Great video! I just removed the blower motor, extracted the broken off door amd put the motor back in. It seems like it will be just fine, for me at least, without the thing in there! 🙂
@pakkelly3 ай бұрын
That truck owner is very lucky that you fixed both the actuator problem but more importantly the wet carpet problem. That cab must have smelled awful. Thank you for showing us how to fix it.
@stevenboyd7183Ай бұрын
Thank you very much for the video. I just did not see where the Dot on the Gear was supposed to be. 😊
@roelangel2008Ай бұрын
Same. Did you figure it out?
@unknown9218 Жыл бұрын
Does the same thing go for a 2001 dodge rema 2500 5.9 gas?
@levisvarela3735 Жыл бұрын
now can i just install a knob like a cabinet knob so it becomes a manual and problem solved?
@matthewbass15876 ай бұрын
Does the AC dial need to be set in a certain spot when you reinstall the actuator? Or does it just matter where the blend door and thw actiaryor gears are lined up. Im only getting semi cool air right now. I also did take th batteries off or turn ignition 20 times like the manual said. Plan on doing that tom.
@TheOldtimecountry Жыл бұрын
will a new actuator control module fix this issue ? I found an after market for $30.00 . I can't tell what exactly was replaced but it looks like a new module would fix the issue .
@someleverpuller Жыл бұрын
Nope I pulled mine out 4 years ago and it happened again this week
@xxkillervibezxx19192 жыл бұрын
Would this cause the ac compressor not to kick on, mines stuck on heat and when I turn the ac on the compressor doesn’t come on
@AutomedicGarage2 жыл бұрын
No this has no control over the ac compressor. That is controlled by your mode switch, this is for the blend door.
@bgy1591 Жыл бұрын
Mine was cracked as well. Not sure if this is my issue. Not sure how it could be but every time I hit the brakes hard I hear a pop and my ac shut off
@AutomedicGarage Жыл бұрын
Door was flopping around in there probably
@russellcarroll6661 Жыл бұрын
Hey I am having the same issue did you ever resolve your issue
@russellcarroll6661 Жыл бұрын
@bgy1591
@bgy1591 Жыл бұрын
@@russellcarroll6661 yes and I also had a leak and was low on refrigerant but I believe this was what was causing the popping sound and causing it to turn to hot
@russellcarroll6661 Жыл бұрын
Great I’m gonna give it a go thanks !
@jrsblogs2 жыл бұрын
I’m only getting Ac to blow on my front window defrost not my front
@AutomedicGarage2 жыл бұрын
Your mode door is stuck on defrost then.
@gregz42492 жыл бұрын
@@AutomedicGarage do you have a video for mode door, what actuates the mode door
@AutomedicGarage2 жыл бұрын
That would be your mode actuator
@AutomedicGarage2 жыл бұрын
I do not currently have a video for a mode door actuator problem
@jomine16 Жыл бұрын
Do you know where is the mode door actuator located? I just replaced the blend door actuator which fixed my heat and AC but the mode is stuck in defrost and feet area and wont change to anything else
@1122Genesis Жыл бұрын
Where in the world do you get one of those broken / cracked plastic suckers ? ( Help Thanks GD )
I need these things done on my 1998 dodge ram 1500. I am in the process of trying to find someone to do this . I need a blower replaced also.
@JoseRamirez-qt1ee9 күн бұрын
What’s the part number please?
@PaulHudson2-253 жыл бұрын
This actuator must be in a different location for the gas motor trucks I have a 97 and 98 gas motor and the actuator is not located like your Cummins is????
@themightydodge38629 ай бұрын
My '98 gasser(diesel conversion) is the same as my '94 diesel was. It doesn't have one either. It's mechanical.
@PaulHudson2-253 жыл бұрын
Is the actuator in a different location because your truck is a diesel? I have a 97 and 98 gas motor and the actuator is not located like yours????
