AC 048 - Elevator Hoistway Protection

  Рет қаралды 3,789

archicorner

archicorner

Күн бұрын

Пікірлер: 21
@jjgarcia9436
@jjgarcia9436 2 күн бұрын
I could be wrong, but did you had a video about elevators lobby as well? I mean how to calculate/ design?
@yayaylb1
@yayaylb1 7 ай бұрын
Thank you for your videos. I have two questions. 1. Are cart lifts also considered hoistways, and do they need to comply with the same requirements as elevator hoistways? 2. Can the elevator lobby be shared with a waiting room. In other words, can a waiting space be in the elevator lobby, or do they have to be separate - one elevator lobby and one waiting room.
@juanadiaz6661
@juanadiaz6661 Жыл бұрын
Great job.
@khallidabdaala7705
@khallidabdaala7705 3 ай бұрын
O man you are just amazing
@mohammadhaggag
@mohammadhaggag Жыл бұрын
Great explanation 👏 I have a question, could you explain the difference between fire partion and smoke one ?
@charlescmyers
@charlescmyers 4 ай бұрын
Thank you so much for this video! I disagree, however with the interpretation of 3006.2 laying out 4 different scenarios for hoistway opening protection. 3006.2 literally reads: Elevator hoistway door openings shall be protected in accordance with Section 3006.3 where an elevator hoistway connects more than three stories, is required to be enclosed within a shaft enclosure in accordance with Section 712.1.1 and any of the following conditions apply: The building is not protected throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. The building contains a Group I-1, Condition 2 occupancy. The building contains a Group I-2 occupancy. The building contains a Group I-3 occupancy. The building is a high rise and the elevator hoistway is more than 75 feet (22 860 mm) in height. The height of the hoistway shall be measured from the lowest floor to the highest floor of the floors served by the hoistway. The key word is "AND" any of the following conditions apply, not "OR". This means that to require hoistway opening protection a hoistway would need to connect more than 3 stories, the type of construction require a shaft enclosure AND 1) No sprinkler, 2) I occupancy, 3) High rise shaft, etc. To me a 4 story elevator in a "R" occupancy (apartment building) protected sprinklers would NOT require a lobby or smoke curtain. Again the keyword being "AND". Bolstering my point would be to point out that it's redundant to make one of the scenarios "connecting more than 3 stories" and another scenario "being a high rise". Please let me know if I am off base here. My intention is certainly not as a harsh critic, more a student of code like you! NC/FL building inspector here. Thank you again for the great video!
@bismarckmendoza2948
@bismarckmendoza2948 Жыл бұрын
I have a question, if I have a 4story building apartment, can avoid elevators per exception 1 of "1009.2.1 Elevators Required"
@archicorner
@archicorner Жыл бұрын
Chapter 10 is for EGRESS requirements. Per this section an elevator must meet certain requirements for EGRESS if the building has 4 or more stories. However, even if a building only had 2 stories, an elevator would most likely be required for ACCESSIBILITY purposes.
@ibrahimJa-fh2cx
@ibrahimJa-fh2cx Жыл бұрын
Thanks for the demonstration and the drawings! But just to confirm, when you mention "No Lobby," you mean either (no lobby) or (elevator lobby "that is not enclosed")? I just get a bit confused when it comes to the difference between Elevator Lobby and No Lobby ... I do not know the difference.
@archicorner
@archicorner Жыл бұрын
The entire video is about “elevator lobbies” if there is a specific point of the video that you need confirmation on, let me know the time stamp of the video your referencing 😊
@gutiemv
@gutiemv Жыл бұрын
Thank you so much for your videos, they are very helpful. I was wondering if the video regarding Fire Department Access Elevators is still available, you mention Short 008 (8.48), but I couldn't find it. Thanks.
@archicorner
@archicorner Жыл бұрын
Now that yo mention it, I have not uploaded those shorts. I will look into it and upload them in the next few days. I must've forgotten (they were uploaded into my Patreon account a few months ago!).
@jacoburbano5379
@jacoburbano5379 Жыл бұрын
Can you talk about draftstopping drywall
@archicorner
@archicorner Жыл бұрын
Good option!
@TAHIRHUSSAINMEPINDUSTRY
@TAHIRHUSSAINMEPINDUSTRY Жыл бұрын
Excellent, your videos always practical knowledge & code reference. Did u made any video referring how to make wall construction one hour or two hour, video# ?
@archicorner
@archicorner Жыл бұрын
Check out episode 041.
@anuragsingh-sn8zw
@anuragsingh-sn8zw Жыл бұрын
Sir, Please make videos on Fire detection and protection equipment like fire detector, smoke detectors, sprinklers, hosereels, hydrants etc
@michellelevine8667
@michellelevine8667 Жыл бұрын
Can you do a video on how to calculate stairs??
@archicorner
@archicorner Жыл бұрын
I am not sure what you mean by how to calculate stairs. Please explain.
@CalciferPendragon
@CalciferPendragon 3 ай бұрын
🤍🤍
@anuragsingh-sn8zw
@anuragsingh-sn8zw Жыл бұрын
Sir, I am resident of India and have some list of queries regarding fire safety regulations. Please share your email id for me to share the queries to you?
AC 047 - Fire Extinguishers
13:32
archicorner
Рет қаралды 5 М.
How does an Elevator work?
11:33
Jared Owen
Рет қаралды 5 МЛН
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
Support each other🤝
00:31
ISSEI / いっせい
Рет қаралды 81 МЛН
Elevator Hoist Way Doors
8:21
Rescue Methods: Fire
Рет қаралды
Is My Ramp ADA Compliant?
9:14
Great Plains ADA Center
Рет қаралды 25 М.
AC 046 - Parking mania!
12:47
archicorner
Рет қаралды 2,1 М.
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 2,9 МЛН
How do Elevators work(Animation)
5:57
EMecha3D
Рет қаралды 869 М.
AC 021 - Stair ADA and IBC requirements
17:25
archicorner
Рет қаралды 37 М.
THIS is Why Your Heat Bill is So High
18:21
Home RenoVision DIY
Рет қаралды 2,9 МЛН
How to Design an Elevator Lobby | Pass the ARE 5.0
3:14
Designer Masterclass (designerMASTERCLASS)
Рет қаралды 9 М.