or 40 seconds and it turns on and works well, what could be the reason, thank you
@paulthibodeau1269
@paulthibodeau1269 Жыл бұрын
Great video! I have a Rheem direct spark ignition unit. The unit would short cycle where the burner would light and burn for about 4 seconds then shut off. After a few attempts, it wouldn't do anything for about an hour. I couldn't call anyone because of my work schedule and it being a holiday week also. I took a shot and ordered a new dual electrode spark ignitor from Amazon, which showed up in only 2 days. After I installed it, my heater works perfectly. Was this just a coincidence or does the spark ignitor have something to do with the flame rectification process? (it was labeled ignitor/flame sensor) Thank you.
@landonwinkler5835
@landonwinkler5835 3 ай бұрын
They sometimes are combined with a third rod coming in front of the burner as the flame rod. The older Airease units are that way also.
@Kh2456
@Kh2456 Жыл бұрын
Having issues with my raypak pool heater. I have identified it down to a flame rectification issue as the pilot lights well and doesn’t activate the main gas valve for burners. Today I attempted to test the negative for micro amps (disconnected from gas valve) I connected it in series and couldn’t get a micro amp reading. When unplugging I got electrocuted by touching one probe of the multimeter when the positive was plugged into the negative. Why would the negative be carrying an electrical charge from the motherboard? Thanks
@waltherherrera67
@waltherherrera67 Жыл бұрын
Excelente muy bien Gracias
@aidanpeluso8350
@aidanpeluso8350 Жыл бұрын
Can you make a video explaining common/neutral wires. What they are, why they are there and what they do?
@odishoodisho4904
@odishoodisho4904 Жыл бұрын
If the module go bad and need to be replaced should we have to look the same one or there is an universal will work with all models ? And it needs to do some changes or just we can put it direct without any changes thanks in advance
@takleung7130
@takleung7130 2 жыл бұрын
24V into the ignition module but 120V out to the sense wire. Is there a step-up transformer in the module? Am I missing something?
@pointblankmatt6580
@pointblankmatt6580 Жыл бұрын
i mean it also provides 10000 volts for the ignitor. was curious about this as well. has to be something internal in the ignition control
@d.c2123
@d.c2123 2 жыл бұрын
BRAVOOOO!
@sonle-fz1xb
@sonle-fz1xb 2 жыл бұрын
Thank you so much
@christiansnyder1746
@christiansnyder1746 2 жыл бұрын
Craig I have a stupid question If there is only 24 V going to the ignition module, how does it produce high voltage?
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
There is a low voltage to high voltage transformer under the hood of the icm.
@aifrisyad7491
@aifrisyad7491 Жыл бұрын
great video…suggest more video about intermittrnt gas valve with ignition control…thanks anyway
@Hvacmaniac97
@Hvacmaniac97 2 ай бұрын
Does this apply to hsi ignitors as well?
@RC-Heli835
@RC-Heli835 11 ай бұрын
My old 1986 System does not seem to have a flame rod. It just has the old school honywell intermittent igniter and sparker and the fan limit switch.
@eloy09
@eloy09 Жыл бұрын
I was troubleshooting a lochinvar water heater. Same principle though, what happening is it will prepurge and trial for ignition again and again. What should be the problem? No flashes
@Team99-g3x
@Team99-g3x 5 ай бұрын
When the AC voltage is sent down for the sparking across the the probes(or probe and burner ) to the ground to make the circuit , the flame sensing probe is also sending ac down to the flame to convert to DC for same ground to prove? Is the flame rectification proven after the sparking stops , like a window of time ? As it would be AC from the spark and DC from the flame proving or am I getting confused ? Or is it possible to sense both at the same time from the same ground ? Anyone’s insight is helpful tia
@Team99-g3x
@Team99-g3x 5 ай бұрын
8:17
@mohammedalobaidi9981
@mohammedalobaidi9981 Жыл бұрын
👏👏👏
@Morbidhouse
@Morbidhouse 11 ай бұрын
I'm getting a voltage drop in the MC terminal, when the wire is connected to the gas valve it is only reading 15vac however when it is disconnected from the gas valve it reads 26vac. The pilot is sparking and lighting and blower is turning on however this drop in voltage seems to be preventing the burners from coming on. Would it be the gas valve or the ignition control module at fault?
@MrSnomanjankens
@MrSnomanjankens 2 жыл бұрын
I had a headache yesterday with a direct spark ignition furnace, except it had a pilot ignition assembly with a single flame rod. The ground wire was hanging on by a thread & was enough to not not give it proper ground. Also the pressure switch was constantly opening and closing since the inducer is on its was out only pulling .67” of WC on a .70” WC switch. The arching from the spark ignition due to the opening/closing of the pressure switch I think may have caused the pilot assembly ground to fail? 🤷
@YTsux24-7
@YTsux24-7 2 жыл бұрын
Frankenfurnace by AC Service tech! Awaiting UL approval...
@عليحسين-ع8ل4ب
@عليحسين-ع8ل4ب 2 жыл бұрын
Thanks
@davidekhalil944
@davidekhalil944 2 ай бұрын
Soo.. since my boiler does not have a "sense", that flame rod is the same as the spark ? So that current is happening through the spark and thats why it has spark/sense?
@light0000
@light0000 Жыл бұрын
Is it possible the flame sensor is bad and wouldnt let my HSI igniter to glow?
@mplscarsales6652
@mplscarsales6652 2 жыл бұрын
Hi my furnace always had at least 1 click I hear before start up and fan kicking on but lately I been hearing 2-3 clicks/Spark before the blower motor kicks on is that normal ? Same clicks I hear in your video at 8:16 but yours clicks/sparks much more .