@Smittyschannel2 жыл бұрын
should be the same
@dglsrllr Жыл бұрын
Earlier years had a cable ontop of heater box remove glove box and can go in and manually select
@bsrob16 ай бұрын
Hello, great video. Good tips. I came across it in my research lol. I have a 2000 1500 ram 5.2. When the a/c or heat are on the front vents, the driver side blows significantly harder than the 2 passenger side vents. Doesn’t make a difference if heat or a/c. Everything is clear , nothing blocking it. Blower motor sounds strong. Only strange thing I notice is when on Max a/c (or regular ac or even vent heat) it comes out the vents AND the floor. Is this normal? You’d think max a/c would be top vents only. Thank you
@AutomedicGarage6 ай бұрын
Max ac is only different from ac because it pull air from inside cab, that’s why it blows harder also.
@bsrob16 ай бұрын
@@AutomedicGarage thank you for reply. My next question would when it’s on a/c or max a/c is it supposed to blow out floor vents also? I thought it was only supposed to come out the front facing vents
@AutomedicGarage6 ай бұрын
@@bsrob1 ac is only on vents not floor. Your nose door must be stopping at the floor and vent combo selection
@bsrob16 ай бұрын
@@AutomedicGarage is this door easy to get to to replace? I’d say that’s where some of my passenger side vent volume is going if the door you speak of is stopping at vent and floor
@Edaloy27 Жыл бұрын
I have a 95 12V with the same problem, vacuum is good, I had the condensation hose problem as well, thought it was a window/door leak it drove me nuts till I found the problem, anyway..is the blend door actuator located passenger side under the dash? also can I buy that an entirely new actuator, Thanks
@AutomedicGarage Жыл бұрын
Yea you can get an actuator but it’s usually just the plastic collar that’s broke. Heater treater fixes that. And it is located under the passenger side of dash.
@ScottDoten Жыл бұрын
Nice work! 👏
@anthonyhurst5898 Жыл бұрын
Where do you get the upgrade at?
@AutomedicGarage Жыл бұрын
Heatertreater.com
@dglsrllr Жыл бұрын
@@AutomedicGarage the link does not go to anything like what you described...
@AutomedicGarage Жыл бұрын
@@dglsrllr did you click on the link in the description? It works for me goes directly to their website. Go to the menus then and select the correct make and model your looking for.
@samgarofalo246110 ай бұрын
What did you line the dot with on the top gear
@AutomedicGarage10 ай бұрын
Man it’s been years since I’ve done another heater treater on a Cummins, I honestly done remember but I do remember they had good instructions telling you what to do.
@williamhorton5324 Жыл бұрын
Hey I can’t find the kit with the stud
@AutomedicGarage Жыл бұрын
I haven’t done one of these in awhile. I hope they didn’t quit making them.
Dude how do u turn recirculation on a Dakota 2001 doesn’t have a button for it
@AutomedicGarage3 жыл бұрын
Not sure on a Dakota....I’m mainly just work on 1/2 tons and bigger.
@mikedwalk2getfit9133 жыл бұрын
For a temp fix could you just turn by hand to set to one temp? Mine is stuck on heat 2001 dodge Dakota. Need on cold
@AutomedicGarage3 жыл бұрын
It would be hard to turn by hand due to the gears unless they are all broke.
@juliava6052 жыл бұрын
I know this is old but I thought I'd respond anyway. I have a Dodge Roadtrek 190 Popular. It's built on a Dodge B3500 van. My blend door actuator doesn't function, BUT...I can turn it one way in the winter to get super hot heat. Then, in the summer, I flip the actuator the opposite way, and the heat stops coming in (or at least partially so). My problem is that the AC blows barely cool air rather than cold. The AC system has been fully checked and recharged. The line gets freezing cold but the air into the cab is blowing barely cool. That's my problem, but I wanted to answer your question by noting that YES, you CAN just turn the actuator by hand. My actuator is accessed by removing the glove box. Very easy to turn by hand. (Unfortunately for me, in summer it must not close the blend door effectively enough because it seems some heat must still be getting through. But that may not be a problem for you.) Good luck!
@dannyclark9820 Жыл бұрын
So what do I fix if I don’t have an electric actuator ?
@AutomedicGarage Жыл бұрын
Is yours on a 1500 gas burner?
@dannyclark9820 Жыл бұрын
@@AutomedicGarage yep
@AutomedicGarage Жыл бұрын
@@dannyclark9820 I wish I had a good answer for you but the only dodges I work on are the Cummins but I’m assuming you have vacuum operated blend and mode doors and you more than likely have a vacuum leak/problem.
@dannyclark9820 Жыл бұрын
@@AutomedicGarage thank you I’ll keep digging
@dglsrllr Жыл бұрын
The older trucks 98.5 and below have a cable ontop of heater box remove glove box (if dash is still in tact) and can select manually
@irageatf0rt2 жыл бұрын
Can that blend door being broken cause the A/C on my 02 Cummins to only blow from the floor?
@AutomedicGarage2 жыл бұрын
No, that would be your mode door
@Tempsho2 жыл бұрын
@@AutomedicGarage Or a vacuum leak if it doesnt change vent positions
@AutomedicGarage2 жыл бұрын
@@Tempsho I wasn’t insinuating it couldnt be a vacuum leak. The point it if it’s only blowing in one location it’s something to do with the mode door meaning the door itself, controls, vacuum leak, etc.
@Tempsho2 жыл бұрын
@@AutomedicGarage all good, I was just trying to add a bit more to your comment. Some people don’t realize that in some vehicles, the vent position is controlled by vacuum and that it defaults to the floor/vent position if there’s a vacuum leak.
@ercysuazo726 Жыл бұрын
What was it?
@frogfrogger62602 жыл бұрын
So what you replaced, was that little plastic piece? With the gears, did you line them up? Did the metal tube go over the plastic piece ? Little lost.
@AutomedicGarage2 жыл бұрын
The heater treater mod replaces the inner plastic collar with a metal one.
@MtnBadger3 жыл бұрын
Any suggestions or advice about the '95? I have a LeBaron GTC convertible, blend door stuck closed.
@AutomedicGarage3 жыл бұрын
Never worked on one, but start simple if it’s vacuum operated check for leaks or dry rotted hoses, see if you can push the actuator by hand. If it’s electronic take the actuator off and turn your blend switch back and forth and see if the actuator works at all.
@jerrydugan11103 жыл бұрын
Where does one get the kit to fix it
@AutomedicGarage3 жыл бұрын
Heatertreater.com
@Heethanz4 жыл бұрын
Was that a racing drain tube you installed?
@AutomedicGarage4 жыл бұрын
Ben White it sure is
@ronnie_howard5 ай бұрын
Anyone ever tell you that you sound like Hank Hill 😂
@AutomedicGarage5 ай бұрын
@@ronnie_howard oh yea, if you look through a lot of our comments you see that a lot. Doesn’t really sound like a insult to me cause I loved that show.
@ronnie_howard5 ай бұрын
@@AutomedicGarage I didn't mean it as an insult, I love King of the Hill too :)
@AutomedicGarage5 ай бұрын
@@ronnie_howard I wasn’t saying you did, I’m good with it.
@isaiahruiz32573 жыл бұрын
This helped me way better and easier better then the other shit the other people posted
@AutomedicGarage3 жыл бұрын
I try to help all I can. Thanks for the comment. Subscribe and keep watching our stuff. Thanks
@WilliamKruger-gc7ox7 ай бұрын
Is that 99% of the issues with the blend door, a broken collar?
@AutomedicGarage7 ай бұрын
If you hear clicking or popping it more than likely is
@WilliamKruger-gc7ox7 ай бұрын
@@AutomedicGarage I looked at mine and it would help if there was an actuator installed. 😵💫
@AutomedicGarage7 ай бұрын
@@WilliamKruger-gc7ox that would def help
@timtarwater24443 жыл бұрын
I dont think Mines got an actuator
@BiggHoss2 ай бұрын
I'm surprised they don't have this ran off of vacuum like everything else in this truck
@toddbowen68052 жыл бұрын
Nice
@Clip52993 жыл бұрын
I have a 97 dodge and I can't find that box
@juliava6052 жыл бұрын
In my 98 it's located behind the glove box. Glove box has three screws at the very bottom and pops right out.
@hobsonbeeman75298 ай бұрын
I do t think this fix applies to the 97 Dodge Ram with the Cummins, all mine are vacuum motors
@AlanGarcia-qc8se2 жыл бұрын
Tip the vent doors not opening up
@AutomedicGarage2 жыл бұрын
This is for the blend door, not the mode door. Vent is activated by the mode actuator.