@mrgibsoncat
@mrgibsoncat Жыл бұрын
hit it with soft sand paper
@jesparza602
@jesparza602 2 жыл бұрын
I've been looking for a video like this! As always, your explanations are clear and succinct. Thank you! Do you by chance have a book where you detail this?
@howgoodd
@howgoodd 7 ай бұрын
What about a faulty module? How can you troubleshoot for that
@Purifiedinfire
@Purifiedinfire 11 ай бұрын
My furnace has a control board for everything. The inducer fan goes, the spark ignitor clicks, the gas valve opens in short few second spurts a few times but it won't light. While doing this the furnace clunks or clicks like a gas valve or relay. The best I can gather it's a rusty buner tube not getting ma back to ground or a bad ground and it cutting the gas quickly then retrying a few times before giving up for a few minutes. The part I don't understand is why the clunking or clicking. The furnace doesn't do this all the time just sometimes.
@EC20121
@EC20121 Жыл бұрын
Flame roll out switch, cannot find a replacement for mine, keeps tripping can you help me find a replacement for it? Thank you
@jimbarron8688
@jimbarron8688 Жыл бұрын
A flame rollout that is constantly tripping is usually a sign of a cracked heat exchanger and is very bad news. These switches are generally very reliable so you'd be fortunate if a replacement solved your issue. A CO detector near the burners when it's running might show high CO as would a washy flame pattern that rolls out when the main blower powers on.
@VictorGarcia-ri6uw
@VictorGarcia-ri6uw 2 жыл бұрын
Where can I buy the spark igniter wire?
@rodgraff1782
@rodgraff1782 2 жыл бұрын
Are there manufactures who are still using DSI. I thought everyone had switched over to HSI quite a while ago.
@acservicetechchannel
@acservicetechchannel 2 жыл бұрын
Almost all manufacturers use it for outdoor package units, thanks!
@mr.spliffaddikts9548
@mr.spliffaddikts9548 2 жыл бұрын
I have a question ?? Is there a device tool that a Hvac tech can u to plug on fan motor’s n control board to get a diagnosis besides a (multi meter ) to test all components
@mr.spliffaddikts9548
@mr.spliffaddikts9548 2 жыл бұрын
It’s there any please link it to the comment section please n thank
@chrisdeanndavison3626
@chrisdeanndavison3626 2 жыл бұрын
@@mr.spliffaddikts9548 The short answer is no, not really. Most furnaces for the last 30 years do have some sort of onboard diagnostics. When there is a problem, we count blinking lights on the control board and then find the key to what the blinking lights mean to narrow our search for the problem. However, some upper-end units do have more sophisticated means of diagnosing the issue. I service WaterFurnace geothermal units and use an Aid-Tool analyzer on the 3 Series and 5 Series units. Apparently, the 7 Series units can be diagnosed through an internet connection, but I have no direct experience with them. The analyzer can provide a lot of information about how the unit is operating and what issues it might have had or is currently having. Much better than blinking lights.
@dennisnoone7427
@dennisnoone7427 2 жыл бұрын
why does a new ds845 dont have a terminal for fame sense anymore? the one you have still have one, but if i google for a new one it doesnt
@windturbineclimber5412
@windturbineclimber5412 Жыл бұрын
How does it get up to 10000 volts?
@dakotabu
@dakotabu Ай бұрын
A few questions: The Gas Unit heater at the warehouse is not working. Why is the automatic ignition system not working two times? The LED light was out. I tested the 120V to 24Vac transformer, which is working. What is it not working cause? is it overload? limit switch or valve gas fail? or did the automatic ignitor system have a problem? it name is FENWAL. now it is discontinued. hard get order it because FENWAL company is gone. KIDDE-FEWNELL is a new company. Maybe I am wrong.
@zogonet
@zogonet 2 жыл бұрын
hello, can you provide Polisz subtitles on your channel
@EC20121
@EC20121 Жыл бұрын
Or why would it keep tripping?
@CecilMerrell
@CecilMerrell Жыл бұрын
Here is a great video that goes into detail about the flame rectification physics and how flames can act as a diode that basically makes a half wave rectifier -> kzbin.info/www/bejne/fJvVq5Wne6mhd9k
@CecilMerrell
@CecilMerrell Жыл бұрын
Additionally, looking into Townsend Discharge is an interesting physics rabbit hole.
@PBS-nm1uu
@PBS-nm1uu 10 ай бұрын
bad camera angle but good video
@OneLeggedTarantula
@OneLeggedTarantula Жыл бұрын
I didn't know they made these, but was just thinking what a waste of power the old glow ingiters waste.
@ausseamore8386
@ausseamore8386 Жыл бұрын
@JA-vy1gp
@JA-vy1gp Жыл бұрын
Great video !! Thank you
Gas Furnace Combustion Analysis Training with Tyler Nelson!
1:34:32
AC Service Tech LLC
Рет қаралды 30 М.
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 56 МЛН
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН
Gas Furnace Training Class! Basics, Operation, Components, Troubleshooting
1:20:49
Air Handler Heat Strips Not Working, Fan Blower Won't Turn On! Common Problems!
25:11
Standing pilots, combination gas valves, Thermocouples.
22:48
Love2HVAC with Ty Branaman
Рет қаралды 61 М.
How to Test Pressure Switch on a Furnace
14:14
Word of Advice TV
Рет қаралды 665 М.
How to Diagnose a Spark Ignitor Issue EP79
8:57
Nighthawk HVAC
Рет қаралды 14 М.
Furnace Gas Valve Not Opening - How to Fix It
8:16
Word of Advice TV
Рет қаралды 106 М.
The Real Operation of a PRESSURE SWITCH in a GAS FURNACE Heater! Also Testing!
13:37
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 56 МЛН