@CrazyLuch13 жыл бұрын
#FUCKINAWESOME 💯💯💯💯💯💯💯💯💯💯💯✔🐇👊🦈💛🙏🙏😎😎😎 3RD AWESOME VIDEO N U PUT ME RT WHERE I NEEDED 2 BE After Flush Coolant Level Blovked Hoses SOMEBODY UNPLUGGED IT💥💥💥😛🤐😛😛😛🐇😝
@codycreager4428 Жыл бұрын
I don't even have that on my truck?
@AutomedicGarage Жыл бұрын
Yea, it’s only on the Cummins sry
@kileywiles41243 жыл бұрын
Where do I find that repair kit? Can't find in local stores
@AutomedicGarage3 жыл бұрын
Kiley Wiles heatertreater.net I bought it direct front them
Ohh the good old days..before things were designed to infuriate you so you say heck with it and take it to the dealership to fix..oink! Oink!! Not enough to sell you the overpriced car we must also get more for repair!! Oink oink
@timtarwater24443 жыл бұрын
Mines manual with a cable on top
@juliava6052 жыл бұрын
Same here. But the blend door doesn't seem to close all the way in the summer. I've got GREAT heat when I open the door, but when I close it for AC in summer, I get barely cool air coming through. AC system thoroughly checked and working.
@iflytango Жыл бұрын
Where's the diesel getting vacuum
@AutomedicGarage Жыл бұрын
The Cummins has a gear driven vacuum pump on driver side of motor
@garfieldbrooks75382 жыл бұрын
Voice it's too low can hardly hear them
@AutomedicGarage2 жыл бұрын
It was early on in my YouTubing, did the best I could at the time. Hopefully you got the concept. Thanks.
@WilliamKruger-gc7ox7 ай бұрын
You didn’t explain lining the gears up for shit
@AutomedicGarage7 ай бұрын
I didn’t know I needed to explain something that’s self explanatory. People like yourself that get on here and leave ridiculous comments trip me out. Thanks
@WilliamKruger-gc7ox7 ай бұрын
@@AutomedicGarage is there one dot, 5 dots? Where do they need to be lined up?
@AutomedicGarage7 ай бұрын
@@WilliamKruger-gc7ox this video has been up for years and your the first person to cry about it. Congratulations for being the first. This is about as straight forward as it gets. The shaft in the actuator is clocked. It can only fit in the blend door one way. What else do you want. Me to come fix it for you?
@WilliamKruger-gc7ox7 ай бұрын
@@AutomedicGarage well guess what. I never had to worry about fixing my actuator issue until now. Actually, the past 27 years I never worried about it. Perhaps you should’ve mentioned it’s a one way fit. BTW, there’s a ton of garbage DIY videos on KZbin and aside that yours points out where the actuator is and the common issue (plastic collar), this video rates towards the bottom. For future reference, if you wanna teach people things, don’t half ass it. 😬
@AutomedicGarage7 ай бұрын
@@WilliamKruger-gc7ox get off my channel. What does your actuator working for 27 years have to do with this? Why is it my fault you don’t know which end of a screw driver to use? Which one of us has thousands of followers and people thanking them for helping fix their trucks? Me. Don’t like it don’t watch it. Keep your crying to yourself.
@creamybistro15473 ай бұрын
Well that didn’t fucking work
@klarkpeterson6125 Жыл бұрын
my 99 dodge cummins only works on defrosters and will shut off but any other setting wont work has new hvac module and vacuum lines are good any idea on what it could be?
@AutomedicGarage Жыл бұрын
Is the blend door actuator working?
@klarkpeterson6125 Жыл бұрын
@@AutomedicGarage im not sure how can i check to make sure its working properly?
@AutomedicGarage Жыл бұрын
@@klarkpeterson6125 with the key on change your mode and listen and feel on the actuator. Then remove it so the same thing with it removed but plugged in. If you feel/hear clicking or it does nothing that’s where your problem is. When you remove it it will have a plastic bushing/connector that engages it with the shaft of the blend door. More often than not that plastic piece is broken. That’s where the heater treater mod comes in. Hope that helps.